Our energy efficient experts and engineers have made ground breaking innovations in this field.

Similar documents
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

1.1 This section applies to air handling units for HVAC Systems.

Air Make-Up Units. Product Line Overview & Capabilities

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

MODEL NUMBER NOMENCLATURE

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

62DA,DB,DC,DD,DE,DF07-38

DIVISION 15 MECHANICAL

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

THE ULTIMATE ROOFTOP SOLUTION

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AFD Industrial Dehumidifier Series

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Energy Recovery with Cooling and Heating

AIR HANDLER SPECIFICATION

48PGD/E/F/L/M/N PG20-28

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

ALL PRODUCTS BROCHURE

Energy Recovery with Cooling and Heating Model ERCH

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Air Handling Units. Real HVACR people who understand your needs.

INTRODUCTION. Heat Pipe Technology, Inc. The Heat Pipe Principle. Recent Heat Pipe Development

Heat pump and energy recovery systems

COMcheck Software Version Mechanical Compliance Certificate

Closed Circuit Cooling Towers

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Questions??????? Thank you

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

DES CHAMPS PRODUCTS 85% 4,400 CFM

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Glossary of Terms Laboratory & Fume Exhaust Fans

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

The ultimate fresh air solution.

TYPICAL CPA SPECIFICATIONS

XeteX, Inc. All Rights Reserved.

Cultivator & Hybrid Cultivator

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Kitchen Exhaust Air Cleaning Systems

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Contents INDEX. TDM Series Indirect Fired Heaters

Double Skin Casing Air Handling Units

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

WELD STRONG BREATHE FREE

Air Marketing Group 110

VERTICAL FAN COIL UNITS

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

Heat Recovery Units. Heat Recovery 1

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Centeral Station Air Handling Unit

RT-OA TM Rooftop Outdoor-Air (DOAS)

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Liquid desiccant dehumidification systems. Product guide

AFD DEHUMIDIFIER SERIES

RoofPak Applied Rooftop Systems

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Pharmaceutical Facility Design

Tulsa, OK Longview, TX

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Bill McCullough. Director ERV Products. Dallas, TX

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Module 7: Air Supply System

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Modular Supply Make-Up Air Unit

FAS-300 Central Dust Collection Systems

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream.

MiniCore Ventilator (500, 1000) Series Engineering Guide

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Supplying Clean Air to Industry

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

We make air handling technology. Better.

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

ASME Packaged Indirect Fired Water Heater

Modular Active. Chilled. Beams

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Transcription:

Company Profile Introduction: We are pleased to introduce ourselves as MAFNA Air Technologies Inc., established in 1999. MAFNA Air Technologies Inc, is Canada's leading manufacturer and supplier of Air conditioning products. We offer expert solutions for all your cooling and heating needs. From schools to factories, we have catered to various schools to commercial applications in North America. We provide cost effective solutions for variety of energy saving needs. We are dedicated to bringing you the finest in custom built heat recovery units, rooftop units, air handling units, explosion proof units, Lab Exhaust, desiccant dehumidification unit, pool dehumidification unit, custom built fan coil units, fluid cooler unit, exhaust recovery unit, custom built pre-fabricated mechanical/boiler room, chilled beam units and many more. Our motto is We adapt our ENGINEERING to meet the requirements of your CUSTOM APPLICATIONS. We've been following this motto for the past 15 years. Our energy efficient experts and engineers have made ground breaking innovations in this field. Manufactured in our state of art facility, MAFNA produces sustainable products with full compliance to the specification. Mafna offers high quality construction units featuring fully welded structural bases and interior hemmed panels. Mafna offers fiberglass insulation, double wall construction in varying thicknesses and also a foam injected core construction featuring a unique tongue and groove construction for the ultimate in thermal break; it is lightweight and has a very durable casing.

Overview Overview: The ALTITUDE is intended for use in exhausting laboratory/hazardous fumes in a safe and efficient manner while simultaneously recovering energy. The Altitude was developed for use in applications such as: Laboratories Pharmaceuticals Chemical & Petrochemical Waste Water Odor Control Hospitals Chemical Storage Hazardous Region Benefits: Prevent re-entrainment ALTITUDE sends a vertical jet plume of diluted exhaust gas up to 350 high, providing atmospheric disbursement and reventing exhaust from re-entering the facility through fresh air supply ventilation systems, doors, and windows. Eliminate odor The ALTITUDE effectively eliminate odors, preventing them from entering the facility and neighboring buildings. Reduce noise ALTITUDE is offers a number of noise attenuation accessories. Lower energy costs Energy consumption is minimized with combination of Altitude and Energy Recovery System.

Features : Heating and Cooling up to 80,000 cfm External static pressure up to 8 in. wg Induced flow windband Mixed flow wheel design High velocity plume dispersion nozzle Wheel diameters from 12.5" through 66" Direct Drive with VFD Spark Resistant option available Three discharge nozzles available per size 125 mph wind load capability Construction : Casing Construction : Stainless Steel, Aluminum, Steel, Thermal break Casing are available. Wall Thickness : 2-4 inch thick Double Wall Construction. Wall using injected foam construction. 2.0 fiberglass or PU Foam insulation. Base: 4,6,8 inches Formed Steel Channel.. Floor: 14 Ga. Epoxy coated. Filters : 2-4 inch MERV 8 Pleated Pre-filters. Optional Secondary Filters (MERV 11-15), Carbon available. Coils : Aluminum Fins with copper tubing in Galvanized Casing. Optional Copper Fins, Stainless steel Casing available. Drain Pans: 16 G Stainless Steel drain pans Access Doors/Panels for Fan sections : Aluminum frame with continuous SS piano hinge with view port and test ports. Roof Curb: Optional 16"Heavy-duty coated steel curb available. Warranty: The product is warranted against manufacturing defects for 1 year from the date of manufacturing.

ALTITUDE with Energy Recovery System: The conditioned air exiting the laboratory contains energy that's going to waste. You can reduce your cooling costs by capturing energy and recycling it. The exhaust air extracts the heat from the medium(water or a water/anti-freeze mix) via heat exchanger and the cold water is transferred to a heat exchanger located in a hot stream of incoming outside air. A pump keeps the system circulating. Because the unit is sealed, it can transfer heat energy from contaminated exhaust air to incoming fresh air without degrading the quality of the incoming air. The exhaust fan induces clean, external air and mixes it with the contaminated building exhaust to dilute the air and increase the outlet volume, exhausting the air at a high velocity to prevent the fumes from re-entering the buildings intake or make-up air.