DISPOSER CONTROL CENTER

Similar documents
DISPOSER CONTROL CENTER

DISPOSER CONTROL CENTER

DISPOSER CONTROL CENTER

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

FOODSERVICE DISPOSER Installation Manual

Installation Instructions

FOOD WASTE DISPOSERS MODELS FD4-150 FD4-200 FD FORM (May 2015) S. RIDGE AVENUE TROY, OHIO

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

TS0 Series Portable Bulb and Capillary

FOOD WASTE DISPOSER Owner s Manual & Installation Instructions

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

TB4000 Temperature Controller

1/2 1-1/4 H.P. DISPOSER MODELS

The Da-Lite Difference.

FOOD WASTE DISPOSERS

(HSTAT Series) Instruction Manual

Water Boilers ME10EN, ME15EN. Table of Contents

Installation Manual.

Instant Hot Water Dispenser Owner s Manual

Food Waste Disposer Instruction Manual

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Instruction Manual Item No.: V~, 60Hz

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Quest Power Electric Heat EHS 31 Pro

Instruction Manual Item No.: V~, 60Hz

CHILLER. Model CH3000. Operator s & Installation Manual

HotPoly Tote Tank / IBC Heaters (TTH Series)

Garb-el Free Standing Models

Quest Power Electric Heat EHS 62 Pro

FOOD WASTE DISPOSER OWNER S GUIDE

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ion Genesis Pump Controller

B.I.C.A Built-In Coffee Appliance

Read All Instructions Thoroughly Before Installing or Using the Disposer.

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Hot-1 Hot Water Dispenser

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

HIGH TORQUE GARBAGE DISPOSER

Owner s Manual Phoenix FireBird

Panel Fan Series Operators Manual (Galvanized and Polymer)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

The POWER. In PRESENTATION PRODUCTS. Instruction Book For Professional Electrol DA-LITE SCREEN COMPANY, INC.

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTRUCTION MANUAL with Replacement Parts

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

HIGH TORQUE GARBAGE DISPOSER

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

LC Series - Light Commercial Pump Station Installation and Operation Manual

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTANT-FLOW C-MICRO WATER HEATER

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Table of Contents

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Operator s Manual. 68 Inch Conveyor Pizza Ovens

INSTRUCTION BOOK FOR. Professional Electrol

Steamer Display Cabinet Model SDC-500 NIT A T D CM I S T E D. P/N Rev. D 03/12. Owner s Manual

ph COOLING TOWER CONTROLLER

Installation Instructions

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Instruction Book for HD Punch Machines

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Owner s Manual PS-50. Document Number: Revision: Draft

120 VAC SYSTEM CONTROL KIT Model: CK-63

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

USER S OPERATING AND INSTRUCTION MANUAL

Installation & Maintenance Instructions

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

V80-H Multistage Pump Instruction Manual

UNDERCOUNTER DISHWASHER

Greenleaf 600 Macerator Toilet Waste Pump

How your hot water dispenser works

Installation Instructions

INSTANT HOT WATER DISPENSER

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Wrap-Around Tote Tank / IBC Heaters

Installation & Operating Guide

Food Waste Disposer Instruction Manual

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

SX SERIES (Class I, Division 1, Group D) INSTALLATION AND SERVICE MANUAL

CHILLER MODEL: CH1500, 2000 AND 3000

P200E Shuttle Brewer

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

Operating Instructions. For. Alarm Control Module. Model SSR 500

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

INSTRUCTION BOOK FOR. Senior Electrol

Transcription:

DISPOSER CONTROL CENTER Installation Manual Model MS The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which, if not avoided, could result in severe personal injury or death. The Caution signal alerts you to hazards of unsafe practices which, if not avoided, may result in minor personal injury or property damage. Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual. www.insinkerator.com/foodservice Part No. 170 - Rev A

Table of Contents Introduction/Features Introduction... Features... Mounting the Control Center... Plumbing Connections... Electrical Connections Electrical Connections... 5 Time Delay Relay... 5 Operating Instructions/Troubleshooting Operating Instructions... Troubleshooting... Wiring Diagrams Model No. MS- (10V, 1 phase, 1/- HP)... 7 Model No. MS-5 (08-0V, 1 phase, 1/- HP)... 8 Model No. MS-5 (08-0V, phase, 1/-5 HP)... 9 Model No. MS- (80/0V, phase, 1/-10 HP)... 10 Warranty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for one year from the date of installation. The warranty includes parts and labor, provided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage. InSinkErator Foodservice disposer accessories are included in this warranty only if they are included in the original disposer purchase package.

Features/Mounting the Control Center INTRODUCTION The MS Control Center is UL and CUL approved for use with InSinkErator Foodservice Disposers. See Table 1 for approved disposer and control center combinations. The control center operates the disposer. Its main functions are: To start and stop the disposer. To start the water flow to the disposer. Model Waste Disposer Model MS- SS50-, SS75-7, SS100-8, SS15-5, MS-5 SS150-, SS150-8, SS00-7, SS00-1 MS-5 SS50-7, SS75-8, SS100-9, SS15-, SS150-, SS150-9, SS00-9, SS00-, SS00-5, SS00-7, SS500-8, SS500-9, SS500-0 MS- SS50-7, SS75-8, SS100-9, SS15-, SS150-, SS150-9, SS00-9, SS00-, SS00-5, SS00-7, SS500-8, SS500-0, SS750-1, SS750-15, SS1000-10, SS1000-, SS1000-1 Table 1. Approved Disposer and Control Center Combinations Model Part No. Voltage Phase HP MS- 15 10V 1 1/- MS-5 15A 08-0V 1 1/- MS-5 15A 08-0V 1/-5 MS- 15B 80/0V 1/-10 Table. Electrical Specifications FEATURES ENCLOSURE NEMA construction. PUSH BUTTON OPERATION Push Green button to start disposer. Push Red button to stop disposer. MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical position. See Figure 1. Locate control center within sight of disposer per local codes. Locate any remote control station within sight of disposer per local codes. If box is mounted to the sink table, recess the box so that the buttons do not extend beyond the table's edge. Figure 1. Control Center Dimensions Use of more than two solenoid valves will affect the overall function of the MS control center. Extra solenoid valves will cause a reduction in voltage and solenoid actuation will not occur.

Plumbing Connections Figure. Typical Installation Diagram PLUMBING CONNECTIONS The flow control valve, syphon breaker and solenoid valve are supplied with all complete disposer packages (packed separately). Make certain that the solenoid valve supplied is the proper voltage. Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly. The flow control valve regulates all water flowing into the disposer. This conserves water and prevents overloading. Check direction of water flow arrows. Syphon breaker must be installed above the sink flood place per local plumbing codes. Check direction of water flow arrows.

Electrical Connections ELECTRIC SHOCK Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. All installation work must conform to local plumbing and electrical codes. All control centers and disposers must be carefully and permanently grounded. A properly fused disconnect must be installed at the electrical supply source for the control center. Ensure that control center voltage and phase match the disposer motor and electrical supply. Check name plates on disposer and control centers for voltage and phase specifications. Refer to the control center wiring diagrams in this manual for correct connection. Use NEMA watertight electrical connectors (not supplied) when making electrical connections to the control center. ELECTRICAL CONNECTIONS Connect the incoming line power and disposer motor to the labeled terminal block in the control center. Use appropriate voltage and phase electrical connection diagrams at the back of this manual. Wire the disposer motor for the correct voltage using the connection diagram inside the motor terminal box. Make sure the solenoid valve is the same voltage as the control panel and supply power. Connect water solenoid valve as shown in the wiring diagrams on pages 7, 8, 9, and 10. Wire per local electrical code using 7/8" diameter holes in bottom of control center cabinet and install NEMA watertight electrical connectors (not supplied). After completing the connections, secure cover. Replace disposer motor cover. 1 Time Adjustment Knob Figure. 10V or 08/0V Time Delay Relay TIME DELAY RELAY (Optional, not supplied with MS) The time delay relay may be used with the MS to delay solenoid valve shut-off, providing a post flush. This helps prevents drain line stoppages and is beneficial when ground food waste must travel through many bends or a long horizontal run. It is adjustable from 0 to 10 minutes and factory set to provide approximately a 5 minute delay. To adjust, SHUT OFF ELECTRIC POWER. Inside unit, locate the adjustment potentiometer. Turn clockwise to increase delay. Turn counterclockwise to decrease delay. See Figures and 5 for wiring. Ensure the voltage rating on the time delay relay and solenoid valve are the same as the disposer motor and line voltage. Figure. Time Delay Relay Connections - 10V or 08/0 V Figure 5. Time Delay Relay Connection - 0V, -phase only 5

Operating Instructions/Troubleshooting PERSONAL INJURY Allow only trained personnel to operate disposer. Use baffles and guarding to avoid splashing and ejection of materials. Do not put fingers or hands into the disposer. When attempting to remove objects from a disposer, use long-handled tongs or pliers. Turn power off before clearing a jam, removing an object from the disposer or pressing the red reset button. OPERATING INSTRUCTIONS TO START 1. Check to ensure disposer is free of foreign objects.. Ensure power is on.. Push start button. Disposer motor will run and water will flow into the disposer. TO STOP 1. Push stop button. Disposer motor and water will stop. ELECTRICAL SHOCK/ Troubleshooting other than what is recommended in this section should only be performed by qualified service personnel. Further troubleshooting performed by untrained personnel could result in electric shock or damage to the control center. All electrical checks must be performed by a qualified professional. TROUBLESHOOTING This control center was inspected and tested under operating conditions before shipment from the factory. In case of trouble, check the items listed below. A. Disposer motor will not start and water does not flow. 1. No incoming line power, turn line power on. B. Disposer motor stops while grinding but water continues to flow. 1. Disposer is jammed. Press the stop button and follow directions for unjamming that were supplied with the disposer.. Disposer motor overload protector has tripped. Follow instruction in C1. C. Disposer will not start but water flows. 1. Overload protector on the disposer may have tripped. Press stop button. Locate red reset button on front of disposer electrical cover. Press to reset. If motor had been running, wait five minutes for the motor and overload to cool down before starting.. Disposer is jammed. Press the stop button and follow directions for unjamming that were supplied with the disposer. D. Water flows constantly before start button is pushed. 1. Water solenoid valve is installed backward. Water flow should be in the direction of the arrow on valve.. Water solenoid valve is wired incorrectly. Recheck wiring diagram. E. Overload trips frequently. 1. Do not overload disposer with excess amounts of garbage and water. (See disposer instructions for recommended water flows.) If trouble still persists, call your nearest InSinkErator Authorized Service Agency. For the location of your nearest service agency, call toll-free 1-800-85-85.

MS- Wiring Diagram P/N 15 ELECTRICAL SHOCK Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. Installation must conform to local electrical codes. All control centers and disposers must be carefully and permanently grounded. A properly fused disconnect must be installed at the electrical supply source for the control center. Ensure that the control center voltage and phase match the disposer motor and electrical supply. Check nameplates on disposers and control centers for voltage and phase specification. The disposer motor wiring connection is shown in the disposer terminal box. 10 V 1-phase 1/ to HP A1 A 1L1 L 5L 1NO T1 T T 1NO A WATER SOLENOID VALVE L1 L L 1 7-1 - - - L1 L INCOMING POWER SUPPLY TO PANEL GROUND DISPOSER MOTOR 5 Call Toll Free 1-800-85-85 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. 7

MS-5 Wiring Diagram P/N 15A ELECTRICAL SHOCK Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. Installation must conform to local electrical codes. All control centers and disposers must be carefully and permanently grounded. A properly fused disconnect must be installed at the electrical supply source for the control center. Ensure that the control center voltage and phase match the disposer motor and electrical supply. Check nameplates on disposers and control centers for voltage and phase specification. The disposer motor wiring connection is shown in the disposer terminal box. 08-0 V 1-phase 1/ to HP A1 A 1L1 L 5L 1NO T1 T T 1NO A WATER SOLENOID VALVE L1 L L 1 7-1 - - - L1 L INCOMING POWER SUPPLY TO PANEL GROUND DISPOSER MOTOR 5 Call Toll Free 1-800-85-85 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. 8

MS-5 Wiring Diagram P/N 15A ELECTRICAL SHOCK Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. Installation must conform to local electrical codes. All control centers and disposers must be carefully and permanently grounded. A properly fused disconnect must be installed at the electrical supply source for the control center. Ensure that the control center voltage and phase match the disposer motor and electrical supply. Check nameplates on disposers and control centers for voltage and phase specification. The disposer motor wiring connection is shown in the disposer terminal box. 08-0 V -phase 1/ to 5 HP A1 A 1L1 L 5L 1NO T1 T T 1NO A WATER SOLENOID VALVE L1 L L -1 - - - 9 8 1 7 L1 L L INCOMING POWER SUPPLY TO PANEL GROUND 10 DISPOSER MOTOR 5 1 Call Toll Free 1-800-85-85 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. 9

MS- Wiring Diagram P/N 15B ELECTRICAL SHOCK Turn off the electrical supply to the disposer before attempting any work on it. Use a voltmeter or circuit tester to ensure that power is off. Installation must conform to local electrical codes. All control centers and disposers must be carefully and permanently grounded. A properly fused disconnect must be installed at the electrical supply source for the control center. Ensure that the control center voltage and phase match the disposer motor and electrical supply. Check nameplates on disposers and control centers for voltage and phase specification. The disposer motor wiring connection is shown in the disposer terminal box. 80/0 V -phase 1/ to 10 HP A1 A 1L1 L 5L 1NO T1 T T 1NO -1 - A WATER SOLENOID VALVE L1 L L - - 1 10 1 L1 L L INCOMING POWER SUPPLY TO PANEL GROUND 7 DISPOSER MOTOR 8 5 9 Call Toll Free 1-800-85-85 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support. 10