ULTRAVIOLET WATER TREATMENT

Similar documents
Optional / Ergonomic Accessories for Clean-Air & Containment Cabinets

Ultraviolet PCR Cabinets and Workstations

Customized Drinking Water

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Ultraviolet Sterilizers

HEPA/UV3 Sterilizing PCR Workstation and Cabinet

Ultraviolet Disinfection Systems

Ultraviolet Disinfection Systems

Section 3: Ultraviolet - UV

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

MODEL NO. UNIT PRICE FOB SIZE UV A 1/2GPM (6 WATT)

254 Nanometer Germicidal UV Disinfection Systems

ULTRAVIOLET PORTABLE AREA SANITIZER

HF Series R_RevB

uv and ozone for commercial pools

Professional Amalgam Non-regulated

Owner s Manual. Installation, Operation and Maintenance. SPV-200, SPV-410, spv-600, spv-740, spv-950

PRO Series PRO10 PRO20 PRO30

ADVANCE Ultraviolet (UV) Water Treatment System

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

GERMICIDAL ULTRAVIOLET FIXTURES

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

ULTRA-VIOLET STERILIZATION

1020 Industrial Drive, Orlinda, TN fax

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

ULTRAVIOLET INDIRECT AIR DISINFECTION

A Comparative Analysis of Ultraviolet Light Decontamination vs. High Heat Sterilization in the Cell Culture CO 2

PRINCIPLE MAIN APPLICATION

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

Owner s Manual. Installation, Operation and Maintenance. SC200-DWS11, SCm200-DWS11. Manufactured in Canada by:

GERMICIDAL ULTRAVIOLET IRRADIATORS

Model D24-1S. Model D24-2S

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

Ultraviolet (UV) Water Treatment System

TROJANUVSWIFT SC. Drinking Water Treatment

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

ULTRAVIOLET SANITARY CONDIT IONERS

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

Patient Compartment Light

Ultraviolet Water Sterilizer Installation and Maintenance Manual

A STATE OF THE ART INTEGRATED CHEMICAL BIOLOGICAL & RADIATION WATER MONITORING SYSTEM

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

Ultraviolet Air Disinfection Equipment

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at Powered by

Model RS72. Model RSCS280A. Model RSM2680

WEDECO Quadron UV System

AMERICAN AIR & WATER, INC.

Owner s Manual. Models: PUV -7 PUV -14

Owner s Manual. Powered by. Models: NSF Standard 55 Class B Validated Models: S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, S5Q-P/12VDC

Operation & Installation Instructions

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

GRU-V Air Purifier. Product Manual

Cleaning & Sanitising Food processing industry. Replacing synthetic cleaners & sanitisers by natural alternatives

UV Light Fights Germs and Promotes Safer and Healthier Indoor Environment

ULTRA-VIOLET STERILIZATION

OWNERS MANUAL. Operation & Installation Instructions

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

Customer Manual. MADE IN USA Effective

'W' HATENBOERWATER Fresh In water since l906.

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

OWNERS MANUAL. Operation & Installation Instructions.

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

DRINKING WATER PRODUC TS

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

SLT-Series Installation and maintenance instructions

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

PureLine D. Technical Specification

Operation & Installation Instructions

THE THREATS YOU CAN T SEE. THE DIFFERENCE YOU CAN.

Operation & Installation Instructions

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

ONE-STEP DETERGENT DISINFECTANT

Pro-MAX Ultraviolet Sterilizer

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

Installation, Operation and Maintenance Manual

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

ULTRAVIOLET (UV) DISINFECTION EQUIPMENT: MAJOR APPLICATIONS AND GLOBAL MARKETS. IAS037C January Shalini Ramamurthy Project Analyst

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

UV I UNIT030W / UV I UNIT055W

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Water Filter. cover. start button. reminder of cartridge replacement. remainder of life of a cartridge it is time to replace a cartridge

PRECAST CONCRETE. Never Looked So Good!

AEM EASY DRUM M A N U A L

Labgard Reverse Horizontal Flow Safety Cabinet. Models NU /630. Operation and Maintenance Manual

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Intense, cold and dry Efficient disinfection of packaging materials Premium UV solutions from Heraeus Noblelight

Intensive UV light means not a chance for germs!

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

SUMMARY OF ANTIMICROBIAL ACTIVITY

Owner s Manual. Models: Plus Models: PRO Models: Powered by H, K H+, K+ PRO10, PRO20, PRO30, PRO _RevAB

Installation, Operation and Maintenance Manual

for Drinking Water Systems

AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

A measured step forward

Owner s Manual. Models: Powered by S2Q-OZ, S2Q-OZ/2, S8Q-OZ, S8Q- OZ/ _RevJ

Aquapurification.com. Ozone. Ozonation Process: SGA Series: Ozone/Oxygen Systems:

Transcription:

VIQUA Sterilight TAP Series Point of Use UV Systems VIQUA TAP Series Ultraviolet Disinfection Systems are specifically designed for pointof-use applications where microbiological control is required. Ultraviolet water treatment controls bacteria, virus and protozoan cyst (specifically giardia lamblia and cryptosporidium). VIQUA TAP series are installed at a single tap (or faucet) within a home, cottage or business. TAP systems are also suitable for fountains or low-flow applications (1-4 gpm). FEATURES & SPECIFICATIONS 99.99% destruction of bacteria, virus and protozoan cysts (Giardia Lamblia and Cryptosporidium) at rated flow. TAP Systems feature an on indicator light. TAP Plus System features visual lamp change count down timer display and audible lamp failure and lamp replacement reminder alarms. 304 Stainless Steel Reactor Chamber Sterilume-EX hard glass, coated lamps with 9000 hour lamp life 214 fused quartz sleeves with fire polished end 5 lamp cord Ambient Temperature: 36-104 F (2-40 C) TAP SERIES UV SYSTEMS Model No.* Flow Rate** Connection Power @ 16 mj/cm² @ 40 mj/cm² Consumption, Inches Length Cell Dia. Lbs. VT1 2.0 8 0.7 3 ½ MNPT/ ⅜ FNPT 13W 12.5 2.5 4.0 VT4 6.5 24 2.5 9 ½ MNPT 20W 17.0 2.5 6.5 TAP Plus System with count down timer display and audible lamp failure & replacement alarms. S2Q-PA 5.0 11 2 8 ½ MNPT 22W 17.0 2.5 7.0 *Models listed above are North America (NEMA P-15) Voltage. Alternative voltages can be ordered by adding the voltage code to the end of the part number. /2 = EU CEE (CEE 7/7) /2A = AUS/NZ (AS 3112) /2B = UK (BS 1363). Example: VT1/2 For System UV Lamp Quartz Sleeve Controller Kit VT1 S212RL QS-212 BA-VT * VT4 S330RL QS-330 BA-VT* S2Q-PA S330RL QS-330 BA-ICE-S* *North America voltage. Use Voltage Codes above for alternative voltages. Part # For System Description OR-212 All Lamp O-Ring (410867) RN-001 All Retaining Nut 4109958-R All 2.5 Mounting Brackets 270276-R All Lamp Connector Base SP008 All Lamp Connector Spring Typical TAP System Installation

VIQUA Sterilight Home Series Point of Entry UV VIQUA HOME Series Ultraviolet Disinfection Systems are specifically designed for point-of-entry water treatment in homes or light commercial applications where microbiological control is required. FEATURES & SPECIFICATIONS 304 stainless steel reactor chamber Visual lamp change count down timer with audible lamp replacement reminder Home PLUS System also features UV Sensor to monitor the UV intensity in the system Ambient temperature: 36-104 F (2-40 C) Model No.* Flow Rate** @ 16 mj/cm² @ 40 mj/cm² Power Consumption Inlet/Outlet Connection (Inches) Chamber S5Q-PA 11.0 42 4.5 17 30W ¾ MNPT 22 x 2 ½ 8 lbs S8Q-PA 19.0 72 8.0 29 46W ¾ MNPT 35 ½ x 2 ½ 10 lbs VH200 16.0 60 7.0 26 35W ¾ -1 Combo NPT 17 ¾ x 3 ½ 12 lbs VH410 34.0 130 14.0 54 60W ¾ -1 Combo NPT 23 ½ x 3 ½ 17 lbs Home Plus System with UV intensity monitor with continuous feedback of UV disinfection performance. VH410M 34.0 130 14.0 54 60W ¾ -1 Combo NPT 23 ½ x 3 ½ 17 lbs *Models listed above are North America (NEMA P-15) Voltage. Alternative voltages can be ordered by adding the voltage code to the end of the part number. /2 = EU CEE (CEE 7/7) /2A = AUS/NZ (AS 3112) /2B = UK (BS 1363). Example: S5Q-PA/2 Optional: VH200, VH410(M) are available with temperature management: Order valve part # 440179 (sold separately.) For System UV Lamp Quartz Sleeve Controller* S5Q-PA S463RL QS-463 BA-ICE-S S8Q-PA S810RL QS-810 BA-ICE-S VH200 S200RL-HO QS-001 BA-ICE-CL VH410 S410RL-HO QSO-410 BA-ICE-CL VH410M S410RL-HO QSO-410 BA-ICE-CM *North America voltage. Use Voltage Codes above for alternative voltages. Part # For System Description OR-212 All Lamp O-Ring (410867) RN-001 All Retaining Nut 4109958-R SQ 2.5 Mounting Bracket 410076 VH 3.5 Mounting Bracket 270276-R SQ Lamp Connector Base SP008 SQ Lamp Connector Spring 254NM-C1 VH410M UV Sensor for Monitored

VIQUA Professional & Professional Plus UV Systems AMI offers VIQUA Professional Series light commercial product line in flow rates ranging from 10 to 340 GPM for use in a wide range of applications. VIQUA Professional Plus series include a UV sensor to monitor the UV intensity, for increased assurance of water sterilization at all times, and NSF 55 rating on select models. APPLICATIONS FOR VIQUA PROFESSIONAL SERIES UV INCLUDE: Schools/Daycares Elder Care Facilities Healthcare Facilities Cottages Camps Offices Public Buildings Restaurants Hotels & Resorts Dairy Livestock PROFESSIONASL SERIES VIQUA STERILIGHT ULTRAVIOLET SYSTEMS FEATURES & SPECIFICATIONS: Visual lamp change count down timer & audible replacement reminder Ambient temperature: 36-104 F (2-40 C) Model No.* Flow Rate* Power Inlet/Outlet Reactor @ 16 mj/cm² @ 40 mj/cm² Consumption Connection Chamber Chamber Controller Material (L H D) VP600 40 150 22 83 70W 1 MNPT 304SS 302/ 3 3½ 91/ 3 3¼ 2½ 19 VP950 60 230 35 130 96W 1 ½ MNPT 304SS 45 3½ 91/ 3 3¼ 2½ 29 SHF-140 268 1014 107 406 320W 3 Flange 316SS 34 6 14 17½ 19½ 18 1 / 5 68 SHF-180 340 1285 137 519 400W 3 Flange 316SS 42½ 6 14 17½ 19½ 18 1 / 5 78 *Models listed above are North America (NEMA P-15) Voltage. Alternative voltages can be ordered by adding the voltage code to the end of the part number. /2 = EU CEE (CEE 7/7) /2A = AUS/NZ (AS 3112) /2B = UK (BS 1363). Example: VP600/2 Optional: VP600 & VP950 are available with temperature management: Order valve part # 440179 (sold separately.) PROFESSIONAL PLUS SERIES VIQUA STERILIGHT MONITORED ULTRAVIOLET SYSTEMS FEATURES & SPECIFICATIONS: UV Sensor for continual monitoring & continuous feedback of UV disinfection performance for added peace of mind Sensor reading output (4-20mA) available with cable: 260134 (sold separately) Visual lamp change count down timer & audible replacement reminder Ambient temperature: 36-104 F (2-40 C) Model No.* Flow Rate* Power Inlet/Outlet Reactor @ 16 mj/cm² @ 40 mj/cm² Consumption Connection Chamber Chamber Controller Material (L H D) VP600M 40 150 22 83 70W 1 MNPT 304SS 302/ 3 3½ 91/ 3 3¼ 2½ 19 VP950M 60 230 35 130 96W 1 ½ MNPT 304SS 45 3½ 91/ 3 3¼ 2½ 29 *Models listed above are North America (NEMA P-15) Voltage. Alternative voltages can be ordered by adding the voltage code to the end of the part number. /2 = EU CEE (CEE 7/7) /2A = AUS/NZ (AS 3112) /2B = UK (BS 1363). Example: VP600M/2 Optional: VP600M & VP950M are available with temperature management: Order valve part # 440179 (sold separately.)

VIQUA Professional & Professional Plus UV Systems NSF RATED PROFESSIONAL PLUS SERIES VIQUA UV MAX MONITORED ULTRAVIOLET SYSTEMS FEATURES & SPECIFICATIONS: NSF 55 Class A Certified for Disinfection Performance Flow meter & UV sensor for real-time UV dose measurement & reporting Sensor reading output (4-20mA) available with cable: 260134 (sold separately) Visual lamp change count down timer & audible replacement reminder Dynamic flow restrictor to ensure UV dose of 40 mj/cm² LightWise technology to lower lamp power during no flow periods to extend lamp life, reduce sleeve fouling, and lower energy consumption. Cool Touch Fan Inlet solenoid valve Operating pressure: 15-100 psi (1-6.89 bar) Ambient air temperature: 32-104 F (0-40 C) Part Number* Model Flow Rate** GPM L/Min Power Consumption Inlet/Outlet Connection Influent water temperature: 34-113 F (1-45 C) Installation Orientation: Vertical Only Reactor Chamber Material Chamber Controller (L H D) 650647 PRO10 10 38 120W 1¼ MNPT x 1 FNPT 316L SS 22 4 13 6½ 4½ 25 lbs 650653 PRO20 20 76 160W 1¼ MNPT x 1 FNPT 316L SS 31 4 13 6½ 4½ 28 lbs 650659 PRO30 30 113 230W 1¼ MNPT x 1 FNPT 316L SS 44 4 13 6½ 4½ 31 lbs *Part numbers listed above are North America (NEMA) Voltage. EU CEE (CEE 7-7) voltage is also available: contact us for details. **Flow Rates listed are based on 70% UVT water and 40 mj/cm² (NSF/EPA Standard). FOR PROFESSIONAL, PROFESSIONAL PLUS, AND NSF RATED SYSTEMS REPLACEMENT LAMPS, SLEEVES, & CONTROLLERS For System UV Lamp Quartz Sleeve Controller* VP600 S600RL-HO QSO-600 BA-ICE-C VP950 S950RL-HO QSO-950 BA-ICE-C SHF-140 S740RL-4C QS-012 BA-ICE-HF SHF-180 S950RL-4C QS-180 BA-ICE-HF VP600M S600RL-HO QSO-600 BA-ICE-CM VP950M S950RL-HO QSO-950 BA-ICE-CM 650647 (PRO10) 602854 602974 650709-003 650653 (PRO20) 602855 602975 650709-006 650659 (PRO30) 602856 602976 650709-009 ADDITIONAL Part # For System Description 254NM-C1 VP Plus UV Sensor OR-212 VP/SHF Lamp O-Ring (410867) RN-001 VP/SHF Retaining Nut 410076 VP Mounting Bracket/Clamp 602916 & 602896 PRO Top Bolt & Wire Form 650630 PRO Cool Touch Fan 002233 PRO Lamp O-Ring 603053 PRO Bottom Bolt (Includes Screw) 602988 PRO Sleeve Removal Tool 410982R-10 PRO10 Flow Meter Sensor 410982R-20 PRO20 Flow Meter Sensor 410982R-30 PRO30 Flow Meter Sensor 650580 PRO UV Sensor *Controller part numbers listed above are North America (NEMA) Voltage. Contact us for additional voltage options. OPTIONAL ADD-ON PARTS Part # For System Description 440179 VP Systems Temperature Management Valve 260134 Monitored Sensor Reading Output Cable

VIQUA VENDING Series - UV for Vending Machines The VIQUA Sterilight Vending UV systems have been specifically designed for requirements found in OEM application of vending machines and dispensing equipment. The unique design incorporating a separate reactor vessel and ballast lends itself to installation inside the equipment. This space saving design when coupled with the electronic ballast offer reduced heat build-up and application flexibility. FEATURES & SPECIFICATIONS Compact Space-Saving design optimal for installation inside of vending machines or dispensing equipment. 304 stainless steel reactor chamber Ambient temperature: 36-104 F (2-40 C) Mounting: Vertical or Horizontal Model No.* Flow Rate** @ 16 mj/cm² @ 40 mj/cm² Power Consumption Inlet/Outlet Connection (Inches) Chamber S2Q-PV 5.0 11 2 8 22W ½ MNPT 18½ 2½ 7 lbs S5Q-PV 11.0 42 4.5 17 30W ¾ MNPT 22 2½ 8 lbs *Models listed above are North America (NEMA P-15) Voltage. Alternative voltages can be ordered by adding the voltage code to the end of the part number. /2 = EU CEE (CEE 7/7) /2A = AUS/NZ (AS 3112) /2B = UK (BS 1363). Example: S5Q-PA/2 For System UV Lamp Quartz Sleeve Controller* S2Q-PV S330RL QS-330 BA-ICE-V S5Q-PV S463RL QS-463 BA-ICE-V Part # Description 410867-R Lamp O-Ring RN-001 Retaining Nut 4109958-R 2.5 Mounting Bracket 270276 Lamp Connector Base SP008 Lamp Connector Spring *North America voltage. Use Voltage Codes above for alternative voltages.

COMMERCIAL UV SYSTEMS NeoTech 2 Chamber Series 35 to 65 GPM INDUSTRY APPLICATIONS Pharmaceutical Micro-electronics Medical Sciences Water Remediation Hospitality APPLICATIONS INCLUDE Disinfection TOC Reduction Chlorine and Chloramines Removal Ozone Destruction Ultrapure Water Disinfection Our patented flow chamber design brings unparalleled performance in a compact size. This highly efficient reaction chamber saves thousands of dollars in capital and operation costs with superior disinfection capabilities and outstanding TOC reduction performance. Our products are made from the highest quality materials, exceeding the rigorous demands required for industrial grade equipment. SPECIFICATIONS AND ORDERING INFORMATION All Units include UV Monitor & CU-4-1 Controller Inlet & Outlet Connections: 1.5" Sanitary Fittings (NPT & Flange adapters are available) Number of Lamps: 1 Lamp Life Hours: 9000 Lamp Replacement: Dry, by Hand Operating Pressure: 150 psi (10 bar) Operating Temperature: 36-104 F (3-40 C) Model No. Max Flow Rate for Disinfection 1 Flow Rate for TOC Reduction 1 Operating Power Watts Non-Flow Standby Time: 60 Minutes Mounting: Horizontal or Vertical Water Contact Finish: Ra-15 Controller, Remote: NEMA 4X Real Time Dosimetry Alarms, Remote Control & Monitoring 185 & 254nm lamp standard (185 only is available upon request) Pressure Drop 2 Unit Overall 3 (Lbs) GPM M3/hr GPM M3/hr PSI NPM Length Height Depth D222 35 8 9.7 2.2 85 4 27.6k 23.6 8.2 6.3 30 D228 50 11 14.9 3.2 100 10 68.9k 29.6 8.2 6.3 33 D238 65 15 18.1 4.2 125 20 137.9k 39.6 8.2 6.3 42 1 Rated flows are based on 99% UVT 2 Pressure Drop defined at Rated Flow 3 is without water (dry weight) Replacement Lamps, Quartz Sleeves & Light Traps For System Light Kit Quartz Sleeve Kit Light Trap Kit D222 LK-22 QSK-22 UVLTK-2-S D228 LK-28 QSK-28 UVLTK-2-S D238 LK-38 QSK-38 UVLTK-2-S Note: Light Kits shown above are for 185&254nm (standard) lamps. For 185nm ONLY, use a -D at the end of the part #. Example: LK-22-D Other Spare Parts (for all 2 Systems) Part No. Description UVIM-3 UV Intensity Monitor CK2-1 Cleaning Kit for UVS2 Systems CU-4-1 Controller, 1 UV unit control (can be expanded to control up to 4 systems) BK-120 Ballast, Electronic, 120 VAC, 50-60 Hz BK-240 Ballast, Electronic, 240 VAC, 50-60 Hz BK-240-ENT Ballast, Electronic, 240 VAC, 50-60 Hz, 4-wire 4 Up to 4 systems can be run in parallel using a single controller. Contact us for design and quotation.

COMMERCIAL UV SYSTEMS NeoTech 3 Chamber Series 100 to 225 GPM INDUSTRY APPLICATIONS Pharmaceutical Beverage Municipal Drinking Water Food Processing Water Remediation Waste Water Hospitality APPLICATIONS INCLUDE Disinfection Chlorine and Chloramines Removal Ozone Destruction Our patented flow chamber design brings unparalleled performance in a compact size. This highly efficient reaction chamber saves thousands of dollars in capital and operation costs with superior disinfection performance capabilities using just a single HOLP Amalgam lamp. Our products are made from the highest quality materials, exceeding the rigorous demands required for industrial grade equipment. SPECIFICATIONS AND ORDERING INFORMATION All Units include UV Monitor & CU-4-1 Controller Inlet & Outlet Connections: 2" Sanitary Fittings (NPT & Flange adapters are available) Number of Lamps: 1 Lamp Life Hours: 9000 Lamp Replacement: Dry, by Hand Operating Pressure: 150 psi (10 bar) Operating Temperature: 36-104 F (3-40 C) Non-Flow Standby Time: 60 Minutes Mounting: Horizontal or Vertical Water Contact Finish: Ra-15 Controller, Remote: NEMA 4X Real Time Dosimetry Alarms, Remote Control & Monitoring 185 & 254nm lamp standard (185 only is available upon request) Model No. Max Flow Rate for Disinfection 1 Operating Power Watts Pressure Drop 2 Unit Overall 3 (Lbs) GPM M3/hr PSI NPM Length Height Depth D322 100 23 85 1 6.9k 24.1 9.0 7.3 39 D328 150 34 100 2 13.8k 30.1 9.0 7.3 43 D338 225 50 125 9.3 64.1k 40.1 9.0 7.3 51 1 Rated flows are based on 99% UVT 2 Pressure Drop defined at Rated Flow 3 is without water (dry weight) NeoTech Ultraviolet Systems are FCC approved and TUV Rheinland certified, meeting the requirements of CE, UL and CSA. Replacement Lamps, Quartz Sleeves & Light Traps For System Light Kit Quartz Sleeve Kit Light Trap Kit D322 LK-22 QSK-22 UVLTK-3-S D328 LK-28 QSK-28 UVLTK-3-S D338 LK-38 QSK-38 UVLTK-3-S Note: Light Kits shown above are for 185&254nm (standard) lamps. For 185nm ONLY, use a -D at the end of the part #. Example: LK-22-D 4 Up to 4 systems can be run in parallel using a single controller. Contact us for design and quotation. Other Spare Parts (for all 3 Systems) Part No. Description UVIM-3 UV Intensity Monitor CK3-1 Cleaning Kit for UVS3 Systems CU-4-1 Controller, 1 UV unit control (can be expanded to control up to 4 systems) BK-120 Ballast, Electronic, 120 VAC, 50-60 Hz BK-240 Ballast, Electronic, 240 VAC, 50-60 Hz BK-240-ENT Ballast, Electronic, 240 VAC, 50-60 Hz, 4-wire

COMMERCIAL UV SYSTEMS NeoTech 4 Chamber Series 300 to 500 GPM INDUSTRY APPLICATIONS Beverage Food Processing Municipal Drinking Water Water Remediation Waste Water Hospitality APPLICATIONS INCLUDE Disinfection Chlorine and Chloramines Removal Ozone Destruction Our patented flow chamber design brings unparalleled performance in a compact size. This highly efficient reaction chamber saves thousands of dollars in capital and operation costs, with superior disinfection performance capabilities using just two HOLP Amalgam lamps. Our products are made from the highest quality materials, exceeding the rigorous demands required for industrial grade equipment. SPECIFICATIONS AND ORDERING INFORMATION All Units include UV Monitor & CU-4-1 UV Controller Inlet & Outlet Connections: 3" Sanitary Fittings (NPT & Flange adapters are available) Number of Lamps: 2 Lamp Life Hours: 9000 Lamp Replacement: Dry, by Hand Operating Pressure: 150 psi (10 bar) Operating Temperature: 36-104 F (3-40 C) Non-Flow Standby Time: 60 Minutes Mounting: Horizontal or Vertical Water Contact Finish: Ra-15 Controller, Remote: NEMA 4X Real Time Dosimetry Alarms, Remote Control & Monitoring Model No. Max Flow Rate for Disinfection 1 Operating Pressure Drop 2 Unit Overall 3 GPM M3/hr Power Watts PSI NPM Length Height Depth (Lbs) D428 300 68 160 8.2 19.3k 30.5 11.39 8 55 D438 500 112 200 10.9 75.2k 40.5 11.39 8 63 1 Rated flows are based on 99% UVT 2 Pressure Drop defined at Rated Flow 3 is without water (dry weight) NeoTech Ultraviolet Systems are FCC approved and TUV Rheinland certified, meeting the requirements of CE, UL and CSA. Replacement Lamps, Quartz Sleeves & Light Traps For System Light Kit Quartz Sleeve Kit Light Trap Kit D428 LK-28 QSK-28 UVLTK-4-S D438 LK-38 QSK-38 UVLTK-4-S Note: Light Kits shown above are for 185&254nm (standard) lamps. For 185nm ONLY, use a -D at the end of the part #. Example: LK-28-D Other Spare Parts (for all 4 Systems) Part No. Description UVIM-3 UV Intensity Monitor CK4-1 Cleaning Kit for UVS3 Systems CU-4-1 Controller, 1 UV unit control (can be expanded to control up to 4 systems) BK-120 Ballast, Electronic, 120 VAC, 50-60 Hz BK-240 Ballast, Electronic, 240 VAC, 50-60 Hz BK-240-ENT Ballast, Electronic, 240 VAC, 50-60 Hz, 4-wire 4 Up to 4 systems can be run in parallel using a single controller. Contact us for design and quotation.

Technical Information & Installation Diagrams MICROORGANISMS DESTRUCTION CHART Use the below chart to determine the required UV dose (in mj/cm²) required to destroy specific microorganisms in water. Name Dose Name Dose Name Dose Bacteria Agrobacterium tumefaciens 8.5 Bacillus anthracis 8.7 Bacillus megatherium (vegetative) 2.5 Bacillus megatherium (spores) 2.5 Bacillus subtilis (vegetative) 11 Bacillus subtilis (spores) 58 Clostridium tetani 22 Corynebacterium diphtheria 6.5 Dysentery bacilli (diarrhea) 4.2 Escherichia coli (diarrhea) 6.6 Legionella bozemanii 3.5 Legionella dumoffii 5.5 Legionella gormanii 4.9 Legionella micdadei 3.1 Legionella longbeachae 2.9 Legionella pneumophila (legionnaires disease) 3.8 Leptospira interrogans (infectious jaundice) 6 Mycobacterium tuberculosis 10 Neisseria catarrahalis 8.5 Proteus vulgaris 6.6 Pseudomonas aeruginosa (laboratory) 3.9 Pseudomonas aeruginosa (environmental) 10.5 Rhodospirillum rubrum 6.2 Salmonella (food poisoning) 10 Salmonella enteritidis 7.6 TYPICAL INSTALLATIONS Bacteria Salmonella paratyphi (enteric fever) 6.1 Salmonella typhimurium 15.2 Salmonella typhosa (typhoid fever) 7 Saracen lutea 26.4 Serratia marcescens 6.2 Shigella dysentariae (dysentary) 4.2 Shigella flexneri (dysentary) 3.4 Shigella sonnei 7 Staphylococcus epidermidis 5.8 Staphylococcus aureus 7 Streptococcus faccalis 10 Streptococcus heaolyeous 5.5 Streptococcus lactis 8.8 Viridans streptococci 3.8 Vibro comma (cholera) 6.5 Mold Spores Aspergillus flavus (yellowish green) 99 Aspergillus glaucus (bluish green) 88 Aspergillus nigar (yellowish green) 330 Mucor ramosissimus (white-grey) 35.2 Penicillium digitatum (olive) 88 Penicillium expansum (olive) 22 Penicillium roqueforti (green) 26.4 Rhizopus nigricans (cheese mold) 220 Algae Chlorella vulgaris 22 Protozoa Nematode eggs 92 Paramecium 200 Giardia lamblia (3-log) 6-10 Cryptosporidium (3-log) <10 Viruses Influenza 6.6 Poliovirus (poliomyelitis) 7 Rotavirus 24 Tobacco mosaic virus 440 Bacteriophage (E. Coli) 6.6 Hepatitis 8 Yeast Baker s yeast 8.8 Brewer s yeast 6.6 Common yeast cake 13.2 Saccharomyces ellipsoideus 13.2 Saccharomyces sp 17.6 *UV dose shown in mj/cm²