NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Similar documents
Safety Photo Beam UL MONITORED DEVICE

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Twin Photobeam Detectors Manual

Operating Instructions

Operations Manual. Motion Detector Module Model ZS10

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Installation, Operation & Service Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ion Genesis Pump Controller

Fire-Water Bowls Model 100

Ultrasonic Reflective Sensor

Fire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions

Macurco HD-11 Hydrogen Gas Detector

CD6102 / CD6102 OC / CD6102-2

Solar Powered Wireless Photobeam Sensors

Operating Instructions

WVD100. EZ Loop. Product Manual. Wireless Vehicle Detector. Installation Instructions Program Instructions. AP100 Relay Board S200 Sensor

Model TL104 MANTL104. Test Lamp for Flame Detection

Active Infrared Multi Beam Sensors

GRAND EFFECTS Fire-Water Bowls Model 100

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Original instructions JSNY7 Magnetic switch

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Model NT20e Installation Guide

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

SC Installation, Operation & Application Guide

Original instructions Sense7-series Non-contact coded safety switch

MaxLite LED Vapor Tight Linear Fixture

MINI-BEAM Expert Series

Controllers. Instruction Manual WARNING

Operating Instructions

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Long-Range Barrier Sensors

Instruction Manual WARNING

RK CO 2 Transmitter Operator s Manual

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

GETZ MANUFACTURING PART # CYLINDER DRYER

Ultrasonic Reflective Sensor

1022 R/T Remote Monitor

Proliphix Thermostat Installation Guide. Release 2.0

Continuous Relay Controller LC52 Series Owner s Manual

SC Installation, Operation & Application Guide

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

DISPOSER CONTROL CENTER

Flame Simulator User Manual. Publication Rev. A

Remote Relay Module (RRM)

FUME HOOD MONITOR ALNOR AIRGARD 200

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

MODEL HBX-1 P/N 3G59332

Active Infrared Multi Beam Sensors. R Series

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

ELSTON 52 CEILING FAN

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

MBCE-110/230UV Flame Sensor Module

Interrupted Ignition Series Oil Primary Control

Multiple Boilers Electro TS Series Application EB-C-STG5

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Technical Data. Installation

CAUTIONS ON INSTALLATION

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

SC Installation, Operation & Application Guide

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

SAFETY INFORMATION AND WARNINGS

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

OPERATING INSTRUCTIONS

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

SUTTON 52 CEILING FAN

Home Theater Interface Plate INSTALLATION INSTRUCTION

SC Installation, Operation & Application Guide

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Lubi Submersible Condensate Removal Pumps

(HSTAT Series) Instruction Manual

Environmental Monitoring SmartSlot Card

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

RK Combustible Gas Transmitter Operator s Manual

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Transcription:

O P E R A T I N G I N S T R U C T I O N S NIR-50-325 RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 8 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support: technical@emxinc.com www.emxinc.com

Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Configuration Settings and Wiring Diagrams 4 Indicators 5 Installation 5 Verification and Operation 6 Troubleshooting 6 Ordering Information 7 Warranty 7 NIR-50-325 Operating Instructions 1

Cautions and Warnings 1. Read and follow all operating and installation instructions. 2. Always follow gate operator manufacturer installation instructions regarding installation of Type B1 sensor and operator. 3. Disable the gate so it is unable to move. Refer servicing to qualified service personnel. IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. Retroreflective photoeyes rely on a reflective surface (a reflector) for proper operation. In some cases a vehicle with reflective surface at a given distance can act as a reflector and allow the gate to close on a vehicle. EMX Industries Inc. assumes no responsibility in this case and all the risks are on the installer, designer and user of the gate system with a retroreflective photoeye. In case such a risk is not acceptable, EMX Industries Inc. strongly recommends the use of a thru-beam type of a photoeye. Product Overview The NIR-50-325 retroreflective photoeye is an external entrapment protection device Type B1, non-contact sensor for use with automatic gates and doors. The light beam is pulsed near infrared. Since the reflector directs the beam back to the photoeye, wiring to the other side of the roadway is not required. The NIR-50-325 provides a signal to the gate or door operator that the beam is not obstructed. The operating range is up to 50ft. The NIR-50-325 operates over a voltage range of 12-30VDC and 24-30VAC. Two LED indicators provide status information at a glance, making set-up and alignment easy. A yellow LED indicates signal stability. A red LED indicates alignment with reflector (off when obstructed). The NIR-50-325 is configured for normally closed (NC) and 10k monitoring by the operator and complies with UL325 requirements effective August 1, 2018. The 10k termination resistor is built into the photoeye. Refer to operator manufacturer s instructions to ensure compatibility. Refer to operator installation instructions for proper monitoring selection. NIR-50-325 Operating Instructions 2

Specifications Specifications Operating range 0.5ft (0.1m) 50ft (15.2m) Sensitivity adjustment Potentiometer Signal stability indicator Yellow LED Alignment indicator Red LED Relay output Form C contacts (NO, COM, NC) 30VAC/VDC, 2A Resistive termination 10kΩ (internal) Response time 10ms Power (see Cautions and Warnings) 12 30VDC, 24 30VAC @ 60 Hz Current draw 83mA Operating temperature -4 131 F (-20 55 C) Environmental protection IP 66 IEC Dimensions (L x W x H) 1.3 (33mm) x 0.8 (21mm) x 2.6 (66mm) Weight 0.2 lbs (91g), Connections 5 wires, 6.5 (2m) cable Certifications CE, UL 325-2018 Sensor Dimensions Bracket Dimensions NIR-50-325 Operating Instructions 3

REFLECTOR- O Dimensions REFLECTOR-O-HD Dimensions NIR-HD Dimensions NIR-50-325 Operating Instructions 4

Indicators Sensitivity Adjustment Configuration Settings and Wiring Diagrams Wire color Description Brown Power input ( + ) Blue Power input ( - ) Normally Open (NO) contact Gray Relay output shown in energized state (power on, aligned with reflector, no obstruction) White Common (COM) contact Normally Closed (NC) contact Black Relay output shown in energized state (power on, aligned with reflector, no obstruction) NIR-50-325 Operating Instructions 5

Resistive NOTE: Remove power when wiring the unit NOTE: The relay contacts on the board and the references to them in these instructions are shown in the energized state, aligned with reflector and no obstruction Indicators Indicator Definitions Yellow On Unit is energized and signal is aligned and stable Yellow Off Unit is off or signal is unstable Red On Unit is energized and alignment is correct Red Off Beam is obstructed or unit is not aligned with the reflector Installation Install the NIR-50-325 according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Always follow the instructions of the gate operator manufacturer regarding installation of Type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries 2. When using the relay outputs, do not exceed the voltage/current ratings indicated in the specification table. The recommended alignment technique is to mount the NIR-50-325 at the desired location and hold reflector about 3 feet in front of the unit while watching the lights to assure that both remain lit. Move backward to the desired mounting location for the reflector. You may have to move the reflector up, down, left or right to keep the reflector in the middle of the signal path. This ensures NIR-50-325 Operating Instructions 6

the least troublesome setup by keeping the reflector off the edges of the signal where any movement may take it out of alignment. NOTE: The signal pattern is only 2 feet in diameter Verification and Operation Verify proper operation of the NIR-50-325 according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Verify that the NIR-50-325 and reflector are in line of sight and apply power. Confirm that the red LED and yellow LED are on, indicating power and proper alignment. 2. Place an obstruction (ex. hand) between the NIR-50-325 and the reflector. Ensure the yellow LED and red LED turn off. Check the operator control board and verify that the safety input is actuated. 3. Remove the obstruction and the yellow LED and red LED will turn on. 4. Follow gate/door manufacturer s installation instructions and safety checks to verify that the NIR-50-325 is operating properly. Troubleshooting Symptom Possible cause Solution Unit stays in detect No output No detection Unit out of alignment Reflector covered with dirt, dust, snow, or water Water inside reflector No Power Bad connection, wires broken Improper wiring Unit not powered Other reflective surface causing signal return Verify alignment Clean reflector surface of contaminants Replace reflector Check power and wiring as per chart on page 4 and 5 Check connections Verify wired to correct inputs on operator Check power Check surrounding area for reflective surface NIR-50-325 Operating Instructions 7

Ordering Information NIR-50-325 REFLECTOR-O REFLECTOR-O-HD NIR-HD Retroreflective photoeye; includes mounting bracket with hardware Reflector, 3 dia. Protective hood for reflector Protective hood for NIR Warranty EMX Industries Incorporated warrants all products to be free of defects in materials and workmanship for a period of two years under normal use and service from the date of sale to our customer. This warranty does not cover normal wear and tear, abuse, misuse, overloading, altered products, damage caused by incorrect connections, lightning damage, or use other than intended design. There is no warranty of merchantability. There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein. EMX Industries Inc. sole responsibility and liability, and the purchaser s exclusive remedy shall be limited to the repair or replacement at EMX Industries option of a part or parts found not conforming to the warranty. In no event shall EMX Industries Inc. be liable for damages, including but not limited to damages resulting from non-conformity, defect in material or workmanship. Effective date: January 1 st, 2002 NIR-50-325 Operating Instructions 8

BLANK PAGE NIR-50-325 Operating Instructions 9

BLANK PAGE NIR-50-325 Operating Instructions 10

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax: (216) 518-9884 salessupport@emxinc.com Revision 1.4 3-1-18 NIR-50-325 Operating Instructions 11