WO P NF L M 407c Spec Submittal

Similar documents
WO P NF L M 407c Spec Submittal

Chiller installation, contractor s scope of work:

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

How to Select and Size a Chiller

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

APPLICATION FOR OSHPD SPECIAL SEISMIC CERTIFICATION PREAPPROVAL (OSP)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Precise Temperature Control; Compact Footprint

NQ Series Portable Chillers

MAC-120HE-03 Air-Cooled Chiller

RECORD SUBMITTAL COVER SHEET

PACKAGED AIR COOLED Product Data Catalog

OACS Outdoor Air-Cooled Central Chillers

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Energy-Saving Industrial Water Chillers

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Central Chillers TS Series

Split System Condensing Units and Remote Chillers

Outstanding Performance; Application Flexibility

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

Split System Condensing Units and Remote Chillers

Part IV: Flow Side Components Flow Diagram

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

C13-Series Engineering Guide

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Liebert CSU3000 Chiller

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Temptek Auxiliary Equipment

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Air-Cooled SEMIHERMETIC

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

MEDICAL CHILLER SYSTEMS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

PURESTREAM CHILL-CUBE TM BY FRIULAIR

SPECTRACOOL Indoor & Outdoor Air Conditioners

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

30GT FLOTRONIC AIR-COOLED CHILLERS

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

Advance Release September 2009

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

GP SERIES Packaged Chillers

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Guide Specifications for InRow Direct Expansion

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

ULTIMATE ENERGY SAVING TECHNOLOGY

Call us today! (800)

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Call us today! (800)

VertiCool Aurora Engineering Guide

Precision Air-Conditioning Units 60 Hz. Technical Data

30GN FLOTRONIC II AIR-COOLED CHILLERS

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

horizontal air discharge outdoor discus condensing unit

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Call us today! (800)

REFRIGERATION PRODUCTS

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

OTC, OTM and OTI Series Options

Air cooled industrial chillers

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

NEW CHILLER SCHEDULE

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Precision Air-Conditioning Units 60 Hz. Technical Data

Kramersaver Air Cooled Condensing Units

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

PDF Created with deskpdf PDF Writer - Trial ::

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Air-Cooled Condensing Units with Compact Screw Compressors

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Transcription:

WO2 10000 2P NF L M 407c Spec Submittal

Overview: For Use With: WO2-10000-2P-NF-L-M-407c (45kW) Siemens Aera XJ, Espree, Symphony MRs Standard Chiller Siemens Part Number: Function: DTSWO2100MR45 Support medical functions by maintaining process fluid with tight temperature and flow tolerances while meeting the varying heat loads of critical imaging systems. Features: Dual refrigeration circuits and redundant compressors for varying capacity control Redundant fluid pumps to provide backup in case of a motor failure Open atmosphere system allows maintenance without interrupting patient care Coastal Chiller Siemens Part Number Function: Features: DTSWO2100MR45C Protects chiller installed less than 30 miles from salt water coast All Standard chiller features plus: Stainless steel cabinet upgrade E-Coated condenser coil Low Ambient Chiller Siemens Part Number: DTSWO2100MR45L Function: Allow chiller operation in ambient ranges of -40 F to 122 F Features: All Standard chiller features plus: Refrigeration heat tape Additional heater in electrical cabinet Heater added to fluid reservoir

General Specifications WO2-10000(800874) Width: IN/CM 113/287.02 Height: IN/CM 84.5/214.63 Depth: IN/CM 44/112 Dry weight: LB/KG 2940/1333.56 Operational weight: LB/KG 3740/1696.44 Max. ambient temperature: F/ C 122/50 Min. ambient temperature: F/ C -20/-28.89-40/-40 Condenser air flow approx.: CFM 12,000 Fluid tank capacity: GAL/LTR 100/378.54 Coolant connections: NPTF 2.0 Fluid Specifications Coolant: N/A Water/glycol 50/50 Coolant outlet temperature: F/ C 48/8.89 Coolant temperature accuracy: F/ C 1.8/1 Coolant flow: GPM/LPM 21+/-2 / 80+/-2 Max coolant pressure: PSI/BAR 70/4.83

Refrigeration Specifications Net cooling capacity: BTU/kW 153,540/45 Refrigerant: N/A R407C Refrigerant Charge: LB/KG 50/22.68 Electrical Specifications (460/3/60) FLA 56A MOP MCA Disconnect Fuses Compressor FLA Compressor LRA 90A 65A 70A 20A 101A Pump FLA 6.3A Fan FLA 1.2A Control Voltage SCCR Note: 24v AC 5kA For 208v or 230v, please consult the manufacturer for specifications!

Standard Componentry Details Cabinet Galvanized, NEMA 4 electrical enclosure, site glass/fill tube Circuits Compressor(s) Condenser(s) Evaporator(s) Fan(s) Pump(s) Controller Certifications Dual Refrigeration Circuit, Dual Fluid Circuit Two, 10hp Hermetic Scroll Two, oversized, air-cooled, with vertical air discharge and cleanable air filters Two, Copper-brazed, 316 Stainless Steel Four, 0.5hp TEFC Two, 3hp, non-ferrous, centrifugal Carel PCO5 controller with Carel pgd1 remote display with 150 of cable (requires ½ conduit) Compliant with UL1995 standards; OSHPD, CE, and CSA available as options Upgrades (if applicable) Coastal (800403), Low Ambient (800156) Add Ons/Options Filter Flow Meter Kit Kit that provides filtration and 0-50GPM flow meter on inline piping. Installed indoors between chiller and MR equipment. Isolation Springs City Water Bypass Panel Long Distance Remote Kit BMS Card Booster Pump Glycol Set of vibration isolation springs. Recommended to be used when installing a chiller on a roof top. Helps eliminate vibration through the rooftop. Panel that allows switchover to city water backup in case of chiller failure. Multiple types available. Consult DTS for details. Increases distance remote display can be ran from chiller to MR control room from 150 up to 400 Card that allows chiller to tie into customer BMS system. Various types available. Consult DTS for details. In-line pump that allows chiller to provide adequate flow to process for systems that exceed standard pipe allowances. Propylene or Ethylene available at various concentrations in 55 gallon drums or 5 gallon pails.

Version Revision Date Description of Change Changes Made By (Name & Title): 001 02/15/2017 Creation of document Kyle Hastings, Medical Service Manager