TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Similar documents
TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

GridScan/Mini. Installation and Operation Manual. English Pages 1 14 Deutsch Seiten Français Pages Español Páginas 41 53

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Laser Collimated Beam Sensor

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

RSMFM-2R MULTIFUNCTIONAL

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Laser Distance Sensor Type M Analog-Output

OPTISENS TUR 2000 Technical Datasheet

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

onlinecomponents.com

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Commercial Series TriTech Motion Detector. Reference Guide

2 General Application Photoelectric Sensors

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

General Purpose Photoelectric Sensor

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Square D Clipsal Outdoor Light-Level Sensor

Phone: Fax: Web:

SENSOR SOLUTIONS FOR DOORS

SENSOR SOLUTIONS FOR DOORS

ILLUMINATORS SIL SERIES INDUSTRIAL ILLUMINATORS

DT1101A / DT1102A / DO110xA Automatic fire detectors

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Snifter ATEX22 VERSION. User Manual. Distributor

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Automatic Self-Adjusting General Purpose Sensor

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

General Specifications

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

4 & 8-POINT ANNUNCIATORS Instruction Manual

DMFPM-2R MULTIFUNCTIONAL

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Applications PL- N Series Lens Type Sensor Type Serial Number

GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

2 General Application Photoelectric Sensors

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

Knürr RMS Compact II. Knürr RMS Compact II 2.81

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Operating Manual MS220DA

O P Style Meter with Optical Sensor Switch

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

RL-S EuroBrite Ring Light

RE-PR3-E-27 3-Phase Panel Mount 27kW

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

/ / 2018

2 Specialty Application Photoelectric Sensors

LED Flood 50W LED floodlight. user manual

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

R2310. Infrared Thermometer. Instruction Manual

The Affordable, All-Purpose Sensor That's EZ To Use!

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Installation and Operation Manual

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

CEILING SPEAKER SYSTEMS F-2352CU2

UNIVERSAL COMPACT SENSORS

INSTRUCTION MANUAL. Handy Controller Exclusive for SF4B / SF4B<V2> Series. SFB-HC Ver.2.1 FUNCTION CANCEL ENTER

XPSLCM1150 Safety light curtains mute module User s Manual

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

North Dakota State University Laser Safety

Open-area Smoke Imaging Detection (OSID)

SPACEMOTION SERIES SMM 01

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Sintrol Snifter A1+ Manual. Version 1.2.2

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

BL-S EuroBrite Backlight

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

CEILING SPEAKER SYSTEM

E3FA PHOTOELECTRIC SENSORS

CMF, CMX & CMA series

Retro-reflective Sensing range: 0mm to 2000mm

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

CEILING SPEAKER SYSTEM

Duct Air Quality Sensors

Datasheet: K-22 LO Sensor

Increased safety and reducing energy consumption with the motion control RPI 01

SENSOR SOLUTIONS FOR DOORS

Transcription:

Installation and Operation Manual RoHS CEDES AG is certified according to ISO 9001: 2008 English Pages 2-12 111 189 130208 V 1.0

Contents 1. About this manual 2 1.1 Measurements 2 1.2 Related documents 2 1.3 CEDES headquarters 2 2. Safety information 3 2.1 Non-intended use 3 3. Symbols, safety messages 3 3.1 Safety message categories 3 4. Introduction 4 4.1 Features of the TLS 600 4 4.2 Type description 4 5. Overview 5 5.1 Delivery package 5 5.2 TLS 600 product overview 6 5.3 Detection area dimensions 6 6. Configuration 6 6.1 Background influence 6 7. Installation 7 8. Electrical connection 8 8.1 Semiconductor output 8 8.2 Test input 8 9. Timing diagram 9 10. Start-up 9 10.1 Test run 9 11. LED signals 10 12. Sensor recalibration 10 13. Troubleshooting 10 14. Maintenance 10 15. Disposal 10 16. Technical data 11 17. Dimensions 12 17.1 Mounting bracket scaled plan 12 1. About this manual This 'TLS 600 Installation and Operation Manual', with metric and US measurements is the original version. The version number is printed at the bottom of each page. To make sure you have the latest version, visit www.cedes.com from where this manual and related documents can be downloaded. 1.1 Measurements Unless stated otherwise, measurements are given in mm (non-bracketed numbers) and inches (numbers in brackets). 1.2 Related documents TLS 600 datasheet en incl. ordering information Part No. 001 193 en TLS 600 Quickguide en de fr it es pl zh Part No. 112 016 1.3 CEDES headquarters CEDES AG Science Park CH-7302 Landquart Switzerland 2 CEDES AG reserves the right to modify or change technical data without prior notice. CEDES V 1.0

English 2. Safety information IMPORTANT! READ BEFORE INSTALLATION! The TLS 600 was developed and manufactured using state-of-the-art systems and technologies. However, injury and damage to the sensor can still occur. To ensure safe operating conditions: Read all enclosed instructions and information. Follow the instructions given in this manual carefully. Observe all warnings included in the documentation and attached to the sensor. Do not use the sensor if it is damaged in any way. Keep the instruction manual on site. The TLS 600 should only be installed by authorized and fully trained personnel! The installer or system integrator is fully responsible for the safe integration of the sensor. It is the sole responsibility of the planner and/or installer and/or buyer to ensure that this product is used according to all applicable standards, laws and regulations in order to ensure safe operation of the whole application. Any alterations to the device by the buyer, installer or user may result in unsafe operating conditions. CEDES is not responsible for any liability or warranty claim that results from such manipulation. Failure to follow instructions given in this manual and/or other documents related to the TLS 600 may cause customer complaints, serious call backs, damage, injury or death. 2.1 Non-intended use The TLS 600 must not be used for: The safeguarding of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications, otherwise serious injury or death or damage to property may occur! 3. Symbols, safety messages Symbol 1. 2. 3. Meaning Single instruction or measures in no specific order Instructions in specific order List, in no order of importance Reference to a chapter, illustration or table within this document Important: Important information for the correct use of the sensor 3.1 Safety message categories Warning of serious health risks WARNING Serious health risks Highlights critical information for the safe use of the sensor. Disregarding these warnings can result in serious injury or death. Follow the measures highlighted by the triangle-shaped arrows Consult the safety information in Chapter 2 of this manual Caution of possible health risks CAUTION Possible health risks Highlights critical information for the safe use of the sensor. Disregarding these warnings can result in injury. Follow the measures highlighted by the triangle-shaped arrows Consult the safety information in Chapter 2 of this manual Notice of damage risk NOTICE Risk of damage Disregarding these notices can lead to damage to the sensor, the controller and/or other devices. Follow the measures highlighted by the triangle-shaped arrows CEDES V 1.0 3

4. Introduction There is a rapidly-increasing global trend towards improving accessibility for elderly and disabled people within buildings using automatic doors. The TLS 600 offers the perfect solution. Its wide detection area and ultra reliable operation make it the ideal choice as door sensor. With aesthetics playing an increasing role in architectural design, the TLS 600 s compact and elegant design allows it to easily blend into all types of door frames. The TLS 600 is the ideal door-opening sensor for automatic doors. It offers a larger, elliptical-shaped detection area to ensure effective detection of approaching people and/or objects. At a typical mounting height of 2.3 m (7.5 ft), a single TLS 600 provides a 1 m 0.3 m (3.3 ft 1 ft) monitored area, providing reliable door-opening for sliding doors, including telescopic sliding doors. It measures 62 18 32 mm (2.4 0.7 1.3 in) with the mounting bracket discreetly merged into the sensor housing. This elegant design allows it to blend in perfectly with any application s surroundings. Easy mounting and alignment, combined with robust construction and automatic blanking of stationary objects, means the TLS 600 offers a very impressive price/performance ratio. 4.1 Features of the TLS 600 Intelligent, infrared-based diffuse-reflective sensor Excellent detection capability PNP or NPN output Small and sleek design Plug-and-play Operating range up to 4 m (13 ft) Easy mounting Insensitive to direct sunlight up to 100,000 Lux 4.2 Type description TLS 600 x xxx xx Output logic LO Light on DO Dark on Output type PNP NPN Figure 2: TLS 600 type description Sensor type P Adjustable recalibration time Figure 1: A typical TLS 600 application environment 4 CEDES V 1.0

English 5. Overview The TLS 600 measures the reflection from objects compared with background reflection. Any change in the values is detected as an object and the output switches. During startup the TLS 600 takes a background light measurement and saves this as a reference value. When an object enters the detection area, the reflection value changes. The bigger the difference in light reflection between the object and the background, the easier it is to detect said object. High contrast between objects and background results in high sensitivity. CAUTION Damage to the eye Although the TLS 600 does not emit dangerous amounts of infrared light, long exposure to intense infrared light sources can result in damage to the eyes. To avoid any risks: Never look directly into the active infrared emitter from a close distance. Figure 3: TLS 600 in angeled mounting monitoring the approach area of a sliding door Figure 4: TLS 600 in vertical mounting monitoring the closing area of a sliding door 5.1 Delivery package Typical delivery package contains: 1 TLS 600 sensor 1 mounting bracket 2 mounting screws 1 blue screwdriver 1 quick installation guide Figure 5: TLS 600 components CEDES V 1.0 5

5.2 TLS 600 product overview 6. Configuration 2 3 4 NOTICE Mechanical damage to the TLS 600 Do not turn the potentiometer beyond its mechanical limit 1 The recalibration time can be adjusted from 3 s up to 180 s by turning the potentiometer. Recalibration time means the time until an immobile person or object is accepted by the sensor as background. 5 10 s 30 s 60 s Figure 6: TLS 600 overview 6 1 Mounting bracket 2 TLS 600 sensor 3 Potentiometer 4 Connection cable 5 Adjusting screw 6 Optical window 5.3 Detection area dimensions The detection area dimensions of the sensor depend on the distance to the object or background. All measurements in mm (normal numbers) and inches (in brackets). 2000 mm (6.6 ft) 3 s 180 s Figure 8: Configuring the TLS 600 P-type (in seconds) 6.1 Background influence TLS 600 has a maximal operating range of 4 m (13 ft) on Kodak white. However, different floor materials and colors influence the effective operating range. See table below for reference. Material Kodak white Bright wood Brown cardboard Kodak grey Bright concrete Dark carpet Max. detection range 4 m (13 ft) 2.8... 3.2 m (9... 10.5 ft) 2.8... 3.2 m (9... 10.5 ft) 2.4 m (8 ft) 2.4... 3.2 m (8... 10.5 ft) 1.2... 2 m (4... 6.5 ft) Applies only when beam axis is perpendicular to surface 860 mm (2.8 ft) 280 mm (11 in) Figure 7: Detection area dimensions at 2 m (6.6 ft) 6 CEDES V 1.0

English 7. Installation WARNING Electrical and mechanical hazards Electrical shock and unexpected mechanical movement can cause serious injury or death. Before installing and configuring the TLS 600 make sure the controller and all relevant devices are powered off Use only specific and approved tools Follow all applicable safety measures Do not over-tighten the mounting screws Do not drill holes into the TLS 600 If the TLS 600 must be readjusted, the main power supply must be switched off and marked as out of service 4. Set the recalibration time by adjusting the potentiometer using the screwdriver provided Chapter 6. 3... 180 s Figure 11: Potentiometer adjusting on TLS 600 5. Snap the TLS 600 into the mounting bracket. Carry out the system installation according to the following steps: 1. Switch off main power for the installation area and mark it clearly with OUT OF SERVICE. 2. Turn the adjusting screw to vertical position using a screwdriver. Figure 12: Snapping on the TLS 600 mounting bracket 6. Set the alignment of the TLS 600 by turning the adjusting screw until the correct angle is set. Figure 9: Turn the adjusting screw to vertical position 3. Fix the mounting bracket onto to the chosen location using the mounting screws. 15 mm (0.6 in) 7.5 mm (0.3 in) Ø 4.2 mm (0.16 in) Ø 3.6 mm (0.14 in) Ø 4.2 mm (0.16 in) 0... 20 Figure 10: Mounting bracket fixing Figure 13: Adjusting the alignment of TLS 600 7. Connect the other end of the cable (open wires) to the controller. For detailed controller wiring Chapter 8. 8. Verify your settings by switching on the power and performing a test run Chapter 10.1. CEDES V 1.0 7

8. Electrical connection TLS 600 USP (10... 30 VDC) GND (0 VDC) brown blue Controller Output black Test input white If no test signal is available, connect the white wire to USP Figure 14: TLS 600 connection diagram 8.1 Semiconductor output 8.2 Test input The TLS 600 is available as a PNP or NPN version with either a dark-on (DO) or light-on (LO) type. The DO output is ON when an object or person is detected, OFF if the detection area is free. The LO output is OFF when an object or person is detected, ON if the detection area is free Chapter 9. TLS 600 performs a test cycle as follows: The illumination is switched off and the sensor recognizes the change and switches the output. Important: Please be aware that the TLS 600 must always have a background (floor). NOTICE Possible damage to the semiconductor output PNP outputs need a pull-down resistor (10... 47 kω) NPN outputs need a pull-up resistor (10... 47 kω) 8 CEDES V 1.0

English 9. Timing diagram Power supply Object detection Test input HIGH LOW Object No object HIGH LOW Test active Output PNP-LO / NPN-DO Output PNP-DO / NPN-LO HIGH LOW HIGH LOW t 1 t 2 t 3 t 5 t 4 Figure 15: TLS 600 timing diagram Time Value Power-up time t 1 < 150 ms Response time t 2 < 150 ms Release time t 3 < 150 ms Response time test input t 4 < 150 ms Value Output HIGH USP - 4 V Output LOW < 4 V Table 2: TLS 600 value table Time at test t 5 > t 4 Table 1: TLS 600 timing table 10. Start-up 1. Switch on mains and/or power up the controller. 2. Check if LED lights up Chapter 11. 3. Perform a test run with the controller using the test input Chapter 10.1. 10.1 Test run It is recommended to perform a test run with the controller: 1. Switch the test input to LOW. 2. Check the output s response Chapter 9. Important: Check the detection area of the sensor. If adjustments to the sensor calibration are needed, switch off main power and/or the controller again for your own safety. CEDES V 1.0 9

11. LED signals 13. Troubleshooting The TLS 600 uses a red LED to indicate its status. LED glows brightly LED glows softly LED blinks Table 3: LED signals 12. Sensor recalibration Object detected No object detected Reflective background The TLS 600 cannot differentiate between an object and a person. Therefore any object entering the detection field is also detected. When an object or person does not move for more than the set recalibration time, the TLS 600 accepts this object as background and switches the output back to No object detected. dim red bright red Sensor status Object is in detection area but the LED indicates 'no object' No LED visible LED is blinking Detection area is free but the LED displays object detected Action Check the sensors detection capability in relation to the background influence Chapter 6.1 Check electrical connections Make sure that the sensor is not facing a reflective background and no other light sources interfere Make sure ambient light is stable and no other light sources interfere Check if the sensor is inactivated from permanent test signal Wait for the chosen recalibration time and then check if the sensor works normally If a problem persists, please contact your local CEDES representative. Visit www.cedes.com for contact data. 14. Maintenance bright red dim red < t Recalibration > t Recalibration Although the TLS 600 does not need regular maintenance, a periodical functional check is strongly recommended as follows: Check the mounting position and detection area of the sensor. Clean the optical window with a soft towel and a little soapy water. Figure 16: Sensor recalibration NOTICE Damage to the optical window Never use any solvents, cleaners or mechanically abrasive towels or highpressure water to clean the sensor. 15. Disposal The TLS 600 should only be replaced if a similar protection device is installed. Disposal should be carried out using the most up-to-date recycling technology according to local regulations and laws. There are no harmful materials used in the design and manufacture of the sensor. Traces of such dangerous materials may be found in the electronic components but not in quantities that are harmful. 10 CEDES V 1.0

English 16. Technical data Optical Max. operating range (on Kodak white) Detection area at 2 m (6.5 ft) distance Min. distance to background Adjustable recalibration time Max. ambient light 4 m (13 ft) 860 mm 280 mm (34 in 11 in) 0.2 m (7.9 in) 3... 180 s 100,000 Lux Mechanical Dimensions (w h d) 62 18 32 mm (2.4 0.7 1.3 in) Housing material Polycarbonate, ABS Housing color Black Enclosure rating IP40 Temperature range 20 C... +60 C ( 4 F... +140 F) Mounting bracket - angle adjustment 0... 20 Electrical Supply voltage USP Max. current consumption at 24 VDC Output Max. response time 10... 30 VDC 40 ma PNP or NPN 150 ms Connection cable and electrical connection Length 2 m Diameter Ø 3.4 mm (0.13 in) Material PVC, black Wires AWG26 brown USP (10... 30 VDC) blue GND (0 V) black Output white Test input General EMC emission EN 61000-6-3:2007 EMC immunity EN 61000-6-2:2005 Shock EN 60068-2-27:2009 Vibration EN 60068-2-6:2008 RoHS 2011/65/EU Certificate CE CEDES V 1.0 11

English 17. Dimensions Metric measurements (all dimensions in mm) 62.6 18.7 25.2 32.6 34.3 Figure 17: TLS 600 dimensions (metric) US measurements (all dimensions in inches) 2.5 0.74 1.0 1.3 1.35 Figure 18: TLS 600 dimensions (US) 17.1 Mounting bracket scaled plan Dimensions in mm and inches (in brackets) and to scale 15 mm (0.6 in) 7.5 mm (0.3 in) Ø 4.2 mm (0.16 in) Ø 3.6 mm (0.14 in) Ø 4.2 mm (0.16 in) CEDES AG, Science Park CH-7302 Landquart Phone: +41 81 307 2323 Fax: +41 81 307 2325 info@cedes.com www.cedes.com