F&G detection system for LNG plants

Similar documents
Autronica Fire and Security AS ID:

GAS DETECTORS. When every second counts

Flame Detection Jon Sarfas

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

AUTROSAFE. An interactive fire detection system for larger vessels

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

AUTROSAFE 4 A new level in interactive fire detection systems

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Meeting NFPA standards for

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Protect your people, assets and environment while ensuring operational performance.

Alternative Fuels Applications

Selecting fire and gas detectors for extreme environments:

Case Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION

Industrial Grade Gas Detection

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

Selecting fire and gas detectors for harsh and remote locations

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

Fire protection in hazardous locations:

2015 Honeywell Users Group Europe, Middle East and Africa

Integrating Fire and Gas Safety with Process Control Systems:

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

DIPL Solutions and Services

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

FM Approved Fire & Gas Detection System

Selecting fire and gas detectors for extreme environments

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Dräger Flame 2500 Flame Detection

Smoke detection in hazardous areas:

For Complete Fire and Gas Solutions

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

SINGLE MONITORED INPUT UNIT BN-303

Explosion Protection Engineering Principles

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Dräger Flame 2100 Flame Detection

GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS

System Design and Engineering AutroSafe Interactive Fire & Gas Detection System (IFG)

Instructions AutroFlame IR Flame Detector BG-201/BG-21

explosion protection automation global partner of the process industry

Fire and Gas Detection and Mitigation Systems

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Leak Detection - Application Note

Document TM777030, rev. B. Initial release: 22 January 2008 Current release: 16 February 2010

Fully configurable SIL2 addressable Fire & Gas Detection solutions

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

Johnson Controls Security Solutions for Oil and Gas

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Fire and gas safety systems:

SIL 2. Ultima X Series Gas Monitors CERTIFIED

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

HART XL High Sensitivity Smoke Detection

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Sieger Apex. Flexibility that meets your requirements

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

U L T R A S O N I C G A S L E A K D E T E C T O R

HART XL High Sensitivity Smoke Detection

The benefits of modern Integrated Control and Safety Systems architectures for FPSO facilities.

Marine Solutions. Honeywell s Solution for LNG Vessels

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Safety Instrumented Fire & Gas Systems

Industrial Grade Gas Detection

FIRE SUPPRESSION SOLUTIONS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Safety Instrumented Systems The Smart Approach

Gas Detection in Process Industry The Practical Approach

Fire Detection systems. UniVario industrial fire detectors for every job

New requirements for IEC best practice compliance

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

MSA Fixed Gas & Flame Detection for the Automotive Industry

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Dräger REGARD -1 Control System

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

Dependable Solutions for Gas Detection

Industrial Grade Gas Detection Detecting The Difference

T.ex Single Gas Detector VISA

A New Standard of Excellence

Client's Name. Duration (Months) ESD control system upgrading in SALAM CORE PLANT. Target Engineering had conducted detailed engineering in 1993.

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

AutroFlame X33AF. Addendum. Multi-spectrum IR flame detector. Protecting life, environment and property...

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

FAAST PRODUCT RANGE Aspirating Smoke Detection

Transcription:

LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an installation. Different levels of protection ensure that potential hazards are discovered and eliminated before they become a major risk to the installation premises and the people working there.

The reliability is important for the entire system and not only single components. While LNG in its original form is a liquid, it will quickly turn into a vaporized gas upon entering the atmosphere. Potential ignition sources may quickly create a dangerous situation, and thus our goal is to discover any atmospheric presence of gas as early as possible. This is why the detection system becomes an early and important barrier to protect an LNG plant. Detecting potential risks and taking necessary precautions to eliminate or prevent them from escalating is the main objective of the safety system. Several factors need to be examined in order to make sure that we have a trustworthy system. Typical detection solution There are two key factors when considering an F&G detection system: Availability and Reliability. The first is rather self-explanatory it is important that the detection system (and its functions) is available when needed. The latter is no less important that we can rely on the system to perform when needed. The first step to ensure we can trust our system is to look at the Detection system Output (action) Distributed control system (DCS) Every scenario (a beginning fire, a gas leak, etc.) can be reported by a detector. The detector is the system s initiating device, and its performance is crucial to ensure early and reliable detection. We want to detect the incident as early as possible, and at the same time avoid detection and reporting of unwanted or nuisance alarms. Different detectors have different properties, particularly when it comes to performance. Comparing datasheets may cause detectors which perform very different to look almost the same. When consulting manufacturers and suppliers of fire and gas equipment, a good rule of thumb is to always ask what testing has been done according to performance standards (e.g. FM3260 for flame detection). This will point out the differences when it comes to the performance of a specific device. It is of course important that the equipment has the right ingress protection and can withstand necessary environmental conditions, but after all it is the performance of the device that determines whether it will properly detect an incident or not. The detector will report a detected incident to the detection system. By this, the communication becomes important (type of medium, robustness to EMC and environmental conditions, etc.) to avoid loss or delay in the communication channel. This is also a driving factor to try and utilize a loop or another form of redundancy for the communication between the detector and the system. In a loop, short-circuit isolators will ensure that any detector or cable faults will keep all other devices properly communicating with the system. Integrated Fire and Gas Detection System F&G detector (initiating device) chain of devices necessary to detect and take appropriate action. A very simplified drawing showing a typical safety system for detection is shown below. Output (action) The purpose of the detection system itself is also to ensure that any appropriate actions are taken. In an integrated fire and gas detection system, the logic is normally kept in the same system and actions are taken care of by activating outputs to different devices (activating beacons/sounders, closing ventilation/ dampers etc). An alternative configuration is as shown in the figure on the left; the detection system passes the alarm on to a Distributed Control System (DCS) which will take care of the needed actions. For the last solution, it is important to highlight the need for a secure communication channel between the two systems. Very often the project will also require redundancy for this type of communication. Combining single components does not necessarily give us the same rating (even if they are rated SIL2 individually). To make sure we can maintain all aspects of IEC 61508, a Safety Analysis Report (SAR) is often done during the project. In order to simplify this and ensure you will maintain the required safety level, you should ask the suppliers to prove compliance of the entire system according to IEC61508. This will ease the projecting of a safety system. Safety and IEC 61508 In most cases, an LNG plant is a wide installation with long distances between areas/structures. The installation consists of buildings, process area(s), pipelines and other premises to be protected. By choosing a system which can integrate all types of detection as well as extinguishing, this will provide a significant reduction in the installation cost. The AutroSafe F&G detection system is being applied worldwide in one of the most critical industries, Petrochemical Oil and Gas. Part of the reason for this is that the system maintains a third party verification and certification according to IEC 61508. So how do we consider a communication channel or a detection loop to be safe or not? In installations like an LNG plant, a hazard and operability study (HAZOP) is normally done to identify and evaluate potential problems that may be a risk to people or equipment. This will help us determine what kind of equipment is required to protect the installation; however F&G equipment have different safety ratings that need to be examined as well. The reliability is important for the entire system and not only single components. A good standard for consideration of system availability and reliability is IEC 61508: Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems. This standard defines what is called Safety Integrity Level (SIL), an assessment of reliability, failure to safety (how safe the system is) and management/lifecycle considerations. The SIL tells us something about the probability of a failure on demand, i.e. how likely is it that the system functions as intended the day we actually need it? It can work 10 out of 10 times when tested, but that does not matter if it fails the next time it is supposed to detect a real hazard. Since we are talking about an entire system with dependencies, it is important that the entire system is evaluated according to this standard, and not only single components one by one. The entire system, from detection by one of the initiating devices to action by one of the outputs, should fulfil the requested level of safety (normally SIL2 is required for an F&G detection system). Always ask what testing has been done according to performance standards

Australian LNG Project In Australia, the system is just introduced and installed on a new LNG project. The project involves 435 kilometres of pipeline linking the gas fields to the main facility, and the construction of an LNG plant for conversion of the gas to LNG for export. The first stage of the project includes two LNG trains (i.e. processing units) with a design lifetime of more than 20 years. The production capacity is more than 8.5 million tonnes of LNG per year (expandable up to 12 million tonnes). FIRE STATION Fire station The LNG project is realized by having one AutroSafe F&G detection panel in each building. Due to the long distances between the buildings, all panels are interfaced via a redundant fiber optic network. The figure below shows how the panels interconnect with each other via two independent networks (for redundancy), and with centrally located panels in the Main control building, the Main substation building, and in the Fire station. MAIN CONTROL BLDG HMI MAIN SUB BLDG HMI Main Sub Bldg Control network (level 2) Client server network (level 3) Guard House GTG Control Cabins Common Facility Connectivity Server Inlet Air Chiller Inlet Air Chiller Fiber Optic Patch Panel Compressor Substation Compressor Substation Propane Condenser Bldg Warehouse Propane Condenser Bldg Maintenance Bldg Chemical Storage Operations Bldg Construction Bldg Loading Substation Jetty Guard house Marine Terminal Middle Eastern refinery AutroSafe IFG is also installed at a refinery in the Middle East, a setup which further explores the possibilities of the system. The refinery port is a combination of several self-contained buildings and modules; and all detection and extinguishing equipment are integrated into one AutroSafe F&G detection panel. This includes everything from traditional heat and smoke detection, manual call points, and flame & gas detection, to individual release of separate extinguishing zones inside each building. Early warning aspiration systems (HSSD) are also integrated into the same system (most often considered for local electrical equipment rooms). By combining all the panels into a single plant-wide network, one can easily monitor the entire plant from one or several locations. A simplified concept drawing for an installation like the Middle Eastern project is shown on the top of the page. The F&G detection panels interface all types of detectors and take appropriate actions. Communication to a plant-wide DCS is normally done via Modbus or by direct interpretation of the F&G systems communication protocol. In addition, local workstations are located in centralized control rooms and e.g. the local fire station. The function of a setup like this can be decided by the configuration data, as it can either be an independent self-contained system for each building or provide a distributed C&E across the entire plant. The entire system will fulfil a requirement for a SIL2 rating for the complete system. By using loops for all the field devices, we ensure that any break or short-circuit in the wiring will not influence the performance of the system. Even the flame and gas detectors can be protected from such faults by having them localized on a loop. In the solution above, the same two-wire loop also provides power to the detectors, which can translate to major savings when it comes to installation costs. F&G detection systems for LNG plants can be realized in different ways; most importantly, we need to consider the safety aspect of the solution. In order to properly accomplish this, we should examine the entire system with all intended functions (e.g. detection from a smoke detector through all communication pathways including the activation of an output module). Only by doing this, can we say something about how safe our system is, and if we are able to maintain the needed safety rating for the system. After all, it is the system performance on that day we need our system to perform 100 percent that becomes critical.

AutroPath Line-of-sight IR Gas Detection Line-of-Sight Infrared (LOS IR) Gas Detectors provide continuous monitoring of combustible hydrocarbon gas concentrations in a wide range (typically, 0 to 5 LFL-meters, over a distance of 5 to 120 meters). They must function under the heavy vibration typical of an industrial site and must endure harsh environments. Fire & gas safety in LNG Plants AutroTox Catalytic Combustible Gas Detection Our high-end AutroSafe Integrated Fire and Gas detection system provides innovative, flexible and integrated fire safety solutions that can easily be tailored to different applications and needs. The GT3000 toxic gas detector is an intelligent stand-alone industrial gas detector that provides continuous monitoring of the atmosphere for hazardous gas leaks or oxygen depletion. Reliable and proven solutions meeting today s strict requirements and standards within fire safety. vv Advanced technology simplifies service and maintenance, resulting in minimum downtime vv Cost-effective fast and easy access to spare parts, service and support vv Favorable terms and conditions for service and warranty agreements AutroPoint IR Hydrocarbon Gas Detection The AutroPoint family of point IR gas detectors lead the industry in quality, performance, and lowest cost of ownership.across the globe, optical IR gas detection is now the preferred detection technology for early warning of flammable hydrocarbon gas leaks. AutroSonic Acoustic Gas Detection The AutroSonic Acoustic Gas Leak Detector hears gas leaks that others don t the instant they occur. It is the first non-contact gas leak detector of its kind that recognizes unique sound fingerprints, analyzing 24 discrete ultrasonic bands, while ignoring nuisance ultrasonic sources. AutroFlame Multispectrum IR Flame Detection Prevent unnecessary costly operational shutdowns with the enhanced X33 Multispectrum Infrared Flame Detector. From refineries to turbines, offshore exploration/production to hangars, FPSOs to fuel storage, let the X33 protect your personnel, assets and property

What is SIL? Oil and gas installations around the world are becoming a safer place to work. We are bold enough to take some of the credit. For years we have been a preferred supplier of fire and gas safety systems in the petrochemical, oil and gas market throughout the world We make world class products, but believe that even the very best can get better. Appreciative of this, we continuously develop new products whilst providing safety to an entire industry, where thousands of lives depend on them every single day and night. SIL is short for Safety Integrity Level, followed by a number 1 to 4. It is a measure of functional safety for a given protective function, typically describing the level of safety protection needed for a specific function or process. SIL will give the reliability needed for the safety system. SIL1 is the lowest degree of protection, SIL4 is the highest. The target for a F&G detection system is typically SIL2. The goal is to know that a function will perform when needed, and if not, fail in a safe manner. A product claimed to be SIL rated or certified really depends on its use in a specific function. By this it is incorrect to refer to a certain SIL rating for an individual component as long as SIL applies to the complete function. When it comes to reliability SIL only counts for reliability of the system to perform its safety function. In modes considered to be less dangerous the system may fail more frequently. Service and maintenance Service and maintenance must be performed in accordance with local/national requirements. We recommend an annual service and control of the total system. For information on service and maintenance of the fire detection system and other equipment, refer to relevant procedures included in the installation and commissioning handbooks from Autronica. We recommend that you let us or one of out certified partners take care of the service. Then you lay your trust in the hands of people with training on and experience with our systems. This will ensure a longer life span of your system and increase the safety, thus reducing the life-cycle cost. Standards Local/national standards apply. Autronica Fire and Security Division Petrochemical, Oil & Gas Lagerveien 24 NO-4033 Stavanger +47 90 90 55 00 oil.gas@autronicafire.no www.autronicafire.com Approvals All our fire safety products are approved according to EN 54. For certificates, go to www.autronicafire.com.