DECO louvre vertical. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

Similar documents
panel plus horizontal wall-mounted

A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

DECO louvre horizontal. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

ARISTOCRAT. Elite towel rail for every situation

arco plus Distinctively elegant vertical radiators

IGUANA visio. Radiators that mirror your style

High output, high art. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

IGUANA circo wall-mounted. Distinctively elegant vertical radiators

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

circo PLUS wall-mounted

Play DBE. Colourful, fun, safe. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

BRISE. Heating and cooling from a single radiator

Basic DBE. Easy installation in less than two hours

FREEDOM 2019.EX CZ - 21/11/18

QUATRO CANAL 2019.EX

CLIMA CANAL Lyngson as

VeRtiga the new benchmark for design at super-low water temperatures

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Units for suspended ceilings

MINI CANAL DBE 2015.UK

Zehnder Electric radiators for living rooms

Passive chilled beams

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

BRIZA Super slim and powerful heating, cooling

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

new DRAFT This is not the final version of this document! But prices and outputs should be good. play Playful warmth, colourful comfort

IMI Heimeier Kit Hydroca ble

Quatro canal Super-powered climate control for 4-pipe systems

IRONING BOARD CATALOG FOR HOME

BRISE. Super-power for heating, cooling and ventilation.

CLIMA CANAL. Complete climate control and high power

Units for suspended cei lings

VOGEL&NOOT. Convectors & heating panels. heatingthroughinnovation.

Type CODE Speed Heating Cooling

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

WHE 2.24 / WHE 2.24 FF

PLAN KLASIK LINE KLASIK

Mikrotherm. Manual Radiator Valves With presetting

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

BOOST INTO THE FUTURE

Metering systems 0548EN April 2014

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

INSTRUCTIONS AND WARRANTY

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

Brochure EX

CLIMA CANAL Complete climate control and high power

made in Italy Extruded Radiators with Anticorrosion Treatment

Towel Warmers Electric Rad catalogue

Ceramic soleplate steam iron. Help line: Model: SI30110BLKN v1.0

EuroPlan/EuroProfil Panel radiators

Thermostatic valves with radiator connection systems

Multilux 4-Eclipse-Set

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

EuroPlan/EuroProfil Panel radiators

Steam Generator v1.0. Model: SI11010N. Helpline. SI11010N_IM.indd 1 01/05/ :34

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR

Thermostatic valve bodies

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Flush individual room control for floor heating systems

This limited warranty is valid for domestic kitchen use and is subject to the terms and conditions stated in this folder.

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Decorative Ceiling Spot Lights

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

This guarantee is subject to the terms and conditions stated in this brochure.

s l it l on for Infrared Heaters

INSTRUCTIONS AND WARRANTY

NOXX. cubicle system

Steel furniture. Individual equipment for offices. Wertheim 09/2008

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

Cooling Strip Model SPB

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic valve bodies

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

Valid from

Free standing convectors with natural convection. new! 02/18

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Chilled Ceiling Elements

5L Water Urn with Gluvine Function SWU5LS. Help line. v1.0

Transcription:

DECO louvre vertical A modern classic

Deco Louvre Vertical Dimensions Louvre Vertical Single Product code wall-mounted: LVSW Product code freestanding: LVSF Louvre Vertical Single Wall / Left or Right Louvre Vertical Double Product code wall-mounted: LVDW Product code Standard freestanding: wall fixing LVDF 4 5 L-14 82 R 3 L-14 82 R 42 17 L 15 4.2 1/2" L-0 30 L 57 20 82 2 LL RR 1 MM 8 7 2 17 90 5.7 L L-0 30 L Ceiling fixing 82 15 57 20 1/2" H-30 H H -30 H 7 min. 100 standard connection variant 107 min. 100 Foot standard connection variant Available lengths 310 370 420 480 540 00 710 770 820 880 940 990 10 1110 1170 1220 1280 Available heights 1200 1400 100 1800 1920 2000 2200 2400 200 2800 3000 L or R ertical Single Wall / Left or Right Connections Standard wall fixing 17 H fixing L 15 R Standard connection L-14 82 Central connection at the bottom end, code MM, flow left or right. 4.2 1/2" Bottom L-0 end connection 30 Order codes: L 18 or 81. (LL and RR also possible) 57 20 82 Fixing Standard wall fixings 3 2 4 5 LL RR 1 MM 8 Key: 1 =flow 2 = return 7 Top end connection Order codes: 45 or 54. Provide and air vent on the central heating tube. Side end connection Side end fixing When ordering a side end fixing, a side end connection is not possible. Cross-over connection Order codes: 48 or 51 Ceiling fixing Single point connection B 20 A Order codes: 22 or 77 Always use a horizontal diffusion tube (Ø10 to 12mm) of minimum length 100mm and a reduction washer. 1 0 min. 100 standard connection variant standard connection variant Foot L or R ertical Double Wall / Left or Right All dimensions in mm 0 R

Options g For positioning of freestanding model For positioning perpendicular to the wall Surcharge for the wall PVSS positioning perpendicular to Surcharge for the wall PVDS positioning perpe 0 1 0 Single or double vertical radiators Minimum length 540mm Diagram showing connection set 42 Standard wall fixing ft or Right Order code: LVSS single radiator = 2 feet + 2 ceiling fixings Order code: LVDS double 4 radiator = 1 feet 5 + 2 ceiling fixings RR LL Single or double vertical radiators Minimum length 540mm- maximum length 10mm. Maximum height 2200mm. Diagram showing connection set 42 RR LL 82 R 4.2 3 To create the order code begin by using the radiator code LVSS or LVDS, then the height in cm, the width in cm, then the colour code followed by the connection then the corner type. Example order code: LVSS.120.031.001 /MM/L or R/ xing 82 ing 1/2" 30 80 1 Side end fixing 2 LL RR 1 MM 8 7 Ceiling fixing Ceiling fixing B A 20 LVSS LVDS 1 0 A 20 37 B 40 8 d connection When ordering side end fixings, a side end connection is not possible. Foot 1 0 Fixings are welded to the radiator and cannot be changed or reordered afterwards. Please check carefully if the desired ft or Right options are ordered correctly. Incorrect orders will not be taken back. The ceiling fixing is the same design as the feet but has a length of 0mm that can be cut down on site as required. 82 R 5.7 Foot 80 1 30 1/2" Side end fixing 20 82 80 1 B A 20 ard connection t B A 20

Outputs Outputs in watts at 75/5/20 C & 55/45/20 C, in accordance with EN442 Supplied as Standard Deco Louvre Vertical Single code height length colour connection corner Order code: LVSW. 120 031 233 /MM /L (Example order code shown is for a 1200mm high radiator, 310mm long.) Colours: 001 Sandblast grey metallic 201 white or 233 traffic white Central connection MM underneath Chrome-plated air vent and drain plug Add to the code L or R Wall fixing Height Length > 310 370 420 480 540 00 710 770 820 880 940 990 10 1110 1170 1220 1280 1200 75/5/20 420 4 588 72 75 840 924 1008 1092 117 120 1344 1428 1512 159 180 174 1848 55/45/20 21 259 302 345 389 432 475 518 51 04 48 91 734 777 820 83 907 9 1400 75/5/20 48 583 80 777 874 971 108 115 122 1359 1457 1554 151 1748 1845 1942 2039 213 55/45/20 2 300 3 400 449 499 549 599 49 99 749 799 849 899 949 999 1049 1098 100 75/5/20 5 59 79 879 989 1099 1209 1319 1429 1539 149 1758 188 1978 2088 2198 2308 2418 55/45/20 283 339 39 452 9 55 22 79 735 792 848 904 91 1018 1074 1131 1187 1244 1800 75/5/20 13 73 858 981 1103 122 1349 1471 1594 171 1839 192 2084 2207 2329 2452 2575 297 55/45/20 315 379 441 5 57 31 94 757 820 883 94 1009 1072 1135 1198 122 1325 1388 1920 75/5/20 51 781 911 1042 1172 1302 1432 152 193 1823 1953 2083 2213 2344 2474 204 2734 284 55/45/20 335 402 49 53 03 70 737 804 871 938 1005 1072 1139 1207 1273 1340 1407 1474 2000 75/5/20 7 811 94 1082 1217 1352 1487 122 1758 1893 2028 213 2298 2434 259 2704 2839 2974 55/45/20 348 417 487 557 2 9 75 835 905 974 1044 1113 1183 1253 1322 1392 141 1531 2200 75/5/20 738 88 1033 1181 1328 147 124 1771 1919 20 2214 232 29 257 2804 2952 3100 3247 55/45/20 380 45 532 08 84 70 83 912 988 104 1140 121 1292 138 1444 1520 1597 172 2400 75/5/20 799 959 1119 1278 1438 1598 1758 1918 2077 2237 2397 2557 2717 287 303 319 335 351 55/45/20 412 494 577 59 741 823 90 988 1070 1153 1235 1318 1400 1482 154 147 1729 1812 200 75/5/20 80 1031 1203 1375 1547 1719 1891 203 2235 2407 2579 27 2922 3094 32 3438 310 3782 55/45/20 443 532 20 709 798 88 975 104 1152 1241 1330 1418 1 1595 184 1772 181 19 2800 75/5/20 920 1103 1287 1471 155 1839 2023 2207 2391 2575 2759 2942 312 3310 3494 378 382 404 55/45/20 475 59 4 759 854 949 1043 1138 1233 1328 1423 1517 112 1707 1802 1897 1992 2087 3000 75/5/20 979 1175 1371 15 172 1958 2154 23 2545 2741 2937 3133 3329 3524 3720 391 4112 4308 55/45/20 5 0 708 808 909 1010 1112 1213 1313 1415 151 117 1718 1819 1920 2021 2122 2223 All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=).

Outputs Outputs in watts at 75/5/20 C & 55/45/20 C, in accordance with EN442 Supplied as Standard Deco Louvre Vertical Double code height length colour connection corner Order code: LVDW. 120 031 001 /MM /L (Example order code shown is for a 1200mm high radiator, 310mm long.) Colours: 001 Sandblast grey metallic 201 white or 233 traffic white Central connection MM underneath Chrome-plated air vent and drain plug Add to the code L or R Wall fixing Height Length > 310 370 420 480 540 00 710 770 820 880 940 990 10 1110 1170 1220 1280 1200 75/5/20 1 739 82 98 1109 1232 1355 1478 102 1725 1848 1971 2094 2218 2341 244 2587 2710 55/45/20 312 374 43 499 51 23 85 748 810 873 935 997 9 1122 1184 1247 1309 1371 1400 75/5/20 714 857 1000 1142 1285 1428 1571 1714 185 1999 2142 2285 2428 2570 2713 285 2999 3142 55/45/20 32 434 7 579 51 724 79 89 941 1013 108 1158 1231 1303 1375 1448 1520 1593 100 75/5/20 809 971 1133 1294 145 118 1780 1942 2103 225 2427 2589 2751 2912 3074 323 3398 350 55/45/20 411 493 57 58 740 822 905 987 109 1151 1233 131 1398 1480 152 145 1727 1809 1800 75/5/20 901 1081 121 1442 122 1802 1982 212 2343 2523 2703 2883 303 3244 3424 304 3784 394 55/45/20 459 551 42 734 82 918 1009 1101 1193 1285 1377 148 150 152 1744 1835 1927 2019 1920 75/5/20 95 1147 1338 1529 1720 1911 2102 2293 2484 275 287 3058 3249 3440 331 3822 4013 4204 55/45/20 488 585 82 780 877 975 1072 1170 127 134 142 150 157 1755 1852 1949 2047 2144 2000 75/5/20 991 1189 1387 158 1784 1982 2180 2378 2577 2775 2973 3171 339 358 37 394 412 430 55/45/20 07 708 810 911 1012 1113 1214 131 1417 1518 119 1720 1822 1923 2024 2125 222 2200 75/5/20 1078 1294 19 1725 1940 215 2372 2587 2803 3018 3234 34 35 3881 409 4312 4528 4743 55/45/20 552 2 772 883 993 1103 1214 1324 1434 1544 155 175 1875 198 209 220 2317 2427 2400 75/5/20 113 1395 128 180 2093 2325 2558 2790 3023 3255 3488 3720 3953 4185 4418 4 4883 5115 55/45/20 59 715 835 954 1073 1192 1311 1430 15 19 1788 1907 2027 2145 225 2384 23 222 200 75/5/20 1245 1493 1742 1991 2240 2489 2738 2987 323 3485 3734 3982 4231 4480 4729 4978 5227 547 55/45/20 40 77 895 1023 1151 1279 1407 1535 13 1791 1919 2047 2175 2303 2431 2559 28 2814 2800 75/5/20 1324 1588 1853 2118 2382 247 2912 317 3441 370 3971 4235 40 475 29 5294 5559 5823 55/45/20 82 818 954 1091 1227 133 10 13 1772 1909 2045 2181 2318 2454 2590 272 283 2999 3000 75/5/20 1400 180 190 2240 2520 2800 3080 330 340 3920 4200 4480 470 40 5320 500 5880 10 55/45/20 723 87 1012 1157 1301 144 1590 1735 1879 2024 219 2313 2458 202 2747 2891 303 3181 All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=).

Connection Sets The order code of the connection set will be completed with the sleeve coupling code Set 31 For connection to the wall Code Thermostatic head CODE.MW2.MW.1... white CODE.MW2.MC.1... chrome CODE.MW2.MB.1... black Set 32 For connection to the floor Deco angled lockshield Deco straight lockshield Deco angled manual valve Thermostatic heads DW Chrome/ White DC Code Thermostatic head CODE.MF2.MW.1... CODE.MF2.MC.1... white chrome Deco straight manual valve Chrome CODE.MF2.MB.1... black Set 33 Set 3 For connection to the wall 33 Standard Kv 3 Reduced Kv Deco angled lockshield CODE.JW2.DW.1... CODE.RW2.DW.1... CODE.JW2.DC.1... CODE.RW2.DC.1... Deco angled thermostatic valve Thermostatic head Set 34 Set 37 For connection to the floor 34 Standard Kv 37 Reduced Kv Deco straight lockshield Deco straight thermostatic valve CODE.JF2.DW.1... CODE.JF2.DC.1... CODE.RF2.DW.1... CODE.RF2.DC.1... Thermostatic head Set 35 Set 38 For connection to the wall Thermostatic head 35 Standard Kv 38 Reduced Kv CODE.JH2.DW.1... CODE.RH2.DW.1... CODE.JH2.DC.1... CODE.RH2.DC.1... Double angled lockshield Double angled thermostatic valve

Set 41 Set 45 For connection to the wall 41 Standard Kv 45 Reduced Kv CODE.PW3.DW.1... CODE.RW3.DW.1... CODE.PW3.DC.1... CODE.RW3.DC.1... Deco-Pro angled valve Thermostatic head Set 42 Set 4 For connection to the floor 42 Standard Kv 4 Reduced Kv CODE.PF3.DW.1... CODE.RF3.DW.1... CODE.PF3.DC.1... CODE.RF3.DC.1... Deco-Pro straight valve Thermostatic head Sleeve Couplings Included in the price of the connection sets For Jaga valve - M24 For flexible steel or copper tube Code Tube Ø 110 10/1 112 12/1 114 14/1 115 15/1 11 1/1 118 18/1 For RPE/ALU tube 1/2 1/2 For tube 15/1 only Deco Single point valve angled 1/2 For tube 18/1 only Deco Single point valve straight Thermostatic head Code For synthetic tube Tube Ø 212 12/2 214 14/2 219 1/1.5 21 1/2 217 17/2 218 18/2 Thermostatic head Steel tube for CH 1/2 1/2 Code Tube Ø 314 14/2 31 1/2 32 1/2.2 318 18/2 1/2 Code Tube Ø 1 1/2 3 3/8 Complete ordering code with sleeve couplings according to the material used and diameter of the tube. The correct type of sleeve coupling is determined by the ordering code of the connection set Example: CODE. JW2.DW. 1. (insert relevant code from above)

Correction factors Average correction factors according to EN442-75/5/20 C TV TL TR_20 25 30 35 40 45 55 0 5 70 75 80 85 90 20 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 1.27 1.34 1.41 1.48 24 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 1.1 1.23 1.29 1.3 85 20 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 1.27 1.314 24 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 1.1 1.23 80 20 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 24 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 75 20 0.4 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 24 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 70 20 0.41 0.4 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 24 0.32 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 5 20 0.35 0.41 0.4 0.51 0.57 0.3 0.9 0.75 0.81 24 0.27 0.32 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0 20 0.30 0.35 0.41 0.4 0.51 0.57 0.3 0.9 24 0.23 0.27 0.32 0.37 0.43 0.48 0.54 0.59 55 20 0.2 0.30 0.35 0.41 0.4 0.51 0.57 24 0.18 0.23 0.27 0.32 0.37 0.43 0.48 20 0.21 0.2 0.30 0.35 0.41 0.4 24 0.14 0.18 0.23 0.27 0.32 0.37 45 20 0.1 0.21 0.2 0.30 0.35 24 0.13 0.17 0.22 0.2 0.31 40 20 0.10 0.14 0.18 0.23 0.27 24 0.12 0.1 0.21 0.2 35 20 0.0 0.10 0.14 0.18 24 0.08 0.12 0.1 30 20 0.03 0.0 0.10 24 0.05 0.08 KEY Tv = flow temperature Tr = return temperature Tl = desired air temperature The indicated outputs with T c and T 30 c are the exact outputs. T c outputs are measured in accordance with EN442 and T 30 c outputs are calculated according to EN442. An average correction factor is given in this table for outputs at other T and is applicable for all dimensions. How to choose the right radiator? Rapid estimation of heat losses Calculate the volume of the room (L x W x H) and multiply this by the Watts/m³ figure given in the table below. Choose according to the level of insulation and the desired room temperature. Insulation 20 24 excellent 45 55 good 5 75 average 85 95 poor 100 115 Required output in Watts/m³ Example Use the table to determine the relevant correction factor with a water temperature of 80/0 c with a room temperature of 24 C. The correction factor = 0.90 Required output 1000 watts : 1000 divided by 0.90 = 1111 watts therefore search in this leaflet s standard output table for a product with an output of at least 1111 watts. Alternatively use the Radiator Finder search function on www.jaga.co.uk to identify all Jaga heating products with this required output. Output calculated in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=).

Pressure drop mwk mce mws mwc 1 0.8 0. 0.5 0.4 0.3 0.2 bar 0.1 0.08 0.0 0.05 0.04 0.03 0.02 kpa 10 8 5 4 3 2 Pressure drop 0.1 0.08 0.0 0.05 0.04 0.03 0.02 0.01 0.008 0.00 0.005 0.004 0.003 0.002 1 0.8 0. 0.5 0.4 0.3 0.2 0.01 0.008 0.00 0.005 0.004 0.003 0.002 0.001 0.0008 0.000 0.0005 0.0004 0.0003 0.0002 0.1 0.08 0.0 0.05 0.04 0.03 0.02 0.001 0.0001 10 0.01 2 3 4 8 2 3 4 8 100 1000 Water flow in kg/h Weight & water content Weight in kg/cm Water content in litres/cm H Single Double 1200 0.3 0.8 1400 0.41 0.78 100 0.4 0.89 1800 0.51 0.99 1920 0.54 1.05 2000 0.5 1.09 2200 0.1 1.19 2400 0. 1.29 200 0.71 1.39 2800 0.7 1. 3000 0.81 1.0 H Single Double 1200 0.10 0.20 1400 0.11 0.23 100 0.13 0.2 1800 0.14 0.28 1920 0.15 0.30 2000 0.1 0.31 2200 0.17 0.34 2400 0.18 0.37 200 0.2 0.40 2800 0.21 0.42 3000 0.23 0.45

Product description Deco Louvre Vertical Material Composed of single or double steel collectors which support the steel radiation tubes. The radiation tubes are welded on the inside of the collector under the protection of gas, and with steel as a sole addition. Therefore no welding seams are visible on the outside of the radiator. Pressure test: bar Working pressure:4. bar Composition The oval radiation tubes (0 x 10.4 x 1.5mm) are vertically and lengthways placed on the horizontal collector with in an angle of 15. Single collector : x 30 x 3mm Double collector: 90 x 30 x3mm Transparency: from one side only All fixing points are welding to the radiator. The supports to fit the wall are supplied with the standard delivery. Finish The radiators are sandblasted, degreased, phosphated, electrostatically lacquered with epoxy-polyester powder and finally stove enameled at 200 C. This high quality finish offers an optimal scratch resistance and is very easy to maintain. Thickness of the lacquer: min80 μ Connections The sockets ½ are integrated in the collectors and hence invisible. The sockets ½ at the side end of the collectors stick out 3 mm above the collector end. The connections may be ordered at customer choice at top, bottom or at the side end of the radiator. Provided with a chrome plated air vent ½ and drain plug ½ How to install The building services engineer chooses the radiators considering the following conditions: A heat output calculation according to the standard. The heat output and the dimensions of the Deco Louvre radiators according to EN 442. The radiators may be wall fitted with the wall fixings supplied, positioned perpendicular to the wall with 2 side end fixings left and 1 foot right or positioned perpendicular to the wall with 2 side end fixings right and 1 foot left. The specially designed thermostatic connection sets/ thermostatic Jaga Deco/ Deco-Pro valves/ manual Jaga Deco valves can be connected to plastic central heating service pipes/ RPE/ALU. Tube / copper tube/ steel pipe. Jaga thermostatic heads/jaga Deco thermostatic heads chrome/ White/ Jaga Comap thermostatic heads silver/not to be/ to be fitted.

Jaga colours For Deco Louvre Vertical Standard colours RAL 9010 201 White RAL 901 233 001 Traffic White Sandblast Grey Metallic Premium colours RAL 9001 RAL 9010 301 White 202 302 Off-white RAL 009 212 312 Bahama 213 313 English Green 222 322 Capri 223 323 Natural Special colours RAL 7035 203 303 Light Grey 214 314 Whisper Rose 224 324 Edelweis 002 Hammerstroke Silver/Black RAL 9005 204 304 Black RAL 18 215 315 Turquoise 225 325 Jasmine 003 Claret Metallic 205 305 Pergamon 21 31 Bermuda RAL 3003 22 32 Ruby Red 005 Smooth Grey Metallic 20 30 Manhattan RAL 8017 217 317 Chocolate Brown 228 328 Classic White RAL 900 00 Aluminium RAL 03 RAL 7011 RAL 1004 208 308 Sapphire Blue 209 309 Dark Grey 210 310 Golden Yellow RAL 15 RAL 4008 218 318 Azure 219 319 Violet 220 320 Aegean RAL 000 RAL 701 229 329 Patina Green 230 330 Aloa Blue 231 331 Anthracite Grey 007 Anthracite Metallic 008 Anthracite Structure RAL 3000 211 311 Flaming Red 221 321 Calypso 232 332 Sunrise RAL 901 333 Traffic White As it s impossible to reproduce colours with 100% accuracy, this colour chart is intended as a guide only. Colour swatches are available on request.

Jaga Guarantee Information 1 The guarantee is valid only if the equipment is properly and correctly used, by its first owner and if installed in accordance with the norms and instructions as detailed in the instruction leaflet and current industry standard practices. 2 The guarantee only applies to the equipment and the spare parts supplied by Jaga. Jaga has the choice between repair and replacement of the equipment or the spare parts. If any modifications have been made by Jaga to the standard product design, Jaga reserves the right to replace the guaranteed equipment with equivalent products or spare parts. 3 The period of guarantee is mentioned in this certificate. The guarantee decreases every year on a straight line basis by an equal percentage in order to reach a zero guarantee at the end of the guarantee period (e.g. for a period of 10 years the annual decrease of the guarantees 10% of the invoiced value). Repaired or replaced product is guaranteed through to the end of the original guarantee period. 4 The guarantee is valid only on products displaying the appropriate identification information concerning product type and series. No guarantee is granted on equipment or spare parts lacking this information, on equipment where this information has been removed or altered, or on equipment that has been repaired or modified by persons not authorised by Jaga to carry out this work. 5 The customer is responsible for any damage caused as a result of errors in installation or use of incorrect fittings, or for any damage caused by electrical connections, faulty or damaged electrical installations or appliances, erroneous voltage or hydraulic pressure and all other errors not directly related to the product delivered by Jaga. The guarantee is also revoked when unsuitable parts or components are used. The guarantee for our heat exchangers is not valid if they are regularly drained, or if they are heated by means of industrial water, steam or water saturated by excessive quantities of oxygen. The quality of the system ater has to be in accordance with the VDI 2035-2 directives. The guarantee is also not applicable if the heat exchangers are placed in unsuitable atmospheric surroundings, such as but not exclusively ammonia, caustic substances etc. This guarantee excludes damage due to incorrect handling and/or use of the equipment, or due to formation of lime deposits, incorrect use of the safety valve, or to all equipment that is incorporated into the building in a way that means it cannot be accessed normally. 7 Any work undertaken or product supplied as a result of a guarantee claim that proves not to be valid will be charged for. Product supplied will be invoiced at the customer s standard purchasing terms, and labour will be charged at per hour with a minimum labour charge of 200. 8 The guarantee period starts from the date of the invoice for supply of the products covered by the guarantee. If the invoice is not available, the date of production will be used based on the product ID number/series. 9 Only the courts of judicial district Hasselt (Belgium) are authorised to deal with disputes arising from this guarantee. It will apply Belgian law even when sales involved are subjects of EU member states as well as non-eu member countries. Casings and components Valves