Submittal. Date: March 20, Customer P.O. Number: Customer Project Number: Job Number: Job Name: General Dynamics

Similar documents
Roof Top Packaged Unit (RTU-1) Specification

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Roof Top Units - RTU-1/2/3/4

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Modular Multi-position Air Handler

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product & Performance Data

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Split System Cooling Product Data

PAJ3. Product Specifications

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

PAR5. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Split System Heat Pump Product Data

4YCC3048A3096A /3/ /

RGE 13 A T - 1 A

Split System Cooling Product Data

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Modular Multi-position Air Handlers

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Advance Release September 2009

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Commercial High-Efficiency Condensing Units

Hyperion TM Split Systems

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

13 GEP A L P - 1 A

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Split System Cooling Product Data

Cooling/Heat Pump Convertible Air Handlers

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

48TM GAS HEATING/ELECTRIC COOLING UNITS

Split System Heat Pump Product Data

Split System Heat Pump Product Data

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

MAC N-407 Air-Cooled Chiller

Split System Cooling Product Data

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data. Split System Cooling A. November 2013

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Split System Heat Pump Product & Performance Data

Variable Speed Convertible Air Handler 5 Ton

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Catalog. Packaged Rooftop Air Conditioners Foundation Cooling and Gas/Electric 3 to 5 Tons, 60Hz RT-PRC078C-EN.

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Cooling/Heat Pump Convertible Air Handlers

AMERICAN STANDARD 14 MODELS 4A7B E

Vertical Upflow Horizontal Left Air Handlers

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Cooling/Heat Pump Convertible Air Handlers

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGE AIR CONDITIONER

36,000-62,000 BTUH Nominal Capacity

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Split System Cooling Product & Performance Data

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

C13-Series Engineering Guide

Variable Speed Convertible Air Handler 4 Ton

Split System Cooling Product Data

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Transcription:

Submittal Prepared For: Wade Stewart Edmonds Engineering Sold To: Shook & Fletcher Mechanical Date: March 20, 2017 Customer P.O. Number: Customer Project Number: Job Number: Job Name: General Dynamics Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Split System Air Conditioning Units (Small) 1 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Lance Lee Trane 1030 London Drive, Suite 100 Birmingham, AL 35211 Phone: (205) 747-4000 Cell: Fax: (205) 747-4005 Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer s responsibility to obtain such verification. -Coordinate gas input of AC-HOT w/ Plumbing contractor. Input is larger than scheduled. J:\JOBS\50\102064\4\General DynamicsRe-SUB.doc

Table Of Contents Product Summary...1 Split System Air Conditioning Units (Small) (Item A1) Tag Data... 3 Product Data... 3 Performance Data... 3 Mechanical Specifications... 4 Unit Dimensions... 6 Weight, Clearance & Rigging Diagram... 10 Accessory... 11 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Item B1) Tag Data... 13 Product Data... 13 Performance Data... 13 Mechanical Specifications... 16 Unit Dimensions... 18 Weight, Clearance & Rigging Diagram... 21 Accessory... 23 Field Installed Options - Part/Order Number Summary Split System Air Conditioning Units (Small)... 24

Tag Data - Split System Air Conditioning Units (Small) (Qty: 1) Item Tag(s) Qty Description Model Number A1 AC-Cold 1 Split System 4TTA3036B4-----------GAM5B0C42M1E--------0------0000----- 0----0-00000-0----000-0--0 Product Data - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold Split System Cooling Outdoor Unit 3 Ton Nominal Cooling Capacity 460 Volt 3 Phase 60 Hertz Multi-poise 4-way Footprint - C 3.5 Ton air handler Mid EFF Multi-speed 208-230/1/60 Black Epoxy Coil Electronic, 3 Htg/2Clg Non Programmable (Fld) Head pressure control (Fld) Anti-short cycle timer (Fld) Performance Data - Split System Air Conditioning Units (Small) Tags AC-Cold Design clg outdoor DB (F) 95.00 Cooling EDB (F) 80.00 Cooling EWB (F) 67.00 Rated gross capacity (AHRI) (Btuh) 37000.00 Clg net total capacity (Btuh) 37100.00 Clg net sensible capacity (Btuh) 27700.00 Clg net latent capacity (Btuh) 9400.00 Calc clg LDB (F) 58.30 Calc clg LWB (F) 56.80 SEER @ AHRI (btuh/watt) 14.50 EER @ AHRI (EER) 12.0 Cooling airflow (cfm) 1200 Min system airflow clg (cfm) 1050 Max system airflow clg (cfm) 1350 AHRI airflow (cfm) 1175 AHRI reference number ( ) 5863271 Compressor power @ (specific Ambient) (W) 2575.0 Condenser fan power @ (specific SP) (W) 150.0 Supply fan power @ (specified SP) (W) 358.0 ASHRAE 90.1 S6.4.1 compliant Yes Blower capability 3.0 ton to 3.5 ton airflow 80 to 90 second blower off delay Not Required OD AHRI Model (Each) -1.00 Equipment Submittal Page 3 of 24

Mechanical Specifications - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold 4TTA3 - General This unit is fully charged from the factory for matched indoor section and up to 180" of piping. Unit is designed to operate at outdoor ambient temperatures as high as 115.0 F]. Cooling capacities matched with a wide selection of air handlers and furnace coils that are A.R.I certified. The unit shall be UL listed. Exterior must be designed for outdoor application. 4TTA3 - Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Corrosion and weatherproof CMBP-G30 Duratuff base. 4TTA3 - Compressor The Climatuff compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: centrifugal oil pump, and low vibration and noise. 4TTA3 - Condenser Coil The Spine Fin coil is continuously wrapped, corrosion resistant, all aluminum with minimum brazed joints. The coil is 3/8" O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2000.0 lb of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. 4TTA3 - Refrigerant controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure protection is inherent to the compressor. Another standard feature is the factory installed liquid line drier. GAM5 Air-Tite II cabinet 2% or less air leakage Precision applied - durable door seals Specially designed air seal around refrigerant, condensate and conduit connections Double wall foamed cabinet system R-4.2 insulating value No loose fiber design Smooth cleanable interior design Sweat eliminating design Composite foamed cabinet doors Water proof cabinet design Integrated horizontal drain pans Modular cabinet with " allen wrench "quick latch" design Multi-position up/down flow horizontal left/right Side return option Control board protection pocket built into cabinet wall Alert port to view control board codes without door removal 10 alert codes Low voltage terminal connection point Quarter turn phillips head door fasteners Vortica blower with polarized plug connections and integrated slide deck for easy removal Patented enhanced coil fin Dual refrigerant compatible as shipped Slide in electric heaters with polarized plug connections (sold as accessory) UVC light kit with safety switch and polarized plug connections (sold as accessory) Labeled panels and connections Molded in 1" standard filter rail High efficiency ECM motor Soft start fan motor operation Built in fan delay modes Maximum width of 23 1/2" Compact 20 13/16" depth with doors removed Two tone color Fused 24v power Safety door switch Equipment Submittal Page 4 of 24

1-year warranty 10-year warranty registered Optional extended warranty available Head Pressure Control Accessory The Head Pressure Control (BAYLOAM***) accessory is a low voltage (24 Volts ) electronic head pressure control that cycles the condenser fan motor based on liquid temperature. The addition of this field installed Head Pressure Control accessory permits cooling operation to 0 deg F [-17.8 deg C] providing that non-bleed TXV's, quick start components, and compressor crankcase heat are provided with the system when required. 5 Minute Delay Relay Kit This delay relay kit will prevent rapid on-off compressor cycling in light load conditions by not allowing compressor to operate for 5 minutes upon shutdown. Head Pressure Control Controls fan motor (on/off) in response to outdoor ambient temperature in conjunction with liquid line temperature. Accessory provides unit cooling operation to outdoor temperatures of 0F Equipment Submittal Page 5 of 24

Unit Dimensions - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold 1 1/2" 21 3/4" 14 3/8" 5 15/16" NOTES: 1. BADGE ROTATION WILL KEEP BRAND IN CORRECT POSITION. 2. NO INTERNAL MODIFICATIONS REQUIRED FOR ANY POSITION. 3. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 4. GAM5 AIR HANDLERS ARE ALL TWO PIECE CABINETS. 5. SEE WEIGHT AND RIGGING PAGE FOR CONDENSATE DRAIN CONFIGURATION 23 1/2" 20 1/2" 1 1/2" 10 5/16" 3" 3/8" LIQUID LINE 7/8" GAS LINE CONDENSATE DRAIN SEE NOTE 1 56 7/8" 1 1/2" 46 11/16" 21 13/16" 24 1/2" 17 1/8" 1 1/2" 1 1/2" 3 3/16" 20 1/2" GAM5A0A42 AIR HANDLER UNIT DIMENSION DRAWING 1 1/2" Equipment Submittal Page 6 of 24

Unit Dimensions - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold ELECTRICAL / GENERAL DATA GENERAL (1)(2)(4) Model: Unit Primary Voltage: Unit Secondary Voltage: Unit Hertz: Unit Phase: GAM5A0C42M31SA 208 230 60 1 INDOOR MOTOR Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: (1) (3) FILTERS 1 0.5 1050 1 4.1 Type: Furnished: Number: Recommended: Throwaway No 1 22"x20"x1" (5) STANDARD 230 Volt / 208 Volt Minimum Circuit Ampacity: Maximum Overload Protection: 5.0/5.0 15.0/15.0 REFRIGERANT Type: REF. Line Connections Coupling or Conn. Size - Gas: Coupling or Conn. Size - Liq.: R410 Brazed 7/8" 3/8" Weights Net: Shipping: 153.0 lb 163.0 lb ELECTRIC HEAT 230 Volt / 208 Volt Capacity Circuit #1: Capacity Circuit #2: Capacity Circuit #3: # of Circuit: Phase: Heater Amps Per Circuit Circuit #1: Heater Amps Per Circuit Circuit #2: Heater Amps Per Circuit Circuit #3: Minimum Circuit Ampacity Circuit #1: Minimum Circuit Ampacity Circuit #2: Minimum Circuit Ampacity Circuit #3: Maximum Overload Protection Circuit #1: Maximum Overload Protection Circuit #2: Maximum Overload Protection Circuit #3: NOTES: 1. These air handlers are a.r.i. certified with various split system air conditioners and heat pumps (ari standard 210/240). refer tothesplit system outdoor unit product data guides for performance data. 2. 3/4" male plastic pipe (ref.: astm 1785-76) 3. Minimum filter size for horizontal applications will be based on airflow selection and will be calculated as follows: low velocity filter: face area (sq. ft.) = cfm / 300 high velocity filter: face area (sq. ft.) = cfm / 500 4. For customer ease of filter maintenance, it is recommended that a properly sized, remote filter and grille be installed for horizontal applications. airflow should not exceed the face value of the filter being used 5. Standard mca and mop without electric heat. Equipment Submittal Page 7 of 24

Unit Dimensions - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold 32 5/8" UNIT DIMENSTIONS DIM - D 3/4" DIM - E 5/16" SERVICE PANEL SEE NOTE 2 29 3/4" NOTES 1. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 12" FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 2. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. 1" ELECTRICAL SERVICE PANEL 7/8" DIA. HOLE LOW VOLTAGE 20" 1 1/8" DIA. K.O. WITH 7/8" DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY 1" 36 3/4" LIQUID LINE SERVICE VALVE, "E" I.D. FEMALE BRAZE CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. 8 1/4" 5 5/8" 8 1/4" 5 5/8" LIQUID LINE SERVICE VALVE, "E" I.D. FEMALE BRAZE CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. 3 1/8" 3 5/8" GAS LINE 1/4" TURN BALL SERVICE VALVE, "D" I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. 3 1/8" 3 5/8" GAS LINE SERVICE VALVE, "D" I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. Equipment Submittal Page 8 of 24

Unit Dimensions - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold ELECTRICAL / GENERAL DATA GENERAL Model: Operating Voltage: Unit Primary Voltage: Unit Secondary Voltage Unit Hertz: Unit Phase: POWER CONN. 4TTA3036* Minimum Circuit Ampacity: 7.0 414-506 460-60 3 Maximum Circuit Breaker: Minimum Protection Rating: 15.0 15.0 COMPRESSOR Number: Phase: Rated Load Amps: Locked Rotor Amps: 1 3 5.1 35.0 OUTDOOR MOTOR Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: 1 0.125 825 3 0.4 - NOTES: 1. Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240. 2. Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses. 3. Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0 4. * = 15, 20, 25, 30, 40 and 50 foot lineset available. REFRIGERANT Type: Charge: Line Size O.D. Gas: Line Size O.D. LIQ: R-410 6.4 lb 3/4" 3/8" NET SHIPPING WEIGHT 201.0 lb 229.0 lb NOTES: C1. TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT C2. PLACE UNIT FROM WALL C3. PLACE SHRUBBERY AT LEAST 12" FROM UNIT ON TWO SIDES, OTHER SIDES UNRESTRICTED C4. PLACE UNIT SO ROOF RUN-OFF DOES NOT FALL DIRECTLY ON UNIT C1 DISCHARGE C4 C3 C2 C3 WEIGHT AND CLEARANCE Equipment Submittal Page 9 of 24

Weight, Clearance & Rigging Diagram - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold VERTICAL DOWNFLOW REFRIGERANT CONNECTION DOWNFLOW CONDENSATE DRAIN REFRIGERANT CONNECTION DOWNFLOW CONDENSATE DRAIN REFRIGERANT CONNECTION VERTICAL UPFLOW HORIZONTAL LEFT FLOW REFRIGERANT CONNECTION DOWNFLOW CONDENSATE DRAIN HORIZONTAL RIGHT FLOW DOWNFLOW CONDENSATE DRAIN NOTES 1. NO INTERNAL MODIFICATIONS REQUIRED FOR ANY POSITION. 2. BADGE ROTATION WILL BRAND IN CORRECT POSITION. SIDE FRONT BACK INLET DUCT OUTLET DUCT MINIMUM UNIT CLEARANCE TABLE TO COMBUSTIBLE MATERIALS (REQUIRED) 0 0 0 0 0 SERVICE CLEARANCE (RECOMMENDED) 2" 21" 0 0 0 CLEARANCE NOTES: * 1" FOR THE FIRST 3 FT. OF OUTLET DUCT WHEN ELECTRIC HEATERS ARE INSTALED EXCEPT MODELS BAYHTR1405, 1408, AND 1410 ARE APPROVED FOR 0" PLEMUM AND DUCT CLEARANCE IN THE UPFLOW CONFIGURATION ONLY ON TWE-P MODELS. Equipment Submittal Page 10 of 24

Accessory - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold NOTES: 1. * FOR MULTIPLE STAGES OF ELECTRIC HEAT, JUMPER W1, W2, AND W3 TOGETHER IF COMFORT CONTROL HAS ONLY ONE STAGE OF HEAT. 2. ** R TO O JUMPER MUST BE IN PLACE AS SHOWN FOR COOLING ONLY, NON-HEAT PUMP SYSTEMS FOR PROPER OPERATION. 3. YI AND YO CONNECTIONS MUST BE MADE AS SHOWN FOR FREEZE PROTECTION AND INTERNALLY MOUNTED CONDENSATE OVER FLOW CIRCUITS TO WORK PROPERLY. 4. INTERNALLY MOUNTED CONDENSATE SWITCH IS OPTIONAL AND MUST BE ORDERED SEPARATELY. 5. IF 3RD PARTY CONDENSATE OVERFLOW SWITCHES ARE INSTALLED, THEY SHOULD BE WIRED IN SERIES BETWEEN YO AND Y TO THE OUTDOOR UNIT. 6. MAKE CONNECTIONS PER HOOKUP DIAGRAMS. 7. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES 8. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. AIR CONDITIONER COMFORT CONTROL AIR HANDLER BLUE WHITE GREEN YELLOW ORANGE RED BLUE W G Y O R B WHITE GREEN YELLOW RED BLUE W 3 W 2 W 1 G YI O R B YO B - BLUE Y - YELLOW YELLOW AIR HANDLER HOOK-UP - COOLING FIELD WIRING DIAGRAM Equipment Submittal Page 11 of 24

Accessory - Split System Air Conditioning Units (Small) Item: A1 Qty: 1 Tag(s): AC-Cold 6 3/4" 1 3/16" 4 1/2" 5 15/16" 5 7/16" 5 1/16" 4 3/4" 3 5/16" 11/16" 9/16" 15/16" 1 13/16" 2 1/16" 3 5/16" TCONT401 AND 402 ACCESSORY - THERMOSTAT Equipment Submittal Page 12 of 24

Tag Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Qty: 1) Item Tag(s) Qty Description Model Number B1 OSA-HOT 1 100% Outside Air Unit YHC092F4ELA--00B00000000 Product Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT DX cooling, gas heat High efficiency Convertible configuration 7.5 Ton Dual compressor 460/60/3 Electro mechanical controls 3ph Low gas heat 3ph Standard panel/2 in pleated filters Merv 8 Morganizer 100% OA Modification Model Number: OHC092E Entering Air Conditions to DX Coil CFM: 1200.00 EDB: 96.00 EWB: 74.00 CDB: 95.00 ALT:.00 TSP: Circuit 1 Circuit 2 Saturated Temperature Entering Compressor (1): 49.84 48.47 Super Heat (2): 17.21 18.30 Suction Pressure: 142.24 138.72 Discharge Pressure: 371.44 366.46 Fan RPM: FAN HP:.628 Leaving Air Conditions from DX Coil LDB: 52.74 LWB: 51.67 Gross Total Capacity: 85.07 Gross Sensible Capacity: 55.19 Gross Latent Capacity: 29.89 Net Total Capacity: 83.48 Net Sensible Capacity: 53.59 Net Latent Capacity: 29.89 (1) Valid selection is between 40 and 58 deg. F. (2) Valid selection for Voyager Commercial and Ipak is between 8-35 deg. F. Not relevant for light commercial Voyagers.) This information is only valid for Morganizer Selections. Performance Data - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Tags OSA-HOT Input Heating Capacity (MBh) 120.00 Output Heating Capacity (MBh) 96.00 Output Heating Cap. w/fan (MBh) 100.79 Design ESP (in H2O) 0.900 Component SP (in H2O) 0.123 Field supplied drive kit required None Equipment Submittal Page 13 of 24

Tags OSA-HOT Indoor mtr operating power (bhp) 1.73 Indoor RPM (rpm) 1344 Indoor Motor Power (kw) 1.29 Outdoor Motor Power (kw) 0.71 Compressor Power (kw) 6.08 System Power (kw) 8.08 IPLV @ AHRI (IPLV) 14.5 MCA (A) 19.90 MOP (A) 25.00 Compressor 1 RLA (A) 7.10 Compressor 2 RLA (A) 4.70 Evaporator fan FLA (A) 4.30 Condenser fan FLA (A) 2.80 Evaporator face area (sq ft) 12.36 Evaporator rows (Each) 4.00 Evaporator fin spacing (Per Foot) 192 Evaporator face velocity (ft/min) 283 Min. unit operating weight (lb) 1026.0 Max. unit operating weight (lb) 1291.0 Fan motor heat (MBh) 4.79 Dew Point (F) 56.76 Ducted Discharge Heating - 63 Hz (db) 80 Ducted Discharge Heating - 125 Hz (db) 89 Ducted Discharge Heating - 250 Hz (db) 83 Ducted Discharge Heating - 500 Hz (db) 80 Ducted Discharge Heating - 1 khz (db) 76 Ducted Discharge Heating - 2 khz (db) 71 Ducted Discharge Heating - 4 khz (db) 71 Ducted Discharge Heating - 8 khz (db) 63 Ducted Inlet Heating - 63 Hz (db) 80 Ducted Inlet Heating - 125 Hz (db) 81 Ducted Inlet Heating - 250 Hz (db) 78 Ducted Inlet Heating - 500 Hz (db) 69 Ducted Inlet Heating - 1 khz (db) 58 Ducted Inlet Heating - 2 khz (db) 59 Ducted Inlet Heating - 4 khz (db) 60 Ducted Inlet Heating - 8 khz (db) 50 Outdoor Noise Heating - 63 Hz (db) 90 Outdoor Noise Heating - 125 Hz (db) 86 Outdoor Noise Heating - 250 Hz (db) 90 Outdoor Noise Heating - 500 Hz (db) 85 Outdoor Noise Heating - 1 khz (db) 80 Outdoor Noise Heating - 2 khz (db) 77 Outdoor Noise Heating - 4 khz (db) 74 Outdoor Noise Heating - 8 khz (db) 66 Rated capacity (AHRI) (MBh) 89.00 Exhaust fan power (kw) 0.65 Refrig charge (HFC-410A) - ckt 1 (lb) 5.5 Refrig charge (HFC-410A) - ckt 2 (lb) 4.2 ASHRAE 90.1 Yes Saturated Suction Temp Circuit 1 (F) 54.13 Saturated Discharge Temp Circuit 1 (F) 116.87 Saturated Suction Temp Circuit 2 (F) 55.93 Saturated Discharge Temp Circuit 2 (F) 113.74 IEER ( ) 14.50 EER @ AHRI Conditions (EER) 12.6 Equipment Submittal Page 14 of 24

Tags OSA-HOT Total Static Pressure (in H2O) 1.023 Equipment Submittal Page 15 of 24

Mechanical Specifications - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT General The units shall be convertible airflow. The operating range shall be between 115 F and 0 F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115 F and 40 F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be culus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Two-Inch Pleated Filters 2" pleated media filters shall be available on all models. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7½-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on YSC (036, 048, 060, 072, 090, 102, 120); standard on YHC (036, 048, 060, 072, 092, 102, 120). Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8½ ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7½ to 8½ (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard Equipment Submittal Page 16 of 24

for all 3 to 10 ton standard efficiency models and 4,5,6, 7.5, 8.5 ton high efficiency models.the microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight.these all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity.the evaporator coil and condenser coil shall be leak tested to 600 psig.the assembled unit shall be leak tested to 465 psig.the condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning.a plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Plenum Fan The following unit shall be equipped with a direct drive plenum fan design (all 10 tons and 7.5-8.5 ton high efficiency units). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. Equipment Submittal Page 17 of 24

Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE CONDENSER COIL 4 1/4" 27 5/8" 47 7/8" UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE 1/2" NPT GAS CONNECTION (80MBH & 120MBH) 3/4" NPT GAS CONNECTION (150MBH, 200MBH & 250MBH) THROUGH THE BASE CONDENSATE 4 1/8" CONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS / ELECTRICAL ISOMETRIC VIEW 27 5/8" NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. 33" SUPPLY 32 1/8" RETURN 4" 17 1/2" 9 7/8" 17 1/2" 3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 23 7/8" SUPPLY RETURN 32 1/4" 46 7/8" HORIZONTAL AIR FLOW 24 1/2" 4 3/4" 9 5/8" 5 5/8" CONDENSATE 19 1/4" 88 5/8" 9 3/8" 16 3/4" 3 7/8" PACKAGED GAS / ELECTRICAL 4 1/4" 5 5/8" 7 5/8" 53 1/4" DIMENSION DRAWING Equipment Submittal Page 18 of 24

Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT SUPPLY RETURN 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3/4" ISOMETRIC-PACKAGED COOLING Equipment Submittal Page 19 of 24

Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT ELECTRICAL / GENERAL DATA (2)(4)(6) GENERAL Model: Unit Operating Voltage: Unit Primary Voltage: Unit Secondary Voltage Unit Hertz: Unit Phase: EER Standard Motor MCA: MFS: MCB: YHC092F 414-506 460 -- 60 3 20.7 25.0 25.0 Oversized Motor MCA: MFS: MCB: Field Installed Oversized Motor MCA: MFS: MCB: HEATING PERFORMANCE HEATING - GENERAL DATA Heating Model: Heating Input (BTU): Heating Output (BTU): No. Burners: No. Stages Gas Inlet Pressure Natural Gas (Min/Max): LP (Min/Max) Gas Pipe Connection Size: Low 120,000 96,000 3 1 4.5/14 11.0/14.0 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: Horsepower: Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: 1 3.6 -- 3 4.3 -- Number: Horsepower: Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: Number: Horsepower: Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: COMPRESSOR Circuit 1/2 Number: Horsepower: Phase: Rated Load Amps: Locked Rotor Amps: 2 4.1/2.4 3 7.1/4.7 52.0/38.0 OUTDOOR MOTOR Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: 1 0.75 1100 1 2.8 6.2 POWER EXHAUST ACCESSORY (Field Installed Power Exhaust) Phase: Horsepower: Motor Speed (RPM): Full Load Amps: Locked Rotor Amps: (3) FILTERS Type: Furnished: Number Recommended Throwaway Yes 4 20"x25"x2" (2) REFRIGERANT Type Factory Charge Circuit #1 Circuit #2 R-410 5.5 lb 4.2 lb NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. Equipment Submittal Page 20 of 24

Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS C B D A ECONOMIZER MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAL/GAS (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN PACKAGED GAS / ELECTRICAL CORNER WEIGHT NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET A 340.0 lb C 249.0 lb (E) LENGHT (F) WIDTH 1124.0 lb 1026.0 lb B 233.0 lb 204.0 lb 41" 23" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at +/- 10 % of the nameplate weight.. 6. Verify weight, connection, and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. D E F PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY Equipment Submittal Page 21 of 24

Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT CLEARANCE 36" CLEARANCE 48" CLEARANCE FROM TOP OF UNIT 72" SUPPLY RETURN DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE ROOF OPENING UNIT OUTLINE 46" 53 1/4" 46" 88 5/8" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING Equipment Submittal Page 22 of 24

Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: B1 Qty: 1 Tag(s): OSA-HOT ECONOMIZER HOOD ECONOMIZER HOOD 6 7/8" 16 3/4" ACCESSORY - ECONOMIZER HOOD Equipment Submittal Page 23 of 24

Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Split System Air Conditioning Units (Small) Item Tag(s) Qty Description Model Number A1 AC-Cold 1 Split System 4TTA3036B4-------- ---GAM5B0C42M1 E--------0------0000- ----0----0-00000-0-- --000-0--0 Field Installed Option Description Electronic, 3 Htg/2Clg Non Programmable Head pressure control Anti-short cycle timer Part/Ordering Number TCONT402AN32DA BAYLOAM103 TAYASCT501A Equipment Submittal Page 24 of 24