Mobile Heat Pump Exploration Using R445A and R744

Similar documents
Experimental Study of System Performance Improvements in Transcritical R744 Systems for Mobile Air-Conditioning and Heat Pumping

Low GWP Refrigerants for Air Conditioning Applications

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Refrigerant Mass and Oil Migration During Start-up Transient

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance of CO2 Cycles with a Two-Stage Compressor

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

A fair comparison of CO2 and propane used in light commercial applications featuring natural refrigerants

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Purdue e-pubs. Purdue University

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

HFO-1234yf Performance in a Beverage Cooler

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Experimental and Numerical Study of a Mobile Reversible Air Conditioning Heat Pump System Charge Imbalance when Switching Modes Paper #2569

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Control of FGB (Flash Gas Bypass) in Start-Up and Transients. Mr. Nemanja Dzinic, Pega Hrnjak CTS, USA & MPG-KGH d.o.o., Serbia

Air-Cooled Heat Exchanger Performance for R410A

Study of R161 Refrigerant for Residential Airconditioning

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Effects of Refrigerant-Lubricant Combinations on the Energy Efficiency of a Convertible Split-System Residential Air-Conditioner

Efficiency of Non-Azeotropic Refrigerant Cycle

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Control Method Of Circulating Refrigerant Amount For Heat Pump System

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Charge Minimization in Systems and Components Using Hydrocarbons as a Refrigerant

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

2015 DAVID JAMES KAISER

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Designated vs Non-designated Areas for Condenser Subcooling

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Experimental and Analytical Validation of New Approaches to Improve Transcritical CO 2 Environmental Control Units

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Sub-Critical Operation of the CO2 Expander/ Compressor

Design Optimization of Variable Geometry Microchannel Heat Exchangers

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

R32 Compressor for Air conditioning and Refrigeration applications in China

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Comparative Experimental Study of Subcritical R134a and Transcritical R744 Refrigeration Systems for Mobile Applications

Transcritical CO2 Bottle Cooler Development

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Conversion of platelet incubator refrigeration system to R600a and performance optimization

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

System Modeling of Gas Engine Driven Heat Pump

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

*Corresponding author;

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

High Efficiency R-134a Compressor for Domestic Refrigerator

Performance investigation of Air-conditioning system using ejector as expansion device

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 04 Mobile Heat Pump Exploration Using R445A and R744 Andrew Musser Creative Thermal Solutions, Inc., United States of America, andrew.musser@creativethermalsolutions.com Predrag S. Hrnjak Creative Thermal Solutions, Inc., United States of America, pega@creativethermalsolutions.com Follow this and additional works at: http://docs.lib.purdue.edu/iracc Musser, Andrew and Hrnjak, Predrag S., "Mobile Heat Pump Exploration Using R445A and R744" (04). International Refrigeration and Air Conditioning Conference. Paper 54. http://docs.lib.purdue.edu/iracc/54 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

509, Page Mobile Heat Pump Exploration Using R445A and R744 Andrew MUSSER *, Pega HRNJAK Creative Thermal Solutions, Inc. Urbana, IL, USA (7) 344-7663, andrew.musser@creativethermalsolutions.com * Corresponding Author ABSTRACT The increased usage of hybrid and electric vehicles where waste heat availability is limited has spurred research and development of mobile heat pump systems. Many options exist for heat pump system architectures and refrigerants to be used. Currently R34a use is prevalent in vehicle air conditioning systems but offers poor heat pump performance at low ambient temperatures. Two refrigerants will be explored in this paper, R744 and R445A. Both of these refrigerants are getting attention in vehicle A/C systems because of their relatively low GWP but each offers benefits over R34a in heat pump systems as well. Both refrigerants operate at higher pressures which improves the performance at low ambient temperatures in part due to higher compressor inlet refrigerant densities. R34a (and R445A to a lesser extent) also suffer from the drawback of going into sub-atmospheric pressure operation at temperatures commonly seen in vehicles. Data will be shown for multiple system architectures comparing these refrigerants to R34a. Advantages and disadvantages of each refrigerant will be shown. System control and optimization is important to get the maximum performance from each refrigerant and system. Control exploration will be presented for each alternative refrigerant.. INTRODUCTION Electric vehicle range is greatly limited in cold ambient conditions by the heating requirements for the cabin and batteries of the vehicle. The most prevalent form of heating in electric vehicles is electric resistance heat. The maximum coefficient of performance (COP), defined by the heating capacity divided by the power input, for resistance heating is. Implementing a heat pump system can more than double or triple the COP thus greatly increasing the driving range of an electric vehicle. Some electric vehicles on the road today have heat pumps or heat pump options such as the BMW i3, Renault Zoe, and Nissan Leaf. These heat pumps use low pressure refrigerants commonly used in vehicle air conditioning such as R34a and R34yf. Both refrigerants have the limitation of low performance and sub-atmospheric pressure operation at low ambient temperatures at or below -0 C. R34yf has been introduced as a drop-in alternative to R34a due to its low GWP (4 compared to 430). Another low GWP drop-in alternative, R445A (GWP of 35) has been explored and has advantages in heat pump operation due to higher pressures. R744 (GWP of ) has been shown to be the most promising fluid for heat pump operation among the refrigerants listed above but is not a drop-in due to the requirement for components able to withstand significantly higher pressures. Both R445A and R744 are under the European Union regulatory limit for GWP of 50 which is generally accepted worldwide as the threshold for classifying as low-gwp refrigerants. R445A is a ternary refrigerant mixture of R34ze(E), R34a, and R744 in the nominal proportions of 85%/9%/6% respectively. For the purposes of this study, it was not feasible to test with R445A, thus an alternative was used to simulate the properties of R445A. This alternative was chosen to consist of the same percentage of R744 at 6% with the balance being R34a (94%). The proportion of R34ze(E) in R445A is present to reduce the GWP and has similar performance to R34a thus replacing the R34ze(E) with R34a was not expected to have a large impact on the overall performance. The 94% R34a, 6% R744 blend will be referred to as the R34a/R744 blend for the purposes of simplicity in the remainder of this paper.

509, Page. EXPERIMENTAL FACILITY The test facility was designed based on the SAE Surface Vehicle Standard, J765; Procedure for Measuring System COP [Coefficient of Performance] of a Mobile Air Conditioning System on a Test Bench (SAE, 008). The facility consists of two environmental calorimeters. The outdoor environmental chamber simulated the ambient conditions experienced by the front end vehicle components of the system including the condenser (in A/C operation), internal heat exchanger, and compressor. The indoor chamber simulated the conditions experienced by the evaporator (in A/C mode) and the secondary condenser (in heat pump mode). Each chamber contained a wind tunnel designed according to ASHRAE standard 4. (ASHRAE, 987). In the case of both wind tunnels, the air passes through the heat exchangers, flow mixers, and then flow measuring nozzles. Thermocouples in the nozzle throat are then used in the airflow calculation as well as for the bulk air outlet temperature for each heat exchanger in the energy balance calculations. The setup was designed to replicate the actual relative heights of components in the vehicle. Figure shows a simplified chamber schematic set up for A/C mode. Testing was performed for R34a and the R34a/R744 blend in both A/C and heat pump operation. In the case of heat pump operation, the chambers were equipped with additional heat exchangers connected to a condensing unit capable of pulling both chambers down to -40 C. Three independent methods for calculating cooling or heating capacity were used which exceeds the requirement of independent methods in the SAE standard. The 3 methods used to determine capacity were the refrigerant side energy balance, air side energy balance, and a calorimeter energy balance where all energy entering and leaving the indoor calorimeter is measured with the balance being the capacity of the indoor heat exchanger. Indoor Chamber Outdoor Chamber Glycol Chiller Tgi Tgo Blower Diffusion Baffle Tdpen Ten Electric Heater Dew Point Sensor Air out NOZZLE 3" Diffusion Baffle Air mixer Teao grid P, T _eri P, T_xri Mr XV P, T_ero Indoor HX Teai Dew Point Sensor Tdpei P, T_cpri Comp Vcp, Acp P, T_cro P, T_cri P, T_cpro Tcai Outdoor HX Tcao grid Air mixer Diffusion Baffle 7" NOZZLE Tcn 7" Diffusion Baffle Chiller Blower DPen DPea Humidifier DPca DPcn Electric Heater Air out Figure : Experimental Facility * Drawing not to scale 3. A/C AND HEAT PUMP SYSTEM ARCHITECTURE AND COMPONENTS Many architectures for mobile heat pump systems were first evaluated. Wawzyniak (0) outlines several potential architectures which could be implemented in vehicles. The architecture shown in Figure and Figure 3 was chosen based on architectures used in production vehicles on the market today. Modifications to the current vehicle architectures were made in order to allow for additional laboratory exploration and to accommodate the limitations of available components. The design is based around adding a second heat exchanger in the cabin HVAC module. This heat exchanger functions as the condenser in heat pump operation. This eliminates the need to fully reverse the system and allows for the potential of using the indoor evaporator in heat pump operation for defogging purposes. Typically, in the vehicle the air flow is diverted through the secondary condenser only when heating is needed. In the case of the laboratory experiments, a refrigerant valve was added to bypass the refrigerant

509, Page 3 flow around the indoor condenser in addition to blocking the air flow in A/C operation. The components, which include the indoor and outdoor heat exchangers and electric compressor, were taken from a production hybrid midsize sedan. A cross-counterflow microchannel heat exchanger was chosen for the secondary condenser and electronic expansion valves were used for control exploration. A transparent accumulator was added in order to visualize the charge migration between heat pump and A/C modes as well as any problems with oil separation in heat pump mode. The production vehicle components used had been optimized for A/C operation with R34a and were used as a proof-of-concept for the R34a/R744 blend in heat pump operation. Many improvements could be made in future research to optimize the components for both A/C and heat pump operation with R445A as the refrigerant. R445A is a zeotropic blend which exhibits a temperature glide during evaporation and condensation. Thus, the use of counter flow heat exchangers is beneficial to take advantage of (or compensate for) the temperature glide. Figure : System Architecture in A/C Mode Figure 3: System Architecture in Heat Pump Mode

509, Page 4 4. EXPERIMENTATION AND RESULTS Experiments were performed in heat pump operation based on a test matrix in development for a proposed SAE heat pump standard as shown in Table. Ambient temperatures down to -0 C were explored, however, R34a experienced undesirable sub-atmospheric operation at -0 C thus -5 C test points were added in order to compare R34a and the R34a/R744 blend at the lower limits of R34a heat pump operation. Table : Heat Pump Test Matrix The two refrigerants were run at maximum compressor speeds for each condition within the limits of allowable compressor discharge temperature and while avoiding sub-atmospheric operation. The R34a/R744 blend produced 5% to 50% higher heating capacities at ambient temperatures of -0 C and below as shown in Figure 4. The R34a/R744 blend also produced capacities of approximately 3.5kW at -0 C where R34a could not reasonably operate. Figure 5 shows the corresponding COP values for the maximum capacity data points. The COP is defined by dividing the heating capacity by the compressor power which is sometimes referred to as the heating performance factor (HPF). Despite the much higher capacities for the R34a/R744 blend, the COP values were very close to R34a with the blend being on average 3% lower. The same low temperature conditions were run where the compressor speed was adjusted for the R34a/R744 blend to match the capacity of R34a. At equal capacities the R34a/R744 blend exhibited % to 9% higher COP results.

COP (-) Q (kw) 509, Page 5 6 5 4 3 0 H-0a M-0a L-0a H-5a M-5a L-5a H-0a M-0a L-0a H-0c M-0c L-0c Condition R34a Baseline R34a/R744 Blend Figure 4: Capacity Comparison Between R34a and R34a/R744 Blend.5.5 0.5 0 H-0a M-0a L-0a H-5a M-5a L-5a H-0a M-0a L-0a H-0c M-0c L-0c Condition R34a Baseline R34a/R744 Blend Figure 5: COP Comparison Between R34a and R34a/R744 Blend Control optimization was performed for the R34a/R744 blend by varying the electronic expansion valve and the compressor speed while maintaining all other conditions constant. The subcooling was increased while reducing the compressor speed to maintain a constant heating capacity as shown in Figure 6. As the subcooling increased the compressor power dropped and the COP increased.

509, Page 6 Figure 6: Control Optimization of the R34a/R744 blend at Condition M0a The above results show the favorable performance of R445A compared to R34a in heat pump operation. Significant study has been performed on R445A as a drop-in for air conditioning as part of a SAE cooperative research program: MAC Refrigerant Blend Cooperative Research Program (MRB CRP). The results have been presented in the white paper, Development and Evaluation of AC5 and AC6 Refrigerants for MAC Applications (SAE, 03). The study has shown that R445A as a drop-in has similar performance to R34a in A/C operation at high load conditions while there is a loss in COP of 5% to 0% at part load conditions. With the selection of an optimized internal heat exchanger and separated receiver it is possible to improve the A/C performance of R445A relative to R34a at part load and achieve equivalent or better performance relative to R34yf. Thus with R445A significant performance gains are achievable in heat pump operation while minor shortcomings in A/C operation have been observed. 5. R744 EXPERIMENTATION AND RESULTS Carbon Dioxide was first explored for use in automotive air conditioning in the 990s and early 000s as a replacement for R34a due to the greatly reduced global warming potential ( compared to 430). Despite comparable cooling capacities and COP values, R744 was eventually surpassed by new drop-in refrigerants such as R34yf which require very few changes on the component level compared to R744. Heat pump operation was explored as part of the initial A/C research for R744 at the University of Illinois Air Conditioning and Refrigeration Center (Musser 005) and those results have been revisited in this paper for comparison to R34a and the R34a/R744 blend. R744 has recently gained traction again in automotive air conditioning, specifically in Europe, due to flammability concerns with R34yf. If R744 is implemented for vehicle air conditioning, usage in vehicle heat pumps is expected to soon follow. R744 has been used in heat pumps for hot water heating beginning in the mid 990s and is prevalent in Japan. Use in commercial hot water heating is also being explored (Petersen et al, 0). R744 is also used in many other cooling applications on the market today ranging from light commercial to supermarket refrigeration. The experimental facility used for the automotive R744 heat pump exploration consisted of calorimeters and is similar in function to the facilities described above. The vehicle components used were designed for a mid-sized sedan as with the other refrigerants discussed but in this case a belt-driven compressor was used. The system consisted of components primarily designed for A/C operation and not optimized for use in heat pump operation. The system used only heat exchangers and is presented in heat pump configuration in Figure 7 below.

Heating Capacity [kw], COP [-] 509, Page 7 Pcro Mr Tori DPcr Tcro Tcri Outdoor Coil XV Tcro Tshro, Pshro Tshri, Pshri Mo Oil Separator Trcpo, Prcpo SLHX NV Suction Accumulator Pcc Comp NV Ml Tshri, Pshri Tshro, Pshro Tero3 Trcpi, Prcpi Tero Tero Indoor Coil Tero Teri Pero DPer Figure 7: R744 Heat Pump System The R744 heat pump was tested at several ambient temperatures going down to -40 C. At each ambient condition the indoor temperature was increased from the ambient temperature up to 0 C (in most cases) in a series of steady state points to simulate the warm up of the cabin as shown in Figure 8. All conditions shown in the figure were run at a worst-case compressor idle speed and higher capacities could be achieved at higher vehicle speeds (or compressor speeds in the case of an electric vehicle with variable speed electric compressor). R744 showed good heating capacity of 4kW to 5kW at each of the lowest indoor/outdoor temperature combinations where the greatest heating is needed. Comparing similar conditions of -0 C and -0 C between the 3 refrigerants yields similar heating capacities between the R34a/R744 blend and R744 with R744 being 0% higher at -0 C at 4kW compared to 3.6kW. As shown above, these are both significantly above the R34a capacity at approximately 30% higher at -0 C. The COP of the R744 heat pump was much higher than that of the other fluids. At -0 C the R744 COP was 3. compared to R34a and the R34a/R744 blend exhibiting COP values of approximately. At -0 C the R744 COP was nearly double that of the R34a/R744 blend at 3.4 compared to.8 respectively. 5 Ambient temperatures -0 C 0 C 4-0 C 3-40 C Q -Heating capacity COP 0-50 -40-30 -0-0 0 0 0 30 Indoor air temperature [ C] Figure 8: R744 Heat Pump Results

509, Page 8 Control optimization was also performed on the R744 heat pump system. Unlike the hybrid system with a variable speed electric compressor used with the low pressure fluids, the belt driven compressor used for the R744 experiments had a fixed speed dependent on the simulated vehicle speed. The most influential control variable explored was the expansion valve. Park et al. (999) have shown using similar systems that maximum COP and capacity can be obtained for a transcritical R744 mobile A/C system by regulating high-side pressure. A relationship between maximum COP and high-side pressure was determined based on Park s study. Giannavola (00) further showed capacity and COP/HPF maximums were obtainable by regulating high side pressure in both A/C and H/P transcritical operation. The study presented here and originally shown by Musser (005) extended this work to low temperatures where subcritical operation is expected for the heat pump system. Figure 9 shows high side pressure control exploration for -0 C ambient temperatures and multiple indoor air temperatures. As expected, the compressor power increases as the pressure increases. However, due to the loss of compressor efficiency at higher pressure ratios, the refrigerant mass flow rate and evaporator capacity reaches a maximum and then begins to drop. The initial evaporator capacity increase is due to increased subcooling caused by better condenser performance from higher temperature difference between refrigerant and air side but the loss in mass flow eventually outweighs the gains. The condenser or heating capacity is the sum of the compressor power and evaporator capacity thus it increases to the point at which the evaporator capacity loss becomes greater than the compressor power addition. This heating capacity maximum occurs at subcritical pressures for indoor temperatures of -0 C and -0 C for the -0 C ambient condition. The COP/HPF maximums occur at lower pressures than the capacity maximums due to relatively low heating capacity gains compared to the elevated compressor power input as the pressure increases. Thus, there is a trade-off between maximizing heating capacity and efficiency in subcritical operation and at these low temperatures capacity would likely be chosen over efficiency during the initial warm-up period.

Heating Capacity (kw) Evaporator Capacity (kw) Compressor Work (kw) Heating Capacity (kw) HPF Air temperat indoor c 0 0 0 4000 4500 5000 5500 6000 6500 7000 7500 8000 6 5 4 Compressor speed = 070 rpm Toutdoor = -0 C AFRoutdoor = 6.9 m 3 /min AFRindoor = 7. m 3 /min 509, Page 9 3 4000 4500 5000 5500 6000 6500 7000 7500 8000.56.35.4 0.93 0.7 Compressor speed = 070 rpm Toutdoor = -0 C AFRoutdoor = 6.9 m 3 /min AFRindoor = 7. m 3 /min Tindoor 0 C Tindoor 0 C Tindoor -0 C Tindoor-0 C 0.5 4000 4000 4500 4500 5000 5000 5500 5500 6000 6000 6500 6500 7000 7000 7500 7500 8000 8000 3 Indoor coil exit pressure (kpa).5 Compressor speed = 070 rpm Toutdoor = -0 C AFRoutdoor = 6.9 m 3 /min AFRindoor = 7. m 3 /min.5 Compressor speed = 070 rpm Toutdoor = -0 C AFRoutdoor = 6.9 m 3 /min AFRindoor = 7. m 3 /min 0.5 0 4000 4500 5000 5500 6000 6500 7000 7500 8000 6 5 4 Compressor speed = 070 rpm Toutdoor = -0 C AFRoutdoor = 6.9 m 3 /min AFRindoor = 7. m 3 /min 3 4000 4500 5000 5500 6000 6500 7000 7500 8000 Indoor coil exit pressure (kpa) Figure 9: High Side Pressure Control Exploration at -0 C Ambient

509, Page 0 6. CONCLUSIONS Electric vehicle range is largely dependent on heating loads in the winter months. Currently R34a and R34yf are being used in heat pumps in vehicles on the market. Considerable improvements in heating performance have been shown in this paper for the R34a/R744 blend and R744. The R34a/R744 blend exhibits 5% to 50% higher heating capacities compared to R34a for the conditions tested at -0 C and below while maintaining comparable COP values. R445A has marginally lower performance in A/C operation compared to R34a and is overall a good option for A/C-HP systems based on performance. R744 shows equal or greater capacities compared to the already strong R34a/R744 blend results at -0 C and -0 C despite only operating at idle compressor speeds. At the equal or greater capacities, R744 exhibits much higher COP values up to nearly double that of the R34a/R744 blend at - 0 C. Heat pump performance alone will likely not drive the adoption of R445A or R744 in vehicles but the European Union regulations for GWP below 50 combined with flammability concerns for R34yf may lead to adoption of one of these refrigerants opening the door for improved heat pump performance. REFERENCES ASHRAE Standard 4., 987, Standard Methods for Laboratory Airflow Measurement Giannavola, M.S., 00, Experimental Study of System Performance Improvements in Transcritical R744 Systems for Mobile Air-Conditioning and Heat Pumping, Univ. of Illinois at Urbana-Champaign Master s Thesis. Musser A.M., 005, Control Issues in Transcritical R744 Systems for Mobile Air-conditioning and Heat Pumping with Variable Displacement Compressors, Univ. of Illinois at Urbana-Champaign Master s Thesis. Park, Y.C., Yin, J.M., Bullard, C.W., Hrnjak, P.S., 999, Experimental and Model Analysis of Control and Operating Parameters of Transcritical CO Mobile A/C System, Vehicle Thermal Mgt. Systems Conf., London Petersen, M., Bowers, C.D., Elbel, S., Hrnjak, P. S., 0, Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater, Int. Ref. and Air Cond. Conf, Purdue, West Lafayette, IN SAE, 03, Development and Evaluation of AC5 and AC6 Refrigerants for MAC Applications SAE Surface Vehicle Standard J765, 008, Procedure for Measuring System COP [Coefficient of Performance] of a Mobile Air Conditioning System on a Test Bench Wawzyniak, M., 0, Quantitative Analysis of Heat Pump Systems, SAE Automotive Alternate Refrigerant Systems Symposium, Scottsdale, Arizona