Variable Speed Convertible Air Handler 5 Ton

Similar documents
Variable Speed Convertible Air Handler 2 1/2 Ton

Variable Speed Convertible Air Handler 4 Ton

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handler

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

36,000-62,000 BTUH Nominal Capacity

Cooling/Heat Pump Convertible Air Handlers

Vertical Upflow Horizontal Left Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Modular Multi-position Air Handlers

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Hyperion Field Reference Data TAM8

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Note: A/TZONE 950/850 communicating thermostats MUST be used for Variable Speed Outdoor units.

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Product Data. Split System Heat Pump D-EN. February 2016

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. Split System Heat Pump A-EN. March 2016

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Product Data. Split System Cooling A. November 2013

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

TECHNICAL SPECIFICATIONS B6VMMX

Bosch BVA Series Air Handler

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Multi-position Air Handler

Hyperion TM Split Systems

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

AIR HANDLERS AIR HANDLERS

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

4YCC3048A3096A /3/ /

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Split System Cooling Product & Performance Data

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

HIGH EFFICIENCY AIR HANDLER

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

HIGH EFFICIENCY AIR HANDLER

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /


AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Unit Features & Benefits RQPM/RQRM Series

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Product Data. Split System Heat Pump

Rheem High Efficiency Air Handler

Transcription:

Submittal Variable Speed Convertible Air Handler 5 Ton TEM6A0C60H51S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications. Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. February 2016 TEM6A0C60-SUB-1A-EN

Outline Drawing PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control TEM6A0C60H51SA 55.87 23.50 21.50 21.75 4.68 9.66 27.19 TXV 7/8 All dimensions are in inches Gas Line Braze 2 TEM6A0C60-SUB-1A-EN

Product Specifications MODEL TEM6A0C60H51SA Volts/Ph/Hz 208-230/1/60 RATED VOLTS/PH/HZ 208-230/1/60 F.L. Amps 6.8 RATINGS See O.D. Specifications FILTER INDOOR COIL Type Plate Fin Filter Furnished? (c) No Rows F.P.I. 3-16 Face Area (sq. ft.) 7.9 REFRIGERANT Ref. Line Connections R-410A Brazed Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.) (b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN Type Centrifugal Diameter-Width (In.) 11 X 10 No. Used 1 Drive - No. Speeds Direct - 16 vs. in. w.g. See Fan Performance Table No. Motors H.P. 1-3/4 Motor Speed R.P.M. Variable Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS 7/8 3/8 H x W x D Crated (In.) 57-1/8 x 27-1/2 x 25-1/2 Uncrated 55-3/4 x 23-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 185/174 These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4 Male Plastic Pipe (Ref: ASTM 1785 76) (c) Remote filter required. TEM6A0C60-SUB-1A-EN 3

Minimum Airflow TEM6A0C60H51S Heater Minimum Heater Airflow With Heat Pump Without Heat Pump BAYHTR1504BRKC, BAYHTR1504LUGB BAYHTR1505BRKC, BAYHTR1505LUGB 1200 975 BAYHTR1508BRKC, BAYHTR1508LUGB 1200 975 BAYHTR1510BRKC, BAYHTR1510LUGB 1200 975 BAYHTR1516BRKA 1200 975 BAYHTR3510LUGC 1200 975 BAYHTR3515LUGC 1200 975 BAYHTR1522BRKA 1350 1125 BAYHTR1525BRKA 1500 1350 TEM6A0C60H51 Airflow Performance with Auxiliary Heat Dip Switch Settings Airflow Settings Nominal Airflow Switch 7 Switch 8 Low ON ON 1000 Med-Lo OFF ON 1130 Med-Hi ON OFF 1354 See following tables for heater application: - Pressure Drop for Electrical Heters - Minimum Heating Airflow Matrix (on unit nameplates) High OFF OFF 1596 4 TEM6A0C60-SUB-1A-EN

Heater Pressure Drop Table Airflow Number of Racks Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1522 4 1100 0.01 0.03 0.05 0.09 BAYHTR1525 4 1000 0.01 0.03 0.04 0.09 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment for TEM6A0C48H41 & TEM6A0C60H51 Sub-Cooling Charge Specification For AHRI Rated Performance OD Equipment Up Flow / Horizontal Down Flow AC UNIT OD Name Plate OD Name Plate HP UNIT 3.5 Tons OD Name Plate OD Name Plate + 4 Degrees HP UNIT = 4 and 5 Tons OD Name Plate OD Name Plate TEM6A0C60-SUB-1A-EN 5

Performance and Electrical Data Table 1. (b) OUTDOOR UNIT SIZE (TONS) 3 3.5 4 5 Air Flow Performance TEM6A0C48, TEM6A0C60 COOLING AIRF PERFORMANCE, WET COIL, NO FILTER, NO HEATER SPEED SETTING (b) AIRF SETTING 324 / 368 / 423 / 314 / 357 / 411 / 298 / 339 / 389 / 305 / 347 / 399 / DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRF SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF Factory Default Setting Airflow must not exceed 1800 cfm in horizontal right, horizontal left, and downflow applications due to condensate blowoff. The 5 high tap shall not be used in these applications. Table 2. OUTDOOR UNIT SIZE (TONS) 3 3.5 4 Air Flow Performance SPEED SETTING 991 89 1120 118 1282 162 1116 117 1263 156 1449 218 1207 140 1368 190 1564 264 1534 251 1740 344 1995 484 985 133 1119 167 1286 219 1114 165 1266 212 1458 287 1208 193 1374 252 1577 343 1545 328 1758 444 2022 629 974 186 1110 224 1281 280 1105 222 1261 273 1456 352 1201 252 1370 315 1577 411 1545 394 1762 518 2030 717 TEM6A0C48, TEM6A0C60 HEATING AIRF PERFORMANCE, NO FILTER, NO HEATER AIRF SETTING 360 / 400 / 440 / 348 / 387 / 426 / 338 / 375 / 413 / 984 237 1116 279 1280 343 1111 277 1261 334 1449 421 1203 311 1367 381 1567 484 1536 467 1745 594 2005 783 994 303 1122 333 1282 402 1117 331 1263 392 1447 496 1207 366 1367 448 1561 570 1531 550 1734 684 1987 828 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRF SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF 1097 112 1215 142 1333 178 1232 147 1366 189 1500 238 1364 188 1509 241 1659 305 1094 160 1216 196 1338 238 1234 202 1373 252 1511 311 1370 251 1520 315 1674 395 1086 216 1210 255 1333 300 1228 261 1369 314 1510 377 1366 313 1519 382 1676 466 1092 271 1211 314 1331 365 1229 322 1366 381 1502 449 1363 379 1511 453 1662 541 1099 326 1215 369 1332 428 1233 377 1365 447 1498 529 1363 446 1506 535 1654 632 6 TEM6A0C60-SUB-1A-EN

Performance and Electrical Data Table 2. Air Flow Performance (continued) TEM6A0C48, TEM6A0C60 HEATING AIRF PERFORMANCE, NO FILTER, NO HEATER 5 326 / 362 / 398 / OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF 1637 295 1814 381 1990 481 1652 383 1834 493 2017 625 1653 453 1839 570 2025 713 1641 528 1820 645 2000 779 1632 618 1807 730 1982 826 Factory Default Setting 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 3. Electrical Data TEM6A0C48, TEM6A0C60 HEATER DATA Heater Model No. 240 Volt 208 Volt No. of Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kw BTUH Circuit Ampacity Protection kw BTUH Circuit Ampacity Protection No Heater 6.8 * 9 15 6.8 * 9 15 BAYHTR1504BRKC BAYHTR1504LUGB 1/1 3.84 13100 16.0 29 30 2.88 9800 13.8 26 30 BAYHTR1505BRKC BAYHTR1505LUGB 1/1 4.80 16400 20.0 34 35 3.60 12300 17.3 30 30 BAYHTR1508BRKC BAYHTR1508LUGB 1/1 7.68 26200 32.0 49 50 5.76 19700 27.7 43 45 BAYHTR1510BRKC BAYHTR1510LUGB 1/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1516BRKA Circuit 1 2/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1516BRKA Circuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR1522BRKA Circuit 1 2/1 9.60 32800 40.0 59 60 7.20 24600 34.6 52 60 BAYHTR1522BRKA Circuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYHTR1525BRKA Circuit 1 6.00 20500 25.0 40 40 4.50 15400 21.6 36 40 BAYHTR1525BRKA Circuit 2 4/1 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR1525BRKA Circuit 3 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR1525BRKA Circuit 4 6.00 20500 25.0 31 35 4.50 15400 21.6 27 30 BAYHTR3510LUGC 1/3 9.60 32800 23.1 36 40 7.20 24600 20.0 33 35 BAYHTR3515LUGC 1/3 14.40 49100 34.6 51 60 10.80 36900 30.0 45 45 * = Motor Amps MCA and MOP for circuit 1 contains the motor amps TEM6A0C60-SUB-1A-EN 7

Features and Benefits Painted metal cabinet with captured foil face insulation 2% or less air leakage R-4.2 Insulating Value Multi-Position UP/Down Flow, Horizontal Left /Right ALL Aluminum Coil with Enhanced Patented Coil Fin Electric Heaters with polarized plug connections (sold as accessory) R-410A Thermal Expansion Valve Variable Speed ECM Motor Low Voltage Pigtail Connections Draw Through Design Horizontal Drain Pan Single Color Fused 24V Power 1 year warranty 10-year warranty registered Optional extended warranty available The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.irco.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 2016 Trane TEM6A0C60-SUB-1A-EN 03 Feb 2016 Supersedes (New)