PRODUCT CONFORMITY CERTIFICATE

Similar documents
PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Certificate: _01 / 20 August 2013

PRODUCT CONFORMITY CERTIFICATE

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 2 February 2015

Certificate: _02 / 9 September 2014

Certificate: _01 / 29 April 2014

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _02 / 22 March 2013

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

Certificate: / 9 February 2011

CERTIFICATE of Product Conformity (QAL1 )

PRODUCT CONFORMITY CERTIFICATE

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

Certificate: / 9 September 2014

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1)

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Automatic Isokinetic Sampler ST5

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

Glenside Environmental Services Ltd

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

MANUFACTURER OF POLLUTION CONTROL SYSTEMS

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

continuous emissions monitoring Combustion & Environmental Monitoring

CERTIFICATE of Product Conformity (QAL1 )

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 19 August 2011

CONFIRMATION of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

portable gas analyser

portable gas analyser

_03 / 28 July 2015

Certificate: / 29 April 2014

DESCRIPTION AND SPECIFICATION

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE of Product Conformity (QAL1 )

gas monitoring system

CERTIFICATE of Product Conformity (QAL1)

NO NO 2 NO x SO 2 CO CO 2 O 2

CERTIFICATE of Product Conformity (QAL1)

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

The Emergence of Triboelectric Technology

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

INTERNATIONAL STANDARD

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

ACTIVITIES OF THE MEASURING GROUP

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Users Manual. Air Velocity Meter

Complete Gas Analysis

This document is a preview generated by EVS

SOUND RECEPTION SYSTEM

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

PREDICTING GASEOUS AIR CLEANER PERFORMANCE IN THE FIELD

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

MONITORING & CONTROL. the expert approach. Dust Sensors.

The New DUSTTRAK II and DRX Aerosol Monitors

Operating instructions for moisture analyzers - UX 3001 (UX 3011, UX 3031, UX 3081) series

SystemsQT for Waters Alliance HPLC Systems (Revision G)

The New DUSTTRAK II and DRX Aerosol Monitors

New European Cable Testing and Classification

CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP AND UHV600-15HP-20850

Transcription:

PRODUCT CONFORMITY CERTIFICATE This is to certify that the AMESA D Isokinetic Dioxin Sampling System Manufactured by: Environnement S.A. Deutschland Benzstraße 11 61352 Bad Homburg Germany has been assessed by Sira Certification Service And for the conditions stated on this certificate complies with: MCERTS Performance Standards and Test Procedures for Automatic Isokinetic Samplers, Version 3 dated September 2016 Certification Ranges : Velocity 1.1 m/s to 30 m/s Project No.: 70117064 Certificate No: Initial Certification: 15 March 2012 This Certificate issued: 15 March 2017 Joe Prince MSc, MInst MC Renewal Date: 14 March 2022 Deputy Certification Manager MCERTS is operated on behalf of the Environment Agency by Sira Certification Service Unit 6, Hawarden Industrial Park Hawarden, Deeside, CH5 3US Tel: +44 (0)1244 670 900 The MCERTS certificate consists of this document in its entirety. For conditions of use, please consider all the information within. Page 1 of 6

Certificate Contents Approved Site Application... 2 Basis of Certification... 2 Product Certified... 3 Certified Performance... 4 Description... 5 General Notes... 6 Approved Site Application Any potential user should ensure, in consultation with the manufacturer, that the monitoring system is suitable for the intended application. For general guidance on monitoring techniques refer to the Environment Agency Monitoring Technical Guidance Notes available at www.mcerts.net On the basis of this evaluation the isokinetic sampling system is considered suitable for continuous sampling of dioxins, furans and other persistent organic pollutants (POPs) on any process where the stack conditions are within the performance of the certification range of this instrument. The AMESA D sampling system was assessed on the basis of a five-month field trial, mounted on a municipal waste incinerator under the following conditions: Velocity range 1.1 to 30 m/s Stack temperature range 140 to 150 C Dust concentration < 2 mg/m 3 Humidity 12 17 Vol.-% f f Basis of Certification This certification is based on the following Test Report(s) and on Sira s assessment and ongoing surveillance of the product and the manufacturing process: TÜV Rheinland Report No. 936/21212537/A Cologne 10th October 2011 TÜV Rheinland Report No. 936/21221445/A Cologne 9th October 2013 Page 2 of 6

Product Certified The AMESA D sampling system is a fully automatically controlled sampling system which consists of the following parts: Cooled Sampling Probe with integrated Pitot- or Prandtl-tube. Cartridge box with adsorber cartridge and cartridge box Control cabinet with process control computer The unit can also be fitted with the following options: Heater control cabinet and cartridge box (integral heater) and line between sampling probe and cartridge box (self-regulating heating cable) Air conditioner control cabinet (sidewall air conditioner) cartridge box (air conditioner or Vortex cooler) Additional dust filter implemented in the adsorber cartridge or mounted after the adsorber cartridge. This certificate applies to all instruments fitted with software version P86.013.0 (Serial number 209 onwards). Page 3 of 6

Certified Performance The instrument was evaluated for use under the following conditions: Test Accuracy of Isokinetic sampling rate response to changes in flue gas velocity Accuracy of determination of volume of gas sampled Results expressed as % of the certification range <0.5 <1 <2 <5 Other results MCERTS specification 3.8 ±5% -0.8 ±2% Linearity of Isokinetic sampling rate -2.0 ±5% Response time T90 (seconds) 25 s <100 s Flow repeatability under laboratory conditions 0.49 ±5% Minimum operational velocity 1.1 m/s 2 m/s Short term drift 0.7 ±2% Accuracy of the determination of volume gas sampled calculated as an average of ten runs performed during the first and last month test Flow reproducibility under field conditions calculated from ten independent measurement results at one fixed location within the duct Availability over three months continuous use 1.6 ±5% 3.6 ±5% >99 % >95% Page 4 of 6

Description The AMESA D dioxin/furan monitoring system is designed to monitor dioxin (PCCD)/ furan (PCDF) and other POPs emissions in the flue gasses of incinerators. One of the features of this unit is fully automated sampling over a period of up to 6 weeks. Precipitation of all the substances to be analysed takes place in a single adsorber cartridge. The AMESA D system consists of a control cabinet and a cooled sampling probe as described in the cooled probe method of CEN/TS 1948-5 which is connected to the cartridge box. The cooled probe extracts a sample from the flue gas stream under isokinetic conditions. Dioxins and furans are collected by the integrated dust filter (quartz wool followed by fine dust filter) and adsorber resin in the cartridge. The AMESA D system was validated for - a maximum sampling period of 6 weeks - a dioxin concentration of 0.5 ng/m 3 TEQ (by a sample volume of 260 m 3 and 70 gr XAD-2) and - a maximum adsorber cartridge temperature of + 50 C. In the control cabinet there is a process control computer with which the system is controlled and operated. The menu-assisted software enables the system to be operated and monitored with a minimum of staff time. The data necessary for analysis is recorded automatically during the up to 6 weeks long period of measurement. The probe gas flow volume is determined by means of a calibrated mass flow meter which is monitored by an additional built-in gas meter. In the cartridge box there is the adsorber cartridge and a second process control computer which handles all measurement and control applications on the stack. The controller of the cartridge box and the control cabinet communicate by TCP/IP protocol. It is possible to connect up to 4 cartridge boxes on 1 control cabinet. This allows the control of a sequential sampling on up to 4 different stacks. The cartridge and the USB-flash disk must be evaluated in a laboratory that is familiar with the analysis of PCDD/PCDF adsorber cartridges. The manufacturer states that the temperature range for the equipment is as follows: Cartridge box: 0 to +45 C (-20 to +55 C with heater and/or air conditioner) Flue gas temperature: up to 400 C Control unit: 5 to +40 C (-20 to +50 C with heater and/or air conditioner) The complete system can be also remote controlled by an internet access. The manufacturer states also that the system can handle higher dust loads until 150 mg/m 3 and flue-gas velocities of more than 40 m/s. Page 5 of 6

General Notes 1. This certificate is based upon the equipment tested. The Manufacturer is responsible for ensuring that on-going production complies with the standard(s) and performance criteria defined in this Certificate. The Manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management system shall be subject to regular surveillance according to Regulations Applicable to the Holders of Sira Certificates. The design of the product certified is defined in the Sira Design Schedule for certificate No. 2. If certified product is found not to comply, Sira Certification Service should be notified immediately at the address shown on this certificate. 3. The Certification Marks that can be applied to the product or used in publicity material are defined in Regulations Applicable to the Holders of Sira Certificates. 4. This document remains the property of Sira and shall be returned when requested by the company. Page 6 of 6