NYC Department of Education

Similar documents
NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education Building Condition Assessment Survey :49AM :00PM

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

Electrical Inspection Special Electrical

Electrical Inspection Special Electrical

PLATTEVILLE MIDDLE SCHOOL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Florence High School / Middle School Page 1 of 3 Florence, WI

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Transcription:

Building Assessment Survey 2017-2018 Asset: HS FOR MATH, SCI & ENGINEERING-M, 240 CONVENT AVENUE, New York, 10031 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-12-20 11:37 AM 2018-01-09 12:50 PM Asset Data Type of Service Does Interactive Whiteboard (IWB) Exist? Water Penetration in Electrical Room? Have any Systems/Major Building Components been upgraded? DEDICATED INTERCOMS IN FIRE RESCUE AREAS Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms in your building? Answer Below Ground Yes Yes Systems: Years: 2011 Systems: Years: 2006 Systems: Years: 1987, 2006 Systems: Years: 1987 Systems: Years: 1977 Science Rooms (Except Fluorescent ) All Other Electrical Systems and Components (Except Service Switch, - Security, Fire Alarm System - Standard Sub Panel, Emergency Light/Exit Light Panel) Molded Case Circuit Breaker Panel Board Emergency Light/Exit Light Panel Switchboard Priority Priority Priority Exist Category Last Year? Description Component Affected Location Description Person(s) tified Person(s) Title Status PhotoImage condition recorded Inspection Electrical AUDITORIUM CAFETERIA CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Does a Chandelier exist? Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED COMPUTER LAB PB/A&W Page 1 of 13

COMPUTER LAB Power Panel Power Panel Power Panel Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles Building Assessment Survey 2017-2018 Yes PB/A&W Page 2 of 13

COMPUTER LAB Raceway With Receptacles GYMNASIUM KITCHEN LIBRARY LOCKER ROOM MULTIPURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB Power Panel Alternative use Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Emergency Gas Shut-Off Valve Building Assessment Survey 2017-2018 Yes PB/A&W Page 3 of 13

SCIENCE LAB Emergency Gas Shut-Off Valve Emergency Shut-Off Power Power Supply Instructor Unit Student Unit Meter Demonstration Unit Projection System SCIENCE PREP ROOM Power Panel Alternative use Power Panel Alternative use Fixture - Fluorescent Fixture - HID Building Assessment Survey 2017-2018 PB/A&W Page 4 of 13

SCIENCE PREP ROOM Fixture - HID Fixture - Incandescent Fixture - LED Emergency Gas Shut-Off Valve Emergency Shut-Off Power Power Supply SWIMMING POOL TOILET ROOM - STAFF Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED TOILET ROOM - STUDENT Fixture - Fluorescent Building Assessment Survey 2017-2018 PB/A&W Page 5 of 13

Building Assessment Survey 2017-2018 Electrical Inspection TOILET ROOM - STUDENT Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED AUXILIARY SIGNAL/BELL SYSTEM Replacement Quantity 28,000 Replacement Uom EMERGENCY DC STANDBY BATTERY POWER EMERGENCY GENERATOR SET Automatic Transfer Switch (ATS) Instance Electrical Room 19 Instance Dayton Equipment Transfer Switch Capacity/Size Quantity 150 Amps Nameplate Installation Year 2006 Battery Charger Diesel Natural Gas EMERGENCY LIGHT/EXIT LIGHT PANEL LESS THAN 20% SPARE CIRCUIT BREAKERS Location/Instance Electrical Room 19 Quantity 1 INSTALL NEW PANEL BOARD Urgency of Action PRIORITY 5 Photo1 photo recorded violations recorded. EMERGENCY LIGHTING Battery Pack n Battery Pack EXIT LIGHT Battery Pack PB/A&W Page 6 of 13

Building Assessment Survey 2017-2018 Electrical Inspection EXIT LIGHT Battery Pack FIXTURE NOT OPERATIONAL Location/Instance Main Entrance Lobby Quantity 2 Urgency of Action PRIORITY 5 Photo1 photo recorded violations recorded. n Battery Pack EXIT/EMERGENCY LIGHT CITY FIRE ALARM SYSTEM FIRE ALARM SYSTEM Replacement Quantity 28,000 Replacement Uom Bell/Horn Strobe Manual Pull Station Fan Shutdown Control Duct Smoke Detector Area Smoke Detector CO Detector Heat Detector Elevator Recall Magnetic Door Holder/Contactor Fused Cutout Panel Fire Alarm Digital Communicator Instance Instance Main Entrance Lobby PB/A&W Page 7 of 13

Building Assessment Survey 2017-2018 Electrical Inspection FIRE ALARM SYSTEM Fire Alarm Digital Communicator Honeywell Equipment Fire Alarm Communicator Capacity/Size Quantity 5 Zones Nameplate Installation Year 2006 Main Panel Bell At Panel Fire Alarm Control Panel (Electronic) Instance Main Entrance Lobby Instance Edwards System Technology Equipment Fire Alarm Control Panel Model EST 2 Capacity/Size Quantity 12 Zones Capacity/Size2 Quantity 1 Capacity/Size2 UOM Section(S) Diagram Installation Year 2006 Fire Alarm Control Panel (Standard) Sub-Panel Bell At Panel Fire Alarm Control Panel (Electronic) Fire Alarm Control Panel (Standard) Instance Electrical Room 19 Instance ACME Equipment Sprinkler Alarm System Capacity/Size Quantity 2 Circuits Inspector Estimate Installation Year 1965 PB/A&W Page 8 of 13

Building Assessment Survey 2017-2018 Electrical Inspection FIRE ALARM SYSTEM Sub-Panel Fire Alarm Control Panel (Standard) BEYOND USEFUL LIFE Location/Instance Electrical Room 19 Quantity 28,000 Urgency of Action PRIORITY 1 Photo1 photo recorded violations recorded. Instance Electrical Room 19 Instance ACME Equipment Automatic Fire Detection System Capacity/Size Quantity 4 Circuits Inspector Estimate Installation Year 1965 BEYOND USEFUL LIFE Location/Instance Electrical Room 19 Quantity 28,000 Urgency of Action PRIORITY 1 Photo1 photo recorded violations recorded. Remote Annunciator Display Monitor Panel Printer 5 - Poor PRINTER NOT OPERATIONAL Location/Instance Room B13 Quantity 1 Urgency of Action PRIORITY 5 Photo1 photo recorded violations recorded. PB/A&W Page 9 of 13

FIRE ALARM SYSTEM Remote Annunciator Punch Register Sprinkler Flow/Air Pressure Switch Tamper Flow Switch/Chain GROUNDING SYSTEM INTERCOM SYSTEM LAN Local Distribution Frame (I/LDF) Main Equipment Rack (MDF) LIGHTNING PROTECTION MOTOR CONTROL CENTER MOTOR STARTER/CONTACTOR PANEL BOARD Fused Disconnect Switch Type Fused Knife Switch Type Fused Toggle Switch Type Molded Case Circuit Breaker Type Location/Instance Quantity 1 PANEL BOARD DIRECTORY MISSING OR REQUIRES UPDATING Corridor by Room B19 MAINTENANCE Urgency of Action PRIORITY 2 Photo1 Building Assessment Survey 2017-2018 photo recorded violations recorded. PUBLIC ADDRESS SYSTEM Replacement Quantity 28,000 Replacement Uom Instance Room B13 Instance Model Dukane 250 PB/A&W Page 10 of 13

Building Assessment Survey 2017-2018 Electrical Inspection PUBLIC ADDRESS SYSTEM Installation Year 2006 CLOCK NOT OPERATIONAL Location/Instance Rooms B13, C05 Quantity 2 Urgency of Action PRIORITY 3 Photo1 photo recorded violations recorded. SECURITY IPDVS/CCTV System Replacement Quantity 28,000 Replacement Uom Installation Year 2006 Intrusion Alarm System Replacement Quantity 28,000 Replacement Uom Central Control Panel Instance Room B16 Instance Model Vista - 128B Installation Year 2006 Infrared Sensor Panic Switch Remote Annunciator Siren/Strobe Ultrasonic Sensor - Security SERVICE SWITCH Instance Electrical Cage in the Tunnel Instance PB/A&W Page 11 of 13

Building Assessment Survey 2017-2018 Electrical Inspection SERVICE SWITCH Metropolitan Equipment Service 1 Capacity/Size Quantity 800 Amps Inspector Estimate Installation Year 1965 BEYOND USEFUL LIFE Location/Instance Electrical Room 19 Quantity 28,000 Urgency of Action PRIORITY 1 Photo1 photo recorded violations recorded. Instance Instance Electrical Cage in the Tunnel Metropolitan Equipment Service 2 Capacity/Size Quantity 800 Amps Installation Year 1965 Inspector Estimate BEYOND USEFUL LIFE Location/Instance Electrical Room 19 Quantity 28,000 Urgency of Action PRIORITY 1 Photo1 SWITCHBOARD Number of Spares 1 Air Circuit Breaker Type Fused Disconnect Switch Type photo recorded violations recorded. Instance Electrical Room 19 Instance I.T.E. Imperial Corp. Equipment Main Dist. Panel. 1 PB/A&W Page 12 of 13

SWITCHBOARD Fused Disconnect Switch Type Capacity/Size Quantity 800 Capacity/Size2 Quantity 2 Capacity/Size2 UOM Installation Year 1977 Amps Total Section(S) Nameplate Instance Electrical Room 19 Instance I.T.E. Imperial Corp. Equipment Main Dist. Panel. 2 Capacity/Size Quantity 800 Capacity/Size2 Quantity 2 Capacity/Size2 UOM Installation Year 1977 Fused Knife Switch Type Molded Case Circuit Breaker Type TELEPHONE SYSTEM PBX/Intercom Standard TRANSFORMER TV SYSTEM Cable System Exist? Operational? Main Equipment Rack Building Assessment Survey 2017-2018 Amps Total Section(S) Nameplate Yes PB/A&W Page 13 of 13