I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

Similar documents
HRU ECO 4. user manual

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

HRU ECO 4 User manual

Itho CVE ECO 2 RFT. Installer/User manual

HRU ECO 4. installer manual

MODEL: BV400 Part No:

Thank you for choosing EnviroVent

November This product has been reconfigured Please read these instructions

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Operating Instructions

User and maintenance manual

20L Electronic Dehumidifier

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

MODEL: DC10RCDH / DC12RCDH

General Care and Safety Guide

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Installation and Operating Instructions MODEL: MSE46W

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Portable Air Conditioner

Slider hood Grey metal/stainless steel panel JLHDA601

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

BEFORE USING THE REFRIGERATOR PAG. 9 PROTECTING THE ENVIRONMENT PAG. 9 PRECAUTIONS AND GENERAL SUGGESTIONS PAG. 9

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

SLIDER CASEMENT AIR CONDITIONER

Wiring the fan correctly...

JLBIHD920 90cm Chimney Hood

ENG. IDEO 325 Ecowatt. Installation Manual

WHHR Midi & Midi Lite

Instruction Manual JLHDA cm Cooker hood

Cooker hood Stainless steel/curved glass JLHDA623

HOTLINE:

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

87cm. Cooker hood. Stainless steel JLCEILHD87. User guide

JLBIHD624 60cm Cooker Hood

Operating and installation instructions

Watch the heatsava video

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Inverter Split-type Room Air Conditioner

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System User / Homeowner Guide

Thank you for choosing EnviroVent

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Installation and Maintenance

Double Door - Dual Zone Wine Cooler

GB User and maintenance manual

HELPLINE If you have any difficulty with your appliance, do not hesitate to call us. Website

Stainless Steel and Glass Angled Extractor

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

GUH52SD 52 cm GUH75 75 cm Canopy Hood

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

MURELLE EV HE 25/55-30/55

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

15,000 BTU Portable Air Conditioner

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

GUH90 90 cm Canopy Hood

getting the best from your new cleaner...

Installation and Maintenance

AIR CONDITIONER ELECTRONIC CONTROL

PerformAir Profile bagged cylinder vacuum cleaner

HOTLINE:

ROTARY CONTROL AIR CONDITIONER

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

Thank you for choosing EnviroVent

DESICCANT DEHUMIDIFIER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Mira Sport Thermostatic

CERAMIC TOWER FAN HEATER PL2000

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

NEVER use a brush or push your fingers or metal objects down the slots. NEVER immerse your toaster in water. HINTS AND TIPS

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Local air conditioner

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

I - WHERE TO INSTALL THE PANEL HEATER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

OZX-300ST Ozone Generator

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Transcription:

I tho Advance Heat recovery ventilation unit User manual 226-0048/0111/ED 210.0998 A6_226-0048 Ventilator Advance ENGELS.indd 1 04-01-11 14:32

2

Contents 1. Introduction 4 1.1 Configuration 4 1.2 Itho conditions 5 1.3 Serial number, date of commissioning and scheduled service intervals 6 2. Safety 7 2.1 General 7 2.2 Liability of the user 7 3. Controller functions 8 3.1 Remote speed control hard wired 8 3.2 Remote speed control wireless 9 3.3 Frost protection 9 4. Commissioning 10 4.1 Manual potentiometers low- and boost speed 10 4.2 Middle speed 10 5. Trouble shooting 11 5.1 FAQ s 11 6. Maintenance 13 6.1 Cleaning 13 6.2 Filter replacement 13 7. Guarantee 14 Subject to changes without notice. No rights can be derived from this user manual. 3 ITho advance

1 Introduction Indoor air quality and energy efficiency are very important considerations in dwellings today. The Itho Advance Heat Recovery Ventilation Unit has been developed to meet these demands and offers controlled and better ventilation for a healthy and comfortable indoor climate in full compliance with current building regulations, while regaining the heat to an efficiency of up to 90%. For the home owner or occupant: This document explains the working principle of the ventilation system and how to operate and maintain this unit. Never switch off the ventilation, by disconnecting the power cord from the mains supply! (Except for service and maintenance intervals.) 1.1 Configuration The Advance has been developed for apartments and small houses with approximately 100-125 m 3 /h balanced exhaust and supply air volumes. It can be fitted as a wall, floor, or ceiling mounted unit for example in the space of a kitchen cupboard. Dimensions 597 mm width x 280 mm depth x 760 mm height. Note - Read this manual carefully. - Failure to follow these instructions may cause an adverse effect on your health. - Leave these instructions in the unit. 4

1.2. Itho conditions Itho does not accept any liability for damage caused by non-observance of the installation instructions. Service activities must exclusively be carried out by Itho or by suitably qualified competent persons using original Itho parts. 5 ITho advance

1.3 Serial number, date of commissioning and scheduled service intervals Serial number: Date of commissioning: Installers company name: Service call telephone number: Next service / filter replacement interval: 1) date 2) date 3) date 4) date 5) date 6) date 7) date 8) date 9) date 10) date 6

2 Safety 2.1 General Always disconnect the electric power cord from the mains, before you remove the motor part! - Do not use this appliance for functions other than those described in this booklet. - Never touch the appliance with wet or damp hands, or when barefoot. - Do not store inflammable products in the neighbourhood of the unit. - The unit is only suitable for 230 VAC/50Hz electric mains. - Never modify the fan or electronics by yourself. - Never plug in the power cord if the motor part is not placed into the unit. 2.2 Liability of the occupant / user - Cleaning or replacement of the filters in the Advance unit at the correct time. See chapter 6.2 Maintenance. - Cleaning the grilles in the rooms at regular intervals. Note: The grilles should always be placed back in their original location and position. If the grilles are changed or placed in a wrong position, the ventilation volumes will no longer be correct and the ventilation system might not work properly! - Always disconnect the electric power cord when carrying out any maintenance. Replace the filters on time Filter pollution could damage your health! 7 ITho advance

3 Description controller functions Your Advance heat recovery unit has been equipped with a high performance heat recovery exchanger, so there is no need to reduce the air volumes in order to thermal energy. However, reducing noise and saving electricity is also an important issue. You are able to switch the unit 3-speed: 3.1 Remote speed control hard wired (supplied separately) The speed selector switch does not require any maintenance. Manual speed selector: You are able to select a speed by hand: - Low (continuous). - Middle (extra comfort if there are more persons in the dwelling). - Boost (cooking and bathing). 1. Low (trickle). 2. Middle. 3. Boost. 8

3.2 Remote speed control wireless (supplied separately) The ITHO-RFT remote controller has been equipped with a long life battery type VARTA CR2032 Li-Mn 3V. Under normal circumstances the battery life time will be approximately 10 years. Every time you push the timer function button, the unit will be switched to boost speed for 10/20/30 minutes. After this time, the set speed returns automatically to the former speed. In case the former speed was Boost then the speed returns to low. RFT-wireless remote controller: You are able to select a speed by pushing button: Low (trickle speed). Middle. Boost. Timer function. 3.3 Frost protection Note: In case of very low outside temperatures for more than 24 hours, the fan motor will automatically switch off for several minutes to avoid a frozen heat exchanger! It will restart itself when the temperature has risen. 9 ITho advance

4 Commissioning The installer is responsible for commissioning the required air volumes rates for every room, in compliance with the current local regulations (for England and Wales this is the Domestic Ventilation Compliance Guide). 4.1 Manual potentiometers low- and boost speed Do not change the manual potentiometers on the Advance unit, it has been set by the installer in accordance to the required air volumes. 4.2 Middle speed Middle speed has been set in the controllers software by the manufacturer and cannot be changed. 10

5 Trouble shooting 5.1 FAQ s a. The fan has been switched off unexpectedly. - Mains voltage failure, check the Fuse Spur or in the distribution board cabinet/meter cupboard. - Plug in the power cord. - Frost protection active, wait for 120 minutes and the fan will be switched on. b. The unit makes a lot of noise. i. Gurgling noise coming out the unit. - The condensate trap below the unit has a too low water level, fill it up with water. - The flexible condensate hose is not completely in the condensate trap, push it deeper. ii. Rattling noise coming out the unit. - Fan motor fault, please contact your installer or service technician. iii. Swishing sound coming out of the grilles. - There is too much air pressure drop in the duct and grilles, clean both filters in the Advance unit and the grilles in the rooms and check if the grilles are in their original position. c. I want to switch off the unit at night. - Not possible, you also need fresh air during the night. d. Unpleasant smell. i. I smell the cooking in the whole house. - Air extract rates are too low, switch on boost speed at cooking time. - The filters are polluted, clean or replace both filters. - The grilles are dirty, clean all grilles. 11 ITho advance

ii. Near the unit. - Condensate trap below the unit is empty, fill it up with water. - The flexible condensate hose is not completely in the condensate trap, push it in deeper. iii. Near the supply air grilles. - The unpleasant air comes from outside, not a ventilation fault but to be sure, check and clean supply air filter. e. Too much condensation in the bathroom. - Too low exhaust air volume, switch on boost speed while showering or bathing. Check and clean filters and grille. f. Water leakage near the unit. - Condensate trap is clogged, clean it. - Condensate flexible hose is clogged or twisted, clean it and replace it into the trap. g. No speed change after pushing the button on the RFT remote controller. - Replace the battery in the remote controller (type CR2032 Li-Mn). h. If the problem persists, report the details to your installer or service technician! 12

6 Maintenance 6.1 Cleaning the Advance unit outside covers Keep the unit surface free from dust. 6.2 Filter replacement For the user, maintenance is limited to cleaning and replacing the filters. These will need to checked annually and either cleaned or replaced. This may differ per situation depending on environmental pollution from industry or traffic and also the activities in the house. A) Remove the plastic cover B) Remove the filter from the unit C) Clean the filter with a vacuum cleaner 13 ITho advance

7 Guarantee Warranty The Advance warranty is valid for 3 years after the installation date. Disclaimer This warranty does not apply to: - Disassembly and assembly costs. - Faults which are caused by incorrect treatment, negligence or accident. - Faults that have been caused by repairs by third parties without authorisation from ITHO-UK Ltd. If the appliance does not function correctly or a fault occurs, please contact your installer or service technician immediately. Ensure that only genuine spares are used for repairs. 14

Notes 15 ITho advance

Climate for life Itho strives at all times to offer people harmoniously together. We want a more with very little effort. You can recognise an enjoyable living and working comfortable and healthier living these solutions by the Itho Living Blue environment with its innovative solutions environment but at the same time, we label. Our aim is to develop climate in climate systems. These are solutions aim for lower energy consumption. systems that respect the world around for temperature, clean air and hot With sustainable technologies and us. Your wishes become our inspiration water in the domestic environment in innovations, Itho proves that seemingly and Itho works constantly to achieve which people and environment go opposite objectives can be combined this: Climate for life. 210.0998 A6_226-0048 Ventilator Advance ENGELS.indd 1 226-0048/0111/ED Itho UK Ltd 10 Faraday Court First Avenue Centrum 100 Burton on Trent Staffordshire DE14 2WX T +44 (0) 845 250 8090 F +44 (0) 845 250 8091 E info@itho.co.uk I www.itho.co.uk 04-01-11 14:32