DECO louvre horizontal. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

Similar documents
panel plus horizontal wall-mounted

A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

DECO louvre vertical. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

ARISTOCRAT. Elite towel rail for every situation

arco plus Distinctively elegant vertical radiators

IGUANA visio. Radiators that mirror your style

High output, high art. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

IGUANA circo wall-mounted. Distinctively elegant vertical radiators

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

circo PLUS wall-mounted

Play DBE. Colourful, fun, safe. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

BRISE. Heating and cooling from a single radiator

Basic DBE. Easy installation in less than two hours

FREEDOM 2019.EX CZ - 21/11/18

QUATRO CANAL 2019.EX

CLIMA CANAL Lyngson as

VeRtiga the new benchmark for design at super-low water temperatures

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Units for suspended ceilings

Passive chilled beams

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

MINI CANAL DBE 2015.UK

Zehnder Electric radiators for living rooms

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

BRIZA Super slim and powerful heating, cooling

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

new DRAFT This is not the final version of this document! But prices and outputs should be good. play Playful warmth, colourful comfort

IMI Heimeier Kit Hydroca ble

Units for suspended cei lings

Quatro canal Super-powered climate control for 4-pipe systems

BRISE. Super-power for heating, cooling and ventilation.

IRONING BOARD CATALOG FOR HOME

CLIMA CANAL. Complete climate control and high power

VOGEL&NOOT. Convectors & heating panels. heatingthroughinnovation.

Type CODE Speed Heating Cooling

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

WHE 2.24 / WHE 2.24 FF

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

PLAN KLASIK LINE KLASIK

Mikrotherm. Manual Radiator Valves With presetting

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

BOOST INTO THE FUTURE

Metering systems 0548EN April 2014

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

INSTRUCTIONS AND WARRANTY

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Brochure EX

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

CLIMA CANAL Complete climate control and high power

made in Italy Extruded Radiators with Anticorrosion Treatment

EuroPlan/EuroProfil Panel radiators

Towel Warmers Electric Rad catalogue

Thermostatic valves with radiator connection systems

Multilux 4-Eclipse-Set

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

EuroPlan/EuroProfil Panel radiators

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

Thermostatic valve bodies

This limited warranty is valid for domestic kitchen use and is subject to the terms and conditions stated in this folder.

Flush individual room control for floor heating systems

Chilled Ceiling Elements

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

AHRI Guideline N with Addendum Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Decorative Ceiling Spot Lights

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Steel furniture. Individual equipment for offices. Wertheim 09/2008

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

This guarantee is subject to the terms and conditions stated in this brochure.

NOXX. cubicle system

INSTRUCTIONS AND WARRANTY

s l it l on for Infrared Heaters

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Ceramic soleplate steam iron. Help line: Model: SI30110BLKN v1.0

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

Steam Generator v1.0. Model: SI11010N. Helpline. SI11010N_IM.indd 1 01/05/ :34

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Cooling Strip Model SPB

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic valve bodies

Free standing convectors with natural convection. new! 02/18

Valid from

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Transcription:

DECO louvre horizontal A modern classic

Deco Louvre Horizontal Dimensions Louvre Horizontal Single Product code wall-mounted: LHSW Product code freestanding: LHSF Louvre Horizontal Double Product code wall-mounted: LHDW Product code freestanding: LHDF L-10 80 L-10 80 12 5 12 90 57 L-30 L 37 L-30 L 102 37 1/2" 2 H-0 min. 100 H 30 20 standard connection variant 15 57 0 102 102 52 102 1/2" H-0 30 min. 100 H 20 standard connection variant 57 0 15 102 Available lengths 1000 1200 1400 100 1800 2000 2200 2400 200 2800 3000 Available heights 310 370 420 480 540 00 50 710 770 820 880 940 12 min. 100 H 30 uvre Horizontal Single Wall 5 20 all fixing Connections L-10 80 Standard connection Order L-30 code: 18. Connection L 18 or 81. 37 Side end connection One-sided: code 32 or 7. Cross-over: code 37 or 2. standard connection variant Fixings 15 57 0 102 Standard wall fixing 3 2 1 8 Key: 1 =flow 2 = return 7 Standard wall fixing Single point connection Order codes: 11(left) or 88 (right) Always use a vertical diffusion tube (Ø 10 to 12mm) of minimum length 100mm and a reduction washer. Foot 150 LHSF 25 80 135 105 LHDF 25 80 uvre Horizontal Double Wall Side end fixing 12 90 L-10 80 57 B A 20 All dimensions in mm 30 20 L-30 L LHDF 15

MM Options Side end fixing Surcharge for freestanding model PVSF Surcharge for freestanding model PVDF B A 20 LHSS LHDS A 20 37 B 40 8 When ordering side end fixings, a side end connection is not possible. Fixings are welded to the radiator and cannot be changed or reordered afterwards so please check carefully when ordering as incorrect orders cannot be returned. For positioning perpendicular to the wall Surcharge for the wall PVSS positioning perpendicular to Surcharge for the wall PVDS positioning perpendicular to RR LL 0 50 0 50 Order code: LVSS single radiator = 2 feet + 2 ceiling fixings Order code: LVDS double radiator = 1 feet + 2 ceiling fixings To create the order code begin by using the radiator code LVSS or LVDS, then the height in cm, the width in cm, then the colour code followed by the connection then the corner type. Example order code: LVSS.120.031.001 /MM/L or R/ Single or double vertical radiators Minimum length 540mm- maximum length 1050mm. Maximum height 2200mm. Diagram showing connection set 42 For positioning of freestanding model LHSF - Single LHDF - Double 3 3 3 2 7 2 7 2 7 Single or double radiator Maximum height 480mm. Connection set options 31 or 33. Order codes: LHSF = single radiator up to L2200 + 2 feet from L 2400 3 feet LHDF = double radiator up to L2200 + 2 feet from L 2400 3 feet To create the order code begin by using the radiator code LHSF or LHDF, then the height in cm, the width in cm, then the colour code followed by the connection. Order code example: LHSF. 031 100. 001/32 or 7

Outputs Outputs in watts at 75/5/20 C & 55/45/20 C, in accordance with EN442 Deco Louvre Horizontal Single code height length colour connection Order code: LHSW. 031 100 201 /18 (Example order code shown is for a 310mm high radiator, 1000mm long.) Height Length > 1000 1200 1400 100 1800 2000 2200 2400 200 2800 3000 310 75/5/20 358 430 502 573 45 717 788 80 932 1003 1075 55/45/20 181 218 254 290 327 33 399 43 472 508 544 370 75/5/20 440 528 1 704 792 880 97 1055 1143 1231 1319 55/45/20 223 28 313 357 402 447 491 535 580 25 9 420 75/5/20 522 2 730 835 939 1044 1148 1252 1357 141 155 55/45/20 25 318 371 425 477 531 584 37 90 743 79 480 75/5/20 04 725 84 9 1087 1208 1329 1450 1570 191 1812 55/45/20 308 39 431 492 554 15 77 738 800 81 923 540 75/5/20 8 823 90 1098 1235 1372 1509 14 1784 1921 2058 55/45/20 350 420 490 50 30 700 770 840 910 980 1050 00 75/5/20 78 921 1075 1228 1382 1535 189 1843 199 2150 2303 55/45/20 393 471 549 28 70 785 83 942 1020 1099 1177 50 75/5/20 849 1019 1188 1358 1528 198 188 2037 2207 2377 2547 55/45/20 435 522 08 95 783 870 957 1043 1130 1217 1304 710 75/5/20 929 1115 1301 1487 173 1859 2044 2230 241 202 2788 55/45/20 47 572 7 73 858 954 1048 1144 1239 1335 1430 770 75/5/20 1009 1211 1412 114 181 2018 2220 2421 223 2825 3027 55/45/20 519 22 72 830 933 1037 1141 1244 1348 1452 155 820 75/5/20 1088 1305 1523 1740 1958 2175 2393 210 2828 3045 323 55/45/20 50 72 784 89 1008 1120 1232 1343 145 157 180 880 75/5/20 115 1398 131 184 2097 2330 253 279 3029 322 3495 55/45/20 01 721 841 91 1082 1202 1322 1442 152 183 1803 940 75/5/20 1242 1490 1738 1987 2235 2483 2732 2980 3228 347 3725 55/45/20 42 770 898 102 1155 1283 1411 1539 18 179 1924 Supplied as Standard Colours: 001 Sandblast grey metallic 201 white or 233 traffic white Connection 18 underneath Chrome-plated air vent and drain plug Wall fixing All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=50).

Outputs Outputs in watts at 75/5/20 C & 55/45/20 C, in accordance with EN442 Deco Louvre Horizontal Double code height length colour connection Order code: LHDW. 031 100 233 /18 (Example order code shown is for a 310mm high radiator, 1000mm long.) Supplied as Standard Colours: 001 Sandblast grey metallic 201 white or 233 traffic white Height Length > 1000 1200 1400 100 1800 2000 2200 2400 200 2800 3000 310 75/5/20 52 783 913 1044 1174 1304 1435 155 19 182 1957 55/45/20 337 405 472 540 07 75 742 810 877 945 1013 370 75/5/20 777 932 1088 1243 1398 1554 1709 185 2020 2175 2331 55/45/20 4020 4820 530 430 7230 8040 8840 950 10450 11250 1200 420 75/5/20 900 1081 121 1441 121 1801 1981 211 2341 2521 2701 55/45/20 4 50 53 74 839 932 1025 1119 1212 1305 1398 480 75/5/20 1023 1227 1432 137 1841 204 2250 2455 259 284 309 55/45/20 530 35 742 848 953 100 115 1271 1377 1483 1589 540 75/5/20 1144 1373 102 1831 200 2289 2517 274 2975 3204 3433 55/45/20 592 711 830 948 107 118 1304 1422 1541 159 1778 00 75/5/20 125 1518 1771 2024 2277 2530 2783 303 3289 3541 3794 55/45/20 55 787 918 1049 1180 1311 1442 1573 1704 1835 19 50 75/5/20 1384 11 1938 2215 2492 279 304 3323 3599 387 4153 55/45/20 717 81 1004 1148 1291 1435 1578 1722 185 2008 2152 710 75/5/20 1503 1804 2104 2405 270 300 3307 308 3908 4209 4510 55/45/20 779 935 1091 1247 1403 1558 1714 1871 202 2182 2338 770 75/5/20 121 1945 2270 2594 2918 3242 35 3891 4215 4539 483 55/45/20 841 1009 1177 134 1514 182 1850 2018 218 2354 2522 820 75/5/20 1738 208 2433 2781 3129 347 3824 4172 4519 487 5215 55/45/20 902 1082 122 1443 123 1803 1984 214 2344 2525 2705 880 75/5/20 1855 2225 259 297 3338 3709 4080 4451 4822 5193 554 55/45/20 93 1155 1347 1540 1732 1925 2117 2310 2502 295 2888 940 75/5/20 1970 234 2758 3152 354 3940 4334 4728 5122 551 5910 55/45/20 1022 1227 1431 13 1840 2045 2249 2454 258 283 307 Connection 18 underneath Chrome-plated air vent and drain plug Wall fixing All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=50).

Connection Sets The order code of the connection set will be completed with the sleeve coupling code Set 31 For connection to the wall Thermostatic head CODE.MW2.MW.1... white CODE.MW2.MC.1... chrome CODE.MW2.MB.1... black Set 32 For connection to the floor Deco angled lockshield Deco straight lockshield Deco angled manual valve Thermostatic heads DW Chrome/ White DC Thermostatic head CODE.MF2.MW.1... CODE.MF2.MC.1... white chrome Deco straight manual valve Chrome CODE.MF2.MB.1... black Set 33 Set 3 For connection to the wall 33 Standard Kv 3 Reduced Kv Deco angled lockshield CODE.JW2.DW.1... CODE.RW2.DW.1... CODE.JW2.DC.1... CODE.RW2.DC.1... Deco angled thermostatic valve Thermostatic head Set 34 Set 37 For connection to the floor 34 Standard Kv 37 Reduced Kv Deco straight lockshield Deco straight thermostatic valve CODE.JF2.DW.1... CODE.JF2.DC.1... CODE.RF2.DW.1... CODE.RF2.DC.1... Thermostatic head Set 35 Set 38 For connection to the wall Thermostatic head 35 Standard Kv 38 Reduced Kv CODE.JH2.DW.1... CODE.RH2.DW.1... CODE.JH2.DC.1... CODE.RH2.DC.1... Double angled lockshield Double angled thermostatic valve

Connection Sets The order code of the connection set will be completed with the sleeve coupling code Set 81 For connection to the wall CODE.OW2.DW.1... Thermostatic head CODE.OW2.DC.1... Set 82 For connection to the floor Thermostatic head CODE.OF2.DW.1... CODE.OF2.DC.1... Deco Single point valve angled Deco Single point valve straight Thermostatic head Thermostatic head Sleeve Couplings Included in the price of the connection sets For Jaga valve - M24 For flexible steel or copper tube For synthetic tube Tube Ø Tube Ø 110 10/1 112 12/1 114 14/1 115 15/1 11 1/1 118 18/1 1/2 1/2 For tube 15/1 only 1/2 For tube 18/1 only 212 12/2 214 14/2 219 1/1.5 21 1/2 217 17/2 218 18/2 1/2 For RPE/ALU tube Steel tube for CH 1/2 Tube Ø 314 14/2 1/2 Tube Ø 501 1/2 31 1/2 503 3/8 32 1/2.2 318 18/2 Complete ordering code with sleeve couplings according to the material used and diameter of the tube. The correct type of sleeve coupling is determined by the ordering code of the connection set Example: CODE. JW2.DW. 1. (insert relevant code from above)

Correction factors Average correction factors according to EN442-75/5/20 C TV TL TR_20 25 30 35 40 45 50 55 0 5 70 75 80 85 90 20 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 1.27 1.34 1.41 1.48 24 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 1.1 1.23 1.29 1.3 85 20 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 1.27 1.314 24 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 1.1 1.23 80 20 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 1.13 1.20 24 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 1.03 1.09 75 20 0.4 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 1.00 1.07 24 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 0.90 0.9 70 20 0.41 0.4 0.51 0.57 0.3 0.9 0.75 0.81 0.87 0.94 24 0.32 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0.77 0.83 5 20 0.35 0.41 0.4 0.51 0.57 0.3 0.9 0.75 0.81 24 0.27 0.32 0.37 0.43 0.48 0.54 0.59 0.5 0.71 0 20 0.30 0.35 0.41 0.4 0.51 0.57 0.3 0.9 24 0.23 0.27 0.32 0.37 0.43 0.48 0.54 0.59 55 20 0.2 0.30 0.35 0.41 0.4 0.51 0.57 24 0.18 0.23 0.27 0.32 0.37 0.43 0.48 50 20 0.21 0.2 0.30 0.35 0.41 0.4 24 0.14 0.18 0.23 0.27 0.32 0.37 45 20 0.1 0.21 0.2 0.30 0.35 24 0.13 0.17 0.22 0.2 0.31 40 20 0.10 0.14 0.18 0.23 0.27 24 0.12 0.1 0.21 0.2 35 20 0.0 0.10 0.14 0.18 24 0.08 0.12 0.1 30 20 0.03 0.0 0.10 24 0.05 0.08 KEY Tv = flow temperature Tr = return temperature Tl = desired air temperature The indicated outputs with T 50 c and T 30 c are the exact outputs. T 50 c outputs are measured in accordance with EN442 and T 30 c outputs are calculated according to EN442. An average correction factor is given in this table for outputs at other T and is applicable for all dimensions. How to choose the right radiator? Rapid estimation of heat losses Calculate the volume of the room (L x W x H) and multiply this by the Watts/m³ figure given in the table below. Choose according to the level of insulation and the desired room temperature. Insulation 20 24 excellent 45 55 good 5 75 average 85 95 poor 100 115 Required output in Watts/m³ Example Use the table to determine the relevant correction factor with a water temperature of 80/0 c with a room temperature of 24 C. The correction factor = 0.90 Required output 1000 watts : 1000 divided by 0.90 = 1111 watts therefore search in this leaflet s standard output table for a product with an output of at least 1111 watts. Alternatively use the Radiator Finder search function on www.jaga.co.uk to identify all Jaga heating products with this required output. Output calculated in accordance with EN442, at a water temperature of 75/5 C and a room temperature of 20 C (ΔT=50).

Pressure drop mwk mce mws mwc 1 0.8 0. 0.5 0.4 0.3 0.2 bar 0.1 0.08 0.0 0.05 0.04 0.03 0.02 kpa 10 8 5 4 3 2 Pressure drop 0.1 0.08 0.0 0.05 0.04 0.03 0.02 0.01 0.008 0.00 0.005 0.004 0.003 0.002 1 0.8 0. 0.5 0.4 0.3 0.2 0.01 0.008 0.00 0.005 0.004 0.003 0.002 0.001 0.0008 0.000 0.0005 0.0004 0.0003 0.0002 0.1 0.08 0.0 0.05 0.04 0.03 0.02 0.001 0.0001 10 0.01 2 3 4 8 2 3 4 8 100 1000 Water flow in kg/h Weight & water content Weight in kg/cm Water content in litres/cm H Single Double 310 0.09 0.17 370 0.11 0.21 420 0.13 0.24 480 0.14 0.27 540 0.1 0.31 00 0.18 0.34 50 0.2 0.38 710 0.22 0.41 770 0.23 0.44 820 0.25 0.48 880 0.27 0.51 940 0.29 0.54 990 0.3 0.58 1050 0.32 0.1 1110 0.34 0.5 1170 0.3 0.8 H Single Double 310 0.02 0.048 370 0.031 0.058 420 0.03 0.08 480 0.041 0.078 540 0.04 0.087 00 0.051 0.097 50 0.05 0.107 710 0.01 0.11 770 0.07 0.12 820 0.072 0.13 880 0.077 0.145 940 0.082 0.155 990 0.087 0.15 1050 0.092 0.175 1110 0.097 0.184 1170 0.102 0.194

Product description Deco Louvre Horizontal Material Composed of single or double steel collectors which support the steel radiation tubes. The radiation tubes are welded on the inside of the collector under the protection of gas, and with steel as a sole addition. Therefore no welding seams are visible on the outside of the radiator. Pressure test: bar Working pressure: 4. bar Composition The oval radiation tubes (0 x 10.4 x 1.5mm) are horizontally and lengthways placed on the vertical collector with in an angle of 15. Single collector : 50 x 30 x 3mm Double collector: 90 x 30 x3mm Transparency: none All fixing points are welding to the radiator. The supports to fit the wall are supplied with the standard delivery. Finish The radiators are sandblasted, degreased, phosphated, electrostatically lacquered with epoxy-polyester powder and finally stove enameled at 200 C. This high quality finish offers an optimal scratch resistance and is very easy to maintain. Thickness of the lacquer: min80 μ Connections The sockets ½ are integrated in the collectors and hence invisible. The sockets ½ at the top end and bottom end of the collectors stick out 3 mm above the collector end. The connections may be ordered at customer choice at top, bottom or at the side end of the radiator. Provided with a chrome plated air vent ½ and drain plug ½ How to install The building services engineer chooses the radiators considering the following conditions: A heat output calculation according to the standard. The heat output and the dimensions of the Deco Louvre horizontal radiators according to EN 442. The radiators may be wall fitted with the wall fixings supplied, positioned perpendicular to the wall with 2 side end fixings left and 1 foot right or positioned perpendicular to the wall with 2 side end fixings right and 1 foot left. The specially designed thermostatic connection sets/ thermostatic Jaga Deco/ Deco-pro single point valves/ manual Jaga Deco valves can be connected to plastic central heating service pipes/ RPE/ALU. Tube / copper tube/ steel pipe. Jaga thermostatic heads/jaga Deco thermostatic heads chrome/ White/ Jaga Comap thermostatic heads silver/not to be/ to be fitted.

Jaga colours For Deco Louvre Horizontal Standard colours RAL 9010 201 White RAL 901 233 001 Traffic White Sandblast Grey Metallic Premium colours RAL 9010 301 White 212 312 Bahama 222 322 Capri RAL 9001 202 302 Off-white RAL 009 213 313 English Green 223 323 Natural Special colours RAL 7035 203 303 Light Grey 214 314 Whisper Rose 224 324 Edelweis 002 Hammerstroke Silver/Black RAL 9005 204 304 Black RAL 5018 215 315 Turquoise 225 325 Jasmine 003 Claret Metallic RAL 5003 RAL 7011 205 305 Pergamon 20 30 Manhattan 208 308 Sapphire Blue 209 309 Dark Grey RAL 8017 RAL 5015 RAL 4008 21 31 Bermuda 217 317 Chocolate Brown 218 318 Azure 219 319 Violet RAL 3003 RAL 000 22 32 Ruby Red 228 328 Classic White 229 329 Patina Green 230 330 Aloa Blue RAL 900 005 Smooth Grey Metallic 00 Aluminium 007 Anthracite Metallic RAL 1004 210 310 Golden Yellow 220 320 Aegean RAL 701 231 331 Anthracite Grey 008 Anthracite Structure RAL 3000 211 311 Flaming Red 221 321 Calypso 232 332 Sunrise RAL 901 333 Traffic White As it s impossible to reproduce colours with 100% accuracy, this colour chart is intended as a guide only. Colour swatches are available on request.

Jaga Guarantee Information 1 The guarantee is valid only if the equipment is properly and correctly used, by its first owner and if installed in accordance with the norms and instructions as detailed in the instruction leaflet and current industry standard practices. 2 The guarantee only applies to the equipment and the spare parts supplied by Jaga. Jaga has the choice between repair and replacement of the equipment or the spare parts. If any modifications have been made by Jaga to the standard product design, Jaga reserves the right to replace the guaranteed equipment with equivalent products or spare parts. 3 The period of guarantee is mentioned in this certificate. The guarantee decreases every year on a straight line basis by an equal percentage in order to reach a zero guarantee at the end of the guarantee period (e.g. for a period of 10 years the annual decrease of the guarantees 10% of the invoiced value). Repaired or replaced product is guaranteed through to the end of the original guarantee period. 4 The guarantee is valid only on products displaying the appropriate identification information concerning product type and series. No guarantee is granted on equipment or spare parts lacking this information, on equipment where this information has been removed or altered, or on equipment that has been repaired or modified by persons not authorised by Jaga to carry out this work. 5 The customer is responsible for any damage caused as a result of errors in installation or use of incorrect fittings, or for any damage caused by electrical connections, faulty or damaged electrical installations or appliances, erroneous voltage or hydraulic pressure and all other errors not directly related to the product delivered by Jaga. The guarantee is also revoked when unsuitable parts or components are used. The guarantee for our heat exchangers is not valid if they are regularly drained, or if they are heated by means of industrial water, steam or water saturated by excessive quantities of oxygen. The quality of the system ater has to be in accordance with the VDI 2035-2 directives. The guarantee is also not applicable if the heat exchangers are placed in unsuitable atmospheric surroundings, such as but not exclusively ammonia, caustic substances etc. This guarantee excludes damage due to incorrect handling and/or use of the equipment, or due to formation of lime deposits, incorrect use of the safety valve, or to all equipment that is incorporated into the building in a way that means it cannot be accessed normally. 7 Any work undertaken or product supplied as a result of a guarantee claim that proves not to be valid will be charged for. Product supplied will be invoiced at the customer s standard purchasing terms, and labour will be charged at 50 per hour with a minimum labour charge of 200. 8 The guarantee period starts from the date of the invoice for supply of the products covered by the guarantee. If the invoice is not available, the date of production will be used based on the product ID number/series. 9 Only the courts of judicial district Hasselt (Belgium) are authorised to deal with disputes arising from this guarantee. It will apply Belgian law even when sales involved are subjects of EU member states as well as non-eu member countries. Casings and components Valves