Hotflo. Unvented point of use hot water

Similar documents
Unvented water heating

Multipoint. Unvented point of use hot water

Amptec. Electric flow boiler

Cistern-fed water heating

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Streamline. Vented point of use hot water

Combined electric boiler and domestic hot water store

Multipoint Technical Data

2015 PRODUCT RANGE GUIDE

Unvented water heating

Handy Dri / Hair Drier

Electromax. Combined electric boiler and domestic hot water store

Ventilation Product range ADVANCE ECO 4 ECO 2

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

MEGAFLO HE Iss 1

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

VENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Hand Hygiene. September 2015 EV Instantaneous Handwash

HOTFLO 10 / 15. Fitting Instructions and User Guide

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Installation and User Instructions HS10U, HS15U.

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

HOTFLO 10 / 15. Fitting Instructions and User Guide

Unvented Water Heating. Zircon

Unvented Electric Water Heater 10/15 litre Undersink

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Megaflo eco Unvented hot water cylinders

Water. Heating. Connect with the Best. Electric Showers Power Showers 324. Shower Pumps 324. Beverage Water Dispensers

Cylinders & Water Heaters

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Exceeding the Standard

Exceeding the Standard

MULTIPOINT SS H 50/80 & 100

Streamline Undersink. Fitting Instructions and User Guide

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Megalife Solar Vented Cistern Fed Water Heater Installation manual

Stored Water District Heating Interface Units. Heat Interface Units

Series 1000 & Storage Water Heaters

Megaflo eco. Unvented hot water cylinders

Megalife Vented Cistern Fed Water Heater Installation manual

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

MULTIPOINT 30 & 50 Litre

Water Heating Systems

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Solar thermal domestic hot water system

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

SUPREME 140, 155, 170

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SMART HOT WATER SOLUTIONS PRODUCT RANGE

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Express 50 Litres Installation, operation and maintenance manual

OPEN OUTLET TAPSETS. Fitting Instructions and User Guide

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

Installation & Technical Guide. Domestic & Commercial.

For latest prices and delivery to your door visit MyTub Ltd

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

MEGAFLO Eco MEGAFLO HORIZONTAL SHRU IZI. MEGAFLO 1 Product 16 Guide INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SEALED THERMAL STORE

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

maximise the sun s energy with warmflow solar Warmflow Solar

Regulations, Legislation and Byelaws

ADVANCE ECB ELECTRIC COMBINATION BOILER

HI-MAX INSTANT Indirect HIU First Fix Rail / Stand-off Kit Fitting Instructions

Total Hot Water Solutions

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Fitting Instructions and User Guide

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Fitting Instructions and User Guide

Powerflow Unvented water heater

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Instructions & Maintenance

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Summer Works Scheme 2010

THERMOSTATIC SHOWER VALVE

Cylinders - Vented Water Heaters - Electric Water Heaters - Domestic 314

Packaged Solutions. Basic Packages

Unvented Direct & Indirect Hot Water Cylinders (400L L)

CUBEflow Thermal Store Tank

UNVENTED WATER HEATERS. Water Heater Display Stand

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Transcription:

Unvented point of use hot water

We developed the range for people who need a hot water supply for two to three basins or sinks. Flexible siting is a key design feature that we insisted upon because it means there is no requirement for a cold water cistern. can be used with standard or mixer taps and fed from the mains water supply provides high hot water flow rates. With the best possible performance, long-term reliability and corrosion-resistance in mind, our designers specify high-grade copper for the s inner container. Using copper for this key component also means we don t have to fit a sacrificial anode avoiding the need for the hassle and expense of regular inspections and replacement. In addition, copper is better than lower grade materials at withstanding shock and vibration during delivery, installation and maintenance. The complete confidence we have in the quality of s design and materials is proven by its two year guarantee with on-site service support. 2

Available in (suitable for up to two basins) and 15 litre (suitable for up to three basins) capacities.* kw element rating. Replaceable copper inner container with integral heating element. Two year guarantee with on-site service support. Externally adjustable thermostat from 10 C to 70 C. CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene. Element On indicator. No anode to inspect or replace. Suitable for use with any standard tap or mixer. Fitted with 1 metre of 3-core cable. Comprehensive installation instructions. Pressure relief supplied with all models. IPX4 rated. Kiwa approved to UK Water Supply Regulations. CE marked. * Figures are for guidance only, the Heatrae Sadia Specification Advice Team should be contacted to discuss requirements for specific sites. Capacity recommendations are based on BS 6700. 3

Accessory selection guide A key factor in the selection of accessories is the maximum incoming water pressure at a particular location. In instances where this is not known, installers are recommended to consult the local water authority for more precise information. When fitting small unvented water s it is important that, where necessary, the correct accessory packs are fitted to suit local conditions. For assistance in their selection and fitting, consult the following guide. To provide an added level of safety, Heatrae Sadia recommend the fitting of a temperature and pressure relief on s of 15 litres and below, although this is not required under the latest British Standards. Diagram 1 For inlet water pressure up to 4.1 bar (60psi). Hot Cold or 15 litre Pressure relief T piece To drain (waste) 2.8 (10 l) or 4.2 (15 l) metres is required for expansion in pipework Nearest cold draw-off Service Cold mains feed Can expanded water be accommodated in the pipework without hot water entering any supply pipe to which a cold water draw-off is connected? (i.e. at least 2.8m of 15mm pipe for unit and 4.2m for 15 litre unit) YES NO Diagram 2 For inlet water pressure up to 4.1 bar (60psi) where expansion down the mains is not possible. Hot Cold Pressure relief (expansion) Expansion vessel Check Nearest cold draw-off Service Are there any check s, stop s with loose jumpers or fittings that prevent reverse flow? or 15 litre T piece To drain (waste) Cold mains feed NO YES Diagram 3 For inlet water pressure over 4.1 bar (60psi). YES Is mains pressure 4.1 bar or less? NO YES Is mains pressure 4.1 bar or less? NO Hot Cold Pressure relief (expansion) Expansion vessel Check Nearest cold draw-off Pressure reducing Service Is temperature and pressure relief specified? Is temperature and pressure relief specified? Is temperature and pressure relief specified? Is temperature and pressure relief specified? or 15 litre T piece To drain (waste) Cold mains feed Note: If pressure reducing is used, expansion down the mains is not possible. YES NO YES NO YES NO YES NO No packs required Diagram 1 U1 + U5 Diagram 3 Fit pack U5 Diagram 2 U1 + U5 Diagram 3 Diagram 4 Temperature and pressure relief. For use with diagrams 1-3 above. Temperature and pressure relief Hot Cold To drain (waste) Fit pack U6 Diagram 4 U1, U5 + U6 Diagrams 3 + 4 U5 + U6 Diagrams 2 + 4 U1, U5 + U6 Diagrams 3 + 4 or 15 litre 4

Accessories A full range of accessories are available for installation with 10 and 15. These are supplied as accessory packs. When installing small unvented water s, it is essential that the correct accessory packs are used. The selection guides on page 4 indicates the appropriate pack(s) for different s and situations. If the expansion in the cold main is restricted, for example by a stop, check or water meter, an accessory pack which includes an expansion vessel must be fitted. See diagrams 2 and 3 on page 4. A knowledge of the maximum incoming water pressure is an essential requirement prior to installation; where this is not known the local Water Authority should be consulted. Pack U1 Combined pressure reducing and strainer The pressure reducing limits water pressure to 3.5 bar (50 psi). The strainer filters coarse impurities from the water supply. Connection 1 /2" BSP female. Installation Pack U1 must be installed on the cold inlet side of the and before the expansion vessel. Where possible, installation should be on the mains side of the cold water tap draw-off. This will result in balanced water supplies and is particularly important when mixers are to be used. Pack U1 must be used with Pack U5. Pack U5 Expansion vessel and check The expansion vessel when fully charged, will absorb all expanded water produced by the during normal operation. Connection 1 /2" BSP male; precharged 4.1 bar. The check prevents backflow of hot water and eliminates any possibility of crosscontamination between cold and hot water. Connections 15mm compression. Installation Pack U5 must be fitted on the inlet side and in close proximity to the as shown in diagrams 2 and 3 on page 4. Thermostatic blending s allow water to be stored at high temperatures and blended with cold water to a preset outlet temperature. This provides over-temperature protection, and is ideal for the control of Legionellae and the extension of system capacities. Pack U3 TMV2 Connection 15mm compression. Allows water to be safely stored above 60 C. Precisely controls outlet water temperature (range from 35 C to 60 C). Lockable control knob. Fail-safe shutdown. Incorporates check s to prevent cross contamination. Operating pressure from 0.2 bar to 6.0 bar. Pack U7 TMV3 Connection 15mm compression. Fully approved under the TMV3 scheme to the DO8 specification. Allows water to be safely stored above 60 C. Precisely controls outlet water temperature (range from 38 C to 46 C). Unique adjuster key to prevent unauthorised temperature adjustment. Fail-safe shutdown. Incorporates check s to prevent cross contamination. Operating pressure from 0.2 bar to 5.0 bar. Installation diagram and advice Heatrae Sadia offers a dedicated specifier advice line to provide information and advice on specification and installation. This is supported by a fully-trained national sales team, all of whom are qualified to provide further guidance and support locally. Outlet taps Pack U6 Temperature and pressure relief Hot outlet Cold mains feed The temperature and pressure relief is recommended by Heatrae Sadia to give an additional level of safety to. It is pre-set to open at 7 bar (101.5 psi) and 90 C. Pack U6 is the only temperature and pressure relief recommended for use with unvented s. Blended water to outlets Balanced cold water supply Pack U3 or U7 blending Water Connections Inlet and outlet 15mm compression drain 1 /2" BSP female. Installation Pack U6 is connected to the outlet connection on top of the. See diagram 4 on page 4. 5

Full specifications Specification Capacities 10 and 15 litres. Rating kw @ 240V, (2kW @ 230V). Outer casing White plastic top moulding with steel base and centre section, finished in white stove enamel. Thermal insulation CFC/HCFC free (ODP zero) flame-retardant expanded polystyrene. Water container/integral heat unit Replaceable heavy gauge copper inner container, designed for 6 bar working pressure and type tested to 20 bar (290 psi), with embedded rod-type element sheathed in corrosion resistant alloy. Thermostat Rod-type externally adjustable from 10 C to 70 C. Safety features Pressure relief set to open at 6 bar. Resettable over temperature cut-out. Anode Not required. IPX4 rated Approvals Kiwa approved to UK water supply regulations. CE marked. Manufactured in the UK in a BS EN ISO 9001:2000 registered factory. Installation Mechanical Must be mounted in the vertical position with inlet / outlet at the top. Floor or wall-mounted (three screws / keyhole slots). Plumbing 15mm copper tail ends. Minimum water pressure 0.8 bar (12 psi). For pressures above 4.1 bar (60 psi), packs U1 and U5 must be used. NOTE: The pressure relief supplied must always be fitted. See accessory selection guide on page 4. Temperature and pressure relief Optional Pack U6 see accessory selection guide on page 4. Safety discharge The pressure relief (expansion) or temperature & pressure relief (if used) must be plumbed to discharge in a safe visible location. Optional thermostatic blending Accessory Pack U3 and Pack U7 (see page 5) allows water to be stored at high temperature and blended with cold to a preset outlet temperature. Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity of 13 amps. Must conform to current IEE wiring regulations. Guarantee carries a full two year transferable on-site service support guarantee against faulty manufacture or materials provided that: It has been correctly installed as per the instructions contained in the instruction manual and all relevant Codes of Practice and Regulations in force at the time of installation. It has been installed in the UK. It has not been modified in any way, other than by Heatrae Sadia Heating. The damage is not due to scaling or frost. It has only been used for the storage of potable water. It has not been tampered with or been subjected to misuse or neglect. Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product. Evidence of purchase and date of supply must be submitted. The unit is not guaranteed against damage due to frost. The guarantee is transferable. This guarantee does not affect your statutory rights. 6

Dimensions and ordering Dimensions Ordering guide A 190 Fixing centres of wall screws (unit hangs on keyhole slots) E B 171 59 D Model 10 15 Replacement inner container with integral element 15 litre Rating @ 240V (kw) Product code 95:050:148 95:050:149 95:608:916 95:608:917 FRONT SIDE Accessories ordering guide C Model Product code 62.5 50 Accessory pack U1 See page 5 for details 95:970:352 Accessory pack U3 See page 5 for details 95:970:354 Accessory pack U5 See page 5 for details 95:970:356 Accessory pack U6 See page 5 for details 95:970:359 Accessory pack U7 See page 5 for details 95:970:360 TOP Model Capacity Rating @240 A B C D E Weight (litre) (kw) empty full (kg) (kg) 10 10 500 252 267 457 360 6.5 16.5 15 15 656 252 267 613 516 8.4 23.4 7

Contact Specification T: 01603 420220 F: 01603 420229 E: specifier@heatraesadia.com After Sales Service T: 0844 871 1535 F: 0844 871 1528 E: heatraesadiaservice@heateam.co.uk Web www.heatraesadia.com National service network Heatrae Sadia products are inherently reliable and are designed to meet the demanding needs of all users. A nationwide network of experienced engineers is available to provide fast and efficient on-site service support. In addition, spare parts for the complete range of products are readily available through a wide variety of stockists. Brochures for all of our products are available free of charge. Please call our literature hotline on 01603 420127. Domestic Heating and Hot Water Aerheat Amptec Electric Solar Electromax Electromax Solar Megaflo HE Megaflo Solar Megalife HE Showers Commercial Hot Water B3M / C3M Express FBM Handy Handy Dri and Hair Drier Immersion Heaters Multipoint Streamline UTC 99 Drinking Water SuperChill Supreme Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA Heatrae Sadia Heating may introduce modifications to their products from time to time. Consequently, the details given in this brochure are subject to alteration without notice. 95 900 907 Issue 1 Heatrae Sadia Heating. 2009. This product is printed on 50% post consumer recycled paper. That is paper that has been previously used eg. newspapers and magazines. This product is printed using vegetable based inks which are non toxic. Please recycle this product once you have finished with it.