Micro Wall Wash Trimless - MWL

Similar documents
USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

80 Watts FLANGE FINISH

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

OPTIONAL LENS 2 FLANGE FINISH

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

SliverLED Round Downlight, 1 Regress SR11

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

NanoLED NXT Cylinder LNRP3 Surface

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

PROJECT INFORMATION FLANGE FINISH

1" Regress Trim DELIVERED PERFORMANCE - Downlight

PROJECT INFORMATION PROJECT

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

Field changeable between Trimmed / Trimless / Millwork

BeveLED 2.1 PROJECT INFORMATION

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION PROJECT DATE TYPE

DATE TYPE 40 DELIVERED PERFORMANCE

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

Field changeable between Trimmed / Trimless / Millwork

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

BeveLED Cylinder LBRP6 Surface

SliverLED Round Adjustable, Wet Location SR21W

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

BeveLED Cylinder LBRP6 Pendant

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

True Zero Conceal - Z3SA-C 3 Square Adjustable

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED Mini Trimless Acoustical - B3RDP

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3SD 3 Square Downlight

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

BeveLED Mini - B3RD 3 Round Downlight

BeveLED Mini - B3RA 3 Round Adjustable

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

BeveLED Cylinder LBRP6 Surface

PROJECT DATE FLANGE FINISH

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Classix 6" 6" Round Adjustable C3

Evoke Round Adjustable C3

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Adjustable HP

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Square Downlight

Grüv Flare Regressed. Recessed Linear LED

Performance Chart Electrical Data

Evoke Square Adjustable HP

Hornet HP. Square Glass Downlight

Evoke Square Downlight

Evoke Square Adjustable C3M

Hornet HP. Round Glass Downlight

Essenza. Round Downlights

Grüv Flare Regressed. Recessed Linear LED

Essenza. Square Downlights

Velato. Recessed Slot Adjustable Multiples

Hornet HP. Semi-Recessed 4-Light Square Multiple

Classix 6" 6" Round Adjustable C3

Evoke Square Downlight

Classix 6" 6" Round Lens Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

Classix 6" 6" Round Lens Wall Wash

Hornet HP. Recessed 4-Light Square Multiple

Classix 6" 6" Round Lens Wall Wash

Transcription:

Micro Wall Wash Trimless MWL MWL02 MWL04 MWL06 MWL08 MWL12 Meet Micro our smallest downlight which artistically blends technology and sleek design. Micro provides a unique aesthetic for downlights, with a new linear form factor and jewellike presence in the ceiling plane. Ceilings are powerful yet whisper quiet with Micro s minimal aperture size of just 1.25. Available as a wall wash in 2, 4, 6, 8 and 12 cell configurations, Micro brings elegance and clean style to lobbies, corporate headquarters, hotels and residential applications. FEATURES Micro downlights offer a new form factor for a modern and innovative downlight aesthetic Plaster frame trims are compatible with sheetrock mudin ceiling applications Industry leading illumination and craftsmanship New construction and remote driver housing options for easy installation in any site condition MICRO WALL WASH PERFORMANCE DATA Classic White DELIVERED PERFORMANCE: MWL02 2 CELL 8W MWL04 4 CELL 13W MWL06 6 CELL 21W MWL08 8 CELL 27W MWL12 12 CELL 41W Color Rendering Index Source Lumens: White Bevel Performance Lumens Per Watt: Delivered Lumens: Black Bevel Performance Lumens Per Watt: Delivered Lumens: Color Consistency: 80+ 750 63 500 52 400 90+ 625 53 400 44 350 Performance data based on 3000K 80+ 90+ 80+ 90+ 80+ 90+ 1475 1250 2200 1850 2900 2425 70 59 74 62 75 63 1000 850 1550 1300 2075 1750 58 49 61 51 62 52 825 700 1275 1075 1700 1450 2Step MacAdam Ellipse 80+ 90+ 4675 3925 76 64 3125 2625 63 53 2600 2175 CORRELATED COLOR TEMPERATURE 2700K Classic White 3000K 3500K 4000K Color Rendering Index: 80+ 90+ 80+ 90+ 80+ 90+ 80+ 90+ Multiplier for Lumen Output: 0.93 0.79 1.00 0.84 1.00 0.84 1.07 0.93 Page 1 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

Micro Wall Wash Trimless MWL TRIM DETAILS MWL02 2 CELL 11/4 21/2 Available Housing : Micro Wall Wash with Integral Driver Housing Page 3 Micro Wall Wash with Remote Driver Housing Page 5 3/8 MWL04 4 CELL 5 11/4 3/8 MWL06 6 CELL 71/2 11/4 3/8 MWL08 8 CELL 10 11/4 3/8 MWL12 12 CELL 15 Bevel Finish 11/4 3/8 Page 2 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

HOW TO SPECIFY Micro Wall Wash Trimless with Integral Driver Housing MWL FAMILY COLOR CHOICES MWL NC Micro Wall Wash Trimless Number of Cells Size / Wattage Color Temperature Bevel Finish Mounting Voltage Dimming Driver Accessories (Optional) INTEGRAL HOUSING MWL Micro Trimless Wall Wash 02 2 Cell 04 4 Cell 06 6 Cell 08 8 Cell 12 12 Cell Classic White Remote only See page 5 13H1 13W 21H1 21W 27H1 27W 41H1 41W Please note that MWL02 (8W) is not available with Integral driver housing see page 5 27KS 2700K, 80+ CRI 27KH 2700K, 90+ CRI 30KS 3000K, 80+ CRI 30KH 3000K, 90+ CRI 35KS 3500K, 80+ CRI 35KH 3500K, 90+ CRI WH White Matte BL Black Matte BG Black Specular SM Silver Matte SG Silver Specular NC New Construction Housing, Integral Driver UNV 120V277V 120V For use with Universal Voltage 120V 277V D2 010V dim, 10% (provided standard) For use with 120V only D19 Phase dimming 1%, 120V only CB27 27 CChannel Bars CB52 52 CChannel Bars NOTE: Emergency battery not available with Integral driver housing remote only see page 5 40KS 4000K, 80+ CRI 40KH 4000K, 90+ CRI 2Step MacAdam Ellipse Color Consistency is standard for all BZ Bronze Specular RG Rose Gold Specular INTEGRAL SPECIFICATIONS FIELD REPLACEABLE LIGHT ENGINE is serviceable through the aperture with a Philips screwdriver. All Classic White light engines feature industryleading color consistency within a 2Step MacAdam Ellipse. FIELD REPLACEABLE 010V, 100%10% solid state electronic constant current D2 dimming driver with a high power factor provided standard and sources 2mA (MWL12 sources 4mA). Driver complies with IEEEC62.41 surge protection and is serviceable from above the ceiling. Other dimming drivers optionally available. WEIGHT Weights do not include optional channel bar mounting hardware. NC Integral driver housing with trim: MWL04 MWL06 MWL08 MWL12 7LB 9LBS 9LBS 14.5LBS HOUSING, INTEGRAL Micro new construction housing is fabricated of 18 and 20 gauge steel with black finish. Thru wire junction box with 610 knockouts features a slide mechanism that allows for easy belowceiling access for service. MWL NC housing accepts D2 and D19 drivers only. MOUNTING Micro fixtures that are provided with a spackle frame are designed for use in sheetrock, mudin ceiling applications up to 1 thick maximum. Butterfly brackets and adjustable nailer bars extendible from 14 to 24 centers with integral nails are provided for attachment to building structure. Butterfly brackets can be relocated in the field to adjacent sides of housing. Cchannel bars are optionally available. WARRANTY Based on IESNA LM802008, Micro has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. CEILING CUTOUT MWL04: 2 x 55/8 MWL06: 2 x 81/8 MWL08: 2 x 105/8 MWL12: 2 x 155/8 LISTINGS Dry/Damp location. NRTL/CSAUS tested to UL standards. IBEW union made. NOTES Not for use in corrosive environment. Use of pressure washer voids warranty. Ambient temperatures at fixture location should not exceed 40 C during normal operation. Not for use in acoustical ceiling tiles. PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79. Page 3 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

Micro Wall Wash Trimless with Integral Driver Housing MWL NEW CONSTRUCTION HOUSING NC MWL04 Note: Integral housing butterfly brackets are field adjustable for 15/16 of vertical travel and can be relocated to adjacent sides in the field 5 1 8" 1 2 1" Max. Ceiling Thickness 3 8 Typ. MWL04 = 6 15 16 MWL06 MWL08 MWL12 Note: Integral housing butterfly brackets are field adjustable for 15/16 of vertical travel and can be relocated to adjacent sides in the field 4 1 2" 1 2 1" Max. Ceiling Thickness 3 8 Typ. MWL06 = 11 15 16 MWL08 = 11 15 16 MWL12 = 16 15 16 1 13 16" 12 5 8" 1 13 16" 1 13 16" 12 5 8" 1 13 16" NOTE: MWL NC housing accepts D2 and D19 dimming drivers only. patent pending slide mechanism provides easy access to internal components for service and maintenance. Installed Position / Light Engine Service Junction Box Service Position Driver service position Page 4 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

HOW TO SPECIFY Micro Wall Wash Trimless with Remote Driver Housing MWL 1. Specify fixture part number and options. FAMILY COLOR CHOICES MWL RM Micro Wall Wash Trimless MWL Micro Trimless Wall Wash Number of Cells 02 2 Cell 04 4 Cell Size / Wattage REMOTE Classic White 08H1 8W 13H1 13W Color Temperature 27KS 2700K, 80+ CRI 27KH 2700K, 90+ CRI Bevel Finish WH White Matte BL Black Matte Mounting RM Remote Driver Housing Accessories (Optional) CB27 27 CChannel Bars CB52 52 CChannel Bars Power Supply Must Be Specified 06 6 Cell 08 8 Cell 12 12 Cell 21H1 21W 27H1 27W 41H1 41W 30KS 3000K, 80+ CRI 30KH 3000K, 90+ CRI 35KS 3500K, 80+ CRI 35KH 3500K, 90+ CRI BG Black Specular SM Silver Matte SG Silver Specular 40KS 4000K, 80+ CRI 40KH 4000K, 90+ CRI 2Step MacAdam Ellipse Color Consistency is standard for all BZ Bronze Specular RG Rose Gold Specular 2. Specify Remote Power Supply Specify remote power supply part number in table below RPA Type Code Fixture Quantity per Remote Power Supply Fixture Size and Wattage Voltage Remote Dimming Driver Type and Dim Level Remote Emergency Option RPA Micro Remote Power Supply MULTI CHANNEL REMOTE POWER SUPPLIES 08 Fixtures Max 04 Fixtures Max 03 Fixtures Max 02 Fixtures Max 08H1 2 Cell 8W 13H1 4 Cell 13W 21H1 6 Cell 21W 27H1 8 Cell 27W 41H1 12 Cell 41W SINGLE CHANNEL REMOTE POWER SUPPLIES 02 Fixtures 01 Fixture 08H1 2 Cell 8W 08H1 2 Cell 8W 13H1 4 Cell 13W 21H1 6 Cell 21W 27H1 8 Cell 27W 41H1 12 Cell 41W UNV 120V 277V UNV 120V 277V 120V D6E Eldo 010V, 1% D6F Eldo 010V, 1% D7E Eldo DALI, 1% D8E Eldo DMX, 1% D2 010V dim, 10% D4 Lutron 3wire/ECO, 1% D6E Eldo 010V, 1% D6F Eldo 010V, 1% D3 Lutron 2wire, 1% D19 Phase 2wire, 1% (1) 1 Not available with 08H1 EM7 Emergency Battery provides emergency power to one fixture per power supply and requires remote enclosure (by others) with a minimum size of 14.5 L x 6.5 W x 3 H. Emergency battery is not available with 2cell MWL0208H1 Page 5 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

SEE DIMMING COMPATIBILIT ATIBILITY SHEET FOR DETAILS HOW TO SPECIFY Micro Wall Wash Trimless with Remote Driver Housing MWL REMOTE HOUSING SPECIFICATIONS FIELD REPLACEABLE LIGHT ENGINE is serviceable through the aperture with a Philips screwdriver. All Classic White light engines feature industryleading color consistency within a 2Step MacAdam Ellipse. WEIGHT Weights do not include optional channel bar mounting hardware or remote drivers. RM Remote driver tray with trim weights: MWL02 MWL04 MWL06 MWL08 MWL12 1LB 2LBS 2.5LBS 3LBS 3.5LBS REMOTE HOUSING New construction tray is fabricated of 20 ga. steel construction and is supplied with quick connects for use with remotely located driver. Driver is provided separately for remote location on site, enclosure to be provided by others. REMOTE LOCATION All remote dimming driver options must be clearly specified in the RP table. Remote power supplies require enclosures by others that meet local codes and must be located in an accessible service panel within 100ft of the light fixture; see remote driver details for coordination of enclosure sizes. All dimming drivers comply with IEEE C62.41 surge protection. REMOTE LOCATION EMERGENCY Remote emergency battery IOTA ILBCP07 provides 200mA to one fixture for 90 minutes. When used with multichannel power supplies, emergency battery supplies power to 1 fixture only through channel 1. Remote power supplies with EM option require an enclosure with minimum size of 14.5 L x 6.5 W x 3 H by others that meets local codes. Battery is not available with 08H1. MOUNTING Micro fixtures that are provided with a spackle frame are designed for use in sheetrock, mudin ceiling applications up to 1 thick maximum. Butterfly brackets and adjustable nailer bars extendible from 14 to 24 centers with integral nails are provided for attachment to building structure. Butterfly brackets can be relocated in the field to adjacent sides of housing. Cchannel bars are optionally available. WARRANTY Based on IESNA LM802008, Micro has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. Warranty is void if Micro is used with any power supply other than that which is provided by. CEILING CUTOUT MWL04: 2 x 31/8 MWL04: 2 x 55/8 MWL06: 2 x 81/8 MWL08: 2 x 105/8 MWL12: 2 x 155/8 LISTINGS Dry/Damp location. NRTL/CSAUS tested to UL standards. IBEW union made. NOTES Not for use in corrosive environment Use of pressure washer voids warranty Ambient temperatures at fixture location should not exceed 40 C during normal operation. Not for use in acoustical ceiling tiles. PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79. 2Cell Micro Remote Power Supply Requirements and Wiring Diagrams 2Cell can be wired in homeruns (wiring diagram A) or in series pairs (wiring diagram B). If you want to connect 8 fixtures maximum per power supply select from Minimum the following options: Enclosure Size Required Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNVD6E Eldo 010V, 1% UNVD6F Eldo 010V, 1% RPA0808H1 18/16 10.375 W x 4 L x 2 H UNVD7E Eldo DALI, 1% UNVD8E Eldo DMX, 1% If you want to connect 12 fixtures maximum per power supply select from Minimum the following options: Enclosure Size Required Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNVD2 010V dim, 10% 14/12 5.75 W x 2.625 L x 2 H UNVD4 Lutron 3wire/ECO, 1% 14/12 6.25 W x 4 L x 2 H RPA0108H1 UNVD6E Eldo 010V, 1% RPA0208H1 UNVD6F Eldo 010V, 1% 18/16 6.25 W x 4 L x 2 H 120VD3 Lutron 2wire phase, 1% 14/12 6.25 W x 4 L x 2 H H * Wire gauge 14/12 = Maximum distance from light fixture to remote power supply is 100 using 12 gauge wire, 50 using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fixture to remote power supply is 100 using 16 gauge wire, 50 using 18 gauge wire. Requirements and Wiring Diagrams for MDF02 MWF02 MDL02 MWL02 MDM02 MWM02 HOMERUN USE FOR WIRING S MDF02M DP02 MDF04M DP04 MDF06M MDF08M DP06 DP08 RP2 RPA REMOTE POWER SUPPLY A INPUT WIRES DIMMING COMPATIBILIT ATIBILITY SEE SHEET DIMMING FOR DETAILS COMPATIBILTY SHEETS FOR DETAILS + + SERIES USE ONLY FOR WIRING S MDF02 MDP02 (2) S IN SERIES RPA RP2 REMOTE POWER INPUT WIRES SUPPLY SEE DIMMING SUPPLY COMPATIBILTY SHEETS FOR DETAILS B + + 1 + 2 Page 6 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

HOW TO SPECIFY Micro Wall Wash Trimless with Remote Driver Housing MWL 4, 6, and 8Cell Micro Remote Power Supply Requirements and Wiring Diagrams Must be wired in homeruns per wiring diagram A below. If you want to connect 34 fixtures maximum per power supply select from the following options: Minimum Enclosure Size Required (by others) Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** RPA0413H1 RPA0421H1 RPA0327H1 If you want to connect 1 fixture maximum per power supply select from the following options: Minimum Enclosure Size Required (by others) Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNVD2 010V dim, 10% 14/12 7 W x 2.625 L x 2 H RPA0113H1 RPA0121H1 RPA0127H1 * Wire gauge 14/12 = Maximum distance from light fixture to remote power supply is 100 using 12 gauge wire, 50 using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fixture to remote power supply is 100 using 16 gauge wire, 50 using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fixture. HOMERUN USE FOR WIRING S MDF02M DP02 MDF04M DP04 MDF06M MDF08M DP06 DP08 RP2 RPA REMOTE + POWER INPUT WIRES SUPPLY DIMMING COMPATIBILIT ATIBILITY SEE SHEET DIMMING FOR DETAILS COMPATIBILTY SHEETS FOR DETAILS A UNVD6E Eldo 010V, 1% UNVD6F Eldo 010V, 1% UNVD7E Eldo DALI, 1% UNVD8E Eldo DMX, 1% + 18/16 10.375 W x 4 L x 2 H 14.5" W x 6.5" L x 3" H UNVD4 Lutron 3wire/ECO, 1% 14/12 6.25 W x 4 L x 2 H UNVD6E Eldo 010V, 1% UNVD6F Eldo 010V, 1% 18/16 6.25 W x 4 L x 2 H 14.5" W x 6.5" L x 3" H 120VD3 Lutron 2wire phase, 1% 14/12 6.25 W x 4 L x 2 H 120VD19 Hatch 2wire phase, 1% 14/12 5.75 W X 2.625 L X 2 H Requirements and Wiring Diagrams for MDF04 MWF04 MAF04 MDF06 MWF06 MAF06 MDF08 MWF08 MAF08 MDL04 MWL04 MAL04 MDL06 MWL06 MAL06 MDL08 MWL08 MAL08 MDM04 MWM04 MAM04 MDM06 MWM06 MAM06 MDM08 MWM08 MAM08 12Cell Micro Remote Power Supply Requirements and Wiring Diagrams Must be wired with 2 homeruns per fixtures as shown in wiring diagram C below. If you want to connect 2 fixtures maximum per power supply select from the following options: Minimum Enclosure Size Required (by others) Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNVD6E Eldo 010V, 1% RPA0241H1 UNVD6F Eldo 010V, 1% UNVD7E Eldo DALI, 1% 18/16 10.375 W x 4 L x 2 H 14.5" W x 6.5" L x 3" H UNVD8E Eldo DMX, 1% If you want to connect 1 fixture maximum per power supply select from Minimum Enclosure Size Required the following options: (by others) Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNVD2 010V dim, 10% 14/12 8 W x 6.75 L x 2 H UNVD4 Lutron 3wire/ECO, 1% 14/12 8 W x 6.75 L x 2 H RPA0141H1 UNVD6E Eldo 010V, 1% UNVD6F Eldo 010V, 1% 18/16 8 W x 6.75 L x 2 H 14.5" W x 6.5" L x 3" H 120VD3 Lutron 2wire phase, 1% 14/12 8 W x 6.75 L x 2 H 120VD19 Hatch 2wire phase, 1% 14/12 7.25 W x 4 L x 2 H * Wire gauge 14/12 = Maximum distance from light fixture to remote power supply is 100 using 12 gauge wire, 50 using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fixture to remote power supply is 100 using 16 gauge wire, 50 using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fixture. 2X USE HOMERUN ONLY FOR WIRING S MDF12 MDP12 EACH REQUIRES (2) RUNS RP2 RPA REMOTE POWER SUPPLY INPUT WIRES DIMMING COMPAT MPATIB SEE DIMMING IBILITY SHEET FOR DETAILS COMPATIBILTY SHEETS FOR DETAILS C ++ + + Requirements and Wiring Diagrams for MDF12 MWF12 MAF12 MDL12 MWL12 MAL12 MDM12 MWM12 MAM12 Page 7 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

HOW TO SPECIFY Micro Wall Wash Trimless with Remote Driver Housing MWL REMOTE HOUSING RM MWL02 MWL04 MWL06 MWL08 MWL12 Note: Remote housing butterfly brackets are field adjustable for 15/16 of vertical travel and can be relocated to adjacent sides in the field 3 1 4 1 2 Min to 1 Max. Ceiling Thickness 3 8 Typ. MWL02 = 4 5 8 MWL04 = 6 15 16 MWL06 = 9 7 16 MWL08 = 11 15 16 MWL12 = 16 15 16 1 13 16 MWL02 = 4 3 4 MWL04 = 4 13 16 MWL06 = 6 9 16 MWL08 = 7 3 4 MWL12 = 8 13 16 1 13 16 Page 8 usailighting.com 2016., LLC. All rights reserved. Patents pending., Beve, are registered trademarks of, LLC Revised 03/23/2018

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D2 / DIML2 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D2 / DIML2 : 010V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLSEXPDIMFLV 100% 10% fixture specification Crestron DIN Rail dimmer DIN4DIMFLV4 100% 10% sheet to determine Crestron DIN Rail analog output module DINA08 100% 10% number of fixtures per Crestron 8 Channel dimmer module GLXDIMFLV8 100% 10% dimmer. Max number Crestron 8 Channel dimmer module GLXPDIMFLV8 100% 10% of fixtures is limited by Leviton IllumaTech dimmer IP710DLX 100% 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% 10% Lutron Diva DVTVXX 100% 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 010V D2 / DIML2 010V DIMMING W/RELAY TO SWITCH POWER 010V () 010V (+) SWITCHED HOT GRAY PURPLE V NOTE: If switched, nondimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 010V w/ POWER SWITCHING D2 / DIML2 010V DIMMING (NO RELAY) 010V () 010V (+) SWITCHED HOT GRAY PURPLE V NOTE: If switched, nondimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND www.usailighting.com 2016., LLC. All rights reserved. I22642 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D3 / DIML3 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D3 / DIML3 : Lutron HiLume ASeries 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W 80W ETC Sensor+ Cabinet ELV10 100% 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF26ND120 100% 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF210ND120 100% 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD6NA 100% 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD6ND 100% 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD10ND 100% 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD10NXD 100% 1% 1 13 1 6 Lutron Stanza dimmer SZ6ND 100% 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD6NA 100% 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD10ND 100% 1% 1 6 1 3 Lutron myroom DIN power module MQSE4A1D 100% 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJWPM6D120 100% 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE4A1D 100% 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWIWPM6D120 100% 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR, QSGRJ 100% 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX3100, GRX3500 100% 1% 1 26 1 13 Lutron RPM4U module HWRPM4U120, LPRPM4U120 100% 1% 1 26 1 13 Lutron RPM4A module HWRPM4A120, LPRPM4A120 100% 1% 1 26 1 13 Lutron GP dimming panels Various 100% 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL253P 100%1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL253P, DVSCCL253P 100%1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT250M, GTJ250M 100%1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL250 100%1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V GROUND ONLY FOR SWITCHES WITH www.usailighting.com 2016., LLC. All rights reserved. I22643 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D4 / DIML4 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 : Lutron HiLume ASeries Driver with 3Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W 80W ETC Sensor+ Cabinet D20 Dimming module 100% 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% 1% 1 53 1 26 Lutron Nova T NTF10 100% 1% 1 41 1 20 Lutron Nova T NTF103P 100% 1% 1 20 1 10 Lutron Nova NF10 100% 1% 1 41 1 20 Lutron Nova NF103P 100% 1% 1 20 1 10 Lutron Vareo VF10 100% 1% 1 20 1 10 Lutron Skylark SF10P, SF103P 100% 1% 1 20 1 10 Lutron Diva DVF103P, DVSCF103P 100% 1% 1 20 1 10 Lutron Ariadni AYF103P 100% 1% 1 20 1 10 Lutron Vierti VTF6A 100% 1% 1 15 1 7 Lutron Maestro MAF6AM, MSCF6AM 100% 1% 1 15 1 7 Lutron Maestro Wireless MRF2F6ANDV 100% 1% 1 15 1 7 Lutron RadioRA 2 RRDF6ANDV 100% 1% 1 15 1 7 Lutron HomeWorks QS HQRDF6ANDV 100% 1% 1 15 1 7 Lutron Interfaces PHPM3F120, PHPM3FDV 100% 1% 1 41 1 20 Lutron GP Dimming Panels Various 100% 1% 1 41 1 20 277V Only 40W and Less 41W 80W ETC Sensor+ Cabinet D20 Dimming module 100% 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% 1% 1 53 1 26 Lutron Nova T NTF10277 100% 1% 1 44 1 22 Lutron Nova T NTF103P277 100% 1% 1 33 1 16 Lutron Nova NF10277 100% 1% 1 44 1 22 Lutron Nova NF103P277 100% 1% 1 33 1 16 Lutron Skylark SF12P277, SF12P2773 100% 1% 1 33 1 16 Lutron Diva DVF103P277, DVSCF103P277 100% 1% 1 33 1 16 Lutron Ariadni AYF103P277 100% 1% 1 44 1 22 Lutron Vierti VTF6A 100% 1% 1 33 1 16 Lutron Maestro MAF6AM277, MSCF6AM277 100% 1% 1 20 1 10 Lutron Maestro Wireless MRF2F6ANDV 100% 1% 1 33 1 16 Lutron RadioRA 2 RRDF6ANDV 100% 1% 1 33 1 16 Lutron HomeWorks QS HQRDF6ANDV 100% 1% 1 33 1 16 Lutron Interfaces PHPM3FDV 100% 1% 1 88 1 44 Lutron GP Dimming Panels Various 100% 1% 1 88 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page www.usailighting.com 2016., LLC. All rights reserved. I22644 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D4 / DIML4 Continued NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 : Lutron HiLume ASeries Driver with 3Wire FL Control / Dimming Driver Wiring (Dims down to 1%) GROUND DIMMER: 3 WIRE PHASE DIMMED HOT SWITCHED HOT D4 / DIML4 3 WIRE PHASE DIMMING CAP UNUSED ECOSYS WIRES PURPLE GRAY PURPLE ORANGE V D4 / DIML4 : Lutron HiLume ASeries Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W 80W Lutron PowPak dimming module RMJECO32DVB 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN1ECOS, QSN2ECOS 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ_E, QSGR_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. E2 E1 D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 WALL CONTROL CAP UNUSED ORANGE WIRE PURPLE GRAY PURPLE ORANGE V www.usailighting.com 2016., LLC. All rights reserved. I22644 Revised 03/22/2017

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIMMING COMPATIBILITY SELECTION GUIDE D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmicstyle dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 010V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 010V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP20 99% 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP20 99% 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN4T16S 100% 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% 0.1% 1% dimmer. Lutron Interfaces GRXTVI w/ GRX3503 100% 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% 0.1% 1% enlighted Control Unit CU3E1R 100% 0.1% 1% D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmicprogrammed dimming drivers for use with linearstyle dimming controls (e.g., Crestron, nonlutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 010V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 010V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F BushJaeger Electronic potentiometer 2112U101 100% 0.1% 1% Jung Electronic potentiometer 24010 100% 0.1% 1% Leviton Iluma Tech dimmer IP710DLX 100% 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% 0.1% 1% Merten Electronic potentiometer 5729 100% 0.1% 1% Pass & Seymour Titan CD4FBW 100% 0.1% 1% Watt Stopper Miro DCLV1 100% 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% 0.1% 1% ABB ibus SD/S 2.16.1 100% 0.1% 1% Crestron Modules GLXDIMFLV8, GLXPDIMFLV8 100% 0.1% 1% Crestron Green Light GLPACDIMFLV4, GLPACDIMFLV8 100% 0.1% 1% Crestron Green Light Power Pack GLPPDIMFLVEXPM, GLPP1DIMFLV2EXPM, GLPP1DIMFLV3EXPM 100% 0.1% 1% Crestron DIN Rail Analog Output Module DINA08 100% 0.1% 1% Crestron DIN Rail 010V Fluorescent Dimmer DIN4DIMFLV4 100% 0.1% 1% Crestron ilux 010V Dimmer Expansion Module CLSEXPDIMFLV 100% 0.1% 1% enlighted Control Unit CU3E1R 100% 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 D6 / DIML6 010V DIMMING W/RELAY TO SWITCH POWER 010V DIMMING (NO RELAY) CLASS 2 CONTROL WIRES DIMMER: 010V RELAY 010V () 010V (+) SWITCHED HOT GRAY PURPLE V GROUND DIMMER: 010V w/ POWER SWITCHING 010V () 010V (+) SWITCHED HOT GRAY PURPLE V DIMMER: 010V w/ POWER SWITCHING www.usailighting.com DIML6A, 6B 010V DIMMING (NO RELAY) 2016., LLC. All rights reserved. I22646 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D7 / DIML7 and D7E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE () ORANGE/ (+) V www.usailighting.com 2016., LLC. All rights reserved. I22647 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D8 / DIML8 and D8E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D8 / DIML8 and D8E Dimming Driver Wiring D8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = Eldo POWERdrive DMX control dims from 100% to 0.1% D8E = Eldo POWERdrive DMX control dims from 100% to 1% DMX BUS XLR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: type: shielded, 2conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100140 ohms conductive core: 24 AWG is recommended If 3wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. D8 / DIML8 / D8E DMX CONTROLS DMX BUS XLR CABLE OR SHIELDED DATA CABLE SHIELD DMX () DMX (+) 5 PIN XLR JACKS STANDARD 8 BIT DMX 512 CONTROLLER RED BARE V www.usailighting.com 2016., LLC. All rights reserved. I22648 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY SELECTION GUIDE D19 / DIML19 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. Deenergize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D19 / DIML19 : Hatch XTC series or equivalent Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V GROUND ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL0610Z Use fixture wattage per 6613xxx fixture specification Lutron S600P sheet to determine S603P number of fixtures DV600P per dimmer. Max number DV603P of fixtures is limited by DVSC603P dimmer load rating. CT600P CT603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04xxx fixture specification Lutron NTELV300 sheet to determine NTELV600 number of fixtures SELV300P per dimmer. Max number SELV303P of fixtures is limited by DVELV300P dimmer load rating. DVELV303P www.usailighting.com 2016., LLC. All rights reserved. I226419 Revised 03/22/2017