Dual-Mode Infrared Thermometer Instruction Manual

Similar documents
Forehead Thermometer Instruction manual

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

CLETEF-786. Infrared Thermometer Instruction Manual

Forehead Thermometer Instruction Manual

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Instructions. Consumer Info-Line

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

NON-TOUCH THERMOMETER User Manual

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

No Touch Thermometer

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

Kinsa Smart Ear ThermometerTM Instructions For Use

Forehead Infrared Thermometer

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

THERMOFOCUS 0800H5 Professional

CareTemp Touch Free Thermometer. Directions for use

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

for a healthy world Product catalogue 2010/ 2011

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

T5000 LCD Digital Fan Coil Thermostat

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

TM-802 Formaldehyde Meter User s Manual

EST User Manual. (Please read this manual carefully before using)

KM300 Carbon Monoxide Detection System Installation Manual

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

The design of the human body infrared thermometer

Analog Room Pressure Monitor RPC Series

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Ambient Weather WS-DP02 Digital Psychrometer with Temperature, Humidity, Heat Index, Dew Point, Wet Bulb Temperature and Clock User Manual

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

WIRELESS FRIDGE THERMOMETER Instruction Manual

Manual PCE-889 pyrometer

High Resolution Display WIRELESS COLOR WEATHER STATION


HIn3550 Magnetic Field Monitor User's Manual

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

WIRELESS COLOR WEATHER STATION

Users Manual. Air Velocity Meter

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Commodity Description

Product catalogue

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

T-32-TS Touchscreen Thermostat. Installation Manual

MOONPHASE WALL CLOCK Instruction Manual

This instruction manual explains the use of three models listed on the left.

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Oxygen Monitor Operating Manual

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Dual Laser InfraRed (IR) Thermometer

Refrigerator/Freezer Thermometer

Indoor/Outdoor Temperature Alert

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

INSTRUCTION MANUAL. Model: 8918 THERMO HYGRO-ANEMOMETER KNT BF FPM MPH MS CKMH

WBGT Heat Stress Meter

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Refrigerator/Freezer Thermometer

WS3650IT-MG-SIL. Technical sheet

Precision Infrared Thermometer. Users Manual

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

WIRELESS COLOR FORECAST STATION

PDA20DX Air Purifying Dehumdifier Manual

Concrete and Mortar Moisture Tester Model HI-520. Operating Manual

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

KANE-ALERT-CO 2 Monitor with Temperature

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Ambient Weather WS-25 Wireless 8-Channel Floating Pool and Spa Thermometer with Indoor Temperature and Humidity User Manual

CONTENTS. La Crosse Technology, Ltd. Page 1

USER GUIDE Heat Index Psychrometer

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Operating Guide. English Version 3.3

Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

Transcription:

0482 Dual-Mode Infrared Thermometer Instruction Manual 9 1

Introduction Thank you for choosing the Dual-mode Digital Infrared Thermometer, Dual-mode infrared thermometer for short. With the unique technology, the Dual-mode infrared thermometer can give the result with Dual-mode, stable measurement and without the interference from ambient temperature. The product will self-test every time it starts up to make sure the normal operation and accuracy. The Dual-mode infrared thermometer can be used to read the body temperature by measure the ear and forehead temperature, which is suitable for adult and children (ear test mode only for the child above 3 months). Please read the instructions carefully before using the product, and put it in a safe and secure place for reference. 11.Memory function Memorize 20 groups of measured temperature. 12.Current consumption 13.LED backlit specifications 15.Operational conditions 16.Type of measuring 17.battery 18.Battery life 19.Accuracy for clinical test Istand-by<2μA; Iworking<0.5mA; IBuzzer on<2ma; Ibanklight<15mA 1.2cd/m 2 ASTM 10-40 (50-104 )/15-95%RH Applicable for forehead temperature and ear temperature Changeable for two 1.5V triple AAA batteries More than 3000 times The maximum allowable error for clinical test is specified in the formula below: Terror = T1-Tref 0.3 /0.6 (for 95%) Among which: T1 and T2 represent temperature value for thermometer under test respectively, Tref represents the constant reference temperature 8. After-sale service The device is under warranty for one year since the date of acquisition. Application for repairing should be presented during the warranty period. The damage caused by improper use is not under warranty scope. Batteries and packaging are not under warranty scope as well. + 2 T2-Tref 9. Security type The signal indicates that the thermometer is a BF type device with internal power supply. 10. Authorized European Representative: Wellkang Ltd Suite B, 29Harley Street, LONDON, W1G9QR,U.K. 2 8

Attention: Electromagnetic interference: Dual-mode Infrared Thermometer contains sensitive electronic component and shall not use under the condition with electromagnetic interference,( such as the place nearby the mobile phones and microwaves ) Please dispose the used products and batteries in accordance with local regulation requirements when the products and batteries are not available. Please take out the battery if the device unused for long time. 7. Technical specifications Items Standards models Dual-mode infrared thermometer 1.Applicable regulations and ASTM 1965/EN12470-5/GB/T 19146-2010 laws 2.Temperature units /, adjustable Forehead temperature mode:32.0-42.2 / 3.Measurement 89.6 F 107.9 F range ear temperature mode:0.0-100.0 /32.0 F 212.0 F 4.Precision ±0.2 /±0.4 F 5.Display resolution 0.1 /0.1 6.Latency Time 1 second LCD s L if the measured temperature is below the minimum of measurement range. LCD s H if the measured temperature is below the minimum of measurement range. 7.Abnormal state LCD s Er1 if the temperature measurement circuit is abnormal (fault of SENSOR or the temperature measurement circuit), or the ambient temperature exceed 10 ~40 (50-104 ). There shall be ErC if the calibration process is not completed or EEPROM is abnormal. volume 50 db (the perpendicular distance from db 8.Sound Volume sensor to thermometer is 10cm ) 9.Automatic 10s±1s shutdown function 10.Low-voltage function The product shall low-voltage signal if the voltage is below 2.51V±0.15V. Contents 1.The advantages of Dual-mode infrared thermometer...1 2.Necessary safety instructions...2 3.Instructions for product designs...3 4.How to measure the forehead temperature...3 5.How to measure the ear temperature...3 6.Instructions for and operation...4 7.Technical spcifications...7 8.After-sale service...8 9.Security type...8 10.Authorized European Representative...8 7 3

1. The advantages of Dual-mode infrared thermometer Multiple use (measurement of forehead temperature and ear temperature) Thanks to Dual-mode design, you are free to take body temperature by detecting the infrared heat given off by the forehead,which is from 32 to 42.2 (from 89.6 to 107.9 ), and by the eardrum, which is from 0 to 100.0 (from 32.0 to 212.0 ). The product consists of ABS plastics, temperature sensor, Infrared temperature measuring element, microcomputer controlled circuit, LCD, backlight and buzzer. Convenient for use Special ergonomic design to facilitate operation. No inconvenience would be caused to your daily life. It s available for measurement when your children s sleeping. It provides comfortable user experience compared with anus thermometer for children, rapid reading and simple operation compared with mouth thermometer. Memory recall A maximum of 20 previous readings is available to help you track the trend of your body temperature. Safe and hygienic Compared to mercury thermometer, there is no danger of breaking the glass or swallowing mercury. It is totally safe for children to use. Fever warning When the reading exceeds 37.5 /99.5, this product shall warn the user that he/she may have a fever by 7 rapid and short rings with LCD flicker.(for normal forehead temperature, the signal is long ring with LCD no flicker) Extensive clinical data from hospital The cooperation with designated hospitals is subjected to precise clinical verification, with the support of extensive clinical data and professional medical experts. measured data and mode icon. There are 20 groups of data. The LCD shall only - - -, / and M signal with M signal twinkling if there is no test data. C/F conversion LCD Operational steps Press button F2 for 8-12seconds under shutdown state, and the temperature unit shifts automatically. Press button F2 within 5 seconds after release, and the temperature unit shifts again unless the release time exceeds 5 second. The products shall be automatic startup and enter into the ear Error message It shall Er1 when ambient temperature exceeds 40.0 /104 or drop below 10.0 /50.0. It shall ErC if there is EEPROM data reading error or the correcting process is not finished. Please contact your supplier. Sound and backlit 3 short tick and green backlit for 3seconds. 3 short tick and green backlit for 3seconds. There shall be low-voltage signal (no twinkling) when the battery voltage is below2.61v±2%. Please replace the battery. Power Off Mode In any mode, if no operation for 10 seconds, it will power off automatically. 1 6

or or startup mode and enter measurement mode again. Attention: There shall be 7 short rapid ticks and LCD flicker when the measured temperature exceed 37.5 /99.5, which is a warning for patients that he/she may have a fever Ready for detection, the relative symbol shall twinkle. 1. The measured value exceeds 100 /212.0 under ear 2.The measured value exceeds 42.2 /107.9 under forehead 1. The measured value exceeds 0 /32.0 under ear temperature mode. 2. The measured value exceeds 32 /89.6 under forehead Inquiry for memory data, Storing 20 groups of data LCD Operational method and instruction for s Click button F2 for 4-8seconds and LCD s - - - with M signal twinkling. Click button F2 again and the LCD s the first data group with M signal twinkling. Click button F2 and it shall the serial number for 1 second and then the there shall be 7 short ticks and green backlit for 3 seconds 3 short tick and green backlit for 3seconds. 3 short tick and green backlit for 3seconds. Sound and backlit 2. Necessary safety instructions The device is not used for newborn baby. The device is not continuous monitoring device. Dual-mode Infrared Thermometer is not waterproof. Please do not douse it into water or other liquids. Cleaning and disinfection procedure shall be in comply with the instructions specified in [cleaning and storage] Please do not use the product if the temperature sensor or the Dual-mode infrared thermometer shows any sign of damage. Do not try to repair the product if it is damaged. Please contact the nearest Customer Service. Dual-mode Infrared Thermometer consists of precision parts with high quality. Please prevent the product from falling off. Protection shall be provided for no intense shock and vibration. Do not twist the Dual-mode infrared thermometer and the temperature sensor. Operating Conditions: Temperature: 10 C to 40 C Humidity: <80% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Storage and Shipping Conditions: Temperature: -10 C to 60 C Humidity: 0-95% RH, non-condensing Atmospheric pressure: 860hPa to 1060hPa Battery Installation: Put the two AAA batteries into battery compartment in correct polarities. Push the battery cover horizontally along the arrow. Notes: If you are the first time using the thermometer, please pull out the Plastic sheet. Battery polarities should be correctly installed. Otherwise, damage may be caused to the device. Please put in or remove batteries in right order, or may cause damage to the device bracket. Please remove the batteries if the thermometer will not be used for a long time. Warnings Please keep this Dual-mode infrared thermometer out of children s 5 2

reach Medical assistance can t be replaced by the use of infrared Dual-mode infrared thermometer The Dual-mode infrared thermometer is not waterproof! Keep it away from water. 3.Instructions for product designs (1) Sensor (Take off the cover before detecting the eardrum temperature) (2) F1: start detection of forehead temperature (3) F2: start detection of eardrum temperature (4) LCD (5) Battery cover 4.How to measure the forehead temperature Hold Button F1, scan the forehead from one side to the other and then release the button when the thermometer is off. Now you can see the temperature reading on LCD. Detecting temperature on a point may result in inaccurate reading. You can take another measurement when the backlight is off. 5.How to measure the ear temperature Take off the sensor cover; insert the sensor into the ear canal. Then press the button F2 when the thermometer is off, the temperature reading is shown on LCD. You can take another measurement when the backlight is off. In order to avoid the inaccuracy: (1)Please make sure that there is no dirt in on the temperature sensor (2)Please make sure that the device only be used in room, and there is no strongly conversation of wind. (3)Before you measuring the forehead temperature, there shall be no water or any shade on the forehead. (4) Before you measuring the ear temperature, please clean the ear canal first. (5)Please make sure that there is no intense emotion and movement before measuring. (6)If Dual-mode Infrared Thermometer is transferred from one condition to another which has different ambient temperature, it is suggested to deposit for more than 30 minutes, and please follow the rule (2). (7)If the tester is transferred from one condition to another which has different ambient temperature, it is suggested to have a rest for more than 10 minutes, and please follow the rule (2). (8)Do not hold Dual-mode Infrared Thermometer for long time as it is highly sensitive to heat. Dual-mode Infrared Thermometer has undergone clinical test, it is safe and accurate when using in accordance with operation manual. 6. Instructions for and operation LCD Operational method and instruction for s 1.Measurement of forehead temperature 1 Measurer the forehead temperature under shutdown state, please press button F1 or hold down button F1, it shall measured value when releasing button, which is under forehead Holding down the button and scanning over the forehead are suggested. The system will read sequentially and record the maximum 2.Measurement of ear temperature Press button F2 within 4 seconds and release it under shutdown state. It shall measured value, which is under ear 3. Press button F2 or F1 under Sound and backlit 1. Forehead temperature mode : 32.0 /89.6 <=t <37.6 /99.6 Ear temperature mode: 0.0 / 32.0 <=t <37.6 / 99.6,there shall be one long ring and green backlit for 3 seconds. 2. Forehead temperature mode : 37.6 / 99.6 <=t <42.2 / 107.9 Ear temperature mode: 37.6 / 99.6 <=t <100 / 212 3 4