Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Similar documents
Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

onlinecomponents.com

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

Ultrasonic Reflective Sensor

Ultrasonic Proximity Sensor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

E3M-V. Mark Sensor. Applications

Ultrasonic Reflective Sensor

E3FA PHOTOELECTRIC SENSORS

Model Number Structure

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

E3FA PHOTOELECTRIC SENSORS

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

E3FA PHOTOELECTRIC SENSORS

Scale 0: 10 k Scale 50: 10 k (see note 2)

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Reliable Detection of Transparent Objects

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Ultrasonic Proximity Sensor

Original instructions Sense7-series Non-contact coded safety switch

Reliable Detection of Transparent Objects

E3ZM Stainless Steel Photoelectric Sensors

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

E3FA PHOTOELECTRIC SENSORS

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Original instructions JSNY7 Magnetic switch

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Class 1 laser beam sensor safe for your eyes

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Class 1 laser beam sensor safe for your eyes

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Class 1 laser beam sensor safe for your eyes

Mark and Colour Sensors

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

Sensing for standard and special applications

Background suppression photo sensors

MINI-BEAM Expert Series

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Plug-in Base, Long Range Sensor E3B2

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Products designed for extreme washdown environments IP69K Products

Laser Collimated Beam Sensor

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

TEMPERATURE CONTROLLER

Flameproof Type Light Curtain Type 4

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Annuciator Logic Controllers

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

Retro-reflective Sensing range: 0mm to 2000mm

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

CAUTION WARNING CAUTION WARNING INSTRUCTION MANUAL 1. SAFETY PRECAUTIONS

2 General Application Photoelectric Sensors

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Automatic Self-Adjusting General Purpose Sensor

2 General Application Photoelectric Sensors

AnyWireASLINK System Products Guide

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Sintrol Snifter A1+ Manual. Version 1.2.2

Polarized Retroflective Photoelectric Switches

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

2 General Application Photoelectric Sensors

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

E3NX-MA. Smart Fiber Amplifier Units. Downsize control panels using the Omron dualchannel. Ordering Information

5.0. Photoelectric Sensors. Technical Reference. Introduction

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Laser Distance Sensor Type M Analog-Output

The Affordable, All-Purpose Sensor That's EZ To Use!

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

BOS 23K. Photoelectric Sensors BOS 23K

2 General Application Photoelectric Sensors

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Duct Humidity/Temp Sensor

Transcription:

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor CSM DS_E_4_4 Excellent PET Bottle Detection New detection method that is independent of bottle shape, position, and contents. Automatic compensation against effects of contamination and temperature (except @T). Product lineup includes models with adjuster (@T). Detects transparent objects made by PET, resin, and glass. Refer to Safety Precautions on page 0. Features Industry Top P-opaquing and a Coaxial Optical System Eliminate Dependence on the Bottle's Shape, Position, Transparency, and Contents. P-opaquing: Polarization-opaquing Patented (Refer to page 9 for a technical description.) The more than triples conventional detection performance, with outstanding stability. Relative light reception (%) 20% 00% 80% 60% 40% 20% Rate of decrease: Approx. 70% 0 5 More than Triples the Performance * Rate of decrease: Approx. 20% 80 50 * 0% Industry Top With no PET bottle With PET bottle With no PET bottle With PET bottle Former OMRON product *Depending on the shape and position of the PET bottle. AC Function Automatically Compensates Effects of Soiling and Temperature AC : Auto Compensation Control for Contamination Patented (Refer to page 9 for a technical description.) Parameters require resetting when static electricity causes dust to adhere to the surface of the Sensor or Reflector, or when the light emission power drops due to temperature- or time-related changes. Original OMRON light emission control technology greatly reduces the resetting work involved. Initial Condition... Contamination... Auto Compensation

Teaching with No Workpiece Required -- Quick and Easy Setting There is no need for delicate sensitivity adjustments. Simply adjust the optical axes of the Sensor and Reflector, then press the Teaching button twice. This high-reliability design eliminates worries about variations in the sensitivity settings of different operators. Industry Top IP69K Degree of Protection with an SUS6L Housing The housing is constructed of corrosion-resistant SUS6L, and the display cover is PES (polyethersulfone). Both materials are highly resistant to the effects of detergents and disinfectants. IP69K degree of protection also allows the to withstand washing with high-temperature, high-pressure water. This makes the well suited to use in sites requiring a high level of hygiene. A Wide Ambient Temperature Range of 40 to 60 C This wide temperature range meets the needs of the many and diverse applications in the beverage industry. Applications Detecting Plastic Bottles Precautions for Correct Use The @/-B@6 are not applicable for detecting transparent objects that exhibit no birefringence, such as glass bottles. Transparent objects made of resin also exhibit little birefringence, and cannot be detected with complete stability. Check the detection stability of objects such as these prior to actual operation. 2

Ordering Information Sensors [Refer to Dimensions on page 2.] Sensing method Retroreflective with MSR function Appearance Sensitivity adjustment Teaching type One-turn adjuster type Connection method Sensing distance Special reflector Pre-wired (2 m) *2 Order Connector separately (M8, 4 pins) Pre-wired (2 m) *2 Included Connector (M8, 4 pins) 500 mm Pre-wired [00 mm]* (2 m) Order Connector separately (M8, 4 pins) Pre-wired (2 m) Included Connector (M8, 4 pins) *. Values in parentheses indicate the minimum required distance between the Sensor and Reflector. *2. Models with a 5-m pre-wired cable are also available. When ordering, add the cable length to the end of the model number (e.g., 6 5M). Accessories Special Retroreflective Reflector (A Retroreflector is provided depending on the model number. Check the model number in the remarks column.) [Refer to Dimensions on page 2.] Name Model Model NPN output 6 2M 66 6-C 2M 66-C 6T 2M 66T 6T-C 2M 66T-C Sensing distance (rated) Quantity Remarks @(T)/-B@6(T) PNP output 8 2M 86 8-C 2M 86-C 8T 2M 86T Red light 8T-C 2M 86T-C Special Polarizing Reflector E9-RP 500 mm [00 mm]* E9-RSP 250 mm [0 mm] * E9-RP7 250 mm [0 mm] * A Reflector is provided with the @@(T)-C. A Reflector is not provided with the Sensor. A Reflector is not provided with the Sensor. The MSR function is enabled. A Reflector is not provided with the Sensor. The MSR function is enabled. Note: Previous OMRON Retroreflective Reflectors (E9-R/-RS/-R2/-R/-R9/-R0/-RK/-RS/-RS2/-RS, etc.) cannot be used with the. *Values in parentheses indicate the minimum required distance between the Sensor and Reflector.

Mounting Brackets A Mounting Bracket is not provided with the Sensor. Order a Mounting Bracket separately if required. [Refer to Dimensions on E9-L/F9-L/E9-S/E9-R, E9-L@.] Appearance Model Quantity Remarks Appearance Model Quantity Remarks E9-L5 (SUS04) E9-L98 (SUS04) Metal Protective Cover Bracket * Mounting Brackets E9-L04 (SUS04) E9-L50 (SUS04) set E9-L4 (SUS04) Horizontal Mounting Bracket * E9-L5 (SUS04) set (Sensor adjuster) Easily mounted to the aluminum frame rails of conveyors and easily adjusted. For vertical angle adjustment E9-L42 (SUS04) Horizontal Protective Cover Bracket * E9-L44 (SUS04) Rear Mounting Bracket E9-L44 (SUS04) Compact Protective Cover Bracket * *Cannot be used for Standard Connector models. Sensor I/O Connectors (Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.) [Refer to Dimensions on XS.] Size Specifications Appearance Cable Model M8 (4 pins) Standard Straight * L-shaped * *2 2 m XSF-E42-402-A 5 m XSF-E42-405-A 4-wire 2 m XSF-E422-402-A 5 m XSF-E422-405-A Note: The outer cover of the cable is made of PVC (polyvinyl chloride), the nut is make of SUS6L stainless steel, and the degree of protection is IP67 (IEC 60529). When high-pressure washing will be used, select an I/O Connector that has IP69K degree of protection. *. The connector will not rotate after connecting. *2. The cable is fixed at an angle of 80 from the sensor emitter/receiver surface. 4

Ratings and Specifications Sensing method Retroreflective with P-opaquing (*) and MSR functions Model NPN output 6(-C)/-B66(-C) 6T(-C)/-B66T(-C) (*2) Item PNP output 8(-C)/-B86(-C) 8T(-C)/-B86T(-C) (*2) Sensing distance 00 to 500 mm (Using E9-RP) Standard sensing object 500-ml, transparent, round PET bottle (65-mm dia.) Directional angle Sensor: to 0 Reflector: 0 Light source (wavelength) Red LED (650 nm) Power supply voltage 0 to 0 VDC, including 0% ripple (p-p) Current consumption 450 mw max. (current consumption for a 0-V power supply voltage: 5 ma max.) Control output power supply voltage: 0 VDC max., current: 00 ma max. (Residual voltage: 2 V max.) Open-collector output (NPN/PNP output depending on model) Operation mode Light ON/Dark ON cable switch selectable Light ON/Dark ON switch selectable Protection circuits Reversed power supply polarity, short-circuit protection, Mutual interference prevention, and Reversed output polarity protection Response time Operate or reset: ms max. Sensitivity adjustment Teaching method One-turn adjuster Ambient illumination Incandescent lamp:,000 lx max., Sunlight: 0,000 lx max. Ambient temperature range Operating: 40 to 60 C (*), Storage: 40 to 70 C (with no icing or condensation) Ambient humidity range Operating: 5% to 85%, Storage: 5% to 95% (with no condensation) Insulation resistance 20 MΩ min. at 500 VDC Dielectric strength,000 VAC, 50/60 Hz for min Vibration resistance Destruction: 0 to 55 Hz,.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s 2 times each in X, Y, and Z directions Degree of protection *4 IEC IP67, DIN 40050-9: IP69K Connection method Pre-wired cable (standard length: 2 m) or M8 4-pin connector Indicators Operation, Stability (green), and Teaching (red) Weight (packed state) Pre-wired models: Approx. 85 g Connector models: Approx. 5 g Housing SUS6L Lens PMMA (polymethylmethacrylate) Materials Indication PES (polyethersulfone) Buttons Fluoro rubber Cable PVC (polyvinyl chloride) Accessories *5 Instruction sheet, Special Reflector (@@-C only) *. For information on the P-opaquing function, refer to pages and 9. *2. If a sensing object such as a glass plate is being used, the light reception level may not be attenuated sufficiently. In the following cases, be sure to test operation sufficiently under actual operating conditions. ) If the temperature varies more than 5 C 2) If the Sensor or Reflector moves due to vibration *. Do not bend the cable in temperatures of 25 C or lower. *4. IP69K Degree of Protection Specification IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9. The test piece is sprayed with water at 80 C at a water pressure of 80 to 00 BAR using a specified nozzle shape at a rate of 4 to 6 liters/min. The distance between the test piece and nozzle is 0 to 5 cm, and water is sprayed horizontally for 0 seconds each at 0, 0, 60, and 90 while rotating the test piece on a horizontal plane. *5. Mounting Brackets must be ordered separately. 5

Engineering Data (Typical) Parallel Operating Range (Horizontal) @/B@6 + E9-RP (Special Reflector) Distance Y (mm) 25 20 5 0 5 0 5 0 5 20 X Y Parallel Operating Range (Vertical) @/B@6 + E9-RP (Special Reflector) Distance X (m) 40 0 20 0 0 0 20 0 X Y 25 0 200 400 600 800 000 200 400 600 Distance X (m) 40 0 200 400 600 800 000 200 400 600 Distance X (m) Excess Gain vs. Distance @/B@6 + E9-RP (Special Reflector) Excess gain ratio (times) 2.5 2.0.5.0 0.5 0.0 0 500 000 500 2000 Distance (m) Note: The AC function controls the excess gain ratio to be a constant multiple of 2. Dark Excess Gain vs. Sensing Object Characteristics Relative amount of light received 2.5 2.0.5 250 mm 500 mm Dark Excess Gain vs. Position Relative amount of light received 2.5 2.0.5 Sensing object: Round, 65-mm-dia., 500-ml PET bottle (empty) Sensing object position A B (intermediate) C L: Distance between Sensor and Reflector Operating level.0 0.5 Gain Operating level.0 0.5 Gain 0.0 No sensing object Empty Filled with water Round, 500-ml PET bottle Empty Filled with water Square, 500-ml PET bottle Empty Filled with water Square, 2-l PET bottle 0.0 No sensing object A A B C A B C L = 00 mm L = 250 mm L = 500 mm 6

I/O Circuit Diagrams NPN Output Model 6 66 6T 66T Operation mode Light ON Dark ON Light ON Dark ON Timing charts Incident light No incident light Operation ON Output transistor ON Operate (e.g., relay) Reset Between brown () and black (4) leads Incident light No incident light Operation ON Output transistor ON Operate (e.g., relay) Reset Between brown () and black (4) leads Light incident Light interrupted ON ON Operate Reset Operation Output transistor (e.g., relay) Light incident Light interrupted ON Operation Output transistor (e.g., relay) ON Operate Reset (Between brown and black leads) (Between brown and black leads) Operation selector switch Connect pink lead (2) to brown lead (). Connect pink lead (2) to blue lead () or leave open. L side (LIGHT ON) D side (DARK ON) Operation (Yellow) Teaching (red) 2 4 Stability (Green) Photoelectric Sensor main circuit M8 Connector Pin Arrangement Operation (Yellow) Stability (Green) Photoelectric Sensor Main Circuit Output circuit Brown 0 to 0 VDC Light ON (Relay) Black 4 ZD Blue Pink 2 Brown (Control 00 ma output) max. 4 Black ZD Blue Dark ON 0 to 0 VDC (Relay) 0 V 00 ma max. (Control output) 0 V PNP Output Model Operation mode Timing charts Operation selector switch Output circuit 8 86 Light ON Dark ON Incident light No incident light Operation ON Output transistor ON Operate (e.g., relay) Reset Incident light No incident light Operation ON Output transistor ON (e.g., relay) Operate Reset Between blue () and black (4) leads Between blue () and black (4) leads Connect pink lead (2) to brown lead (). Connect pink lead (2) to blue lead () or leave open. Operation (Yellow) Teaching (red) 2 4 Stability (Green) Photoelectric Sensor main circuit M8 Connector Pin Arrangement Brown ZD Black 4 Blue Pink 2 Light ON 0 to 0 VDC Dark ON 00 ma max. (Control output) (Relay) 0 V 8T 86T Light ON Dark ON Light incident Light interrupted ON ON Operate Reset Operation Output transistor (e.g., relay) Light incident Light interrupted ON ON Operate Reset Operation Output transistor (e.g., relay) (Between blue and black leads) (Between blue and black leads) L side (LIGHT ON) D side (DARK ON) Operation (Yellow) Stability (Green) Photoelectric Sensor Main Circuit (Control output) Brown ZD Black 4 00 ma max. Blue 0 to 0 VDC (Relay) 0 V Plugs (Sensor I/O Connectors) M8 4-pin Connectors 4 2 2 4 XSF-E42-402-A XSF-E42-405-A XSF-E422-402-A XSF-E422-405-A Wire color Brown White Blue Black Classification Wire color Connector pin No. Application Brown Power supply (+V) DC White 2 Operation selection * Blue Power supply (0 V) Black 4 Output Note: The above M8 Connectors made by OMRON are IP67. Do not use them in an environment where IP69K is required. *Not available on the @@T. 7

Nomenclature Teaching Models One-turn Adjuster Models @ @T Stability (green) Operation Stability (Green) Operation (Yellow) Sensitivity adjuster Teaching (red) TEACH button Operation selector Teaching Method Note: When the Sensor is first unpacked and used, the teaching (red) will flash slowly to show that teaching has not yet been done. This does not indicate a malfunction. Use the following procedure to conduct teaching.. Install the Sensor and Reflector and adjust the optical axis (without placing a Sensing objects between them). Then press and hold the TEACH button for at least 2 seconds. The teaching (red) will start flashing quickly. Perform the following operation within 7 seconds after first starting to press the TEACH button. (After 7 seconds, the Unit will return to its initial condition.) * Flashes quickly The stability (green) and operation will retain their lit or status, and the teaching (red) will flash. 2. Press the TEACH button again. Teaching will then begin. The teaching (red) will remain lit during the teaching operation. Remains lit When Teaching Is Successful The teaching (red) will go out. The Unit will then enter Dark ON setting normal operating condition. Light ON setting When Teaching Is Not Successful The teaching (red) will flash slowly or quickly. Flashes slowly or quickly The teaching (red) will then begin flashing even more slowly, indicating that the teaching operation should begin. Flashes even more slowly Repeat the operation starting with step. Note: Depending on the amount of light received, the operation and stability may also change during the teaching operation. 8

Technical Descriptions New Technology for Detecting Transparent Objects Exhibiting Birefringence P-opaquing (Polarization-opaquing) Conventional photoelectric sensors for detecting PET bottles depend on refraction due to the bottle's shape or on the attenuation of light intensity caused by surface reflection. However, it is difficult to attain a sufficient level of excess gain with these methods. The utilizes the birefringent (double refraction) property of PET bottles to dramatically increase the level of excess gain. The polarization component that is disturbed by the PET bottles as they pass along the line is cut by a special and unique OMRON polarization filter. This greatly lowers the intensity of the light received to provide stable detection with simple sensitivity adjustment. P-opaquing is a word that was coined to refer to the process of applying polarization in order to opaque transparent objects that exhibit the property of birefringence. Conventional sensor 80% 0% Patented Attenuation only from the PET bottle shape, refraction, and transmissivity Special polarization filter Conventional reflector E9-RP The excess gain of the is doubled for both light-on and dark-on applications. The excellent stability of the prevents malfunctions from occurring even if something causes the intensity of light received to fluctuate by ±50%. Relative intensity of light received 00% 50% 25% 0 Incident level while teaching Without PET bottle Polarization component disturbed by birefringence Light ON excess gain = 2x Threshold Minimum interrupted light level With PET bottle Dark ON excess gain = 2x New Technology for Achieving Long-term Stability Patented AC (AC cube: Auto Compensation Control for Contamination) (Not available on the @T) Conventional photoelectric sensors with built-in amplifiers Sensitivity adjustment are not equipped with functions to compensate for changes in the intensity of light received caused by dust and other lens-soiling matter, ambient temperature, and changes that occur in the LED over time. This makes it comparatively difficult to achieve long-term, stable detection of objects that exhibit little change in the intensity of light received, such as transparent objects. Time The AC (AC cube) function provided on the No light-receiving compensation periodically feeds the intensity of light received during light- Conventional sensor ON operation back to the light-emitting circuit, to keep the intensity equal to the value set by teaching. Teaching This allows the to attain long-term, stable detection while helping to cut down on maintenance requirements and Restores Setting setting improve the equipment operating ratio. Note: The AC function cannot be used for dark-on operation. Intensity of light received Intensity of light received 0 s Time Threshold Intensity of light received is compensated every 0 s. 9

Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. CAUTION Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explosion may result. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. When using an XSF Connector, be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0. to 0.4 N m. When using another, commercially available connector, follow the usage and tightening torque instructions provided by the manufacturer. Do not use a load that exceeds the rated load. Low-temperature Environments Do not touch the metal surface with your bare hands when the temperature is low. Touching the surface may result in a cold burn. Oily Environments Do not use the Sensor in oily environments. They may damage parts and reduce the degree of protection. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Cleaning Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Cleaning Do not use highly concentrated cleaning agents. Otherwise, malfunction may result. Also, do not use high-pressure water with a level of pressure that exceeds the stipulated level. Otherwise, the degree of protection may be reduced. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Use caution when operating or performing maintenance on the Sensor. Cable Bending Do not bend the cable in temperatures of 25 C or below. Otherwise, the cable may be damaged. 0

Precautions for Correct Use Do not use the Sensor in any atmosphere or environment that exceeds the ratings. Do not install the Sensor in the following locations. () Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity () Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock Connecting and Mounting () The maximum power supply voltage is 0 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as highvoltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. () Use an extension cable with a minimum thickness of 0. mm 2 and less than 00 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. Also, use M screws. (6) Mount the Sensor either using the bracket (order separately) or on a flat surface. (7) Be sure to turn the power supply before inserting or removing the connector. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Power Supply Reset Time The Sensor will be able to detect objects 00 ms after the power supply is tuned ON. Start using the Sensor 00 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning the Power Supply Output pulses may be generated even when the power supply is. Therefore, it is recommended to first turn the power supply for the load or the load line. Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn, so check the wiring before turning ON the power supply again. The shortcircuit protection circuit will be reset. The load short-circuit protection will operate when the current flow reaches.8 times the rated load current. When using a capacitive load, use an inrush current of.8 times the rated load current or lower. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. When disposing of the Sensor, treat it as industrial waste. Mounting Diagram Use a mounting torque of 0.5 N m max. Resistance to Detergents, Disinfectants, and Chemicals The Sensor will maintain sufficient performance in typical detergents and disinfectants, but performance may suffer in some types of detergents, disinfectants, and chemicals. Refer to the following table prior to use. The EZM has passed detergent and disinfectant resistance testing for the substances listed in the following table. Use this table as a guide when considering detergents and disinfectants. Type Product name Mounting Bracket (order separately) E9-L04 Concentration Temperature Time Sodium hydroxide, NaOH.5% 70 C 240 h Potassium hydroxide, KOH.5% 70 C 240 h Chemicals Phosphoric acid, HPO4 2.5% 70 C 240 h Sodium hypochlorite, NaClO 0.% 25 C 240 h Hydrogen peroxide, H2O2 6.5% 25 C 240 h Alkaline foaming cleansers Topax 66s (Ecolab).0% 70 C 240 h Acidic foaming cleansers Topax 56 (Ecolab) 5.0% 70 C 240 h Disinfectants Oxonia Active 90 (Ecolab).0% 25 C 240 h TEK2 (ABC Compounding).% 25 C 240 h Note: The Sensor was immersed in the above chemicals, detergents, and disinfectants for 240 h at the temperatures given, and then passed an insulation resistance test at 00 MΩ min.

Dimensions (Unit: mm) Tolerance class IT6 applies to dimensions in this datasheet unless otherwise specified. Sensors Retro-reflective Models Pre-wired Models 6 8 Operation Indicator 7.8 7.5 Teaching button Stability (green) Teaching (red) 0.8.2 2.8 2 2.7 25.4 Lens 6 dia. Two, M 4 dia. vinyl-insulated round cable with 4 conductors (Conductor cross section:0.2 mm 2 (AWG24), Insulator diameter:. mm), Standard length: 2 m Retro-reflective Models M8 Connector 66 86 7.8 7.5 Operation Indicator Teaching button Stability (green) Teaching (red) 2 4.2 0.8 2.8 2 Lens 6 dia. 25.4 2.7 Terminal No. Specifications +V 2 Operation selection 0 V 4 Output 7 Two, M M8 2

Retro-reflective Models Pre-wired Models 6T(-C) 8T(-C) Operation Indicator Stability (green).6 4.5 Sensitivity adjuster Operation selector 0.8.2 2.8 2 2.7 25.4 Lens 6 dia. Two, M 4 dia. vinyl-insulated round cable with conductors (Conductor cross section:0.2 mm 2 (AWG24), Insulator diameter:. mm), Standard length: 2 m Retro-reflective Models M8 Connector 66T(-C) 86T(-C) Operation Indicator.6 4.5 Sensitivity adjuster Stability (green) Operation selector.2 0.8 2.8 2 7 Lens 6 dia. 25.4 Two, M M8 2.7 Terminal No. Specifications +V 2 --- 0 V 4 Output

Accessory Special Retroreflective Reflector E9-RP 44 8.5 0.2 80 72 6.6 Reflective surface Two,.5 dia. Material: <Reflective surface> acrylic <Rear surface> ABS Special Retroreflective Reflector E9-RP7 Mounting bracket Reflector.7 8.7.7 (.) Reflective surface: acrylic 2 8. 0.2 8. 2 Two, R.55 Two,. dia. Mounting Bracket: t 0.5 Reflector: t 0.5 (adhesive tape side) Material: <Reflective surface> acrylic <Mounting plate> stainless steel (SUS0) Note: The reflective plate and mounting plate () come as a set. Special Retroreflective Reflector E9-RSP Acryl 2 50 0.9 4

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 20.8 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 20 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: 6-C 2M 8-C 2M