Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

Similar documents
Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Precision Infrared Thermometer. Users Manual

Manual PCE-889 pyrometer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Precision Infrared Thermometer. Users Manual

MicroRay IR-100 NEW. Inspection MicroRay IR-100

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

IRT2 Dual Laser IR Thermometer - User Guide

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Datalogging as standard

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

intrinsically safe detector for hydrocarbon gases

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Users Manual. Visit us at

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

GAS ANALYSIS / DETECTION Gas Detector

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

R2310. Infrared Thermometer. Instruction Manual

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Dräger X-am 7000 Multi-Gas Detection

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

TOOLS AND INSTRUMENTS

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Beamex. Calibration White Paper. Calibration in hazardous areas

LIST OF STANDARDS S. NO. STANDARD NO. STANDARD NAME. Recommended Practices on Oil Storage and Handling OISD-STD-109

Instruments. for hydroponics & horticulture 2016

LIST OF OISD STANDARDS (April 2016)

Notice of Proprietary Rights

Safe Operation Manual. Honeywell IQ Force Gas Detector

Monitores Personales. Personal Monitor

Sieger Apex. Flexibility that meets your requirements

Understanding Hazardous Locations Concepts

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Guide to Intrinsically Safe Portable Radios

62 MAX/62 MAX + Infrared Thermometer. Users Manual

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Beamex Calibration White Paper. Calibration in hazardous areas

T.ex Single Gas Detector VISA

62 MAX/62 MAX + Infrared Thermometer. Users Manual

onlinecomponents.com

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

ALTAIR 5X Multigas Detector

CO warning instruments and gas spillage detectors

99 Washington Street Melrose, MA Phone Toll Free Visit us at

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

GasAlertMicroClip X3 Specifications

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

For the Safety of Your

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

ALTAIR 5X Multigas Detector Product Specification

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Infrared Thermometer. Getting Started

Model GP-01 Combustible Gas Monitor Operator s Manual

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Infrared Thermometer

Choosing the best confined space gas detector

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

I/R Thermometer Gun 12:1

Nanotechnology-Based Gas Sensors

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

ALTAIR 5X Multigas Detector

Dew-Point Transmitters and Instruments

GX-2009 Portable Gas Monitor Operator s Manual

IT S WHAT S INSIDE THAT

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

IT S WHAT S INSIDE THAT COUNTS

562/563. Infrared Thermometers

Smoke detection in hazardous areas:

Innovative Technology for Traditional and Challenging Applications

PROTÉGÉ ZM SINGLE GAS MONITOR

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

RS Pro Infrared Temperature Sensor

G-TECTA TM. Portable Gas Detection Instruments

Transcription:

RAYNGER ST 20 PRO THE PROFESSIONAL S CHOICE FOR VALUE AND PRECISION Raytek s ST20 Infrared Non-Contact Thermometers offer accurate readings in a compact and reliable design. The ST20 Pro has a temperature range of -25 to 999 F (-32 to 535 C), a 500 msec reading response time and a weight of 11 ounces. This thermometer is safe to use as it requires no contact with the surface measured so long as it is within the thermometer s range (D:S=12:1). With the ST 20 s extra-bright single-point laser sighting, MAX temperature displays and rugged rubber over molding, it can prevent downtime by permitting preventative and predictive maintenance by simply pointing, shooting and reading temperature measurements. This thermometer is perfect for automotive and diesel applications, facility maintenance, fire safety, marine maintenance, electrical and industrial, asphalt work and HVAC systems; and these are just a few of the applications in which the ST20 can be utilized. Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications Automotive and Diesel HVAC/R Systems Electrical and Industrial Facility Maintenance Food Safety Asphalt Work Fire Safety Marine Maintenance ST20 Pro with laser -25 to 750 F (-32 to 400 C); F/ C, backlight ST 20 TARGET SPOT SIZES

RAYNGER ST 60/80 PRO PLUS POINT, SHOOT AND READ: INFRARED NON-CONTACT THERMOMETER The simple operation sequence of point, shoot and read is what makes gathering temperature data easier than ever with Raytek s ST60 and ST80 Pro Plus Infrared Non-Contact Thermometers. The ST60 has a temperature range of -25 to 1100 F (-32 to 600 C) and the ST80 has a temperature range of -25 to 1400 F (-32 to 760 C). Both have a response time of 500 msec (95% of reading) and a weight of 11 ounces. Suited to the most demanding applications, these non-contact infrared thermometers include innovative features like extra-bright singlepoint laser sighting, a wide temperature range and 12-point datalogging. The units are rugged and durable, and include a jack for an RTD temperature probe. Both the ST60 and ST80 can be tripod-mounted for hands-free operation. Facility maintenance, HVAC systems, food safety, electrical and industrial, and marine maintenance are just some of the areas in which these thermometers can be employed. Powered by 9V alkaline or NiCad batteries, Raytek s ST60 s and ST80 s target spot sizes at focus point are D:S=30:1 and D:S=50:1 respectively. Wide temperature range Powerful optics 12-point datalogging Max temperature display Tripod mountable Includes jack for an RTD temperature probe Applications Automotive and Diesel HVAC/R Systems Electrical and Industrial Facility Maintenance Food Safety Asphalt Work Fire Safety Marine Maintenance ST60 Pro Plus -25 to 1100 F (-32 to 600 C); datalogging ST80 Pro Plus -25 to 1400 F (-32 to 760 C); datalogging ST 60 TARGET SPOT SIZES ST 80 TARGET SPOT SIZES

RAYNGER ST 80-IS PRO PLUS ALL THE FEATURES OF THE ST80 PLUS AN INTRINSICALLY SAFE RATING Intrinsic Safety is a technique for preventing explosions in hazardous areas. Intrinsic safety is achieved by limiting the energy and surface temperature of a device during normal operation, or during foreseeable fault conditions, to an insufficient level to ignite an explosive environment. The presence of dusts, gases, grains, and fibers are some of the factors that can lead to ignition. An Intrinsically Safe rating is earned by passing the rigorous approval process of a recognized entity. Upon approval, the exact approved hazardous situations are displayed on the label attached to the unit. Factory Mutual is one of the most recognized approving organizations in North America. Its approval is accepted in many parts of the world (checking with the end-user customer is the only way to be sure outside North America). Certification from TUV is the most common approval in Europe. The ST80-IS does not have TUV approval and it is not currently planned. The Professional s Choice for: Hazardous Locations, Fire Safety, Electrical and Industrial, Automotive and Diesel, HVAC/R Systems, Facility Maintenance, Food Safety, Asphalt Work and Marine Maintenance FM approval of Intrinsically Safe Can get portable noncontact temperature measurements in many hazardous locations. For most customers, the ST80-IS will be the only means to do this! Brings all the benefits of noncontact temperature measurement including speed, safety, convenience, to hazlocs (hazardous locations) Extra Bright Laser Point Sighting Visible in all conditions, especially outdoors 1%/1 F (2 C) Accuracy at Normal Operating Ambient Ideal for use in critical monitoring applications (steam traps, relief valves, furnaces, boilers, sewers) Long-Range (50:1) Optical Resolution (D:S) Allows measurement of smaller targets at longer distances (e.g. inch/cm scale targets at 10 ft/3 m). Often eliminates need for climbing, reaching in dangerous areas. Increases safety Sub-Zero (-25 F/-32 C) & Hi-Temp (1400 F/760 C) Range Capability Increases instrument versatility and application capabilities at variety of temperature ranges found in chemical processing and other hazardous locations 500 msec Response Time Accurate readings when target temperature is changing rapidly. Improved response when using instrument to sweep wide target regions. Dangerous problems can be seen instantly Rubberized Grip; Overmolded Nose/Back Rugged less prone to dropping. Improved shock resistance. Resistant to common chemicals, such as, gasoline FM approved RTD probe included Ability to do both contact and noncontact temperature measurement in hazardous locations with one product. Closely adjust emissivity on site. Measure intake and outlets simultaneously Twelve point data logging Accurately record several key temperatures for subsequent analysis in a nonhazardous area

ST 80-IS PRO PLUS, CONTINUED Who Can Benefit By Using This Intrinsically Safe Device? Petrochemical refineries and tank farms Oil exploration, especially offshore drilling rigs Pumping stations for petroleum and gas Solid propellant manufacture Chemical/ pharmaceutical plants Ink, laminate, and coating processes that emit volatile vapors Fire departments in situations where flammable gases can be present Hazardous waste disposal and sewage Aviation fueling and maintenance (also, any refueling situation for rail, auto, ship) Liquid natural gas storage Arms manufacture and storage Boiler rooms Hydrogen generating facilities INTRINSICALLY SAFE APPROVAL DETAILS All Intrinsically Safe Approved equipment must carry a label that specifies exactly where it can be used and the name of the testing laboratory. The exact approval language can be very important for a customer determining if a particular application is covered by the FM Intrinsically Safe approval. The label on the side of the ST80-IS reads: FM Approved. Intrinsically Safe, Class I, Division 1, Groups A, B, C, D. Class I, Zone 0, AEX ia IIC, T4 at 50C when used with 9v alkaline battery. This language means that the ST80-IS can be used where flammable material is present continuously and in the presence of acetylene, hydrogen, ethylene or propane gases at a maximum temperature of 135 C (though Raytek specifies a maximum ambient temperature of 50 for reliable thermometer operation). The rating does not apply to coal dust, grain dust, metal dust, or fibers.

RAYNGER ST SERIES SPECIFICATIONS ACCURACY REPEATABILITY RESPONSE TIME AMBIENT OPERATING RANGE POWER DIMENSIONS WEIGHT OPTIONS/ACCESSORIES ±1% of reading or ±2 F (±1 C), whichever is greater, at 73 F (23 C) ambient temperature ±0.5% of reading or ±2 F (±1 C), whichever is greater (95%) 500 msec 32 to 122 F (0 to 50 C) 9V Alkaline or NiCad battery 8 x 6 x 2 in. (200 x 160 x 55 mm) 11 oz. (320g) Hard Case and Wrist Strap (standard) Nylon Holster with Belt Clip NIST/DKD Certification Contact Probe (ST60/80) ST20 ST60 ST80 TEMPERATURE RANGE -25 to 999 F -25 to 1100 F -25 to 1400 F (-32 to 535 C) (-32 to 600 C) (-32 to 760 C) DISPLAY RESOLUTION 0.5 F (0.2 C) 0.1 F/C 0.1 F/C MAX, MIN, DIF AND AVG TEMPERATURE No Yes Yes RECALL LAST READING No Yes Yes DISPLAY HOLD Yes Yes Yes HIGH AND LOW AUDIBLE AND VISIBLE ALARMS No Yes Yes LCD BACKLIGHT Yes Yes Yes LASER (CLASS II)* Yes Yes Yes EMISSIVITY Pre-set 0.95 0.1 to 1.0 0.1 to 1.0 digitally adjustable digitally adjustable CONTACT PROBE INPUT No Yes Yes DISTANCE TO SPOT RATIO 12:1 30:1 50:1 RAYNGER ST ORDERING INFORMATION RAYST20XBUS Raytek s ST20 Pro infrared non-contact thermometer RAYST20XBCRUS Raytek s ST20 Pro infrared non-contact thermometer with NIST certification RAYST60XBUS Raytek s ST60 Pro Plus infrared non-contact thermometer RAYST60XBCRUS Raytek s ST60 Pro Plus infrared non-contact thermometer with NIST certification RAYST80XBUS Raytek s ST80 Pro Plus infrared non-contact thermometer RAYST80XBCRUS Raytek s ST80 Pro Plus infrared non-contact thermometer with NIST certification RAYST80XBISUS Raytek s ST80 Instrinsically Safe Pro Plus infrared non-contact thermometer RAYST80XBISCRUS Raytek s ST80 Instrinsically Safe Pro Plus infrared non-contact thermometer with NIST certification ACCESSORIES XXXSTACHC XXXSTACSC XXXSTACPR Spare hard case Nylon holster-style case RTD contact probe