PROVIDING GROWTH TO RESEARCH.

Similar documents
TCC-34. Features: TISSUE CULTURE

SPC-56 SHORT PLANT.

TCR. Features: TISSUE CULTURE

TPR. Features: TALL PLANT

SPC-7-2H SHORT PLANT.

RIGID DC LIQUID CHILLER

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Refrigeration System with a Capillary Tube and a Thermostat

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

The Design Flaw in HVAC

17 Interior Climate Control

DAVE DEMMA ACHIEVING HEAD PRESSURE CONTROL

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

2.2. General view of Microchannel Heat Exchangers

Refrigeration Basics from a Brewery Perspective

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

Air-Cooling Evaporators

Fundamentals of Refrigeration Part 2 Refrigeration 1

EkoAir Heat exchanger selection manual.

Refrigerants Type Expensive Coefficient of Performance Toxic

CIRRUS AIRPLANE MAINTENANCE MANUAL

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Reach-In. PLanT GROWTh. Reach-In

Fundamental Principles of Air Conditioners for Information Technology

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

Thermohygrometer with Single Type K Input and Superheat Function

Heat Pump Water Heaters

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

A Chiller is equipment to control temperature of customers heating sources. Application Examples

FITOCLIMA 600 & 1200 STABILITY

Selection of air conditioning systems

Presentation on HVAC: Heating Ventilation Air Conditioning

Engineered for flexibility and performance

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

Study Final Report. Priority Cool Refrigerant Study

Innovative heating systems in historical buildings Vilnius

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

RPI Industries, Inc.

Savings Without Sacrifice

Automotive Air Conditioning systems

FITOCLIMA 600 & 1200 STABILITY

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

FITOCLIMA 600 & 1200 PHARMA

Home WHOLE-HOME COMFORT SOLUTIONS. Bringing balance. Creating comfort.

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Introduction. Motor Types

Environmental Chamber Webinar Series. Benefits of "Part Temperature Control" May 2017

Workshop on AFDD for RTUs Moving from R&D to Commercialization July 13, Introduction

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

TECH. BULLETIN ISSUE TWENTY

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

European Researcher, 2014, Vol.(75), 5-2

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

TOYOTA FJ-40 DIRECTIONS

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Metal hydride storage system for MICE experiment at Rutherford Appleton Laboratory. Technical specification.

Title: Heat Recovery From Milk Cooling Systems

How about Savings in Time, Money, Energy and Longer Life?

Hydronic Comfort Systems Increase and Maintain Building Efficiency

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Appendix 13. Categories of Cooling and Heating systems

Innovent s. Direct Replacement Program. Engineered to match... your footprint, your needs.

Liquid Cooling for HPAs

1.1. SCOPE OF THE WORK:

DOCUMENT TABLE OF CONTENTS

A/C-HEATER SYSTEM - MANUAL

Nordic Heat Pump Product Guide

Model DH-10 Dehumidifier

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Spray Dryer Standard Operating Procedure

HPLC Column Ovens and Temperature Controllers

INFRARED HVAC APPLICATION HVAC 101

HVAC Basics RESIDENTIAL AIR CONDITIONING

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

What you need to know

VWR symphony CO 2 INCUBATORS

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

The Refrigeration Cycle (Air Conditioners)

Environmental Systems

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

Using Portable Spot Air Conditioners in Industrial Applications

SMT Quick-Tips: selecting a reflow oven. Robert Voigt, DDM Novastar

Refrigerator and Air conditioner Testing in the Republic of Korea

Transcription:

www.biochambers.com PROVIDING GROWTH TO RESEARCH. Condensers Guidelines on Choosing the Correct Type for Your Application.

Introduction Plant growth chambers provide researchers with a tremendous amount of control of environmental parameters, including temperature, humidity, CO 2 levels, and more. To maintain their set temperature, most plant growth chambers have a dedicated refrigeration system to remove heat from the chamber and accurately maintain the required temperature. Heat inside the chamber is generated from various sources including the lamps, circulating fans, fresh air, and more. Heat is removed from the chamber by circulating the air inside the chamber over a heat transfer coil, commonly called an evaporator. As air passes over the evaporator the heat is transferred from the air into a fluid that passes through the tubes of the evaporator. This fluid (or refrigerant, sometimes called Freon ) then carries the heat from the evaporator to a location outside the chamber. Once the refrigerant has made its way outside the chamber the heat must be removed before it can continue back to evaporator to absorb more heat from the chamber. The component responsible for cooling the refrigerant outside the chamber is called the condenser. There are several types of condensers available and choosing the correct type for your application is an important factor when purchasing and installing a plant growth chamber. This depends on the amount of space available in the facility and the utilities available in the area of the chamber installation. For perspective, the size of an air conditioning unit required for a standard plant growth chamber is comparable to the size of an A/C unit required for a 1500 ft² house. Remote Air-Cooled Condenser (RACC)

Water-Cooled Condensers Water-cooled condensers are the most common choice where a source of cooling water is readily available. If available this is also the simplest solution since the infrastructure is already in place and connection to the chamber is usually a fairly straight forward and inexpensive process. It is important to verify that the cooling water is available in the location you wish to place your plant growth chamber, and that the cooling water system can handle the extra heat from the chamber. Benefits Condenser is small and compact and can usually be located within the plant growth chamber itself, reducing the overall space required in the lab. Condenser is less expensive compared to air-cooled options. Drawbacks A cooling water supply with adequate capacity must be available, either currently installed or planned in building renovations, prior to equipment commissioning. Figure 1 - Water-cooled chamber The plant growth chamber is dependent on a separate system for operation. If the cooling water supply fails, the chamber will shut down.

Self-Contained Air-Cooled Condensers (SCACC) If cooling water is not available in the facility, the refrigerant in the chamber system is usually cooled by air. This type of condenser looks much like a car radiator, with fans to move air over the coil. For larger plant growth chambers this type of condenser is located outdoors because of its size and the amount of heat released from the condenser. However, for small chambers this condenser can be located on the plant growth chamber itself. This makes installation of the plant growth chamber simple as no additional piping or electrical wiring is required for the condenser. However, in this case the heat from the plant growth chamber is released to the air in the laboratory and must be removed by the building HVAC system. Benefits No cooling water supply is needed. No additional plumbing is needed, resulting in easy installation. Condenser is small and compact (usually located on the plant growth chamber itself) reducing the chamber footprint and simplifying installation. Drawbacks Option is limited to small plant growth chambers. Heat from the chamber must be removed from the laboratory. Small amount of additional noise from the condenser fan. Figure 2 - Self-contained air-cooled chamber

Remote Air-Cooled Condensers (RACC) For larger plant growth chambers which do not have access to cooling water and for which self-contained aircooled condensers become too large for indoor installation and release too much heat for building HVAC systems, larger outdoor condensers must be used. A suitable location near to the plant growth chamber must be available. Often this is at ground level or on the building roof. The condenser must have a suitable footing to ensure stability, such as a solid concrete base, and adequate space around the unit to accommodate required airflow. Refrigeration pipes must be run to join the condenser to the chamber. The condenser must also be supplied power, either directly from the plant growth chamber or from a separate power source nearby. Benefits No cooling water supply is needed. Drawbacks Condenser must have a suitable location available for installation. Additional refrigeration and electrical work must be done to connect the condenser to the plant growth chamber and provide it with power. Figure 3 - Remote air-cooled chamber

Remote Air-Cooled Condensing Unit (RACCU) In some laboratories it is critical to keep the sound level as low as possible. There is one more condenser option which takes the two loudest components on the chamber, the condenser fan(s) and the compressor, and locates them both outdoors. The resulting piece of equipment placed outdoors is called an air-cooled condensing unit. This condensing unit combines a remote air-cooled condenser (RACC) with an enclosed compartment to house the compressor and controls. Installation is very similar to the RACC option, but some additional piping and control cabling are required. Benefits Noise from the chamber is reduced. No cooling water supply is needed. Drawbacks Condensing unit must have a suitable location available for installation. Additional refrigeration and electrical work must be done to connect the condenser to the plant growth chamber and provide it with power. Figure 3 - Remote air-cooled chamber

PROVIDING GROWTH TO RESEARCH. 477 Jarvis Avenue Winnipeg, Manitoba, Canada R2W 3A8 Tel: (204) 589-8900 Fax: (204) 582-1024 Toll Free: 1-800-361-7778 Email: info@biochambers.com Biochambers Condensers Document version 2017-07A. Our policy of continuous product improvement will occasionally result in changes to product specifications without notice. BIOCHAMBERS INCORPORATED 2017. ALL RIGHTS RESERVED PRINTED IN CANADA www.biochambers.com