Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Similar documents
Hyperion TM Split Systems

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product & Performance Data

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Modular Multi-position Air Handler

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling E-EN. November 2016

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Cooling Product Data

Illusion Split System

Appendix J Noise Appendix

Split System Cooling Product Data

Split System Heat Pump Product Data

Product Data Split System Cooling

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Cooling Product Data

Split System Cooling Product & Performance Data

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Modular Multi-position Air Handlers

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

36,000-62,000 BTUH Nominal Capacity

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Cooling/Heat Pump Convertible Air Handlers

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Cooling/Heat Pump Convertible Air Handlers

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Cooling/Heat Pump Convertible Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Variable Speed Convertible Air Handler 5 Ton

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Variable Speed Convertible Air Handler 2 1/2 Ton

Variable Speed Convertible Air Handler 4 Ton

Vertical Upflow Horizontal Left Air Handlers

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Split System Cooling Product Data XB 1000

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Product Data. Convertible Air Handlers 1 1/2 5Ton

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Split System Heat Pump Product Data

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Commercial High-Efficiency Condensing Units

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Multi-position Air Handler

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

R4H4. Product Specifications

PAJ3. Product Specifications

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

WCH5**4. Product Specifications

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Transcription:

Product catalog Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Features and Benefits Outdoor unit 4TTB Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy service access and refrigerant connections with full coil protection Fast complete drain, weather proof base Comfort "R" mode approved Glossy corrosion resistant finish Internal high/low pressure and temperature protection 018, 024, 030 ship with start kit Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge & cap High pressure switch R-410A refrigerant S.E.E.T. design testing 100% line run test Low ambient cooling to 55 F as shipped Low ambient cooling to 30 F with AY28X079 Low ambient cooling to 0 F with BAYLOAM103 Extended warranties available Outdoor unit 4TTA3 Climatuff compressor All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant connections with full coil protection DuraTuff base, fast complete drain, weatherproof Comfort R mode approved Glossy corrosion resistant finish Internal compressor high/low pressure and temperature protection Liquid line filter-drier Polyslate gray cabinet with anthracite gray badge and cap R-410A refrigerant Low Pressure Switch High Pressure Switch Compressor Sump Heat S.E.E.T. design testing 100% line run test Low ambient cooling to 55 F as shipped Low ambient cooling to 30 F with AY28X079 Low ambient cooling to 0 F with BAYLOAM103 Indoor convertible air handler GAF Unique Cabinet Design - Double Wall Foamed and Formed Cabinet System - Water Proof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage - Precision Applied Durable Door Seals Multi-Position Upflow/ Horizontal Left / Horizontal Right Front Return Option Braze in Refrigerant Connection Primary/Secondary Condensate Connections Vortica Blower with Integrated Slide Deck for Easy Removal Polarized Plug connections on Blower Aluminum Coil with Integrated Slide Deck for Easy Removal Slide in Electric Heaters Polarized Plug connections for Electric Heater Labeled Panels and connections Guide for 1-1/4" to 1" And 3/4" to 1/2" Conduit connection on Top R-410A Thermal Expansion Valve (TXV) Low Voltage Color Coded Wires Enhanced Coil Fin Patented Blow Through Design PSC 3 Speed Motor Maximum Width of 17.5" Compact 20.8" depth with doors removed Integrated Horizontal Drain pans Single Color Fused 24V Power Optional extended warranty available Indoor convertible air handler GAT Unique Cabinet Design - Double Wall Foamed and Formed Cabinet System - Water Proof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8.2) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage - Precision Applied Durable Door Seals - Tool-free Fasteners on Blower/Filter Door - Modular Cabinet Multi-Position Upflow/ Horizontal Left / Horizontal Right Braze in Refrigerant Connection Primary/Secondary Condensate Connections Premarked Conduit Connection Locations Vortica Blower with Integrated Slide Deck for Easy Removal Polarized Plug connections on Blower Control Protection Pocket Aluminum Coil with Integrated Slide Deck for Easy Removal Slide in Electric Heaters Polarized Plug connections for Electric Heater Labeled Panels and connections 1-1/4" to 1" And 3/4" to 1/2" Conduit connection on Left, Right and Top Molded in 1" Standard Filter rail R-410A Thermal Expansion Valve (TXV) Low Voltage Terminal Connection Point Enhanced Coil Fin Patented Blow Through Design PSC 3 Speed Motor on 3.5 & 4 ton models Constant torque ECM Motor on 5 ton model Maximum Width of 23.5" Compact 20.8" depth with doors removed Integrated Horizontal Drain pans Single Color Fused 24V Power Safety Door Switch 5 year warranty 2013 Trane 2 SSA-PRC009-E4

Contents Features and Benefits 2 Nomenclature 4 Unique Cabinet Design Features and Benefits GAF 5 Unique Cabinet Design Features and Benefits GAT 6 General Data 4TTB 7 General Data 4TTA 9 General Data GAF 12 Airflow Data GAF 13 General Data GAT 20 Airflow Data GAT 21 Performance Data 26 Electrical Data GAF 71 Electrical Data GAT 73 Wiring 4TTB 76 Wiring 4TTA 80 Field wiring GAF 85 Field wiring GAT 89 Convertibility GAF / GAT 91 Dimensions 4TTB 92 Dimensions GAF 93 Dimensions GAT 95 Mechanical Specifications Outdoor Units 97 SSA-PRC009-E4 3

Nomenclature Outdoor Units 4 T T A 3 0 3 6 A 3 0 0 0 A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 4 SSA-PRC009-E4

Unique Cabinet Design Features and Benefits GAF 2 Precision Durable Door Seals 1 Unique Cabinet Design 5 Conduit Connection Location r Integrated Horizontal Drain Pans 9 All Aluminum Coil q Thermal Expansion Valve (TXV) 3 Refrigeration Connections 4 Condensate Connections 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck 0 Labeled Panels and Connections w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage 2 Precision Durable Door Seals 3 Brazed Refrigeration Connections 4 Primary/Secondary Condensate Connections 5 Conduit Connection - Conduit Connection on Top 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck - Polarized Plug on Blower 9 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil TXV - Patented Enhanced Coil Fin 0 Labeled Panels and Connections q R-410A Thermal Expansion Valve (TXV) w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed r Integrated Horizontal Drain Pans SSA-PRC009-E4 5

Unique Cabinet Design Features and Benefits GAT 1 Unique Cabinet Design 5 Conduit Connections e Integrated Horizontal Drain Pans 2 Precision Durable Door Seals 0 Thermal Expansion Valve (TXV) 3 Refrigeration Connections 8 All Aluminum Coil 4 Condensate Connections r Safety Door Switch 7 Vortica TM Blower and Deck 6 Tool-less Door Fasteners 9 Labeled Panels and Connections w Compact 20.8 Depth with Doors Removed 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design - R-4.2 Insulating Value (Avg Insulating Value R-8.2) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design 2 Precision Durable Door Seals 3 Refrigeration Connections 4 Condensate Connections 5 Premarked Conduit Connection Locations - Conduit Connections on Left, Right, and Top 6 Tool-less Door Fasteners 7 Vortica TM Blower and Deck - Polarized Plug on Blower q Maximum width is 23.5 8 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil EEV - Patented Enhanced Coil Fin 9 Labeled Panels and Connections 0 R-410A Thermal Expansion Valve (TXV) q Maximum width is 23.5 w Compact 20.8 Depth with Doors Removed e Integrated Horizontal Drain Pans r Safety Door Switch - Fused 24V Power t Modular Cabinet 6 SSA-PRC009-E4

General Data 4TTB Product Specifications Model No. 1 4TTB3018E1 4TTB3018G1 4TTB3024E1 4TTB3024G1 4TTB3030E1 4TTB3030G1 4TTB3036E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 200/230/1/60 200/230/1/60 208/230/1/60 Min Branch Cir Ampacity 9 12 12 17 15 19 20 Br. Cir. Prot. Rtg. - Max (Amps) 15 20 20 25 25 30 35 Compressor SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL RL Amps - LR Amps 6.4-40 9-48 8.9-48.5 12.8-58.3 11.5-63.5 11.5-63.5 15.3-70 Outdoor Fan FL Amps 0.74 0.74 0.74 0.74 0.74 0.74 0.74 Fan HP 1/8 1/8 1/8 1/8 1/8 1/8 1/8 Fan Dia (inches) 23.0 23.0 23.0 23.0 23.0 23.0 23.0 Coil Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 4/15-LB/OZ 5/11-LB/OZ 5/8-LB/OZ 5/9-LB/OZ 5/2-LB/OZ 5/11-LB/OZ 5/12-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 5/8 5/8 5/8 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 8 10 10 10 10 10 10 Dimensions H x W x D (Crated) 34 x 30.1 x 33 34 x 30.1 x 33 34 x 30.1 x 33 34 x 30.1 x 33 34 x 30.1 x 33 34 x 30.1 x 33 34 x 30.1 x 33 Weight - Shipping 191 167 196 169 200 180 186 Weight - Net 165 140 169 142 173 153 159 Start Components YES NO YES NO YES NO NO Sound Enclosure YES NO YES NO NO NO NO Compressor Sump Heat NO NO NO NO NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT300 BAYCCHT301 BAYCCHT300 BAYCCHT301 BAYCCHT300 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN950 TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL db [(db(a)] 63 125 250 500 1000 2000 4000 5000 4TTB3018E1 78 45.5 59.6 62.2 69.3 71.1 70.9 62.2 54.3 4TTB3024E1 78 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5 4TTB3030E1 78 49.0 60.2 66.0 70.3 71.4 69.8 60.4 53.0 4TTB3018G1 76 45.5 59.6 62.2 69.3 71.1 70.9 62.2 54.3 4TTB3024G1 76 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5 4TTB3030G1 76 49.0 60.2 66.0 70.3 71.4 69.8 60.4 53.0 4TTB3036E1 74 47.5 64.5 62.3 69.1 71.2 72.6 59.9 52.1 4TTB3042D1 79 47.5 64.5 67.0 75.3 74.0 70.7 62.2 52.8 4TTB3048D1 79 47.4 60.0 66.9 75.3 73.5 70.3 62.0 51.4 4TTB3060D1 80 47.3 55.7 69.0 72.7 75.8 69.4 62.2 53.3 Note: Rated in accordance with AHRI Standard 270-2008 SSA-PRC009-E4 7

General Data 4TTB Product Specifications Model No. 1 4TTB3042D1 4TTB3048D1 4TTB3060D1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 26 28 35 Max Fuse Size (Amps) 45 50 60 Compressor SCROLL SCROLL SCROLL RL Amps - LR Amps 19.9-105 21.8-117 26.8-134 Outdoor Fan FL Amps 0.93 0.93 0.93 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.5 Coil Spine Fin Spine Fin Spine Fin Refrigerant R-410A 9/2-LB/OZ 6/13-LB/OZ 8/0-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 Charge Spec. Subcooling 10 10 10 Dimensions H x W x D (Crated) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight - Shipping 228 235 261 Weight - Net 196 203 226 Start Components NO NO NO Sound Enclosure NO NO NO Compressor Sump Heat NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3* Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. 8 SSA-PRC009-E4

General Data 4TTA Product Specifications Model No. 1 4TTA3030A3 4TTA3030A4 4TTA3036A3 4TTA3036A4 Electrical Data V/Ph/Hz 2 200/230/3/60 460/3/60 200/230/3/60 460/3/60 Min Cir Ampacity 10 5 15 7 Max Fuse Size (Amps) 15 15 25 15 Compressor CLIMATUFF 30a3/30a4 CLIMATUFF 30a3/30a4 CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps 7.4-54.9 3.7-28 11.5-77 5.1-35 Outdoor Fan FL Amps 0.7 0.4 0.7 0.4 Fan HP 1/8 1/8 1/8 1/8 Fan Dia (inches) 23.0 23.0 23.0 23.0 Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 5/11-LB/OZ 5/11-LB/OZ 6/07-LB/OZ 6/07-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10 10 10 10 Dimensions H x W x D (Crated) 38 x 30.1 x 33 38 x 30.1 x 33 42 x 30.1 x 33 42 x 30.1 x 33 Weight - Shipping (lbs.) 224 222 229 227 Weight - Net (lbs.) 197 195 201 199 Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 BAY24X045 BAY24X045 Sound Enclosure BAYSDEN001 BAYSDEN001 BAYSDEN003 BAYSDEN003 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN2* TAYREFLN2* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] A-Weighted Sound Power Level [db(a)] A_WEIGHTED FULL OVTAVE SOUND POWER LEVEL db - [db(a)] 63 125 250 500 1000 2000 4000 8000 4TTA3030A3/4 78 49 60.2 66 70.3 71.4 69.8 60.4 53 4TTA3036A3/4 78 45.5 58.7 63.1 69.7 70 68.1 59 49.8 4TTA3042D3/4 79 47.5 64.5 67 75.3 74 70.7 62.2 52.8 4TTA3048D3/4 79 47.4 60 66.9 75.3 73.5 70.3 62 51.4 4TTA3060D3/4 80 47.3 55.7 69 72.7 75.8 69.4 62.2 53.3 Note: Rated in accordance with AHRI Stnadard 270-2008 SSA-PRC009-E4 9

General Data 4TTA Product Specifications Model No. 1 4TTA3060D3 4TTA3060D4 Electrical Data V/Ph/Hz 2 208/230/3/60 460/3/60 Min Cir Ampacity 21 10 Max Fuse Size (Amps) 35 15 Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps 15.6-110 7.8-52 Outdoor Fan FL Amps 0.93 0.6 Fan HP 1/5 1/5 Fan Dia (inches) 27.6 27.6 Coil Spine Fin Spine Fin Refrigerant R-410A 8/00-LB/OZ 8/00-LB/OZ Line Size - (in.) O.D. Gas 3 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 Charge Spec. Subcooling 10 10 Dimensions H x W x D (Crated) 42.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight - Shipping (lbs.) 261 261 Weight - Net (lbs.) 226 226 Start Components NO NO Sound Enclosure NO NO Compressor Sump Heat YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 Sound Enclosure BAYSDEN004 BAYSDEN004 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN3* TAYREFLN3* 1 Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. 10 SSA-PRC009-E4

General Data 4TTA Product Specifications Model No. 1 4TTA3042D3 4TTA3042D4 4TTA3048D3 4TTA3048D4 Electrical Data V/Ph/Hz 2 208/230/3/60 460/3/60 208/230/3/60 460/3/60 Min Cir Ampacity 18 8 18 8 Max Fuse Size (Amps) 30 15 30 15 Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL Amps - LR Amps 13.6-83 6.4-41 13.7-83 6.4-41 Outdoor Fan FL Amps 0.93 0.6 0.93 0.6 Fan HP 1/5 1/5 1/5 1/5 Fan Dia (inches) 27.6 27.6 27.6 27.6 Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 6/2-LB/OZ 6/2-LB/OZ 6/13-LB/OZ 6/13-LB/OZ Line Size - (in.) O.D. Gas 3 3/4 3/4 7/8 7/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10 10 10 10 Dimensions H x W x D (Crated) 34.4 x 35.1 x 38.7 38.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 38.4 x 35.1 x 38.7 Weight - Shipping (lbs.) 228 228 235 235 Weight - Net (lbs.) 196 196 203 203 Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow/Sand Legs - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow/Sand Legs - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Indoor Fan Delay Kit BAY24X045 BAY24X045 BAY24X045 BAY24X045 Sound Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Extreme Condition Mounting Kit BAYECMT001 BAYECMT001 BAYECMT001 BAYECMT001 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset 5 TAYREFLN7* TAYREFLN7* TAYREFLN3* TAYREFLN3 Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. SSA-PRC009-E4 11

General Data GAF MODEL RATED VOLTS/PH/HZ. RATINGS 1 INDOOR COIL Type Rows F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors H.P. Motor Speed RPM Volts/Ph/Hz F.L. Amps - L.R. Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) GAF2A0A18S11SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/3 825 208-230/1/60 2.0-4.1 No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 117/107 PRODUCT SPECIFICATIONS GAF2A0A24S21SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/4 1075 208-230/1/60 1.3-2.6 No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 120/110 GAF2A0A30S21SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/3 1075 208-230/1/60 1.7-3.5 No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 121/111 GAF2A0A36S31SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/2 1075 208-230/1/60 2.4-3.8 No Throwaway 1-16 X 20-1 in. R-410A Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 122/112 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76) 3 Constant torque Motor 4 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV4248A. 5 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV6060A. 12 SSA-PRC009-E4

Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A18 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A18S11SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 952 768 710 940 654 598 0.1 894 741 687 885 636 581 0.2 845 704 658 831 610 558 0.3 785 662 620 775 577 526 0.4 724 607 568 714 529 477 0.5 652 531 494 640 460 415 0.6 557 441 404 543 378 347 0.7 428 346 N/A 418 244 N/A 0.8 284 N/A N/A 225 N/A N/A 0.9 N/A N/A N/A N/A N/A N/A 1.0 N/A N/A N/A N/A N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A18S11SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 3 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 2 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 13

Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A24 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A24S21SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 998 848 771 899 737 658 0.1 949 816 745 868 710 630 0.2 911 784 711 834 683 602 0.3 869 750 679 794 650 567 0.4 825 708 638 756 611 524 0.5 772 659 586 704 547 476 0.6 707 591 518 641 499 415 0.7 614 513 444 555 420 346 0.8 533 416 356 465 339 268 0.9 413 309 218 351 203 138 1.0 241 130 N/A 167 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 2 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 14 SSA-PRC009-E4

Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A24 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A24S21SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 998 848 771 899 737 658 0.1 949 816 745 868 710 630 0.2 911 784 711 834 683 602 0.3 869 750 679 794 650 567 0.4 825 708 638 756 611 524 0.5 772 659 586 704 547 476 0.6 707 591 518 641 499 415 0.7 614 513 444 555 420 346 0.8 533 416 356 465 339 268 0.9 413 309 218 351 203 138 1.0 241 130 N/A 167 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A24S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 2 BAYECAA08LG1AA Tap 2 Tap 3 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 15

Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A30 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A30S21SA Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1052 967 932 1024 877 826 0.1 1012 929 898 980 846 800 0.2 963 888 861 934 814 771 0.3 914 849 823 885 777 738 0.4 865 805 784 837 739 703 0.5 816 759 741 788 697 663 0.6 759 698 681 739 640 602 0.7 690 622 592 668 559 515 0.8 589 503 463 559 423 395 0.9 389 336 318 375 285 259 1.0 179 149 119 175 NA NA NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A30S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 2 Tap 2 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 16 SSA-PRC009-E4

Airflow Data GAF EXTERNAL STATIC (in w.g) GAF2A0A30 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A30S21SA Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1052 967 932 1024 877 826 0.1 1012 929 898 980 846 800 0.2 963 888 861 934 814 771 0.3 914 849 823 885 777 738 0.4 865 805 784 837 739 703 0.5 816 759 741 788 697 663 0.6 759 698 681 739 640 602 0.7 690 622 592 668 559 515 0.8 589 503 463 559 423 395 0.9 389 336 318 375 285 259 1.0 179 149 119 175 NA NA NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A30S21SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 2 Tap 2 BAYECAA10LG1AA Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 17

Airflow Data GAF GAF2A0A36 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAF2A0A36S31SA Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1191 1146 1094 1040 1015 964 0.1 1180 1132 1085 1033 1004 959 0.2 1158 1110 1065 1014 984 942 0.3 1119 1082 1035 979 958 916 0.4 1079 1045 1003 942 923 887 0.5 1040 1005 969 907 886 857 0.6 993 960 927 864 843 818 0.7 934 910 877 808 795 772 0.8 880 855 816 758 742 715 0.9 815 786 748 696 675 650 1.0 744 715 677 629 607 583 NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A36S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 1 Tap 1 BAYECAA10LG1AA Tap 1 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 18 SSA-PRC009-E4

Airflow Data GAF GAF2A0A36 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAF2A0A36S31SA Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1191 1146 1094 1040 1015 964 0.1 1180 1132 1085 1033 1004 959 0.2 1158 1110 1065 1014 984 942 0.3 1119 1082 1035 979 958 916 0.4 1079 1045 1003 942 923 887 0.5 1040 1005 969 907 886 857 0.6 993 960 927 864 843 818 0.7 934 910 877 808 795 772 0.8 880 855 816 758 742 715 0.9 815 786 748 696 675 650 1.0 744 715 677 629 607 583 NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A36S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1AA Tap 1 Tap 1 BAYECAA08LG1AA Tap 1 Tap 1 BAYECAA10LG1AA Tap 1 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 19

General Data GAT MODEL RATED VOLTS/PH/HZ. RATINGS 1 INDOOR COIL Type Rows F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors H.P. Motor Speed RPM Volts/Ph/Hz F.L. Amps - L.R. Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) GAT2A0B42S31SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 5.04 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 10 1 Direct - 3 See Fan Performance Table 1-1/2 1075 208-230/1/60 2.7-5.0 No Throwaway 1-20 X 20-1 in. R-410A Brazed 7/8 3/8 H x W x D 56.8 x 23.5 x 24.5 55.7 x 21.3 x 21.8 144/133 PRODUCT SPECIFICATIONS GAT2A0C48S41SA 208-230/1/60 See O.D. Specifications Plate Fin 3-14 5.50 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 10 1 Direct - 3 See Fan Performance Table 1-1/2 1075 208-230/1/60 3.1-5.5 No Throwaway 1-20 X 22-1 in. R-410A Brazed 7/8 3/8 H x W x D 58 x 25.5 x 24.5 56.9 x 23.5 x 21.8 155/143 GAT2A0C60S51SA 208-230/1/60 See O.D. Specifications Plate Fin 4-14 5.50 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 10 1 Direct - 5 3 See Fan Performance Table 1-1 1050 208-230/1/60 7.6 - n/a No Throwaway 1-20 X 22-1 in. R-410A Brazed 7/8 3/8 H x W x D 62.8 x 25.5 x 24.5 61.7 x 23.5 x 21.8 171/159 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76) 3 Constant torque Motor 4 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV4248A. 5 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV6060A. 20 SSA-PRC009-E4

Airflow Data GAT GAT2A0B42 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAT2A0B42S31SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.2 1546 1421 1313 1449 1260 1120 0.3 1488 1380 1280 1401 1233 1099 0.4 1425 1329 1233 1348 1193 1065 0.5 1353 1264 1178 1281 1140 1023 0.6 1259 1182 1108 1202 1075 958 0.7 1145 1081 995 1102 965 868 0.8 982 909 839 926 817 753 0.9 788 759 731 761 713 N/A 1.0 563 N/A N/A 538 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0B42S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 3 Tap 1 BAYEABC20BK1AA Tap 3 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 21

Airflow Data GAT GAT2A0B42 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAT2A0B42S31SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.2 1546 1421 1313 1449 1260 1120 0.3 1488 1380 1280 1401 1233 1099 0.4 1425 1329 1233 1348 1193 1065 0.5 1353 1264 1178 1281 1140 1023 0.6 1259 1182 1108 1202 1075 958 0.7 1145 1081 995 1102 965 868 0.8 982 909 839 926 817 753 0.9 788 759 731 761 713 N/A 1.0 563 N/A N/A 538 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0B42S31SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 3 Tap 1 BAYEABC20BK1AA Tap 3 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 22 SSA-PRC009-E4

Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C48 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C48S41SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1904 1711 1541 1652 1455 1305 0.1 1881 1687 1529 1640 1450 1288 0.2 1844 1666 1511 1619 1425 1271 0.3 1806 1637 1485 1592 1410 1249 0.4 1766 1602 1454 1559 1381 1231 0.5 1716 1560 1420 1524 1351 1198 0.6 1659 1513 1380 1484 1321 1165 0.7 1594 1458 1333 1434 1283 1127 0.8 1525 1395 1277 1376 1229 1067 0.9 1442 1310 1194 1304 1149 N/A 1.0 1345 N/A N/A 1194 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C48S41SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 1 Tap 1 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 1 Tap 1 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 1 Tap 1 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 2 Tap 1 2 BAYEABC15BK1AA Tap 1 Tap 1 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 1 Tap 1 BAYEACC25BK1AA Tap 3 Tap 2 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS 1 Not qualified for 208V 2 Not qualified for 208V in upflow installations Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. SSA-PRC009-E4 23

Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C60 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C60S51SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 5 4 3 2 1 5 4 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582 0.2 2130 1889 1803 1667 1554 2121 1961 1795 1659 1545 0.3 2102 1850 1774 1628 1523 2090 1919 1763 1617 1511 0.4 2066 1818 1741 1596 1491 2052 1884 1727 1582 1477 0.5 2015 1785 1707 1564 1457 1998 1848 1690 1547 1440 0.6 1959 1754 1673 1520 1408 1939 1814 1653 1500 1389 0.7 1888 1716 1638 1477 1372 1880 1774 1615 1455 1349 0.8 1811 1680 1605 1440 1323 1820 1735 1580 1415 1298 0.9 1750 1628 1561 1403 1291 1770 1680 1533 1376 1263 1.0 1680 1604 1533 1368 1256 1725 1654 1503 1337 1226 NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C60S51SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 2 Tap 2 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 3 Tap 2 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 3 Tap 2 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 4 Tap 3 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 4 Tap 3 BAYEACC25BK1AA Tap 5 Tap 4 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #4 for the CTM motor. 24 SSA-PRC009-E4

Airflow Data GAT EXTERNAL STATIC (in w.g) GAT2A0C60 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAT2A0C60S51SA Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 5 4 3 2 1 5 4 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.1 2161 1916 1839 1696 1588 2155 1990 1833 1690 1582 0.2 2130 1889 1803 1667 1554 2121 1961 1795 1659 1545 0.3 2102 1850 1774 1628 1523 2090 1919 1763 1617 1511 0.4 2066 1818 1741 1596 1491 2052 1884 1727 1582 1477 0.5 2015 1785 1707 1564 1457 1998 1848 1690 1547 1440 0.6 1959 1754 1673 1520 1408 1939 1814 1653 1500 1389 0.7 1888 1716 1638 1477 1372 1880 1774 1615 1455 1349 0.8 1811 1680 1605 1440 1323 1820 1735 1580 1415 1298 0.9 1750 1628 1561 1403 1291 1770 1680 1533 1376 1263 1.0 1680 1604 1533 1368 1256 1725 1654 1503 1337 1226 NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAT2A0C60S51SA MINIMUM HEATER AIRFLOW CFM Heater Minimum Air Speed Tap With Heat Pump Without Heat Pump BAYEAAC05BK1AA Tap 2 Tap 2 BAYEAAC05LG1AA BAYEAAC08BK1AA Tap 3 Tap 2 BAYEAAC08LG1AA BAYEAAC10BK1AA Tap 3 Tap 2 BAYEAAC10LG1AA BAYEAAC10LG3AA Tap 1 Tap 1 BAYEABC15BK1AA Tap 4 Tap 3 BAYEABC15LG3AA Tap 1 Tap 1 BAYEABC20BK1AA Tap 4 Tap 3 BAYEACC25BK1AA Tap 5 Tap 4 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #4 for the CTM motor. SSA-PRC009-E4 25

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model Indoor model 4TTB3018G1 ARIREF 5612718 Airflow 600 GAF2A0A18S11+TDR Values At ARI rating conditions Total Net capacity 19300 Btuh Airflow 600 CFM Compressor power 1448 watts Indoor fan power 176 watts Outdoor fan power 131 watts SEER 13 Correction factors - other airflows Airflow 525 675 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 18.1 14.6 16.3 18 17.9 1.55 85 63 19 11.9 13.7 15.4 16.6 1.56 85 67 20.3 9.4 11.2 12.9 14.1 1.57 95 59 17.2 14.1 15.9 17.2 17.2 1.72 95 63 18.1 11.6 13.3 15 16.2 1.74 95 67 19.3 9.1 10.8 12.5 13.7 1.75 105 63 17.1 11.1 12.9 14.6 15.8 1.92 105 67 18.3 8.7 10.4 12.2 13.3 1.93 105 71 19.9 6.3 8.05 9.8 11 1.95 115 63 16.2 10.8 12.5 14.3 15.4 2.09 115 67 17.3 8.3 10.05 11.8 13 2.11 115 71 18.8 5.9 7.7 9.4 10.6 2.14 *** 95 67 19.3 IDDB= 80 13.7 1.75 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 26 SSA-PRC009-E4

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model 4TTB3018G1 Indoor model GAF2A0A24S21+TDR ARIREF 5612719 Airflow 600 Values At ARI rating conditions Total Net capacity 19700 Btuh Airflow 625 CFM Compressor power 1468 watts Indoor fan power 192 watts Outdoor fan power 131 watts SEER 13 Correction factors - other airflows Airflow 525 675 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 18.4 15 16.8 18.4 18.4 1.58 85 63 19.2 12.2 14 15.8 17 1.6 85 67 20.6 9.6 11.45 13.3 14.5 1.61 95 59 17.5 14.5 16.35 17.5 17.5 1.77 95 63 18.3 11.8 13.6 15.4 16.6 1.78 95 67 19.6 9.3 11.1 12.9 14.1 1.8 105 63 17.4 11.4 13.25 15.1 16.3 1.97 105 67 18.6 8.9 10.7 12.5 13.7 1.98 105 71 20.1 6.4 8.2 10 11.2 2 115 63 16.4 11 12.8 14.7 15.9 2.15 115 67 17.6 8.5 10.3 12.1 13.3 2.17 115 71 19 6 7.8 9.6 10.8 2.19 *** 95 67 19.6 IDDB= 80 14.1 1.8 *** Performance at selected design conditions * Dry coil condition (Total capacity = Sensible capacity) Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 27

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model Indoor model 4TTB3024G1 ARIREF 5668903 Airflow 800 GAF2A0A18S11+TDR Values At ARI rating conditions Total Net capacity 24200 Btuh Airflow 675 CFM Compressor power 1877 watts Indoor fan power 195 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow 675 925 Total capacity 0.98 1.03 Sensible capacity 0.91 1.09 Compressor kw 0.99 1.01 Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 23.3 19 21.3 23.3 23.3 1.88 85 63 24.4 15.5 17.85 20.1 21.7 1.89 85 67 26.1 12.3 14.55 16.9 18.4 1.91 95 59 22.3 18.5 20.85 22.3 22.3 2.11 95 63 23.4 15.1 17.45 19.7 21.3 2.13 95 67 25 11.9 14.15 16.5 18 2.15 105 63 22.4 14.7 17 19.3 20.8 2.37 105 67 23.9 11.4 13.75 16 17.6 2.39 105 71 26 8.3 10.6 12.9 14.4 2.41 115 63 21.4 14.3 16.6 18.9 20.4 2.6 115 67 22.9 11.1 13.35 15.7 17.2 2.63 115 71 24.8 7.9 10.2 12.5 14 2.65 *** 95 67 25 IDDB= 80 18 2,15 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 28 SSA-PRC009-E4

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model 4TTB3024G1 Indoor model GAF2A0A24S21+TDR ARIREF 5668904 Airflow 800 Values At ARI rating conditions Total Net capacity 25000 Btuh Airflow 750 CFM Compressor power 1917 watts Indoor fan power 228 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow 700 900 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 23.5 19.1 21.45 23.5 23.5 1.97 85 63 24.7 15.7 18 20.3 21.8 1.99 85 67 26.4 12.3 14.65 17 18.5 2 95 59 22.6 18.7 21 22.6 22.6 2.21 95 63 23.7 15.2 17.55 19.9 21.4 2.23 95 67 25.3 11.9 14.25 16.6 18.1 2.25 105 63 22.7 14.8 17.15 19.5 21 2.48 105 67 24.2 11.5 13.85 16.2 17.7 2.5 105 71 26.3 8.3 10.65 13 14.5 2.53 115 63 21.7 14.4 16.75 19.1 20.6 2.73 115 67 23.1 11.1 13.4 15.7 17.3 2.75 115 71 25.1 7.9 10.25 12.6 14.1 2.78 *** 95 67 25.3 IDDB= 80 18.1 2.25 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 29

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model Indoor model 4TTB3024G1 ARIREF 5668905 Airflow 800 GAF2A0A30S21+TDR Values At ARI rating conditions Total Net capacity 25000 Btuh Airflow 825 CFM Compressor power 1889 watts Indoor fan power 256 watts Outdoor fan power 128 watts SEER 13 Correction factors - other airflows Airflow 700 900 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 5/8 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 23.3 19 21.35 23.3 23.3 2.01 85 63 24.4 15.5 17.85 20.2 21.8 2.02 85 67 26.1 12.2 14.55 16.9 18.4 2.04 95 59 22.2 18.5 20.85 22.2 22.2 2.24 95 63 23.3 15.1 17.4 19.7 21.3 2.26 95 67 24.9 11.7 14.1 16.4 18 2.28 105 63 22.1 14.6 16.9 19.2 20.8 2.5 105 67 23.6 11.3 13.6 15.9 17.5 2.52 105 71 25.6 8 10.4 12.7 14.3 2.54 115 63 21 14.1 16.45 18.8 20.4 2.73 115 67 22.4 10.8 13.15 15.5 17 2.76 115 71 24.3 7.6 9.95 12.3 13.8 2.78 *** 95 67 24.9 IDDB= 80 18 2.28 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 30 SSA-PRC009-E4

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model 4TTB3030G1 Indoor model GAF2A0A24S21+TDR ARIREF 5724150 Airflow 1000 Values At ARI rating conditions Total Net capacity 29200 Btuh Airflow 900 CFM Compressor power 2244 watts Indoor fan power 287 watts Outdoor fan power 124 watts SEER 13 Correction factors - other airflows Airflow 875 1125 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 27.8 22.9 25.65 27.8 27.8 2.28 85 63 29.2 18.7 21.45 24.3 26.2 2.3 85 67 31.2 14.6 17.45 20.3 22.2 2.32 95 59 26.6 22.3 25.15 26.6 26.6 2.57 95 63 27.9 18.1 20.95 23.8 25.7 2.59 95 67 29.8 14.1 16.95 19.8 21.6 2.62 105 63 26.6 17.6 20.45 23.2 25.1 2.89 105 67 28.4 13.6 16.4 19.2 21.1 2.91 105 71 30.8 9.7 12.55 15.4 17.2 2.94 115 63 25.3 17.1 19.9 22.7 24.6 3.18 115 67 27 13.1 15.85 18.7 20.6 3.21 115 71 29.3 9.2 12.05 14.8 16.7 3.24 *** 95 67 29.8 IDDB= 80 21.6 2.62 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 31

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model Indoor model 4TTB3030G1 ARIREF 5724151 Airflow 1000 GAF2A0A30S21+TDR Values At ARI rating conditions Total Net capacity 29000 Btuh Airflow 900 CFM Compressor power 2242 watts Indoor fan power 270 watts Outdoor fan power 124 watts SEER 13 Correction factors - other airflows Airflow 875 1125 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 27.6 22.7 25.45 27.6 27.6 2.27 85 63 29 18.5 21.35 24.1 26 2.29 85 67 31 14.5 17.35 20.1 22 2.31 95 59 26.4 22.1 24.95 26.4 26.4 2.55 95 63 27.7 18 20.8 23.6 25.5 2.58 95 67 29.6 14 16.8 19.6 21.5 2.6 105 63 26.4 17.5 20.25 23.1 24.9 2.86 105 67 28.2 13.5 16.3 19.1 21 2.89 105 71 30.6 9.7 12.45 15.3 17.1 2.92 115 63 25.1 16.9 19.75 22.5 24.4 3.15 115 67 26.8 13 15.75 18.6 20.4 3.19 115 71 29.1 9.1 11.95 14.8 16.6 3.22 *** 95 67 29.6 IDDB= 80 21.5 2.6 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F 32 SSA-PRC009-E4

Performance data Capacities are net in Btuh/1000 - indoor fan heat deducted Outdoor model 4TTB3030E1 Indoor model GAF2A0A36S31+TDR ARIREF 5274232 Airflow 1000 Values At ARI rating conditions Total Net capacity 29600 Btuh Airflow 1025 CFM Compressor power 2328 watts Indoor fan power 363 watts Outdoor fan power 0 watts SEER 13 Correction factors - other airflows Airflow 875 1125 Total capacity 0.98 1.02 Sensible capacity 0.93 1.07 Compressor kw 0.99 1.01 Rated with 25 Feet 3/4 suction 3/8 liquid lines O.D.D.B. I.D.W.B. Total capacity Sensible capacity SYSTEM 72 75 78 80 kw 85 59 28.1 23.1 26 28.1 28.1 2.42 85 63 29.5 18.8 21.7 24.6 26.5 2.44 85 67 31.5 14.7 17.55 20.5 22.4 2.46 95 59 26.3 22.3 25.2 26.3 26.3 2.65 95 63 27.6 18 20.95 23.8 25.7 2.67 95 67 29.5 13.9 16.85 19.7 21.6 2.7 105 63 25.7 17.3 20.15 23 25 2.91 105 67 27.5 13.2 16.05 19 20.9 2.93 105 71 29.8 9.2 12.1 15 16.9 2.96 115 63 23.8 16.5 19.4 22.3 23.8 3.14 115 67 25.5 12.4 15.35 18.2 20.2 3.17 115 71 27.6 8.5 11.35 14.3 16.2 3.2 *** 95 67 29.5 IDDB= 80 21.6 2.7 *** Performance at selected design conditions Total capacity, compressor kw and app. dew point valid only for wetcoil All temperaturest in Degree F SSA-PRC009-E4 33