Report VNLF Test Report

Similar documents
Report VNNF Test Report

~~oeti. Report VN71 O Classification Report. Reference

~,oeti. Report VN Classification Report. Reference

Report Test Report

Report Classification Report on Burning Behaviour

Analysis Report

Analysis Report

TFI Report Reaction to fire test

BCTC CARPET TECHNICAL CENTRE

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

BS EN ISO : 2010

TFI Report Classification

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Test Report: ICL/CR15/11/087

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Shipboard incinerators with capacities up to 4000 kw

Review Fire Test Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Coatings for protection of FRP structures with heavy rain erosion loads

IMO Resolution MSC 61(67): Annex 1: Part 2

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Test Report: ICL/H18/9039 Rev 1

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Test Report No

ISO INTERNATIONAL STANDARD

Test Report No: ICL/H17/7967

Form: KSD-100:10 Page 1 of 3

Centrum stavebního inženýrství a.s.

TFI Report Classification

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

Classification of Fire Performance of Wall and Ceiling Lining Materials

3th International Conference in Warsaw "MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK"

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

BS EN : 2001 & IEC :2000

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Glass fibre rovings - Non-metallic materials

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

ISO INTERNATIONAL STANDARD

Üntel is ready for CPR

Conformity assessment procedures for the Alarm Components Scheme

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

FUNDERMAX GMBH FIRE TEST REPORT


Contact person Date Reference Page Richard Johansson P (2) Fire Research

FAÇADE FIRE TESTS Towards a new European standard method

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Development of a European approach to assess the fire performance of facades

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CE TYPE EXAMINATION CERTIFICATE

TEMPORARY IMMERSION AND DUST TEST REPORT

Loss Prevention Standard

Test Report. Appliance EMF Testing

Reaction to fire classification report No C-rev.1

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

ISO INTERNATIONAL STANDARD

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

FIRST-CLASS IN TRAINS

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur

CE TYPE EXAMINATION CERTIFICATE

CLASSIFICATION REPORT

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

Transcription:

Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according to EN ISO 9239-1 and the ignition according to EN ISO 11925-1. Test material Kable-Mat" Material used in testing was anonymized for laboratory purposes. A detailed sample list is contained in the report. Issuing and Signatures Number of pages contained: 8 Original Issue / Vienna 25.08.2015 / mm /1124 Translation Authorised for Institute Ing. Hannes Vittek ÖTI- Institut für Ökologie, Technik und Innovation GmbH Spengergasse 20,1050 Vienna, Austria tel +43 1 5442543-0 I fax +43 1 5442543-10 email office ßoeti.at FN 326826b [ VAT No. ATU65149029 UniCredit Bank Austria AG IBAN AT941200023410378800 BIC BKAUATWW j EORI ATEOS1000015903 Es gelten ausschließlich unsere Allgemeinen Geschäftsbedingungen Onlyourgeneral terms and conditions apply

VNLF 081158.1 2 / 7 Contents 1 Order... 2 1.1 Chronology... 2 1.2 Samples... 2 2 Findings / Tests performed... 3 2.1 Description of building product... 3 2.2 Determination of the burning behaviour of floor coverings using a radiant heat source... 3 2.3 Diagrams of integrated smoke obscuration... 5 2.4 Appearance of specimens test... 6 2.5 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame... 6 3 Remarks... 7 1 Order 1.1 Chronology Date Received Order 29.07.2015 29.07.2015 Determination of the burning behaviour according to EN ISO 9239-1 and the ignition according to EN ISO 11925-1. 1.2 Samples Nr. Received Sample Identification 1 29.07.2015 Kable-Mat (Unless otherwise stated samples are provided by the customer.)

VNLF 081158.1 3 / 7 2 Findings / Tests performed 2.1 Description of building product Test results Tested sample: 1 Manufacturing procedure: Material of pile/wear layer: Primary backing: Structure of use surface: Colouring: Secondary backing: Dimensions: tufted 100 % Polyamide (according to the specification by the applicant) fleece loop pile plain (single coloured) Nitrile rubber Mats specification by ÖTI specification by the applicant Total mass 3993 g/m² 3950 g/m² Total thickness 8,0 mm 13,0 mm 2.2 Determination of the burning behaviour of floor coverings using a radiant heat source Test conditions According to: EN ISO 9239-1 (a) Conditioning: according EN 13238 (4.3) Substrate: Fibre cement boards according EN 13238 (5.1.2) Arrangement of specimens: loose laid on substrate Statement The test results relate to the behaviour of the test specimens of the products under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the products in use. Test results Tested sample: 1 Specimen (direction) Flame spread [cm] 10 min 20 min 30 min Self extinguishing Self extinguishing [min : sec] 1 (length) 33 44 48 -- -- 2 (cross) 25 39 42 -- -- 3 (length) 25 42 46 -- -- 4 (length) 27 44 48 -- --

VNLF 081158.1 4 / 7 Specimen (direction) 10 min Radiant flux [kw/m²] 20min 30 min at Self extinguishing Maxi. light attenuation Integral of smoke obscuration [HF-10] [HF-20] [HF-30] [CHF] [%] [%.min] 1 (length) 6,5 4,4 3,9 -- 85,7 728 2 (cross) 8,1 5,4 4,6 -- 77,8 634 3 (length) 8,1 4,6 4,3 -- 71,8 712 4 (length) 7,7 4,4 3,9 -- 79,8 708 Mean value of critical radiant flux 1) Mean value of integral of smoke obscuration 2) 4,0 kw/m² 716 %.min Remarks: 1) The mean value of the critical radiant flux is calculated from the results of HF-30 or CHF of the three specimens with the same direction. If both values are stated, the lowest one is taken for calculation. 2) The mean value of the integral of smoke obscuration is calculated from the results of the three specimens with the same direction. Measuring point [mm] Time [min : sec] at which the flames are reaching the measuring points Specimen 1 (length) Specimen 2 (cross) Specimen 3 (length) Specimen 4 (length) 50 4 : 00 5 : 10 4 : 20 4 : 10 100 5 : 40 6 : 40 6 : 20 6 : 00 150 6 : 40 7 : 50 7 : 30 7 : 10 200 7 : 20 8 : 30 8 : 10 8 : 10 250 8 : 20 9 : 50 9 : 40 9 : 00 300 9 : 30 12 : 00 11 : 10 10 : 50 350 11 : 00 13 : 40 13 : 10 13 : 10 400 13 : 30 20 : 10 17 : 00 16 : 00 450 22 : 40 -- 27 : 10 22 : 40 Observations during the test: Melting of the wear layer

VNLF 081158.1 5 / 7 2.3 Diagrams of integrated smoke obscuration Specimen 1 (length) Specimen 2 (cross) Specimen 3 (length) Specimen 4 (length)

VNLF 081158.1 6 / 7 2.4 Appearance of specimens test This photo shows the specimens 1 to 4 (from left to right side). One section of the rule is equivalent to 5 cm. 2.5 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Test conditions According to EN ISO 11925-2 (a) Conditioning: according EN 13238 (4.2) Substrate: Fibre cement boards according EN 13238 (5.1.2) Arrangement of the samples: loose laid Number of specimen: 3 in length, 3 in cross direction (250 mm x 90 mm) Exposure conditions: Surface exposure Flame application time: 15 s Statement The test results relate to the behaviour of the test specimens of the products under the particular conditions of the test; they are not intended to be the sole criterion for assessing the potential fire hazard of the products in use. Test results Tested sample: 1 Length direction Cross direction Specimen 1 2 3 1 2 3 Ignition no no no no no no Flaming debris no no no no no no Ignition of filter paper no no no no no no Reaching the measuring mark (150 mm) no no no no no no Time to reach the measuring mark -- -- -- -- -- -- Special observations during the test: none

VNLF 081158.1 7 / 7 3 Remarks Validity There are no regulations concerning duration of validity in the individual test standards. As the results of the examinations refer only to the submitted and examined samples, the report is valid for these for an unlimited period. A period of validity specified as part of an expert evaluation is in the discretion of the consultant or the ÖTI. The applicability of results and expert evaluations for materials not tested is in the responsibility of the applicant. Whereby an apportionment of results as well as any specified period of validity can only be done for identically constructed products and only as long as the product produced unchanged. Possible national or international restrictions concerning the terms of usability of test and classification reports have to be considered; this is not the responsibility of the test laboratory. Sample Material Results of performed tests only refer to the sample material provided. Without explicit written other agreement testing is destructive and the sample material is transferred to the property of ÖTI, which is entitled to freely decide on storage and disposal. Issuance The valid first issue is done in paper and has single-handed signatures. For reference purposes and filing an unsigned electronic duplicate can be delivered in pdf format. Duplicates and translations will be marked accordingly on the cover sheet. Quality management, Accreditation and Notification All tests and services are performed under a quality management system according to EN ISO/IEC 17025 respectively EN ISO/IEC 17065. The ÖTI is accredited as Testing Laboratory and Certification Body for products. It also is a Notified Body for several directives with the registration number 0534 (see http://ec.europa.eu/enterprise/newapproach/nando/). Accreditation as Testing Laboratory was provided by Akkreditierung Austria (bmwfw). The scope of accreditation is listed on www.bmwfw.gv.at/akkreditierung. In this report test conditions of individual accredited test procedures are marked with ( a ). According to the decree on the use of the accreditation mark ( AkkZV ) the accreditation mark is only to be used by the accredited Conformity Assessment Body. Application of the registration number of the Notified Body: As to personal protective equipment (PPE) the requirements of PSA-SV 10, BGBl. Nr. 596/1994 as amended and article 13 of the Directive 89/686/EEC have to be kept. With construction products the application is only permitted within the declaration of performance for CE-marking. Copyright and Usage Notes It is pointed out, that any alterations, amendments or falsifications of reports not authorized by the issuer of the report will be prosecuted as civil and criminal offences; this especially to the appropriate requirements of ABGB, UrhG, UWG and criminal law and their respective international equivalents. Reports are protected under international copyright laws. Written consent of the ÖTI is required for publications (also in excerpt) and reference to tests for public relation purposes. Reports may only be reproduced in full length. End of report