Emergency light. Safe solutions

Similar documents
Dublin airport - Dublin, Ireland

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

LED EMERGENCY LIGHTING

Emergency Lighting Design

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

Emergency Lighting User's Guide

Making Perfect Sense Of Safety

i-p65 is a high specification competitively priced emergency LED bulkhead utilising the latest LED and optic

Technical reference Reference & design

Saving on maintenance and energy

BEKA / EMERGENCY SIGNAGE LUMINAIRE RANGE FROM DAISALUX S.A. EMERGENCY

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING

EMERGENCY LIGHT SERIES

Element C3.5 Means of Escape

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

A Guide To BS Understanding the selection, spacing & siting of detectors

Sylproof Superia LED G2

Waterproof TCW060 just light

COSINE DEVELOPMENTS Reg. No. IT 1637/97

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

Mira Design Light is powerful Siteco NJ700 LED The future-fit and robust solution for high halls.

New Fire Safety Order

Requirements of EN 1838: illuminance of 5 lx for safety equipment

Indoor/ outdoor projector MINI-PROJECTOR-02 LED Ufo-02

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting

Micropoint 2 Surface. Emergency

GOODLIGHT LED. Dynamic Lighting. Normal care / Wall lighting unit

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

TECHNICAL SHEET. Road and residential lighting luminaire MATRIX-S-01 60LED. About the product MATRIX-S LED

PRODUCT OVERVIEW. DALI emergency lighting Integration for safe monitoring in smart buildings

Avenue Metro. The evolution of an icon. UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX

CoreLine Waterproof the clear choice for LED

New LED Product Offerings

PSFL , PSFL , PSFL , PSFL , PSFL

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems

Construction site lighting INFORMATION PACKAGE. mberg.com. Construction site lighting information package 1 (16)

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

SmartBalance recessed combining performance with smart design

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

LP Slim Round Refined and subtle design

TECHNICAL SHEET. Road and street lighting luminaire MATRIX-01 LED MATRIX LED MATRIX LED. About the product

Sirios LED Product overview. When Safety depends on the decisions you make

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

Evacuate everyone Sonos Pulse & Nexus Pulse

71 SKYTILE 36W 68 SKYTILE SENSE 76 SKYTILE SURFACE 5000 NEW NEW SKYTILE SKYTILE SKYTILE BASE LINEAR 28W SKYTILE SKYTILE SKYTILE SURFACE 6200

Low Location Lighting

DE MONTFORT UNIVERSITY DMU INVESTS IN LED FOR SUSTAINABLE CAMPUS DEVELOPMENT

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

CoreLine Wall-mounted the clear choice for LED

NEW RUSIC DYNAMIC - RSV RUHSTRAT STROMVERSORGUNGEN fills the gap. The all purpose safety lighting systems! Emergency lighting.

LITE SUSPENDED CEILING. Minimal design and incredible attention to detail, LITE. features high performances optics with perfect light

Fire Safety Protocol

Kirium and Sephora wall

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Promenade LED. Elegant bollard providing light and colour in urban areas

Inset Kit LED. Inset Trend Swing REF+ V2 5W 40 WH WW PRODUCT OVERVIEW

Lighting applications - Emergency lighting. EATON Life Safety Eaton Corporation. All rights reserved.

TECHNICAL SHEET. Indoor luminaire FIRA-08-2xT8 Colage. About the product

Integrated PIR detectors

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires

WE-EF LIGHTING USA QLS400 [R45] SERIES Wall luminaires surface mounted 2018

ABOUT INDUSTRALIGHT LIGHTING FOR INDUSTRY

CATALOGUE fidelitylighting.co.uk UK GREEN BUILDING COUNCIL COMPLIANT REGISTERED MEMBER DESIGN &

SmartForm the new standard for office lighting with modular recessed luminaires

ArtLED Gallery and Museum Spotlights

CATALOGUE FURNITURE & INTERIORS

PREMISES FIRE SAFETY LOGBOOK

Emergency Evacuation Lighting Inspection & Maintenance

TECHNICAL SHEET. About the product

ipanel LED Panel Light

The Power To Supply... All Your Electrical Products

w w w. l e t t h e r e b e l i g h t. c o m. a u

Industrial Hazardous Area Products

Carephone 52 Security You Can Feel

D O M E S T I C LED. Lighting C O M M E R C I A L

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

SmartForm the new standard for office lighting with modular recessed luminaires

DUNDONALD BOWLING CENTRE: LISBURN CITY AND CASTLEREAGH DISTRICT COUNCIL. Council Strikes Big with High Performing Energy Saving LED System

MANUFACTURED IN THE UK

SmartForm the new standard for office lighting with slender recessed luminaires

PREMIUM LUX 90LED VISIBLE

MADE IN SWEDEN quality and design PRODUCT CATALOGUE. Emergency lighting and information signs with extreme brilliance and sharpness!

Linergy II. England and Wales Cricket Board, Truro Linergy

Micropoint 2. Horizon Centre, Torbay Hospital Micropoint 2

Intelligent LIGHTING. A team of smart people to bring smart solutions to your lighting needs

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

HBE LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Serenga LED Emergency Lighting

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

TECHNICAL SHEET. Road and street lighting luminaire DELFIN-03 30LED 60LED. About the product DELFIN-03 30LED, DELFIN-03-60LED

Industrial high bay projector PREMIUM LUX 12LED RECESSED IP43

Movement-based energy control

A Guide To BS Understanding the selection, spacing and siting of detectors

TECHNICAL SHEET. Indoor luminaire FIRA-03-1xT8 AS Didactic. About the product. FIRA AS, FIRA AS Didactic

ClearAccent - Affordable recessed LED spot

Transcription:

Emergency light Safe solutions

Experience and know-how For more than two generations Glamox has developed, produced and distributed lighting solutions for the professional market. Emergency lighting has to comply with strict regulations for both products and projecting. Glamox takes its responsibility seriously and offers emergency lighting that meets all the different requirements for Europe. In critical situations, emergency equipment that works perfectly can mean the difference between life and death. Glamox has developed a range of emergency products that secure the best escape route lighting in addition to good design and performance. Glamox can offer you a unique range of products, both in terms of different design, different types of application and also for different type of systems. A freedom of choice whether you choose decentralised with selftest, addressable units or centralised battery. Great care has been taken to ensure that illustrations and technical specifications in this brochure are correct at time of publication. Glamox is not responsible for production related and technical changes to products presented in the brochure, changes to the selection and printing errors. Glamox takes no responsibility for the consequences such mistakes may have for users of the brochure. Emergency light - April 2012

Emergency light planning Planning your emergency lighting installation does not have to be confusing. Whilst it can be easy to miss out important areas or locations in your premises, please use this emergency lighting overview to direct you in what to look out for and what needs to be addressed. The benefits with planning emergency lighting solutions with Glamox are that we are working with standardised systems and high quality products that are here today and tomorrow. Contents Projecting step by step... 4 Areas to be covered... 6 Escape route lighting...8-14 High risk lighting...15 Anti-panic lighting...16 Standards for emergency light...18 Servicing and testing... 20 Alternative solutions... 22 System solutions... 23 Product overview...24-26

Projecting step by step Locate fire cells and escape routes on drawings Locate essential areas in the project Change of direction Change of floor levels Staircase Rooms without windows Fire technical equipment Decide type of system and product Centralised Stand-alone Integrated Self-test Adressable Example of fire technical drawing 4

Projecting step by step Plan and project escape route lighting 1 lux on centreline. Uniformity better than 40:1 Locate, plan and project high risk areas 10% of light level - minimum 15 lux. Uniformity better than 10:1 Locate, plan and project anti-panic areas 0.5 lux in area. Uniformity better than 40:1 5

Areas to be covered Planning emergency lights in your projects is not just about showing users the escape route. Lights must be carefully located to provide sufficient illumination according to the different areas of premises and must conform to the latest legislation. An emergency escape lighting system should normally cover the following areas: Exit doors and escape routes High risk areas Change of direction Stairways so that each flight receives adequate light Changes in floor level Intersections of corridors Fire fighting equipment Final exit door and outside building Anti-panic areas Each area has their own requirements and needs to be looked at individually. 6

Escape route lighting Escape route lighting has a superior objective to contribute to a safe evacuation from an area when normal illumination fails. That part of the building, which is prepared for evacuation, should be easily identified and used with great safety. Luminaires prepared for escape route lighting are divided into route lighting and sign lighting. Route lighting Route lighting should provide ample lighting to make an evacuation possible in a safe way. For escape routes up to 2 m widths the horizontal illumination on the floor should not be less than 1 lux on the centre line of the escape route and outside the centre line the illumination should be minimum 50% of the lowest level of the centre line. The ratio between maximum to minimum illumination level should not exceed 40:1. Regulation recommends the provision of a horizontal illumination at floor level on the centre line of a defined escape route (permanently unobstructed) not less than 1Lux. For escape routes of up to 2m wide, 50% of the route width should be lit to a minimum of 0.5 lux. For anti-panic areas a minimum level of 0.5 lux is required excluding a 0.5m border to the perimeter of the area. Wider escape routes can be treated as a number of 2m wide bands. The actual degree of illumination should be closely related to the nature of both the premises and its occupants with special consideration being given to old person s homes, hospitals, crowded areas such as pubs, discos and supermarkets, and to whether or not the premises are residential. Route lighting should provide ample lighting to make an evacuation possible in a safe way. 0.5 lx 1 lx 0.5 lx X/2 m X m 8

Escape route lighting Emergency escape signs Exit direction signs should mark changes in direction of emergency exit escape routes where it is not possible to spot the emergency exit. Signs directing escape routes should be illuminated or externally illuminated. Sign height H should consider the reading distance and be dimensioned according to the following formula: For internally illuminated signs: Max reading distance = 200 x H Along with route lighting the escape signs shall lead the users to safety. For externally illuminated signs: Max reading distance = 100 x H < 200 x H H Glamox E80 is designed for a maximum reading distance of 30m

Escape route lighting Corridors and intersections of corridors In a building it is important to have emergency lighting that clearly illuminates the escape routes and where there are changes in direction. This allows users to clearly identify their means of escape and should highlight the escape route signs. Emergency lighting in corridors allows users to clearly identify escape routes. Possible solution X X/2 E85 C: X = 17m Suitable products We offer a range of products that are ideal for covering changes in corridors, junctions and changes in directions. Please check details on E80, E85 C. E80 E85 C X = 17m 10

Escape route lighting Changes in floor levels Uneven flooring on escape routes needs to be illuminated so that in emergency users can act accordingly. In areas where flooring may become uneven on an escape route, a lighting unit should be fitted, so that it does not prove a danger to users. Uneven flooring can consist of single steps, ramps, sloping floors etc. Uneven flooring on escape routes need to be illuminated so it s not a danger to users. Possible solution X X/2 E85 C: X = 17m Suitable products We offer a range of products that are ideal for covering changes in floor level. Please check details on E85 C. E85 C X = 17m 11

Escape route lighting Windowless rooms All areas of a building need to be covered in case of evacuation, including toilet accommodation and other windowless rooms. When an evacuation is needed and users must make their way out of the building safely, it is necessary that all escape routes are visible. Small rooms are no exception to this rule, they need to be well lit so that users can find their way to safety. Small rooms also need to be covered with emergency lighting. Suitable products We offer a range of products that are ideal for windowless and small rooms. Please check details on E80, E85 WB, GEF. E80 E85 C GEF when IP rating is required 12

Escape route lighting Stairways Stairways and stairwells can present a potential hazard in an emergency. Emergency lights need to be fitted so that these challenging areas are made visible and safe to use. Ensure that stairways and stairwells are made visible and safe to use in emergency situations. Suitable products We offer a range of products that are ideal for covering stairways and stairwells. Please check details on E80, E85, A10. E80 E85 C A10 for integrated solution 13

Escape route lighting Doors and exits Ensuring that exit doors are well lit in an emergency can be the difference between evacuating a building and getting trapped inside. All exit doors need to be well lit to ensure that users can identify where to go at the end of escape routes. All exit doors need to be well lit to ensure that users can identify where to go. Possible solution Suitable products We offer a range of products that are ideal for covering exit doors. Please check details on E80, GEF, GFI2. E80 GEF when IP rating is required GFI2 for large areas 14

High-risk lighting In areas where high-risk operations are carried out, special requirements for emergency lighting prevail. For highrisk areas the emergency lighting should not be less than 10% of standard lighting and minimum 15 lux. The ratio between maximum and minimum illumination level should not exceed 10:1. Areas with heavy machinery and physical risk need to be kept well lit to allow the safe shutdown of machinery to avoid injury High-risk areas require special emergency lighting. Possible solution Suitable products We offer a range of products that are ideal for high-risk areas. Please check details on GEF, MIR, MAX. MIR/MAX for integrated solution GEF when IP rating is required 15

Anti-panic lighting An anti-panic area is defined as an area bigger than 60 m² where a large number of persons are gathered. The illumination of this area should provide sufficient emergency lighting, not to raise panic and enable persons to arrive at a place where the escape route can be identified. For anti-panic areas the horizontal illumination on the floor should not be less than 0.5 lux, and the ratio between maximum and minimum illumination level should not exceed 40:1. An anti-panic area is an area bigger than 60m 2 where a large number of people are gathered Suitable products We offer a range of products that are ideal for covering large open areas. Please check details on E85 WB, GEF, integrated solutions. E85 WB GEF C20 when IP rating is required for integrated solution 16

Standards for emergency light Specifying emergency light can very often be like stumbling through a minefield of different National and European standards. The installation of emergency luminaires and fire exit signs in premises must meet several legislations and also be agreeable with the business owner. The current requirements of legislation must then be met: National / European standards EN 1838:2012 Emergency light includes light technical conditions like reading distance, uniformity and level of light. EN 50171:2001 Central power supply systems Central power supply systems is a system standard that includes design, operation and maintenance of a central based emergency power supply. This is then referring to product standards for UPS and emergency luminaires. EN 50172:2004 Emergency light systems System standard for emergency light. This is a system standard that includes design, operation and maintenance of an emergency light system. This is then referring to product standards for Emergency luminaires and stationary batteries. EN 60598-2-22:1999 (Emergency luminaires) + EN 50091-1-1 (UPS) Product standards for emergency luminaires and Uninterruptible Power Systems (UPS). The Health and Safety (Safety Signs and Signals) Regulations 1996 state that final exits and locations where the escape route may be unclear must have signs installed to reduce uncertainty Local Authorities and Fire Prevention Officers will have preferences as to the requirements of signage and lighting, so seeking their views is always advisable 18

Servicing and testing To test an emergency lighting system you need to simulate a mains power failure on the normal lighting circuit or circuits of individual luminaires. This will force the emergency lighting system to operate and use the battery supply. This can be done manually or automatically. MAINTENANCE INSTRUCTIONS FOR EMERGENCY LUMINAIRES The batteries are described as consumables and are not covered by our 5 year warranty. The battery should be replaced with same item number. The item number is found on the label of the old battery. If this is unreadable you must use the entire luminaire description. The item number of the new battery shall be part of the operation and maintenance documentation. It is not necessary to disconnect the mains supply prior to changing the battery. It is recommended to disconnect the mains supply to self-test variants, as this will reset the test cycle and a battery discharge test will be done 48 hours after battery change. Responsibility and control, Emergency equipment Emergency lighting has an important function in any building. The operational and maintenance costs of emergency equipment are high. The investment costs often account for 5-10% of the total costs for emergency lighting equipment. When analysing operational and maintenance costs, the following should be taken into account: The equipment s energy requirements Monthly testing and control of the fittings and light sources Annual testing and control of emergency power sources Materials and parts Work connected to maintenance Operational and maintenance documentation. Log keeping. For emergency lighting that use fluorescent or compact fluorescent lamps as light sources in both emergency and in normal lighting operation, the emergency lighting will wear extra on the lamp. We therefore recommend, for safety reasons, to make group replacement of these lamps twice as frequent as for the rest of the lighting system. If there are light sources that don t light up during the emergency operation, it must be replaced immediately. Emergency luminaires must be tested and the results / actions must be logged and kept in accordance with the national building regulations. These refer to EN 50172, which states: 1. Functional test at least once per month. 2. Full Capacity test at least once a year. For safety reasons we recommend to fully discharge the battery every 3 month as a test to see if it s still functional. 3. The following should be recorded: a. Date of commissioning of the system b. Date of tests c. Date and comments to service of the facility d. Date of errors that occur at the facility and what actions must be implemented e. The date when the measures are implemented and test status measured Self Tests are tested according to EN 50172. If errors occur, the bipolar diode or a set of LEDs will indicate what type of error it is. The light patterns of the various errors are found in the user manual, which is a part of the operation and maintenance documentation. 20

Alternative solutions Integrated emergency lighting Designation: E1/(1 hour lighting time) or E3/(3 hours lighting time) Standard light luminaires where one of the light tubes also provides light in emergency operation. The solution has battery, diode and emergency lighting electronics built into the luminaire housing. Supplied as combined maintained M/non-maintained NM. Integrated LED emergency lighting Luminaire designation = E1L/ or E3L/ Standard luminaire with its own integrated LED light source for emergency use. The solution has battery, diode and emergency lighting electronics built into the luminaire body. The light source is dedicated to emergency lighting. Supplied as nonmaintained NM. Stand-Alone Designation = E1/, E3/ or Z (centralised) The luminaire is dedicated to emergency lighting. Comes as both sign or escape route lighting. Some versions supplied as combination (with applied sign). The combined solution is also supplied as combined maintained M/Non-maintained NM. Escape route light supplied as Nonmaintained (NM) and sign lights supplied as Maintained (M). Stand-Alone solution available for various types of light source. Often emergency lighting is looked at as a necessary evil when it comes to aesthetics. Glamox can today offer a complete range of route light and anti-panic light with LED based design that can be integrated into most of our commercial luminaires. To integrate emergency light into the general lighting is often the only way to meet the aesthetic demands in a modern building. The advantages of using the LED technology for route light and anti-panic light is that a dedicated light source for emergency gives a higher degree of safety and additionally you require less battery capacity and therefore lower battery cost. Glamox can also offer the more standard integrated emergency version when the room requires more light (example large ceiling heights). All our solutions can be offered in a Standard (S), Self Test (ST) and an addressable (DALI) version based on DALI protocol. Our aim is to offer a complete solution where low maintenance cost and high safety is the main objective. By using quick connectors between the battery and electronics and the LED and electronics the time spent on both mounting and maintenance is lowered to a minimum. Our reflector technology on LED gives a coverage area of up to 44 m² according to antipanic light regulations. 22

System solutions Manual test (S) In this case the power supply is manually cut to emergency light luminaires. During monthly function tests, the length of the test is a maximum of 25% of the expected lighting time. During annual tests the equipment should undergo a full discharge test to check battery capacity. Test status is found by visual checking of the charge diode and the light source at the same time that testing takes place. Tests and repairs should be logged with their status. Self-test (ST) Emergency light luminaires take control of the tests themselves and carry these out at the necessary times and intervals as dictated by regulations. Test status is found with a visual check of one or more two-coloured diodes in the luminaire. Visual control should take place on a monthly basis. Tests and repairs should be logged with their status. Addressable (DALI) DALI is an addressable, standardised control protocol designed for lighting. DALI has now also been extended to manage emergency lighting. In addressable emergency equipment the tests are programmed from a central unit. Test status are automatically logged in the central unit. Today, there are various types of software and control modules which manage DALI emergency lighting protocols. DALI Emergency lighting can be connected to other DALI controls in accordance with certain regulations. Glamox recommend DALI because it is an open standardised system and will be here today and tomorrow 23

Product overview E80-S accessories Wall bracket, flag bracket and suspension must be ordered separately. body material and colour White painted aluminium with component plate in Polycarbonate. connection Cable entry on top and knock-out in each side. 3 or 5 pole terminal block. E80-S is a surface mounted exit sign based on LED. Signs for both 20m and 30m reading distance are available. Can be supplied for manual, selftest and central controlled testing and monitoring. Using a environment friendly NiMh battery. Signs are included. emergency system mounting Supplied in standard (S), selftest (ST) or addressable (DALI) system for 1 or 3 hours duration. For surface ceiling mounting. Flag, wall and suspended possible by using a kit. the kit must be ordered separately. Selection of items,for more items and details see our web. Article E80-S 10x25 DOWN LED E3/S E80-S 10x25 DOWN LED E3/ST E80-S 10x25 DOWN LED E3/DALI E80-S 10x25 L/R LED E3/S E80-S 10x25 L/R LED E3/ST E80-S 10x25 L/R LED E3/DALI Article number E80103110 E80103210 E80103310 E80103120 E80103220 E80103320 E80-R body material and colour White painted aluminium with component box in Polycarbonate. connection 3 or 5 pole terminal block. emergency system Supplied in standard (S), selftest (ST) or addressable (DALI) system for 1 or 3 hours duration. E80-R is a recessed exit sign luminaire based on LED. Signs for both 20m and 30m reading distance are available. Can be supplied for manual, selftest and central controlled testing and monitoring. Using an environment friendly NiMh battery. Signs are included. mounting For recessed mounting. Spring-locking mounting clips are included. Selection of items,for more items and details see our web. Article E80-R 10x25 DOWN LED E3/S E80-R 10x25 DOWN LED E3/ST E80-R 10x25 DOWN LED E3/DALI E80-R 10x25 L/R LED E3/S E80-R 10x25 L/R LED E3/ST E80-R 10x25 L/R LED E3/DALI Article number E80003110 E80003210 E80003310 E80003120 E80003220 E80003320 24

Product overview E85-S WB / E85-S C body material and colour connection emergency system White painted aluminium with gear tray in Polycarbonate. Cable entry on top and knock-out in each end. A 3 or 5 pole terminal block. Supplied in standard (S), selftest (ST) or addressable (DALI) system for 1 or 3 hours duration. E85-S is a surface mounted escape route light or anti-panic emergency light system based on LED. The escape route system, E85-S C, is especially designed for corridors and covers a 17m corridor with 1 lux on centre line. The anti-panic light, E85-S WB, has a circular wide beam light distribution that covers 8x8m with the required 0.5 lux. Both variants can be supplied for manual, selftest and central controlled testing and monitoring. Using a environment friendly NiMh battery. mounting For surface ceiling mounting. Selection of items,for more items and details see our web. Article E85-S WB LED E3/S E85-S WB LED E3/ST E85-S WB LED E3/DALI E85-S C LED E3/DALI E85-S C LED E3/S E85-S C LED E3/ST Article number E85113100 E85113200 E85113300 E85103300 E85103100 E85103200 E85-R WB / E85-R C body material and colour connection emergency system White painted aluminium with component box in Polycarbonate. A 3 or 5 pole terminal block. Supplied in standard (S), selftest (ST) or addressable (DALI) system for 1 or 3 hours duration. E85-R is a recessed escape route light or anti-panic emergency light system based on LED. The escape route system, E85-R C, is especially designed for corridors and covers a 17m corridor with 1 lux on centre line. The anti-panic light, E85-R WB, has a circular wide beam light distribution that covers 8x8m with the required 0.5 lux. Both variants can be supplied for manual, selftest and central controlled testing and monitoring. Using an environment friendly NiMh battery. mounting For recessed mounting. Spring-locking mounting clips are included. Selection of items,for more items and details see our web. Article E85-R WB LED E3/S E85-R WB LED E3/ST E85-R WB LED E3/DALI E85-R C LED E3/DALI E85-R C LED E3/S E85-R C LED E3/ST E85-R C LED EZ Article number E85013100 E85013200 E85013300 E85003300 E85003100 E85003200 E85000100 25

Product overview GEF body material and colour Grey component body with a clear diffuser, both in polycarbonate. connection Cable entry on top or through knock-outs in each end. 4 pole terminal block in centre. emergency system Can be supplied as standard (S) or Selftest (ST). light source 1xT5 8W fluorescent All-in-one IP65 emergency luminaire for easy mounting. Based on 8W fluorescent light source. Including exit sign legends for mantained (M) variants. Can be supplied with manual (S) or selftest (ST) control. mounting Easy mounting by first loosening the gear tray from the body, connect mains to the termination block before re-connecting using the quick connector. optics With longitudinal prism-lenses in the front screen providing an excellent light distribution for escape route lighting. Selection of items,for more items and details see our web. Article Article number GEF 108 E1-3/S SINGLE M/NM 988811110 GEF 108 E3-3/S 120LM SINGLE NM 988811411 GFI2 body material and colour White painted steel frame. connection Cable entry in the centre of the back-plate. When using a ceiling mounting box the cable entry is on top. 5-pole push-in terminal block. emergency system Supplied in standard (S), selftest (ST) or addressable (DALI) system for 1 or 3 hours duration. light source 1xT8 18W Exit sign based on 18W fluorescent lamp. Up to 60m reading distance.can be supplied with system for manual, selftest and centrally controlled testing and monitoring. mounting For wall mounting or pendant mounting with wire suspensions that must be ordered separately. Selection of items,for more items and details see our web. Article Article number GFI2 30x60 118HF-Z 991123601 26

27

Integrated solutions Overview of product families with possibility for integrated emergency light. For more details see our web. interior Activus II C10 C20 C30 C50 C51 C60 C61 Medicus Minerva Modul Circle Modul Micro Modul Square Reed X-TYPE industry Eminent GIR T5 GIR T8 GPV2 i15 i20 i40 i45 MAX MIR MIX downlight CASA D20 LED D20-R D20-S Travel TraveLED architectural outdoor A10 A50 A51 Sinus ZAPP STING 28

Suspension system / Accessories complete suspension system cable & wire 2,5m cable 3 x 0.75 1.5m wire Art.no. standard: E80000006 Art.no. w/ceiling cup: E80000007 cable & wire 2,5m cable 5 x 0.75 1.5m wire Art.no. standard: E80000008 Art.no. w/ceiling cup: E80000009 wall suspension Art.no: E80000010 flag suspension Art.no: E80000015 block out Art.no: 10x26: E80000017 15x26: E80000018 complete set of cups Art.no: 815403244 mounting bracket for t-profile Art. no: 15mm 25001005 24mm 25001006 support plate Art.no E80: E80000020 E85: E85000020 30

www.glamox.com/gsx All our products are covered by a five year warranty. More information is available from our websites. BK999607