TA-MATIC

Similar documents
TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TRV 300 RADIATOR VALVES

Temperature controller for steam (PN 25) AVT / VGS - external thread

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

JRG Fittings/JRGUMAT JRGUMAT JRGUMAT. Thermoblending valve Compact blending water facility with thermal disinfection

Mounting and Operating Instructions EB 2231 EN

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

ThermoDual Domestic hot water charging system

Shower Thermostatic Mixer Fitting Instructions

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Flush individual room control for floor heating systems

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Thermostatic valves with radiator connection systems

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

THERMOSTATIC MIXING VALVES

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

ROUGH IN VALVES. Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve

TS RD 7761 RD, 7761 RD

Automatic balancing valves ASV-PV (new generation) DN 32-50

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

Thermostatic mixing valves with replaceable cartridge for centralized systems

INSTALLATION INSTRUCTIONS

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Three-way reversing valve

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Components for solar heating systems

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Sema thermostatic bar mixer Installation and operating instructions

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

SECTION SECTION DESIGN REQUIREMENTS

AVTI Multifunctional self - acting controller

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

Dove Eco thermostatic bar mixer shower

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

TYNE. Installation and Operating Instructions. Thermostatic bath shower mixer. Installers please note these instructions are to be left with the user

Varsity Concealed Shower System

Electronic Dual Cylinder Thermostat Installation Instructions

Thermostatic valve bodies

Brazed heat exchanger, XB

The New Caroma TMV20

CROMO manual mixer shower

Installation, Operating and Servicing Instructions

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

INSTALLATION INSTRUCTIONS

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Thermostatic Deck-Mounted Bathtub Mixer Installation Guide

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Brazed heat exchanger XB

User's Instructions. Alpha CB50

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

INSTALLATION FOR THERMOSTATIC VALVES

Pro-Clean Stratified Tank scope of delivery:

Metering systems 0548EN April 2014

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Model: 1100 Float-Controlled Condensate Trap, PN 25

Thames thermostatic bar mixer with diverter Installation and operating instructions

Mimosa dual control mixer shower Installation and operating instructions

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

avant la pose et la mise en service du produit. Thoroughly flush the pipes to remove any impurities

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Inta City Concealed Shower Mixing Valve CT80010CP

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Thermostatic mixing valves with interchangeable cartridges

FERVORE thermostatic mixer shower Installation and operating instructions

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

Planning guide. (2010/09) en

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

Thermostatic Bar Valves

GOLD Plus 30/40/60/80

Universal fuel unit for oil burners

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Protection and Control of Solid Fuel Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Transcription:

TA-MATIC 3400 11-5-15 Thermostatic mixing valve for domestic hot water 2007.06 Technical description Application: Domestic hot water systems Function: The TA-MATIC 3400 is intended mainly as a central mixing unit for domestic hot water systems in apartment buildings, in systems with or without hot water circulation. It works best if the system has a circulation pump. If the system has a circulation pump, the unit can also be used as a central mixer for shower and bath facilities. The TA-MATIC 3400 is available in five sizes, DN 20, 25, 32, 40 and 50. It is supplied with couplings for soldering to copper pipes as standard. Pressure class: PN 10 Temperature: Max. working temperature: 90 C Temperature range: Each size can be supplied with three standard temperature settings: 25 C, 40 C or 55 C.Factory-set standard temperatures can be adjusted within the limits: 20-30 C, 30-45 C, and 45-65 C. Material: Valve body: Gunmetal (SS 5204) Seat: Stainless steel Expansion medium in the thermostat sensing element aregaseous hydrocarbon, wax and pulverized copper. Packaging: The packaging of the TA-MATIC can be used to provide good insulation against heat losses.

TA-MATIC 3400 Incl. couplings For Cu pipe Ø22 and mains connection for Cu pipe Ø12 H1 ***) H2 52 740-220 20 25 20-30 114 47 38 49 1,3 52 740-420 20 40 30-45 114 47 38 49 1,3 52 748-420 20 48 36-53 114 47 38 49 1,3 52 740-520 20 55 45-65 114 47 38 49 1,3 For Cu pipe Ø28 and mains connection for Cu pipe Ø18 L2 L2 52 740-225 25 25 20-30 128 52 43 51 1,7 52 740-425 25 40 30-45 128 52 43 51 1,7 52 748-425 25 48 36-53 128 52 43 51 1,7 52 740-525 25 55 45-65 128 52 43 51 1,7 For Cu pipe Ø35 and mains connection for Cu pipe Ø18 52 740-232 32 25 20-30 148 61 48 75 3,0 52 740-432 32 40 30-45 148 61 48 75 3,0 52 748-432 32 48 36-53 148 61 48 75 3,0 52 740-532 32 55 45-65 148 61 48 75 3,0 For Cu pipe Ø42 and mains connection for Cu pipe Ø18 52 740-240 40 25 20-30 170 68 57 77 3,7 52 740-440 40 40 30-45 170 68 57 77 3,7 52 748-440 40 48 36-53 170 68 57 77 3,7 52 740-540 40 55 45-65 170 68 57 77 3,7 For Cu pipe Ø54 and mains connection for Cu pipe Ø18 52 740-250 50 25 20-30 198 79 67 85 6,0 52 740-450 50 40 30-45 198 79 67 85 6,0 52 748-450 50 48 36-53 198 79 67 85 6,4 52 740-550 50 55 45-65 198 79 67 85 6,0 *) Standard mixing temperature **) Adjustable range ***) Minimum clearance 100 mm Ordering example: To order, specify size (DN 32) and standard temperature (55 C) plus TA No. Example: TA-MATIC 3400-32/55 C, TA No 52 740-532. Data can be obtained from the table above. Gasket kit for TA-MATIC 3400 TA No DN 52 743-320 20 52 743-325 25 52 743-332 32 52 743-340 40 52 743-350 50 The gasket kit consist of 3 gaskets and 1 plastic pipe insert for the main connection.

TA-MATIC 3400 for exchange Excl. couplings For Cu pipe Ø22 and mains connection for Cu pipe Ø12 H1 d1 d2 d1 ***) H2 52 740-221 20 25 20-30 G1 1/4 G1/2 40 60 100 10,5 38 49 0,65 52 740-421 20 40 30-45 G1 1/4 G1/2 40 60 100 10,5 38 49 0,65 52 748-421 20 48 36-53 G1 1/4 G1/2 40 60 100 10,5 38 49 0,65 52 740-521 20 55 45-65 G1 1/4 G1/2 40 60 100 10,5 38 49 0,65 For Cu pipe Ø28 and mains connection for Cu pipe Ø18 d1 L3 L2 L4 52 740-226 25 25 20-30 G1 1/2 G3/4 43 67 110 11 43 51 0,87 52 740-426 25 40 30-45 G1 1/2 G3/4 43 67 110 11 43 51 0,87 52 748-426 25 48 36-53 G1 1/2 G3/4 43 67 110 11 43 51 0,87 52 740-526 25 55 45-65 G1 1/2 G3/4 43 67 110 11 43 51 0,87 For Cu pipe Ø35 and mains connection for Cu pipe Ø18 52 740-233 32 25 20-30 G2 G3/4 52 78 130 11,5 48 75 1,60 52 740-433 32 40 30-45 G2 G3/4 52 78 130 11,5 48 75 1,60 52 748-433 32 48 36-53 G2 G3/4 52 78 130 11,5 48 75 1,60 52 740-533 32 55 45-65 G2 G3/4 52 78 130 11,5 48 75 1,60 For Cu pipe Ø42 and mains connection for Cu pipe Ø18 52 740-241 40 25 20-30 G2 1/4 G3/4 58 92 150 12,5 57 77 2,10 52 740-441 40 40 30-45 G2 1/4 G3/4 58 92 150 12,5 57 77 2,10 52 748-441 40 48 36-53 G2 1/4 G3/4 58 92 150 12,5 57 77 2,10 52 740-541 40 55 45-65 G2 1/4 G3/4 58 92 150 12,5 57 77 2,10 For Cu pipe Ø54 and mains connection for Cu pipe Ø18 52 740-251 50 25 20-30 G2 3/4 G3/4 70 110 180 14,5 67 85 3,37 52 740-451 50 40 30-45 G2 3/4 G3/4 70 110 180 14,5 67 85 3,37 52 748-451 50 48 36-53 G2 3/4 G3/4 70 110 180 14,5 67 85 3,37 52 740-551 50 55 45-65 G2 3/4 G3/4 70 110 180 14,5 67 85 3,37 *) Standard mixing temperature **) Adjustable range ***) Minimum clearance 100 mm Ordering example: To order, specify size (DN 32) and standard temperature (55 C) plus TA No. Example: TA-MATIC 3400-32/55 C, TA No 52 740-533. Data can be obtained from the table above. TA-MATIC 3480 Transistion pieces Complete kit, incl. gaskets. For exchange of 3350 (older blending valve) to TA-MATIC 3400. TA No DN d L2 R Kg d d L2 R d 52 744-020 20 G1 1/4 30,5 40,5 0,49 52 744-025 25 G1 1/2 38 34 0,76 52 744-032 32 G2 39,5 33,5 1,00 52 744-040 40 G2 1/4 44,5 30,5 2* 1,18 52 744-050 50 G2 3/4 44,5 34,5 2* 1,72 *) 2 pieces

General Comfort Desired water temperature just by turning the tap. No other adjustment needed. Safety If the cold water supply fails for any reason, the hot water supply shuts down automatically to a level (drop leakage) where the mixed water will not cause scalding. The TA-MATIC 3400 improves the safety of any hot water installation. Energy saving 1. No water wastage while temperature is adjusted. 2. The normal temperature in the hot water pipes is considerably lower in TA-MATIC systems than in conventional systems. Heat loss decreases substantially. Determination of heat loss To determine heat loss in systems with different sizes, use the table. DN in mm Cu pipes Insulation thickness in mm with heat transfer capacity of: Heat loss in Watts per meter at the following differences between ambient temperature and hot water at: 0,035W/mK 20K 25K 30K 40K 50K 60K 20 20 3,75 4,70 5,64 7,55 9,46 11,37 25 30 3,53 4,42 5,31 7,10 8,89 10,68 32 30 4,04 5,05 6,07 8,20 10,15 12,20 40 40 3,92 4,90 5,58 7,86 9,83 11,81 50 50 3,98 4,97 5,97 7,97 9,97 11,98 The packaging of the TA-MATIC can be used to provide good insulation against heat losses. Sizing In the design diagram for the TA-MATIC 3400, hot water flow is calculated according to BFS 1995:17. For safety, the mixing valve must be installed in accordance with the installation instructions. Valve size Pressure drop Example: The diagram shows choice of valves for a building with 50 apartments. The diagram gives: Water flow: 1.8 l/s Pressure drop TA-MATIC: 55 kpa Choose valve DN 32, Kvs = 8.3 If several alternative valve sizes are obtained, choose the one that results in the highest pressure drop. No of apartments Flow A standard apartment corresponds to a flow of 0,7 l/s.

Capacity diagram Tolerance Tolerance

Function The high thermostat sensitivity and short valve plug stroke ensure a mixing valve that reacts rapidly to incorrect thermostat temperature. The thermostat is fitted at the valve outlet and controls a balanced cylindrical plug, which mixes hot and cold water flow to obtain the desired temperature. If the cold water supply fails, the hot water supply shuts down automatically to a level (drop leakage) where the mixed water will not cause scalding. High water temperature plus hard water (dh >20) can impair the function of the valve. Fig. 1 Thermostat A is located in mixing chamber B. It is sensitive to all changes to the selected water temperature, and plug C acts immediately through the setting spindle D, which controls the hot and cold water supply. Allen key 5 mm (DN 20-25) Allen key 8 mm (DN 32-50) Temperature setting Hot water mains Hot water Mixed water Cold water

Function The TA-MATIC 3400 mixing valve has a thermostat set to one of the three standard temperature ranges. The factory-set standard temperature is indicated on the temperature plate (Fig. 2). Different temperature settings are limited to the specified range and can be changed as follows: Insert Allen key E in the centre of the temperature plate F (Fig. 1). NOTE! The temperature plate must not be removed. Turning the screw clockwise increases the water temperature and turning it anticlockwise reduces it. The volumetric flow must be in accordance with the diagram. The hot water temperature must be at least 5 C above the thermostat setting. Factory-set standard temperature Temperature range One full turn of the Allen key changes the temperature C C DN 20-25 (3/4-1 ) DN 32-50 (1 1/4-2 ) 25 20-30 40 30-45 approx. 6K approx. 6K 55 45-65 Fig. 2 Example of the temperature plate. Standard temperature Temperature range

Function Example of control of hot water from boiler. System with constant circulation losses. No hot water tap upstream of the TA-MATIC Tapping points Heat lock Valve stem Circulation pump To achieve a heat lock, the TA-MATIC must be installed at less than half the height of the boiler. *) Alternatively, install two STAD, two TRIM or two STK. TA-MATIC 3400 as safety mixer in district heating systems Install the TA-MATIC upstream of the valve stem to avoid circulating water being drawn back through the preheater and being warmed before reaching the cold-water port of the TA-MATIC. A mains outlet should be provided downstream of the check valve to the TA-MATIC cold water inlet. The temperature setting of TA-MATIC should be higher than the setting of the primary controller. Primary controller Tapping points Circulation pump Heat lock Valve stem Tour & Andersson retains the right to make changes to its products and specifications without prior notice.