P P P P P

Similar documents
WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN

OPERATING and MAINTENANCE INSTRUCTIONS Taco Bell Hot Cabinet Full Size Model: H137S27D1TB & H137S27D1LTB Half Size Model: H137S273D1TB & H137S273D1LTB

OPERATING and MAINTENANCE INSTRUCTIONS Models: H137WSUA...D & H138WS18...D Series Humidity Holding Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCMQ Series Hot Cabinet and H138NPSCMQ-15A Series Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY CONVECTION and RETHERM OVENS with MICROPROCESSOR CONTROLS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor Undercounter AquaTemp HUMIDITY OVENS and CONVECTION OVENS 2000 WATTS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 12kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor CONVECTION OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 8kW QUIKTHERM RETHERM OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor QUIKTHERM RETHERM ROLL-IN OVENS WITH RACK 18,000, 12,000 or 8,000 WATTS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP TM HUMIDITY 12kW QUIKTHERM RETHERM OVEN

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT SMOKER OVENS

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS Models: 1000-CH-D SERIES

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AQUATEMP HUMIDITY CONVECTION and RETHERM OVENS

AHPO-6/18 GOLD PROOFER OVEN

HOT FOOD HUMIDITY CABINET MODEL HFD-3

Product Code: AP816. User Manual. T: F: Page 1 of 6

User Manual. Heater/Proofer Cabinets. Models: 177HEAT1836, 177HPI1812, 177HPI1836, 177HPU1812, 177HPU1836

WARMING AND MERCHANDISING CABINET

Cincinnati, OH USA

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

Cincinnati, OH USA

XC Portable Air Conditioning

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

FOOD WARMING/MERCHANDISING CABINET MODEL

User Manual / Installation Instructions

FOOD WARMING/MERCHANDISING CABINET MODEL 737/737HH

As a safety precaution we recommend all instructions and safety tips appearing in this manual be reviewed prior to operation.

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

C5 4 SERIES INSULATION ARMOUR PLUS HOT FOOD HOLDING CABINETS

AIR SCREEN REFRIGERATOR MODELS PHB495 & PHB15 OWNER / OPERATOR S MANUAL

OPERATING INSTRUCTIONS

22L Oven (Black) Instructions for Use

TOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice

WARMING AND MERCHANDISING CABINET

INSTALLATION & OPERATION MANUAL

FOOD WARMING/MERCHANDISING CABINET

INSTALLATION & OPERATION MANUAL

(rev. 08/21/13)

TOASTER OVEN INSTRUCTION MANUAL

OPERATIONS MAINTENANCE MANUAL

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

B.I.C.A Built-In Coffee Appliance

HOT FOOD HUMIDITY CABINET

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

OPERATING INSTRUCTIONS

MODEL 721 ELECTRICAL DATA: FEATURES: ACCESSORIES: DIMENSIONS: SHIPPING INFORMATION: CONVECTION OVEN 1/2 SIZE PAN

FOOD WARMING/MERCHANDISING CABINET

Operation Manual For Sodir. ½ Size Convection Oven FC-60, FC-60G

Installation and Operation Guide For

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

E-Chef Hot Food Table Installation and Operation Manual

INSTALLATION & OPERATION MANUAL

User Manual for AirFlow Convection Oven

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

ELECTRIC MULTI ROASTER

S M AN U AL. For The Dog Hut. Warmer Model Numbers: 8020 (120v) 8220 (220v)

OPERATING INSTRUCTIONS

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

INSTALLATION & OPERATION MANUAL

MODEL (Single Door) MODEL (2 Door pass through)

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in Holding Cabinets

User Instruction Manual

Technical Manual and Replacement Parts List. Cream Dispenser

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

OPERATING INSTRUCTIONS

I N S T R U C T I O N S

MODEL NO: MC02 BATCH NO: PR3547

1.7Litre Stainless Steel Kettle

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Part No Revised November / Instruction Manual Model #8150 AND #8151

Warming Drawer Use & Care Guide

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

Owner s Manual WARMER DRAWER. (Without Water Tray) Models WD-20, WD21A, & WD-35A. WD-20 Shown MANUFACTURING NUMBERS: P/N Rev.

Operating and Safety Instructions HS-7 & HS-11

MOBILE HUMI-TEMP CABINETS

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

INSTALLATION & OPERATION MANUAL

Wax Base Heater & Dispenser

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Modular Island Grill - Refrigerator Module

This owner s guide book is for the following 800 watts microwave oven model: EM-S625S

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

User Instruction Manual

INSTALLATION & OPERATION MANUAL

Transcription:

Rev. 11 (5/14) Page 1 of 5 H137SUA...C & H138S18...C Series s (Stainless) ELECTRICAL SPECIFICATIONS: Model No. Volts Watts Amps Hertz Phase NEMA H137SUA12C2K H137UA12C2K H138S1834C2K H1381834C2K H137SUA12C208 H137UA12C208 H138S1834C208 H1381834C208 H137SUA12C240 H137UA12C240 H138S1834C240 H1381834C240 H137SUA12CCAN H137UA12CCAN H137SUA9CCAN H137UA9CCAN H138S1834CCAN H1381834CCAN H137SUA12CC15A H137UA12CC15A H137SUA9CC15A H137UA9CC15A H138S1834CC15A H1381834CC15A H137SUA12C H137UA12C H137SUA9C H137UA9C H138S1834C H1381834C H137SUA9C208 H137UA9C208 H137SUA9C240 H137UA9C240 H137SUA6C H137SUA5C H138S1816C H138S185C H137SUA6C208 H138S1816C208 H137SUA5C208 H138S185C208 H137SUA6C240 H138S1816C240 H137SUA5C240 H138S185C240 120 2000 16.7 60 1 5-20P 208 2000 9.6 60 1 6-15P 240 2000 8.3 60 1 6-15P 120 1500 12.5 60 1 5-20P 120 1400 11.7 60 1 5-15P 120 1500 12.5 60 1 5-15P 208 1500 7.2 60 1 6-15P 240 1500 6.2 60 1 6-15P 120 1000 8.3 60 1 5-15P 208 1000 4.8 60 1 6-15P 240 1000 4.2 60 1 6-15P NOTE: The above model numbers are basic models. They may be followed by letters: M L, D or ending with S and/or Z. and }Canada and }Canada } Only

Rev. 11 (5/14) Page 2 of 5 H137SUA...C & H138S18...C Series s (Stainless) HOW TO INSTALL UNIT: 1. Place cabinet on level floor. 2. Place cabinet in a well ventilated area. 3. Plug cord end into proper wall outlet. INITIAL OPERATION: (For first-time operation only): NOTE: A new oven needs to burn off manufacturing oils and excess adhesive before its first use. Do NOT load food into oven until this has been done! 1. Turn the POWER switch on. The yellow light will turn on. 2. Turn thermostat to #10. 3. Let unit operate for one hour. 4. Turn unit off and let cool. 5. Wipe inside clean with detergent and hot water. HOW TO START UNIT: 1. Turn the POWER switch on. The yellow light will turn on. 2. Turn the thermostat to #6½. 3. Preheat cabinet for one (1) hour. 4. Put food into cabinet. 5. Turn thermostat to desired setting and close door. No. 8 setting = approx. 85 C / 185 F No.6 setting = approx. 71 C / 160 F No.4 setting = approx. 54 C / 130 F Proper food holding temperature is 60 C / 140 F or higher. NOTE: The optional digital thermometer display flashes when temperature in center of cabinet is below 140 F (60 C) or above 250 F (121 C). Call the factory if you need different settings. TO TURN OFF UNIT: Turn the POWER switch off. The yellow light will go out. WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY

Rev. 11 (5/14) Page 3 of 5 H137SUA...C & H138S18...C Series s (Stainless) WARNING BEFORE CLEANING CABINET: 1. Allow the cabinet to cool. 2. Do NOT use abrasives or harsh chemicals. Is your cabinet aluminum or stainless steel construction? Be sure your cleaner is suitable for that material. Note: Stainless Steel cabinets have an S in their model numbers. Cleaning hints: 1. Wipe up spills as soon as possible. 2. Clean cabinet regularly to avoid heavy dirt build-up. 3. Make a test spot with cleaner. 4. Follow manufacturer s directions on cleaner. 5. Do not mix cleaners. 6. Avoid drips and splashes. HOW TO CLEAN THE UNIT: Soil Cleaner Method Dirt Fingerprints, grease, oil Mild Detergent* and hot water, or mild abrasive cleaner. Steam (no strong alkaline additive) Mild abrasive cleaner. Oily or waxy cleaner. Chemical oven cleaner. 1. Wipe with soft, damp cloth. 2. Rinse with hot water. 3. Wipe Dry. 1. Rinse after steam cleaning. 2. Wipe Dry Apply with soft, clean cloth. Follow oven cleaner manufacturer s instructions 1. Apply with soft, clean cloth. Water Spots Mild abrasive cleaner. 2. Wipe with damp cloth. *Mild detergent includes soaps and non-abrasive cleaners. Note: Gaskets are removable for cleaning. TROUBLE-SHOOTING CHART: FAILURE: POSSIBLE CAUSE: 1. Yellow light at switch does NOT light. 1a. Circuit breaker/fuse to wall outlet is blown 1b. Cord is unplugged from wall outlet. 1c. Switch is OFF. 2. Unit does not heat. 2a. Thermostat set too low or is OFF. 2b. Switch is OFF. 3. Unit gets too hot or won t shut off. 3a. Defective electrical parts. UNPLUG UNIT FROM WALL OUTLET 4. Blower does not work or makes noise. 4a. Defective blower

Rev. 11 (5/14) Page 4 of 5 H137SUA...C & H138S18...C Series s (Stainless) REPLACEMENT PARTS: H137UA C/H1381834C and H137SUA C/H138S1834C 120 V 208 V 240 V Power Unit 2000W 0675-002 0675-005 0675-005 2000W + dig thrm 0675-002-D 0675-005-D 0675-005-D Blower kit 0769-180-K 0769-182-K 0769-182-K Heater kit 2000W 0811-268 0811-269 0811-270 1500W 0811-265 0811-266 0811-267 1400W 0811-275 None None 1000W 0811-074 None 0811-074-01 High Limit 0848-060 0848-060 0848-060 Terminal Block 0852-091 0852-091 0852-091 Thermometer Analog 5238-030-K 5238-030-K 5238-030-K Digital 5238-034-K 5238-034-K 5238-034-K Transformer (used w/digital thermometer) 0769-159 0769-159 0769-159 Thermostat Analog 0848-062-K 0848-062-K 0848-062-K Power Cord 2000W 0810-065-12 0810-039-07 0810-039-07 1500W (USA) 0810-029-05 0810-039-07 0810-039-07 1500W (Canada) 0810-065-12 0810-039-07 0810-039-07 1000W 0810-029-06 0810-039-07 0810-039-07 Power Switch 0808-116 0808-116 0808-116 Power Light 0766-094 0766-095 0766-095 Vent Fan 0769-165 0769-174 0769-174 Door, complete Aluminum UA12/UA6/1834 1221-524-K Aluminum UA9 1221-527-K Stainless Steel UA12/UA6/1834 1221-525-K Stainless Steel UA9 1221-526-K Stainless Steel UA5/185 1221-545-K Door, gasket Aluminum UA12/UA6/1834 0861-235-K Aluminum UA9 0861-236-K Stainless Steel UA12/UA6/1834 0861-185-K Stainless Steel UA9 0861-182-K Stainless Steel UA5/185 0861-250-K Door, handle Aluminum 0911-111 Door, hinge Aluminum 0519-087-K Stainless Steel 0519-074-K Door, latch Stainless Steel 1006-122-01-K 3 Casters 0569-313-K w/ Brake 0569-313-BK 5 Casters 0569-306-K w/ Brake 0569-306-BK H138 Rack Insert (1) 1103-103-K Wire Angle Call Kit Toll-free: (set of 2) 877-CRES COR (273-7267) Fax: 800-822-0393 www.crescor.com 0621-281-K

Rev. 11 (5/14) Page 5 of 5 H137SUA...C & H138S18...C Series s (Stainless) WIRING DIAGRAM