Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Similar documents
Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

SEALED THERMAL STORE

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Heat Interface Units for decentralised water heating in district heating systems

Installation and Servicing Instructions. Alpha FlowSmart

Installation, Operating and Maintenance Guide

Dual Control Concealed & Exposed Thermostatic Shower Valve

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

Pump assembly Instruction manual

Plus Bath Shower Mixing Valve CP and PL30020CP

Inta City Concealed Shower Mixing Valve CT80010CP

Friwa Compact. Operating instructions EN

HKF 8180 Operating instructions

Puro Mini Dual Control Shower Mixer PU90010CP

Thermostatic Concealed Shower Valve

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

C90 Instruction Manual

Inta City Shower Mixing Valve CT20010CP

Telo Shower Mixing Valve TL10016CP

CENTRA-COIL QUALITY HOT WATER SERVICE

Kiko Bath Shower Mixing Valve KK90015CP

Enzo Concealed Shower Mixing Valve

SANTA CRUZ. Santa Cruz ShowerSpa Model #1033 Owner's Manual

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

OUTLET HOT INLET COLD INLET INSTALLATION

ADVANCE ECB ELECTRIC COMBINATION BOILER

Pear Kitchen Sink Tap

Deluge Shower Mixing Valve 10045CP

CROMO manual mixer shower

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Thermostatic bar mixer valve with adjustable head Installation guide

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Beeline Monobloc Kitchen Mixer Tap

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Target Monobloc Kitchen Mixer Chrome

Oahu Showerspa Model #1035 Owner's Manual

Installation Instructions

ELECTRIC BOILERS FOR CENTRAL HEATING

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Traditional Rigid Riser With Eight Inch Rose

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

Installation & Technical Guide. Domestic & Commercial.

Manual. Above-counter dispenser for hot drinks OTHG /12

Installation Instructions

Installation and operating instructions. DK energy storage and DK energy buffer

Mio Concealed Shower Mixing Valve MI40010CP

Instructions for installation and use Akva Lux II VX substations 1. Contents

Deluge Concealed Shower Mixing Valve DL40010CP

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Manual and Thermostatic Power Shower Units

Installation Instructions. Starck

Powerflow Unvented water heater

Performance on demand

TECHNICAL PROPERTIES OF THE APPLIANCE

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

INSTALLATION ADJUSTMENT SERVICE

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Mikrofill Ethos Condensing combination boiler

HW 22 District heating substation for indirect heating and domestic hot water systems

Waimea ShowerSpa MODEL #1034

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Intatherm Safe Touch Basin Tap IT1008CP

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Thermostatic mixing valves with replaceable cartridge for centralized systems

SCHWAN INSTALLATION GUIDE

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Akva Vita Instantaneous water heater

Thermostatic Bar Valves

HX-30/40 and HX-30/40 S Glass and Dishwashers

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Artisan Thermostatic Bath Filler

Installation Instructions. Hansgrohe S 15721XXX

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

INSTANTANEOUS ELECTRIC SHOWER

Glass and Dishwashers AMX / AUX Series

Installation Instructions for. DairyFount Series Fountains

Glass and Dishwashers AMX / AUX Series

Kiko Concealed Shower Mixing Valve KK80010CP

Alpha FlowSmart 25 and 50

Cinnamon Kitchen Sink Tap

Thermostatic mixing valves with interchangeable cartridges

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

Transcription:

DE LUXE Substation

Introduction The HERZ DE LUXE Substation is a firmly mounted unit for providing hot water. In contrast to a hot water boiler which heats and then stores the water before it is being used, the substation starts working only when hot water is needed. The HERZ DE LUXE Substation ensures constant temperature and flow of hot water no matter how much or how often water is drawn from a tap. 1. Function In the stand-by mode the heating water flows from the primary circuit (district heating main) via a bypass which is kept at operating temperature with a return temperature limiter. Thus heating water from the primary circuit is always and immediately available at the heat exchanger. If hot water is drawn from a tap by a domestic user connected to the system, the control valve of the cold and heating water is opened by the difference in pressure. Thus cold water flows through the heat exchanger, is heated up and promptly available as hot water at the domestic hot water tap. The temperature of the domestic hot water is controlled by a thermostat. Using an immersion sensor, this thermostat controls the temperature of the hot water that exits the heat exchanger, which in turn regulates the pressure and temperature controller. As a safety measure (in accordance with EN 1111), a thermostatic mixing valve is fitted for the domestic hot water system so as to prevent scalding at the tap. Due to this safety fitting the hot water can be below the desired temperature if only a little quantity of water is used or the tap is turned on briefly. A strainer with a fine-mesh screen of 0.75 mm is fitted to catch impurities. 1.1 Operating data For providing hot water With fitted flow rate limiter: 14 l/min Inlet pressure: 3.5 bar Incoming water temperature in C 60 75 60 75 Amount of water drawn in l/min. approx. 13 approx. 13 approx. 13 approx. 13 Temperature of cold water in C 10 10 10 10 Pressure drop in kpa 20 20 25 25 Flow rate in l/h approx. 600 approx. 600 approx. 600 approx. 600 Temperature after heat exchanger in C Heating capacity of the heat exchanger in kw 45.4 57.5 46.6 57.1 32.0 42.3 33.0 42.0 Weight of the HERZ DE LUXE Substation with mounting plate: Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg Weight of the HERZ DE LUXE Substation without mounting plate: Empty unit Cover Water Total weight 12 kg 8 kg 10 kg 30 kg 2

2. Hot water demand Hot water consumption depends on the number of household occupants, the sanitary conditions of the flat or house and the consumer s individual habits. Here are some guidelines to calculate hot water demand: Hot water demand in litres Required water storage volume in litres at 37 C at 55 C at 80 C at 60 C Bath 150-180 55-66 78-94 Shower 30-50 11-18 16-26 Washing hands 3-6 1-2 1.6-3.1 Washing hair 6-18 3-6.6 4.2-9.4 Bidet 12-15 4.4-5.5 6.3-7.8 Washing dishes for 2 people per day 16 10 14 for 3 people per day 20 12.5 18 for 4 people per day 24 15.2 21.5 Cleaning the house per bucket of water 10 6.3 9 3. Saving energy So as to optimise energy saving with your HERZ Substation, you should consider the following: 1. Washers of all taps and fittings should be checked at regular intervals and, if necessary, changed, as, for example, a dripping tap can waste up to 4,000 litres of water a year. 2. When using a single-lever mixer tap for drawing cold water, position the lever as far right as possible, to the cold setting. Otherwise you will be wasting hot water, as most mixer taps begin blending hot with cold water as soon as they are moved from the hard right position. 3. In addition to the suggestions above, we recommend using our HERZ PRESTIGE range of taps and fittings, as these have a water saving setting for short tap use (such as washing hands). 4. Do not use running water for short activities like washing hands or face, brushing teeth, and so on. 5. You should shower rather than have a bath, as a bath uses three to four times more water than a shower. 4. Temperature setting The HERZ Substation is set to a default temperature of max. 55 C. The settings of the thermostat cannot be changed to ensure the optimal tap water temperature at all times. 3

5. Installation HERZ DELUXE Substation with mounting plate 1. Remove the HERZ Substation from the packaging. The packaging carton is used as a template for drilling holes. 2. Cut out template from the packaging carton. 3. Place template horizontally onto the wall with the help of a spirit level and mark the required bore holes. Mounting the mounting plate and connecting pipes 4. Drill holes for the mounting plate with a suitable drill. 5. Insert wall anchors. Use suitable anchors for the type of wall. 6. Fix the mounting plate onto the wall with two screws and tighten them slightly. 7. Connect the ball valves to the respective pipes. Mounting the main unit Thanks to the plug-in system, the main unit can easily be installed at a later point in time when handing over the flat or house. However, we recommend drilling all necessary holes before that. 8. Drill holes for mounting the main unit. 9. Insert wall anchors. Use suitable anchors for your type of wall. 10. Screw in two of the screws halfway. 11. Hang main unit on the hexagonal head screws and connect it to the mounting plate. 12. Do not fully tighten the screws at this point. 13. Screw two screws into the oblong holes. 14. Tighten all screws firmly. 15. Double check the stability of the HERZ Substation and ensure that it is firmly in place. 16. Attach cover. Mounting hole Main unit Oblong holes Holes for mounting plate Mounting plate 4

6.1. General notes on installation 1. For installation please refer to the drawings and manual included in the packaging. 2. When choosing where to mount the HERZ Substation, the weight of the substation itself as well as the weight of the water must be taken into account (see also chapter 1.1 Operating data). 3. If the HERZ Substation is built in or installed in confined spaces, intermediate ceilings, etc., the front of the unit must be freely accessible for repair and maintenance purposes. 4. Before mounting the HERZ Substation, check that the wall is vertical. 5. Depending on the type of wall where the unit is mounted, the appropriate wall anchors and screws must be used. 6.2. Safety notes 1. The substation must be installed and connected by professional plumbing and heating engineers only. 2. Only use original HERZ spare parts to replace faulty parts or heating components. 3. Check all connections for leakages prior to starting up the heating system. 4. All screws must be checked and tightened after the substation has been installed. 5. The user must not make any technical changes to the heating system. Otherwise HERZ will not assume liability for any resulting damage. 6. The HERZ Substation must only be installed in rooms and locations that meet the legal requirements. 7. Starting-up The HERZ Substation is easy to operate and user-friendly. All you have to do is open up the ball valves in the following order so as to avoid water hammers: 1. Open heating water inlet slowly (red ball valve). 2. Open cold water inlet slowly (green ball valve). 3. Open heating water return slowly (red ball valve). 4. Open hot and cold water outlet slowly (green ball valve). 8. Operating conditions Besides the national rules and regulations, the industrial standards as well as the connection conditions of the local water supplier need to be met and, furthermore, installation and operating instructions need to be followed. The room where the substation will be installed should be frost-free and the place of installation has to be chosen in such a way that the substation is easily accessible for maintenance and repair work. The incoming water temperature should range between a minimum of 60 C and a maximum of 80 C. A primary static pressure of 10 bar and a primary differential pressure of 0.5 bar are fine. Furthermore, in case of system failure, all connecting pipes must be able to withstand a maximum temperature of 95 C. 5

9. Function schematic of the HERZ DE LUXE Substation System description: The control system consists of a heat exchanger (9) with a HERZ differential pressure controller (1) which, as the central unit in the HERZ Substation, ensures the provision of hot water and constant temperatures. Through the difference in pressure the valve opens or shuts the heating water and the cold water inlet to the exchanger, and simultaneously the temperature of the hot water is controlled by a thermostat. The mixing valve for the domestic hot water system (6) is another essential component of the HERZ Substation. It is fitted with a thermostat and mixes cold and hot water to the desired temperature in order to avoid scalding at the tap. Hot water is drawn via the HERZ ball valves (8). 1 1 4008 01 HERZ differential pressure controller 2 1 7758 91 HERZ thermostatic valve with bypass 3 1 9201 00 HERZ return temperature limiter 4 1 4111 51 HERZ strainer 5 1 9421 26 HERZ thermostat 6 2 7766 52 HERZ mixing valve for the domestic hot water system 7 1 2100 12 HERZ ball valve 8 2 2100 02 HERZ ball valve for the drinking water system 9 - heat exchanger 10 - Water meter 11 - Heat meter 12 1 4002 81 HERZ differential pressure controller, Fix-TS 13 1 7709 01 HERZ actuating drive 14 1 7791 23 HERZ room temperature controller 6

9. Connecting to the district heating main The HERZ Substation is connected parallel to the district heating main. If possible, the substation should be installed before the first end user. 7

10. Initial start-up In accordance with the Austrian ÖNORM H5195-1 standard, before initially starting up the HERZ Substation, make sure to use only clean pipe materials that comply with standards (i.e., all pipe work must be free from forging scale, rust, burrs and impurities). The same holds true for fittings and units (boilers, radiators, convectors, expansion vessels, etc.). The Austrian ÖNORM H5195 standard further provides for clean and professional workmanship (without welding beads, sealing or solder residues, burrs, bore chips and others) and cleaning of all components prior to their installation. Strainers should be fitted because deposits in the pipes can damage the controller and impurities can enter the drinking water system. To prevent corrosion in the heating system, the Austrian ÖNORM H5195-1 standard requires the following measures: When installing and operating the heating system, make sure that as little air as possible enters the closed heating circuit. Before initially starting up the heating plant, flush it through twice (so that the entire water contained in the system is replaced twice). Then fill with clear, filtered water (filtered with a 25 µm pore size filter) of the required quality standard. When first starting up the heating system, it must be kept running at normal operating conditions for 24 hours so that the heating water is evenly mixed with the inhibitor. Old heating systems must be treated with a chemical cleanser and then flushed with water before refilling them. Do not partially or entirely drain the heating system, leaving it without anti-corrosion treatment for a prolonged period of time; otherwise the system will be more susceptible to corrosion. To avoid damage by frost at low temperatures, the heating system must be protected in compliance with the Austrian ÖNORM H5195-2 standard as follows: In general, anti-freeze and water can be mixed to any percentage. However, heating systems with circulation pumps should be filled two thirds with water, then the anti-freeze added and only then should the system be topped up with water. The anti-freeze will be thoroughly mixed with the water once the system is put into operation and the fluids start circulating. Gravity-fed heating systems, however, must be filled with a combined anti-freeze and thermal fluid. If anti-freeze needs to be put into a heating system that has so far been unprotected, the following must be observed: 1. Ensure that the anti-freeze is suitable for the sealing materials. 2. The system should be power flushed. 3. After having added the anti-freeze, the system must be double checked for leaks. In order to be able to do this, HERZ recommends using the HERZ multifunction ball valves on the inlet and return pipes (order no.: 1 2414 xx and order no.: 1 2415 xx, respectively). 11. Shutting down, emptying Shutting down the HERZ Substation for a prolonged period of time or dismantling it for whatever reason is done by shutting all ball valves. In rooms exposed to temperatures below freezing the HERZ Substation must be drained down prior to the start of the cold season if the substation is to be shut down for several days. To drain the substation, place a vessel with a capacity of 4 to 8 litres underneath the substation and drain the hot water from the ball valves till the HERZ Substation is completely empty. If temperatures are liable to drop below freezing point, be aware that not only the water in the HERZ Substation and the hot water pipes may freeze but also the water in the cold water inlet pipes leading to the fittings and to the unit itself. Therefore it is best to drain all water pipes and pipe fittings up to the frost-proof part of the domestic heating system. 8

12. Servicing and maintenance Owing to its outstanding design, the HERZ Substation requires comparably little maintenance work. However, in hard water areas lime-scale can build up in the system. Depending on the hardness of the water, your system should be de-scaled by a professional every one to two years. In case scale in the system has damaged the valves, these should be replaced immediately to ensure smooth operation of your heating system. If the strainers provided have been fitted into the mixing valves, they have to be inspected by a plumber at regular intervals in order to prevent the hot water temperature from rising. Do not clean the unit with scouring or harsh cleaning products. Wipe it down with a damp cloth which has been rinsed in water with a few drops of mild detergent. 13. Troubleshooting, malfunctioning Problem: The hot water temperature is too high. Solution: The HERZ mixing valve must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. The HERZ controller must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. Problem: The hot water temperature is too low. Solution: The heat exchanger must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. Check with your district heating provider whether there is a failure in their system. Check that the red ball valves are turned on. The thermostat controller must be checked and, if necessary, replaced by a qualified and approved plumbing and heating engineer. The whole system must be checked by a qualified and approved plumbing and heating engineer for scale buildup. 14. Accessories and spare parts Article Order no. HERZ mixing valve for the domestic hot water system 2 7766 40 HERZ controller 1 4008 02 HERZ thermostat 1 9421 25 HERZ return temperature limiter 1 9201 02 HERZ thermostatic valve with bypass 1 7746 91 HERZ ball valve for the district heating main 1 2420 02 HERZ ball valve for the drinking water system 2 2420 02 Heat exchanger CB 20/40 9