LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Similar documents
soaring high. scoring high. Trading Co. LLC

Independent, accredited testing station Member laboratory of STL and LOVAG

Transportation. Distribution

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

AS/NZS 3133:2008 AS/NZS

A powerful network of experts at your service

Group THE ALI MIRZA GROUP OF COMPANIES CIVILCO OTHER GROUP COMPANIES

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Substations and high voltage installations exceeding 1 kv a.c.

Product Guide Low Voltage Switchboard & Switchgear

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

APPROVED PANEL OF SWITCHBOARD MANUFACTURERS FOR THE SUPPLY OF LOW VOLTAGE SWITCHBOARDS

Standards for MV switchgear rated for arc flash protection

AS/NZS IEC :2013

NHP CUBIC Switchboard solutions

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

NPS/003/025 Technical Specification for Fault Throwers

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

SECTION AUTOMATIC TRANSFER SWITCHES

AS/NZS IEC 62560:2014

POWER CONTROL! WE SPEAK THE SAME LANGUAGE

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Mains Power Filter 970MF10 970MF20. Installation Instructions

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

Neil Hewitt Electrical & Air Conditioning P/L

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

FALCON SERIES 12 METAL CLAD

The complete residential solution

CONTENTS AUTOMATIC TRANSFER SWITCHES

FALCON SERIES 12 METAL CLAD

AS/NZS :2016

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

NPS/003/006 Technical Specification for Primary 11kV & 20kV Distribution Switchgear

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

HMN-D2 Insert Series

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

INTERNATIONAL STANDARD

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Lloyd s Register Type Approval System Test Specification Number 3

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )

Australian/New Zealand Standard

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Annubar Flowmeter Series

IECEx Certificate of Conformity

Moulded case circuit brakers

SOUTH AFRICAN NATIONAL STANDARD

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Electrical Safety Requirements

KATALOGE. Trading of Electrical Switchgear, Lightings, Machineries & Construction Materials. Jamar Trading Co. W.L.L.

AS/NZS IEC :2015

Telecity. Table of Contents. Page. Section 3.2

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

SIVACON Partner Program and MVC Juergen Loeschberger, Siemens EM LP Partners. 21, 2017 I Berlin

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Datasheet - MZM 100 ST-SD2PREM-A

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Changes to Certification and its Impact on Manufacturers. Des McDonell CSE-Ex Pty Ltd

PolyGarde Metal-Oxide Surge Arresters

DC POWER DISTRIBUTION BOARD

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AS/NZS 3190:2011 AS/NZS

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

ANCILLARY LIGHT CURRENT EQUIPMENT

Where technical minds provide innovative solutions

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

Preface. This guide proposes a procedure for assembling the Prisma Plus System G.

MANUFACTURER OF LT PANELS

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Australian/New Zealand Standard

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

Prisma Plus Assembly Guide. System G

Explosion Protected Panelboards D2Z Series

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

I N D I V I D U A L SWITCH G E A R

AS/NZS :2015

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Datasheet - MZM 100 ST2-1P2PWREM-A

A/S Logstrup-Steel. Corporate Presentation

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Consumer Switchboards 4CS & 4FCS. Installation Instructions

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

Transcription:

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka

1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket on doors providing IP ratings up to IP55 Arc fault hinged vent for dissipation of ionised gases Large full width gland plates in roof Uniquely hinged and bevelled door allowing doors to open 165 degrees Quarter turn locks Doors double returned on four sides to maintain rigidity Generous vertical cable zones 300mm or 400mm wide Demountable / withdrawable power modules Form 3b or Form 4 separation Modular Construction NATA certified up to IP55 Ingress Protection Rating 2mm Zincanneal steel construction Designed to ensure maximum operator safety under all conditions Inbuilt arc fault chimneys included as standard - AS3439.1 Appendix EE Operating Voltage Ratings of 380/415/690VAC - AS3439.1 Operating Current Ratings up to 4000Amp Fault Current Ratings up to 100kA

Product Guide Low Voltage Motor Control Centre 2. Large horizontal cable zone for interconnecting PLC / marshalling cabling Full access to joints between horizontal and vertical busbars Horizontal and vertical busbar systems accessible through the front of the SCA Horizontal busbars available as 3 or 4 pole Dough moulded compound non hygroscopic horizontal busbar supports Horizontal busbars type tested up to 3400 Amps 100kA Glass reinforced nylon non hygroscopic vertical busbar supports Vertical busbars type tested up to 1000 Amps 80kA Vertical busbars available as 3 or 4 pole Lifting facilities built into base Full length, full depth horizontal cable zone Gland plates in base for bottom cable entry Heavy duty galvanised base

Product Guide Low Voltage Motor Control Centre 4. PROTECTION NOJA Power s LV MCCs meet the highest standards required for fixed, demountable or fully withdrawable MCCs or switchboards. NOJA Power s LV MCC is the only standardised range of low voltage switchboards and MCC s on the Australian market which fully complies with AS 3439.1 1993. The LV MCCs are fully ASTA certified to comply with BS EN 60439.1 and IEC 439.1 standards. NOJA Power s construction of low voltage switchboards and MCC s is quality assured. NOJA Power maintains an ISO 9001 quality assurance accreditation for the research and development, design, manufacture, testing, installation and commissioning of - Low and Medium Voltage Switchgear and associated microprocessor based controls. NOJA Power s comprehensive range of ASTA type test certificates includes all seven type tests defined in clause 8.2 under one certificate. These tests include: Type tests summary Verification of temperature rise limits Verification of dielectric properties Verification of short circuit withstand strength Verification of continuity of protective circuit Verification of clearances and creepage distances Verification of mechanical operation Verification of degree of ingress protection NOJA Power s low voltage switchboards and MCC s also include additional test certificates and reports to prove the ability to withstand the effects of internal arcing faults. Manufactured using the B&R Signature System. Test Description Rating Certificate No. Fault Rating Horizontal Phase Busbars 100kA 1 second 100725C Arc Fault Containment Temperature Rise Testing 80kA 1 second 13582 65kA 3 second 13582 50kA 3 second 13582 & 100944 Vertical Phase Busbars 80kA 1 second 13582 50kA 1 second 13582 & 100944 50kA 3 second 14907 Horizontal Neutral Busbar 50kA 3 second 100944 40kA 1 second 13582 & 100944 Vertical Neutral Busbar 50kA 1 second 100944 30kA 1 second 100944 Ground Busbar 30kA 1 second 100944 Starters 4-185kW (415V) 65kA 13582 Starters 4-400kW (690V) 80kA 101539 MCCB s 63-800A 65kA 13582 ACB s 80kA 1 second 101595 65kA 13582 65kA 1 second 13582 Starters fuse protected 65kA 415V 100782 Starters MCCB protected 65kA 415V 100601 MCCB s 65kA 415V 100782 Starters fuse protected 50kA 415V 7019.H Starters MCCB protected 50kA 415V 7019.H MCCB s 25kA 575V Starters fuse protected 4-185kW 13582 & 100944 Starters MCCB protected 4-185kW 13582 & 100944 MCCB s 63-800A 13582 & 100944 ACB s 1200-4000A 13582 5000A 101539 Impulse Withstand Starters & MCCB s (415V) 6kV 100944 Voltage Starters & MCCB s (690V) 8kV 101539 Busbar System 16kV 100944 Operating Voltage 380-690V Insulating Voltage 690V 13582 1000V 100944 Form of Segregation Form 4 13582 & 100944 Verification of the effectiveness of protective circuit 100944 Verification of clearance and creepage distances 100944 Verification of the effective connection between exposed 100944 conductive parts of the assembly and the protective circuit Verification of dielectric properties after short circuit tests 13582 & 100944 Degree of protection Ip43 7048.1.D Ip55 7048.2.D

Product Guide Low Voltage Motor Control Centre 4. PROTECTION NOJA Power s LV MCCs meet the highest standards required for fixed, demountable or fully withdrawable MCCs or switchboards. NOJA Power s LV MCC is the only standardised range of low voltage switchboards and MCC s on the Australian market which fully complies with AS 3439.1 1993. The LV MCCs are fully ASTA certified to comply with BS EN 60439.1 and IEC 439.1 standards. NOJA Power s construction of low voltage switchboards and MCC s is quality assured. NOJA Power maintains an ISO 9001 quality assurance accreditation for the research and development, design, manufacture, testing, installation and commissioning of - Low and Medium Voltage Switchgear and associated microprocessor based controls. NOJA Power s comprehensive range of ASTA type test certificates includes all seven type tests defined in clause 8.2 under one certificate. These tests include: Type tests summary Verification of temperature rise limits Verification of dielectric properties Verification of short circuit withstand strength Verification of continuity of protective circuit Verification of clearances and creepage distances Verification of mechanical operation Verification of degree of ingress protection NOJA Power s low voltage switchboards and MCC s also include additional test certificates and reports to prove the ability to withstand the effects of internal arcing faults. Manufactured using the B&R Signature System. Test Description Rating Certificate No. Fault Rating Horizontal Phase Busbars 100kA 1 second 100725C Arc Fault Containment Temperature Rise Testing Impulse Withstand Voltage 80kA 1 second 13582 65kA 3 second 13582 50kA 3 second 13582 & 100944 Vertical Phase Busbars 80kA 1 second 13582 50kA 1 second 13582 & 100944 50kA 3 second 14907 Horizontal Neutral Busbar 50kA 3 second 100944 40kA 1 second 13582 & 100944 Vertical Neutral Busbar 50kA 1 second 100944 30kA 1 second 100944 Earth Busbar 30kA 1 second 100944 Starters 4-185kW (415V) 65kA 13582 Starters 4-400kW (690V) 80kA 101539 MCCB s 63-800A 65kA 13582 ACB s 80kA 1 second 101595 65kA 13582 65kA 1 second 13582 Starters fuse protected 65kA 415V 100782 Starters MCCB protected 65kA 415V 100601 MCCB s 65kA 415V 100782 Starters fuse protected 50kA 415V 7019.H Starters MCCB protected 50kA 415V 7019.H MCCB s 25kA 575V Starters fuse protected 4-185kW 13582 & 100944 Starters MCCB protected 4-185kW 13582 & 100944 MCCB s 63-800A 13582 & 100944 ACB s 1200-4000A 13582 5000A 101539 Starters & MCCB s (415V) 6kV 100944 Starters & MCCB s (690V) 8kV 101539 Busbar System 16kV 100944 Operating Voltage 380-690V Insulating Voltage 690V 13582 1000V 100944 Form of Segregation Form 4 13582 & 100944 Verification of the effectiveness of protective circuit 100944 Verification of clearance and creepage distances 100944 Verification of the effective connection between exposed conductive parts of the assembly and the protective circuit 100944 Verification of dielectric properties after short circuit tests 13582 & 100944 Degree of protection Ip43 7048.1.D Ip55 7048.2.D

5. Product Guide Low Voltage Motor Control Centre ARC FAULT CONTAINMENT NOJA Power s LV MCCs form 3b and form 4 range of low voltage switchgear and control gear assemblies have been extensively type tested by Testing and Certification Australia to comply with the requirements of AS3439.1 Appendix EE. This is your guarantee of operator safety in the unlikely event of an internal arcing fault occurring during operation. The standard NOJA Power MCC product incorporates modules that are vented in the left hand side to allow ionised gases to expand during arcing. The module is also used to create a chimney to funnel ionised gases through a hinged cover in the roof of the switchgear and control assembly. A wide variety of internal arcing fault type tests on fuse protected circuits, MCCB protected circuits as well as Motor Starters have been conducted by Testing and Certification Australia, and prove the integrity of the NOJA Power MCC enclosure system under the most extreme fault conditions. TECHNICAL ILLUSTRATION Arc Fault Venting Chimney Withdrawable Motor Control Centre Components

NOJA Power Switchgear Pty Ltd 16 Archimedes Place, Murarrie, Qld 4172, Australia Distributor Phone: +61 7 3907 8777 Fax: +61 7 3399 6777 Email: sales@nojapower.com.au Website: www.nojapower.com.au NOJA Power and OSM are registered trademarks of NOJA Power Switchgear Pty Ltd. This document is copyright and is intended for users and distributors of NOJA Power Switchgear product. It contains information that is the intellectual property of NOJA Power Switchgear and the document or any part thereof should not be copied or reproduced in any form without written permission from NOJA Power Switchgear. NOJA Power Switchgear applies a policy of continued fundamental research and development and reserves the right to change designs and specifications of this product without notice. NOJA Power Switchgear does not accept any responsibility for loss or damage incurred by anyone as a result of acting or refrianing from action based on information in this Product Guide. NOJA-530-05