DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Similar documents
DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DTA. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Ordering Key. Dielectric strength

Operating Manual VMD420

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Process Alarm Module RTA 421

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Soft Starter Centrifugal Pump Soft Starter Series

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

CMD420 / CMD421 Series

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

REA 105 Arc Protection Module. Operator s Manual

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Multi-Gas-Controller MGC2

RSGD. Three phase AC motor soft starter. Benefits. Description

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Table of Contents. Protective Relays

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

UDC100 Universal Digital Controller Specifications

02/11/2015

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Bender GmbH & Co. KG. All rights reserved. Reprinting only with permission of the publisher. Subject to change! Photos: Bender archives

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

M15051) INSTRUCTION MANUAL

VAMP 120 & 121. Arc flash detection units. Product picture

Series Temperature Controller Instruction Sheet

Thermal Management Products & Accessories for Enclosures

02/11/2015

Overload relays. General descriptions. Configuration of the front

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

Oxygen (O2) Single-Point Gas Detection System

Monitoring Devices 11/1

Instructions for the fan motor control system with integrated wiring terminals SILVER C

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

BC3250. Blowdown Controller

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Water Detection Controllers

Bulletin 1608N MiniDySC Dynamic Sag Corrector

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Room Temperature Controller

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

C-Bus Four Channel General Input Unit Installation Instructions

Universal fault annunciator for panel mounting

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

VME420 Voltage and frequency monitor

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

M2000 Engine Controller

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

SCHMIDT LED Measured Value Display MD Instructions for Use

LC3000 Level Controller Installation and Maintenance Instructions

4 & 8-POINT ANNUNCIATORS Instruction Manual

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

DOCUMENTATION IPS640

VME421H Voltage and frequency monitor

DOCUMENTATION IPS640

ACS-30-EU-EMDR- 10-MOD

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Panel Mounted Fault Annunciator Series

Preliminary Release. Room Temperature

T M LIM2010. Line Isolation Monitor (LIM) Technical Bulletin NAE /

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Annunciator Unit SACO 16 D1. Product Guide

Operating Manual TR600

Residual Current Devices

Low Temperature Zirconia Oxygen Analyzer

Annunciator unit. Application

TER Active Room Temperature Sensor (Controller),

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Product Tests Report

Remote alarm indicator and test combination MK2430

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Operating Instructions. For. Alarm Control Module. Model SSR 500

/8 DIN Level Indicator

I/A Series 716C 1/16 DIN Temperature Controller

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Room Temperature Controller with LCD

for relative humidity and temperature

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Transcription:

DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges and over / under. 7 Voltage ranges can be selected by means of a front dial. Over and under voltages are adjustable from + or - 2 to 22% of the selected range. Bicolour Alarm LED indication. A green/red LED provides visual indication of the alarms status by means of colours of blinks. Output LED indication. A yellow LED provides visual indication of the output status. Relay contact output. TA relay contact provides electrical (remote) indication of the alarms/output status. High Compactness. The DPA52 is a 3-Phase monitoring relay with 17,5mm width. DPB52 is a monitoring relay suitable 3-phase without neutral mains. Further to protect loads from wrong phase sequence and phase loss, it also provides the undervoltage and overvoltage features with adjustable delay ON. The phase loss is detected also with regenerated voltage presence. DPB52 the device supply is provided by the measured mains. Being switch mode, the power supply, besides immune to disturbances, transients and harmonics problems, is also wide range input. Further protection, against humidity and dust, is provided by the conformal coating of the internal circuitry. The output signal is provided by a 5A changeover electromechanical relay. 2 front LEDs provide visual indication of output state and alarm discrimination. Alarm LED is bicolour, its colour and flashes indicate the operation status. Due to the low profile DIN construction it is possible to install it either in industrial cabinets as well as the electrical distribution NORM panels. Applications DPB52 is suitable for all applications where it is necessary to monitor besides the phase presence and correct phase sequence of threephase load mains, also the correct value: lifts, escalators, HVAC, material handling, pumps and compressors, machines for export markets. 1

DPB52 Main function 3Ph monitoring From 208V to 480V rated input Adjustable Over / Under Voltage and Delay ON Phase sequence and Phase loss Alarm 5A SPDT relay output MiniDIN 17.5 housing Structure Element Component Function A Input/supply terminals L1, L2 and L3 supply and measuring terminals B Output terminals Output Relay contacts terminals: COM, NO and NC LED 1 Output Led LED lit when Output is Energised LED 2 Alarm LED Bicolour green/red LED, blinking or fixed: Steady ON green: OK (no alarms) Green Flashing: UNDER or OVER triggered, Delay ON is elapsing 1 red flash: out of range parameters alarm 2 red flashes: Wrong phase sequence alarm 3 red flashes: Phase loss Alarm 4 red flashes: Under voltage after Delay ON elapsed 5 red flashes: Over voltage after Delay ON elapsed C Dials Settings for Over Voltage, Under Voltage, Delay ON, Rated Line Voltage 2

DPB52 Features L1 L2 L3 16 18 15 General data Material Nylon Protection grade IP20 Housing colour RAL7035 Weight approx.75g ( 2.65oz) Dimensions 81H x 67.2D x 17.5W Terminals wire size AWG30 to AWG13, stranded or solid Terminals tightening torque max. 0.5Nm 3

DPB52 Power supply Power supply Consumption Voltage range: 208V -40% to 480V +30% ( 125V to 624V ) Supplied from L2, L3 measured phases Frequency range: 45Hz to 65Hz sinusoidal waveform < 2 VA Environmental Working temperature -20 C to 60 C (-4 F to 140 F) Storage temperature -30 C to 80 C (-22 F to 176 F) Relative humidity 5%-95% Pollution degree 2 Operating max altitude 2000m a.m.s.l. ( 6562ft ) Salinity No saline environment UV resistance Other Possible UV exposure if installed in an outdoor Electric panel with transparent door Tests with the device outside the box: Vibration response (IEC60255-21-1) Vibration endurance (IEC 60255-21-1) Shock (IEC 60255-21-2) Bump (IEC 60255-21-2) Tests with the device inside the box: Vibration, random (IEC60068-2-64) Shock (IEC 60255-21-2) Bump (IEC 60255-21-2) Vibration/Shock resistance Note: Class 1: Monitoring devices for normal use in power plants, substations and industrial plants and for normal transportation conditions. The packaging type is designed and implemented in such manner that the severity class parameters will not be exceeded during transportation. 4

DPB52 Compatibility and conformity Approvals CE Marking LV directive, EMC directive EN 60947-5-1 culus Marking UL 508, CSA 22.2 Inputs Variable measuring Measuring ranges Voltage PH-PH measurement on L1, L2 and L3 lines Phase sequence Phase loss Out of range measurement Voltage measurement Typology PH-PH voltage measurement on L1, L2 and L3 lines Nominal Line Range From 208Vac -35% to 480Vac +25% (135Vac to 600Vac ) Setting ranges (Un) 208V, 220V, 240V, 380V, 400V, 415V, 480V Overload range <125V (208Vac -40%) and >624 (480V+30%) Over / Under Voltage alarms Input variables Voltage measurement L1L2, L2L3, L1L3 Reaction time 200ms + set Delay ON Undervoltage setting range (U<) from -2% to -22% Overvoltage setting range (U>) from 2% to 22% Resolution 1V + 2% notch Accuracy 1V + 2% Repeatability 0.5% reading +1V +/-0.2% Hysteresis 2% fixed Delay ON Adjustable from 0.1s to 30s Delay OFF 5

DPB52 Phase Loss alarm Input variables L1-L2, L2-L3 and L3-L1 Voltage measurements Alarm Threshold 75% of (1 - (L1,2,3 Max L1,2,3Min) / L1,2,3Avg) Restore threshold >75% of (1 - (L1,2,3 Max L1,2,3Min) / L1,2,3Avg) + Hysteresis Adjustable range Fixed Reaction time 200ms Resolution 1V Accuracy 1% reading +1V Repeatability 0.5% reading +1V Hysteresis 2% fixed Delay ON Delay OFF Input variables Restore threshold Adjustable range Delay ON Delay OFF Phase Sequence alarm Connections L1, L2, L3 200ms Not applicable, always active. Out of range alarm Input variables L1-L2, L2-L3 and L3-L1 Voltage measurements Reaction time 200ms Resolution 1V Accuracy 1% reading +1V Repeatability 0.5% reading +1V Hysteresis 2% Delay ON Delay OFF 6

DPB52 Output Number of outputs 1 Type Logic Contact rating Assignment SPDT electromechanical relay with change-over contacts Output De-Energized on Alarm AC1: 5A @ 250Vac AC15: 2.5A @ 250Vac DC12: 5A @ 24Vdc DC13: 2.5A @ 24Vdc Associated to all alarm types Insulation Terminals Inputs: L1,L2,L3 to Output: 11,12,14 Basic Insulation 2.5KVrms, 4KV impulse 1.2/50us (basic) 7

DPB52 Operating description Suitability DPB52 can be used for power supply and mains quality monitoring of threephase loads with nominal supply voltage from 208VAC to 480VAC. Monitoring function is performed between Line to Line. Device configuration The relay operates when all the phases are present, the phase sequence is correct and the phase-phase voltage levels are within set limits. The relay releases when one or more phase-phase voltages exceeds the upper set level or drops below the lower set level. The DPB52 is configurable by trimmers, in order to set Over / Under Voltage, Delay ON and Rated Line Voltage. User interface dial for OVERVOLTAGE adjustment Typology Linear selection from +2% to +22% Resolution 2% / notch Accuracy Absolute +/-1% (e.g. trimmer position on notch 10% => set value from 9% to 11%) Repeatability Absolute +/-0.2% (e.g. set value 10% => variation from 9.8% to 10.2%) Function Relative voltage threshold setting of OVERVOLTAGE alarm User interface dial for UNDERVOLTAGE adjustment Typology Linear selection from -2% to -22% Resolution 2% / notch Accuracy Absolute +/-1% (e.g. trimmer position on notch 10% => set value from 9% to 11%) Repeatability Absolute +/-0.2% (e.g. set value 10% => variation from 9.8% to 10.2%) Function Relative voltage threshold setting of UNDERVOLTAGE alarm User interface dial for DELAY setting Typology Logarithmic adjustment from 0.1s to 30s Resolution Accuracy Repeatability Function From 100ms/notch at 0.1s to 10s/notch at 30s Absolute form +/-50ms at 0.1s to +/-5s at 30s Absolute form +/-10ms at 0.1s to +/-1 at 30s Alarm ON Delay setting for undervoltage and overvoltage User interface dial for NOMINAL grid voltage Typology 7 ranges selection 208V, 220V, 240V, 380V, 400V, 415V, 480V Function Nominal Mains voltage selection 8

DPB52 Alarms The DPB52 operates in 2 different modes depending upon the alarm type. The following ones cause immediate output relay de-energisation: Phase loss Wrong phase sequence Out of range measurement The following ones will cause output relay de-energisation after the set Delay on alarm has elapsed. Undervoltage U< Overvoltage U> In this case if the alarm cause returns to normal condition, before delay elapsing, the output will not switch. Visual information The DPB52 features 2 front LEDs which provide the relay status information LED1 (Output Led ) is lit when the Output is Energized LED2 (Alarm Led) is bicolour green/red and can be blinking or fixed: Green On fixed: OK (NO Alarms ) Green Flashing: Undervoltage or Overvoltaga alar triggered but delay still elapsing 1 red flash: Out of range parameters alarm ON 2 red flashes: Phase sequence alarm ON 3 red flashes: Phase loss alarm ON 4 red flashes: Under voltage alarm ON 5 red flashes: Over voltage alarm ON Phase loss Phase loss measurement is performed by comparing the 3 phases voltage values ( L1-L2, L2-L3, L1-L3). If the voltage of one phase falls below 75% compared to the other 2 phases, the alarm goes off. DPB52 detects loads regenerated voltage, for instance on motor or transformer loads. 9

DPB52 General operation block diagram Power supply Motor Power supply Power supply Output Breaker 10

DPB52 Connection Diagrams Example 1 Example 2 Example 1 (mains network monitoring) The relay monitors phase loss, correct phase sequence, over and under voltage. Example 2 (load monitoring) The relay monitors phase loss, correct phase sequence, over and under voltage of a load. 11

DPB52 References DPD Further reading Information Where to find it QR Instructions Manual http://www.productselection.net/manuals/uk/dpb52_im.pdf Monitoring relays Brochure http://www.productselection.net/manuals/uk/bro_monitoring_2017.pdf CARLO GAVAZZI compatible components - - - Order code DPB52CM44 12