EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

Similar documents
Heating with log wood

Heating with wood pellets kw

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

English. Efficiency. HERZ pellet boiler with condensing technology. ɳ over 106% COndEnSATiOn

HERZ ECO-Line Heating with logs or wood pellets

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

JÄSPI Solid Fuel Boiler

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Forward-looking and energy effi cient Biomass heating

PVE SERIES POWER VENTER SYSTEM MANUAL

6/8 burners gas range on gas oven

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Pellet stoves. contemporary design. for a new destination.

Aquaflam Wood boiler stoves and fireplace inserts

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

FLUIDIZED BED BOILERS

AIEA Presentation. Wood pellets heating systems.

Manual and installation instructions. Function. Operating phase

Solid biofuel solutions

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

<< >> Condensing technology at the service of oil. Controlling energy to save money

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Boiler Technical Specifications (2013)

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Operating and installation instructions for Fire Lotus H586

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Cassette inserts and fireplace doors

With its particular heat retencion capacity, cast iron is the perfect

Installation and maintenance manual

Installation & Manual. Model T-25

Gas-Fired Unit Heaters Commercial & Industrial

MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

Pioneers of heating with biomasses

HIGHLANDER Wood and Multi-fuel Stoves

Rozp.UE2015/ kw kw

P-10. Stûv P-10 pellets P-10. A new vision on fire

the heating technology ecofire Pellet burning stoves range hydro

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Biomass. Biomass solid fuel boiler range

Multi Fuel Heating Solutions for Every Home. A Cast Iron Masterpiece

SFA Guide to Building Regulations and Solid Fuel Heating

WOOD CHIP HEATING HPK-RA

Combined boiler. for solid fuel and pellets

Light oil / kerosene burner

Masterflamme Convection Wood Stoves Perfect combustion with unique design

Heating and Energy Saving Systems pellet biomass wood solar energy gas oil

Solid Fuel Range Cookers and Stoves Catalogue KVS MORAVIA

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

POWER VENTER. Model: PVE Series

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Eco Angus Wood Pellet Boilers

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Operating Instructions

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Installation and Operating Manual

PELLET BURNER PV 350

English. Heating with logs & wood pellets 20-40

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Sauna Heater. Installation and Manual

USER MANUAL 9kW LILLY PELLET STOVE

P4 Pellet. Pellet boiler. P4 Pellet.

SAEY 92 (TOP) WOOD/COAL

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

AIREX 2S WOOD PYROLYSIS SUCKING FAN

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Easyfire Standalone biomass pellet boiler

"NP" & "RG" AIRFLO. In-duct firing line burner

INSTRUCTIONS FOR USE & MAINTENANCE MANUAL CUATRO Wood-burning appliance. Barbas wishes you many cosy evenings with your new appliance

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

WOOD CHIP HEATING HPK-RA

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

Planning and installation guide HDG Compact 50/65 with HDG Hydronic

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Fireplace LUCY 14 SLIM right BS

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Your guide to. Biomass Heating Systems

Wood Chip and Pellet Boilers. Turbomat TM 500.

INFRARED RADIANT HEATERS

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Installation instruction

INTEC Engineering GmbH Energy systems

NEW LINE BOILER CONTROLLERS

HEADLINE LOREM IPSUM COMPANY EFFICIENCY

USERS MANUAL FOR GAS BOILERS

Heating with wood the most natural fuel in the world

Light oil - kerosene burner

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

Transcription:

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L Chopped wood Chips/sawdust Wooden pieces Chip briquettes.. the useful and economic alternative to oil, gas and electricity Your benefits Snort heat-up times Heating using advanced hot-air technology Inexpensive procurement costs fast payback Low maintenance More than 70 years experience in stove design

Hot-Air Heating Systems from EWI-THERM Heating systems made by EWI-THERM are based on state-of-the-art, advanced hot-air technology. Their significant benefits facilitate the decision for low-cost heating and disposal. By using hot-air heating systems, rooms of almost any size can be heated in a fast, effective and environment-friendly way. Heat-up occurs from zero, as the energy is supplied directly and without any detours to the room air. Long start-up times or energy loss due to heat transfers to intermediate fl uids, such as water, are avoided. Thanks to the short heat-up time, energy is only produced when required. In connection with the automatic charging system, the heating can also be operated over night and the heating output can be minimized. Why do you not heat operating fl oors quickly and easily with wooden remainders from your own workshop and save expensive fuels such as oil or gas? Too inconvenient? Certainly not. We have continuously further developed our technology. As a result, the desired room temperature, for example, can be simply adjusted through the room thermostat. Even when the furnace was regulated down through the thermostat, i.e. with minimum energy output, the advanced control system ensures an effi cient, extremely clean and smokeless combustion. Very high effi ciency, effective fuel utilization, robust design, simple operation and the proven compliance with the legally prescribed limit values according to the 1st German Federal Immission Control Act (1st BImSchV) make EWI-THERM hot-air heating systems to a top product of hot-air technology. We can guarantee compliance with the limit values, even if they become more stringent! Is this possible with any other hot-air heating system? EWI-THERM hot-air heating system, type Optimal VII. Heating output up to 198 kw, designed for rooms up to 5,600 m³ (as per DIN). Fully automatic control of the hot-air heating system and the EWI-THERM silo discharge

EWI-THERM hot-air heating systems are future-proof. This is confirmed by the legislative bodies and the responsible trade supervisory authorities. Wooden remainders represent raw materials that can be utilized in an economically and ecologically reasonable manner. The prerequisites are: A. Wooden remainders, such as saw dust, chipboard residues or wooden pieces in a sufficient quantity. B. A technology that converts almost the whole combustion material to energy according to the principle of wood gasification and consequently enables a smokeless, extremely low-emission combustion in compliance with the limit values stipulated by 1st BImSchV. C. Previous coordination with the responsible district chimney sweep master about the combustion system to be installed TÜV Rheinland (Rhineland Technical Inspection Authority) confirms that all EWI-THERM hot-air heating systems of the series Optimal-E II VII are allowed to be fired with combustibles of Category 6 (painted, lacquered or coated wood, as well as its wastes without halogenorganic compounds and without a wood preservative) and combustibles of Category 7 (plywood, chipboards or other glued wood as well as its wastes without halogen-organic compounds and without a wood preservative) in compliance with the German Federal Immission Control Act.* Dusts of any type are not suitable for combustion, since they might cause deflagration *German Environmental Law EWI-THERM hot-air heating, types Prestige SE or Optimal-E 0 to VI. Heating output from 25 to 170 kw, suitable for rooms from 350 to 4,800 m³ (according to DIN). Your advantages over hot-water heating systems: 1. Immediately available heat 2. Short heating-up time as opposed to water 3. Air does neither boil nor freeze 4. No water damage caused by pipe fracture or other leaks 5. Considerable saving of space and free wall surfaces since no radiators are necessary 6. Favourable acquisition costs, no buffer storage required 7. Quick and reasonably priced assembly 8. Up to 94% absorption of dust thanks to state-of-the-art filter technology 9. No circulation of dust caused by radiators 10. Fast payback due to saving of energy and disposal costs or overcharged heating systems

Design The practical and benefi cial hot-air heating systems are easy to install even under diffi cult space conditions. The robust and durable design withstands maximum stress. In addition to the safe function and the hazardfree, simple operation of EWI-THERM hot-air heating systems, their overall weights are also an important quality feature of great signifi cance. Thanks to the modular design of EWI-THERM hot-air heating systems, their individual components can be assembled locally and easily replaced or adjusted to the specifi c requirements. All models are available for left and right installation. This means that the cleaning openings that must be freely accessible are either arranged on the left or on the right side (viewed from the shell). The components and their features: Combustion chamber The two-section combustion chamber with 6-12 cm thick fireproof special fireclay lining and cast-iron fire and/or soot door is designed for an operating temperature of up to 1,200 C. These high combustion temperatures permit the use of combustibles of Categories 6 and 7, ensuring compliance with the German Federal Immission Control Act (BImSchV). Shell Due to its large volume and the double-type lock prescribed by the Employers Liability Insurance Association, the shell ensures a secure, time-saving and convenient charging. The shell meets the requirements of the Employers Liability Insurance Association for charging systems according to ZH 1/472. Hot-air blower The double-side intake, powerful radial blower with external motor and V-belt drive guarantees a high hot-air capacity. Induced-draught fan with flue pipe connection The induced-draught fan guarantees a uniform combustion and is automatically regulated up or down, as required, through a frequency converter. The connecting piece of the flue pipe must be attached to the chimney at an angle of 45.

Heat exchanger with dedusting system A large-sized heating element made of 2 mm thick steel is surrounded by thick-walled cast plates as per DIN 1691 and permits the rapid transmission of combustion energy into hot air (efficiency 88 91%). The integrated flue gas dedusting system ensures compliance with the legally stipulated emission limits for fine dust in the flue gas. Automatic control system The heating system is equipped with a technically mature, fully automatic control system that controls all operating procedures harmoniously. Taking advantage of the technical progress and our longstanding experience in the design of heating systems, EWI-THERM hot-air systems are continuously improved. Each of our hot-air heaters can be adjusted to the specific operating conditions and the local situation by employing the advanced PLC technology (Programmable Logic Control). The temperature that makes you feel comfortable (room temperature) can be individually adjusted through the integrated display on the front side of the control cabinet. The flue gas temperature can be precisely adjusted and set according to the existing chimney type. The hot-air temperature can be increased according to the length and the routing of the hot-air line in such a way that the blown-out heat at the outlet is still sufficient. Overheating protection If combustibles such as chip briquettes or chipboard residues were used in previous heating systems, there was a risk of furnace overheating and consequential damage. In addition, this caused the expensive closing of the fire dampers. Thanks to the control system, these disadvantages can now be easily counteracted and reliably excluded in the future. Speed of the induced-draught fan at low-load conditions In order to achieve uniform low-emission combustion even under unfavourable draught conditions posed by the existing chimney, the speed of the induced-draught fan can be adapted accordingly and precisely adjusted. The actual conditions of the relevant points can be called up on the display and easily adjusted, if necessary. If combustible charging to the furnace stops, the furnace will automatically be stopped ensuring that all safety requirements are met. Another benefit of our hot-air heating systems becomes evident during the hot summer months. In this case, the hot-air blower can act as a fan to provide a pleasant cooling effect.

Dimensions Types Prestige-SE and Optimal-E, Sizes 0 to VI Type Optimal Size VII

Type Prestige-SE Optimal-E Model SE 0 I II* III IV V VI VII Rated heat output KW 25 34 45 58 87 116 145 170 198 3 For rooms as per DIN up to m 350-600 500-850 650-1100 800-1450 1200-2200 1500-2900 1800-3800 2300-4800 2700-5600 kg/h 8-10 10-12 12-15 15-25 25-30 30-35 35-40 40-50 50-60 3 Blower capacity, free-blowing m /h 1450 2200 3250 4000 6000 7500 9400 14000 20000 Weight kg 550 900 940 1200 1250 1600 1700 1800 3000 Hot-air blower kw 0.49 0.55 0.75 1.1 1.5 2.2 2.2 3.0 1.5 / 4 Induced-draught fan kw 0,37... Prestige-SE 230V, supply cable 3 x 2.5 mm², fuse rating 16 A... Optimal-E: 0 to VII 400V, supply cable 5 x 2.5 mm², fuse rating 16 A Shell capacity depending on overall size l up to 240 Total length A mm 1500 2055 2055 2255 2255 2600 2600 2600 3500 Total width B mm 570 830 830 930 930 1020 1020 1020 950 Total height without water module C mm 1570 1990 1990 2120 2220 2320 2450 2750 2800 Hot-air outlet Ø D mm 300 350 400 450 550 600 700 700 750x750 Length of induced-draught fan E mm 500 530 530 550 550 620 620 620 Flue pipe Ø F mm 150 150 150 180 200 220 220 250 250 Filter box height G mm 700 1000 1000 1000 1000 1200 1200 1200 Height up to lower edge of flue pipe nozzle H mm 1080 1400 1500 1620 1700 1740 1900 2250 Height up to hot-air hood I mm 1440 1870 1870 1990 2100 2190 2350 2700 Height of the lower section J mm 600 750 750 750 750 750 750 750 1000 Filter box depth K mm 380 615 615 615 615 760 760 760 Shell projection L mm 370 450 450 450 450 500 500 500 400 Height up to lower edge of shell M mm 1230 1500 1500 1500 1550 1700 1700 1700 Filling depth N mm 250 400 400 400 400 400 400 400 400 Length of lower section O mm 800 1000 1000 1200 1200 1400 1400 1400 3100 Hot-water heating module (optional) P mm 300 300 300 300 300 300 300 300 Hot-water heating module (optional) Q mm 840 1040 1040 1240 1240 1440 1440 1440 Hot-water heating module (optional) R mm 580 680 680 780 780 880 880 880 Height up to lower edge of filter cabinet S mm 300 300 300 300 400 400 400 400 1650 Shell width T mm 370 480 480 480 550 550 550 550 550 Height up to filling edge of shell U mm 1220 1500 1500 1550 1550 1720 1720 1720 * Overall size II-S with 48 kw has the same design as Size II. Further sizes are available on request.

Sectional View of the EWI-THERM Hot-Air Heating System 5 17 4 16 6 3 2 1 7 18 15 8 14 13 10 9 11 12 1 Shell 2 Flue gas dedusting system 3 Smoke collection hood 4 Hot air outlet 5 Flue gas inlet 6 Induced-draught fan 7 Hot-air blower 8 Return-air filter housing 9 Fire bridge 10 Post-combustion chamber 11 Ash chamber (ash drawer) 12 Ash door 13 Fire door 14 Combustion chamber 15 Shutoff device / double lock 16 Thermocouple hot air 17 Thermocouple flue gas 18 Thermocouple room air

Prerequisites for the installation of an EWI-THERM hot-air heating system 1. Chimney with a cross section matching the heating system size. 2. Sufficient supply of combustion air. 3. Unobstructed return air path. 4. Complete wiring between control system and furnace by specialized electrical contractor. 5. For systems with a heating output of more than 50 kw, an enclosed heating room is required. Operation of the EWI-THERM hot-air heating is very easy: 1. Charging the combustion chamber with combustibles through the shell. 2. Switching on the automatic control system. 3. Ignition of the combustibles through the fire door. 4. If the flame becomes visible through the sight window at the side, the furnace can be fully charged. Combustion is controlled by opening the primary and secondary air supply at the lower furnace section in correspondence with the combustible material used. Maintenance is limited to the cleaning of the air filters, the flue gas dedusting system, the heat exchanger as well as the combustion chamber and ash drawer. Due to the high combustion efficiency, an extremely low quantity of ashes will remain in the furnace. The cleaning of the air filters depends on the dust content in the conveyed air. An inexpensive service contract will guarantee a long-term operation of the hot-air heating system. Optional EWI-THERM hot-water heating module The EWI-THERM hot-air heating system can be additionally and/or subsequently equipped with a hot-water heating module. This permits the generation of hot air for the workshop area and, in parallel, the generation of hot water for use in office, staff and other rooms. The hot-water heating module represents an air/ water heat exchanger. Hot air that flows through the lamella at approx. 60-70 C, heats the water which can then be used to support, for example, an existing hot-water heating system. The module can be designed up to one third of the overall heating output. In analogy to solar modules, the hot-water heating module can be integrated into and support existing oil and gas heating systems. As long as wooden waste is burnt and hot air is produced, hot water can be withdrawn. Your benefits: 1. No boiling water 2. No buffer storage required 3. Simple, and even subsequent, integration into existing heating systems 4. No additional operating costs 5. Inexpensive procurement 6. Fast installation

Application Example Hot-air heating systems

The picture shows an EWI-THERM hot-air heating system with additional components such as silo discharge system and hot-water heating module, as it could be employed in your facilities.

Heating with EWI-THERM EWI-THERM silo discharge system the useful and economic alternative to oil, gas and electricity Fast and economic heat by using renewable energies and combusting fi rewood, wooden waste, brown coal briquettes, etc. Capacities from 6 kw to 250 kw Suitable for all rooms from 50 m³ to 10,000 m³ The EWI-THERM product range: EWI-THERM hot-air heating systems for capacities from 25 to 250 kw, greater capacities on request. We will be pleased to submit a tailor-made quotation. EWI-THERM heating for side grain fi ring, from 150 to 250 kw EWI-THERM slow combustion stoves, from 6 to 15* kw (*with ring-type radiator) EWI-THERM silo discharge system EWI-THERM heat exchangers EWI-THERM special steel chimneys EWI-THERM fl ue gas dedusting system EWI-THERM air ducts EWI-THERM slow combustion stoves Fast heat Economic and durable Excellent effi ciency Environment-friendly due to CO2-neutral combustion No offi cial approval required as per 4 of the 1st German Federal Immission Control Act Type-tested in compliance with CE or DIN 18890 EWI-Therm heating for side grain firing TYP H-F-L for the combustion of wooden pieces up to a length of 1.20 m EISENWERK WINNWEILER Ludwig Krämer KG Manufacturer of equipment, units and systems in the field of air and heat technology D 67722 Winnweiler, Industriestraße 3 D 67719 Winnweiler, P.O. Box 1152 Phone: 0049 (0) 6302 / 60 99 20 + 78 55 + 78 56 Fax: 0049 (0) 6302 / 78 83 E-Mail: info@ewi-therm.de www.ewi-therm.com EWI-THERM products are available from: Herewith all previous information and data become invalid. We expressly reserve the right of changes in terms of technical progress. The product photos represent application examples. The quoted and installed heating systems are assembled individually according to the relevant requirements and may deviate from the designs shown in this brochure. The planning and design of all furnaces and accessories are subject to copyright protection. Status 3/2010