Laser Particle Size Analyzer

Similar documents

PSA Series. Particle Size Analyzer

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

AEROSOL SPECTROMETERS

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

Laser Scattering Particle Size Distribution Analyzer LA-930

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

Features and Benefits

Vertical Laboratory Autoclave A series:

File No. 28(1192)/2017/Pur Date: 19/06/2018

LABTRON LHI - Series Heating INCUBATOR

LABTRON LCOI - Series Cooling INCUBATOR

Features and Benefits

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

An FT-NIR Primer. NR800-A-006

User Meeting 8 or 9 September 2015: Laser diffraction Data Quality: Do s and Don ts. User meeting 8 or 9 September 2015 Sysmex

SP-3800AA Atomic Absorption Spectrophotometer

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

WASTEWATER Online UV%Transmission Analyzer

ISO INTERNATIONAL STANDARD

Dual Laser InfraRed (IR) Thermometer

Model S FT-IR SPECTROMETER

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

Laser Diagnostics and Optical Measurement Techniques

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Infrared Moisture Balance (FD-800)

Infrared Moisture Balance (FD-660)

Spectrum Detector, Inc.

NanoReady. Micro UV-Vis Spectrophotometer

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

THE Clifton RANGE. NICKEL-ELECTRO Ltd. Manufacturers of laboratory, medical and clinical equipment. NICKEL-ELECTRO Ltd.

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Dual Laser InfraRed (IR) Thermometer

Product data sheet Palas Fidas 200 S

Instruments Designed for POF & Fibre Optic Cable Testing

Crude Oil Centrifuge. Labocon Systems Limited

Grinding & Dispersing. Ψ-MIX Inline-Disperser A revolutionary system for mixing and dispersing of solids in liquids. our technology YOUR SUCCESS

Floor model Freeze Dryer

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Gas Detection in Process Industry The Practical Approach

Advantages / Characteristics

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

More Precision. thicknesssensor // The sensor for precise thickness measurements

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

Product data sheet Palas Promo 2000

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Aspirating smoke detection

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

The New DUSTTRAK II and DRX Aerosol Monitors

Manual PCE-889 pyrometer

ice 3000 Series Atomic Absorption Spectrometers

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

The New DUSTTRAK II and DRX Aerosol Monitors

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

LaserFOCUS VLF-250 Engineering Specification

for Drinking Water Systems

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

M700-Series OTDRs. or (800) , (603)

ML1 MULTI-LINE LASER INSTRUCTION MANUAL

BRANSONIC Bransonic Baths

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

BlueSpin Magnetic Hotplate Stirrer

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Air Resource Specialists, Inc.

Siansonic Technology Leading The Ultrasonic Technology

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Mercury Vapor Monitor VM-3000

NONWOVEN INDUSTRIES. Advanced Web Gauging Solutions. The Measure of Quality

Version: 1603 UV Accelerated Weathering Testers Weice Testing Instrument Co., Limited

IRT2 Dual Laser IR Thermometer - User Guide

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

UV-Micro Puck Multi. Instruction Manual. Contents: 1. Description Technical Data Instruction for Use

Hands-On Laser Beam Path Alignment Practical. Environment, Safety, Health & Quality Office SERF E141 Last updated: 12/28/2017

1,000W (DAP-60K: 100 W per digestion vessel)

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

SPECTRAL INSTRUMENTATION

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

CALIBRATION HOW IT WORKS

PML 2. The universal laboratory bead mill. Innovations for a better world.

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

LEARNING SPECIAL HAZARD DETECTION TYPES

HPLC Column Ovens and Temperature Controllers

Transcription:

www.labtron.com info@labtron.com

Laser particle size analyzer LLPA-A10 Laser particle size analyzer LLPA-A10 is a fully automatic cost effective and efficient particle size analyzer capable of measuring suspension, emulsion and powders. It uses laser diffraction measurement principle for measuring over the 0.1µm to 300µm particle size range for wet dispersion and is also well equipped with highly sensitive ring photoelectric detector which improves test accuracy. Features Comprehensive laser diffraction particle size measurement principle Highly sensitive ring photoelectric detector which improves the test accuracy Fully automatic software control Capable of measuring suspensions, emulsions and powders Automatic optical bench alignment Built in dispersing unit consisting carefully aligned stirring set up, ultrasonic dispersing unit and the sample circulating pipes Built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles Optional small capacity sample chamber which helps with measuring expensive/precious samples or samples difficult to be dispersed within the medium Analysis software uses an unique unconstrained data fitting technique developed to obtain data of unknown size distribution Manual and automatic mode of operation makes it user friendly Applications It finds wide application in cement industry, ceramics, environmental and soil applications, pharmaceutical industry. It is also used for measuring the particle size of food stuff as well as paints, pigments, coating, ink, toners, fillers etc.

Specifications Model no. Executive standard LLPA-A10 ISO13320-1:1999 Principle Analysis Measuring range Sample type Dispersion type Test speed Light source Operation mode Detector Detector channels no. Built-in ultrasonic function Agitator Revolutions Speed Circulate rated flow Circulate rated power Light path alignment system Accuracy Repeatability Sample tank volume Sample cuvette Software running Outer dimension (LxWxH) Net weight Laser light scattering Mie & Fraunhofer technique 0.1µm-300µm Suspension, emulsion, powders Wet < 2 min High performance He-Ne Laser, 632.8 nm Full automatic software control Ring photoelectric detector 96 pcs. Frequency: 40 khz, Power: 35 W, Time: 1s 0-300 rpm (Adjustable) 8 l/min 10 W Fully automatic 350 ml 10 ml (optional) Win XP/Win7 880 390 460 mm 44 kg

Laser particle size analyzer LLPA-A11 Laser particle size analyzer LLPA-A11 is fully automatic and intelligent particle size analyzer. It uses dual beam and multi-spectral detection system and laser diffraction measurement principle for measuring over the 0.01µm to 2000µm particle size range for wet dispersion and offers reliable and repeatable particle size analysis. Features Converging fourier transform light path Dual-beam and multi-spectral detection system and side-light scatter test technology improves precision and performance of test Capable of measuring suspensions, emulsions and powders Expanded measurement range to 0.01µm, making it suitable for small samples Automatic optical bench alignment Ultrasonic dispersion, mechanical stirring and circulation channel reasonably integrated in the interior of the instrument Built-in dispersion system ensures uniform dispersion and distribution of particles in the testing process Intelligent automatic mode of operation reduces the testing workload and also eliminate the interference of human factors Requires calibration once in a year Quick and simple calibration method Unconstrained free fitting technique User friendly Applications It finds wide application in cement industry, ceramics, environmental and soil applications, pharmaceutical industry. It is also used for measuring the particle size of food stuff as well as paints, pigments, coating, ink, toners, fillers etc.

Specifications Model no. Executive standard LLPA-A11 ISO13320-1:1999 Principle Analysis Measuring range Sample type Dispersion type Test speed Light source Operation mode Detector channels no. Built-in ultrasonic function Agitator Revolutions Speed Circulate rated flow Circulate rated power Light path alignment system Accuracy Repeatability Sample pool Sample cuvette Software running Outer dimension (LxWxH) Net weight Laser light scattering Mie & Fraunhofer scattering 0.01µm-2000µm Suspension, emulsion, powders Wet < 2 min High performance He-Ne Laser, λ= 632.8nm Fully automatic/ manual control 127 pcs. Frequency: 40 khz, Power: 35W, Time: 1s 0-300 rpm (Adjustable) 8 l/min 10 W Fully automatic, Precision up to 0.1µm 350 ml 10 ml Win XP/Win 7 1230 x 640 x 660 mm 58 kg

Labtron Equipment Ltd Sentinel House, Ancells Business Park, Harvest Crescent, Fleet GU51 2UZ, UK Telephone: 01252 413773 www.labtron.com info@labtron.com