Dräger GS01 (wireless) Detection of flammable gases and vapours

Similar documents
GS01 (wireless) Detection of flammable gases and vapours

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger REGARD 3900 Series Control System

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Detection of carbon dioxide

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger REGARD -1 Control System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

The SharpEye 40/40I (IR3) Flame Detection

Dräger X-zone 5500 Area Monitoring

Training Gas Detection Level 3 Maintenance and Repair

Dräger Pac 5500 Single-Gas Detection Device

On-site & Shutdown Safety Service CSE Monitoring

Training Gas Detection Level 2 User and Calibration. Basic Information

Training Authorised Gas Tester Level 1. Basic Information

Dräger QuadGard Control System

Dräger Bump Test Station Calibration and Bump Testing

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Flame 5000 Flame Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger X-am 2500 Multi-Gas Detection

Dräger X-pid 9000 / 9500 Multi-Gas Detection

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger Configuration and Evaluation Software

Dräger PEX 3000 Flammable Gas Detection

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Pac 3500 Single-Gas Detection Device

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Bodyguard 1000 Warning Device

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger X-am 2500 Multi-Gas Detector

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger VVP 1000 System Components

Dräger Flame 5000 Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Portable wet chemical extinguishers

Dräger X-am 5000 Multi-Gas Detection

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger Flame 2100 (UV) Flame Detection

Powder Extinguisher ABC - composite Portable powder extinguishers

The SharpEye 40/40R (IR) Flame Detection

Dräger Pac 7000 Single-Gas Detection Device

Dräger Pac 6000 Single-Gas Detection Device

Dräger REGARD -1 Control System

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Pac 8500 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detector

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Foam Wheeled Extinguisher AB Movable fire extinguishers

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

Dräger Flame 2100 Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger Flame 2500 Flame Detection

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger REGARD -1 Control System

Dräger OR Lights Simply good light

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger PIR 7200 Toxic Gas Detection Transmitter

VarioVac vacuum regulators Consumables and Accessories

Tropic 2.0 ultrasonic nebuliser

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Dräger Polytron 8310 Stationary gas detector (DSIR)

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

D Moving beyond telemetry INFINITY M300

Dräger X-am 5000 Multi-Gas Detection

Oxylog VE300 Emergency & Transport Ventilation

Dräger P4000 Pressure and Leak Testing

Dräger UCF 7000 Thermal Imaging Camera

Oxylog VE300 Emergency & Transport Ventilation

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Pac 3500 Single-Gas Detection Device

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Transcription:

Dräger GS01 (wireless) Detection of flammable gases and vapours The Dräger GS01 is a wireless infrared gas transmitter for continuous monitoring of flammable gases and vapours in the oil and gas industry The intrinsically safe and SIL-rated transmitter features completely wireless signal transmission and power supply This makes it ideal for reaching difficult-to-access measuring points, while also significantly reducing installation costs Infrared sensor with MEMS technology, ultrasound sensor to support the low-power operation Radio antenna with a range of up to 500 m D-42775-2015 Rugged stainless steel case with assembly Battery operating time up to 24 months

02 Dräger GS01 (wireless) Benefits Installations in demanding conditions On offshore platforms or FPSOs, at tank farms and refineries - safety-related measuring points are everywhere in the oil and gas industry Some of these measuring points are extremely difficult if not impossible to monitor using wired gas detection devices In contrast, the GS01 wireless transmitter requires no cable installation, either for signal transmission or for its power supply As such, installation is easy and uncomplicated and the transmitter sends its signal to the access point up to 500 metres away No alignments are required for the power supply or for signal transmission Plus, the GS01-EA product variant with separate antenna can be installed inside machines or buildings where signal transmission is impossible due to shielding For temporary applications, such as maintenance work on petrochemical plants or exploratory drilling, the GS01 offers you maximum flexibility It can be seamlessly integrated into your existing safety features Even technically complex installations, such as on the rotating tower of an FPSO, can now be carried out without hassle Saving time and money during installation The costs of installing the GS01 are 60 to 80% lower than those for wired transmitters Wireless communication and power supply decrease the need for cables, docking stations and control cabinets, but also considerably reduce the work involved in installation In addition, less input is required for planning, configuration and documentation of the system This is made possible by the intelligent design of the GS01 The transmitter runs on less than 5 milliwatts of power That means you can operate it for up to two years without having to change the battery, depending on environmental conditions The intrinsically safe construction also allows for trouble-free battery-pack replacement, even in potentially explosive atmospheres Saving time and money during operation The long-term stability of the GS01, due to the Micro Electromechanical System (MEMS), eliminates re-calibration, which directly reduces your maintenance costs The microelectromechanical system guarantees extremely failsafe infrared-optical detection This takes place on three different wavelengths and includes heated optics to prevent condensation in the sensor As a result, false alarms are significantly reduced Familiar, reliable transmitter Wired or wireless, Dräger always demands high quality when it comes to the construction and measuring quality of its transmitters The SIL2-capable GS01 uses the ISA10011a wireless standard, which ensures that the signal chain is fully SIL2-capable Furthermore, the ISA10011a standard enables simple integration of your additional wireless field devices into the existing communication network Additionally, the high-speed, secure transfer of measurement data through the patented SafeWirelessTM communication system adds to the overall safety of your facility

Dräger GS01 (wireless) 03 Presenting a Dräger GS01 System The Dräger GS01 transmits its detection signal wirelessly to the access point From there, the signal is transferred to the gateway This feeds the control unit directly via Modbus or with the PROFINET protocol For analogue analyser units, a D/A converter can alternatively be used System Components Yokogawa Access Point The Yokogawa access point enables the user to access the wireless ISA10011a network This product is manufactured by the company of Yokogawa D-11979-2017

04 Dräger GS01 (wireless) System Components Yokogawa Gateway The Yokogawa gateway manages the wireless ISA10011a network This product is manufactured by the company of Yokogawa D-11980-2017 D-11978-2017 Phoenix 4-20 ma Converter The Phoenix 4-20 ma converter is a digital-analogue converter for connecting to control units with convential 4-20 ma input channels This product is manufactured by the company of Phoenix Accessories External antenna The external antenna allows the Dräger GS01-EA to be used even if radio transmission is restricted, eg by a Faraday cage D-996-2016

Dräger GS01 (wireless) 05 Accessories Sun and weather shield The sun and weather shield protects the Dräger GS01 from direct sunlight and adverse weather conditions D-11973-2017 Services Product Service Our product service department supports you with a range of service packages in our shops or on site in your plant Care, servicing and maintenance are key factors when it comes to safety Diligent maintenance and care is also absolutely necessary from an economics perspective Preventive checks, service procedures and original replacement parts make your investment last longer D-2335-2016 D-2331-2016 Training The Dräger Academy has imparted well-founded and practical knowledge for over 40 years With over 110 authorized trainers and more than 600 available topics, we conduct more than 2,400 training sessions per year We equip your employees with the knowledge required for real-life situations and ensure that the learned material can be recalled and applied reliably in their everyday work and especially in stressful situations To meet your needs, we are also happy to develop a customized training program specifically for you

06 Dräger GS01 (wireless) Related Products Dräger Polytron 8700 IR D-14983-2010 The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit (LEL) It uses a high performance infrared Dräger PIR 7000 sensor, which will quickly detect most common hydrocarbon gases Besides a 3 wire 4 to 20 ma analogue output with relays, it also offers Modbus and Fieldbus making it compatible with most control systems Dräger PIR 7000 The Dräger PIR 7000 is an explosion proof point infrared gas detector for continuous monitoring of flammable gases and vapours With its stainless steel SS 316L enclosure and drift-free optics this detector is built for the harshest industrial environments, eg offshore installations ST-11659-2007

Dräger GS01 (wireless) 07 Technical Data General Performance Electrical Data Communication Environmental Conditions Housing Approvals Measuring principle Detectable gases Calibration Response time Accuracy Zero-point stability Battery type Average power Battery lifetime RF power Type Protocol Gateway output Operating temperature Infrared single beam, triple wavelength ATEX / IECEx: FM: Factory-set, no field calibration 5 seconds 0 to 100 % LEL (Methane, Propane) 0 to 100 % LEL (Methane) 0 to 80 % LEL (Propane) ±3 % LEL or ±10 % of measuring value, each the higher value (refers to Methane) ±3 % LEL (lifelong) Lithium-Thionyl Chloride 5 mw Up to 2 years (depending on the environmental conditions) GS01: <12 dbm EIRP GS01-EA: <16 dbm EIRP IEEE802154 in 24 GHz ISM Band ISA100 Wireless Standard: Modbus TCP/RTU, OPC Optional: PROFINET (SIL2) Storage temperature -40 C to +65 C Humidity Protection Class Dimensions Weight Mounting ATEX / IECEx FM Safety Integrity Level PROFINET is a registered trademark of PROFIBUS and PROFINET International (PI) The ISA100 Wireless TM is a trademark of ISA100 Wireless Compliance Institute -30 C to +55 C (if higher temperature ranges up to +65 C are required please contact Dräger) 0 to 100 % RH IP66 and IP67 300 x 110 x 170 mm 28 kg (incl Battery) With bracket for 8 mm or 5/16" bolts II 2G Ex ib IIC T4 Gb (-30 C bis +55 C) Class I, Zone 1 AEx ib IIC T4 Gb (-30 C bis 55 C) Class I, Div 2 Group A, B, C, D (-30 C bis 55 C) SIL2 EN 61508, Ed20 Ordering Information Dräger GS01 wireless IR Gas Detector Dräger GS01 wireless IR Gas Detector FM Dräger GS01-EA wireless IR Gas Detector-5m Dräger GS01-EA wireless IR Gas Detector-5m FM Dräger GS01-EA wireless IR Gas Detector-10m Dräger GS01-EA wireless IR Gas Detector-10m FM Dräger GS01-EA wireless IR Gas Detector-20m Dräger GS01-EA wireless IR Gas Detector-20m FM Dräger GS01 Battery pack (without cells) Dräger GS01 Battery pack FM (without cells) AL20700 AL20735 AL20715 AL20737 AL20716 AL20738 AL20717 AL20739 AL20712 AL20713

08 Dräger GS01 (wireless) Ordering Information Dräger GS01 Battery cell type SL-2780/S Dräger GS01 Battery cover Dräger GS01 Weather cap Dräger GS01 Serial adapter Dräger GS01 Sunshade / weather protection AL20706 AL20708 AL20709 AL20710 AL20711 Not all products, features, or services are for sale in all countries Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released Go to wwwdraegercom/trademarks to find the current status 9104347 1707-2 HQ PP Subject to modifications 2017 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom REGION DACH Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION EUROPE Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draegercom REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom REGION ASIA PACIFIC Draeger Singapore Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom Locate your Regional Sales Representative at: wwwdraegercom/contact