PURESTREAM CHILL-CUBE TM BY FRIULAIR

Similar documents
ULTIMATE ENERGY SAVING TECHNOLOGY

Ultimate energy saving technology

Ultimate energy saving technology

PART-LOAD LEADER EFFICIENCY. Certified to Canadian Standards

Hyperchill. water chillers

CHILL-CUBE MULTIBANK BY FRIULAIR

Air cooled industrial chillers

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

KELVIN Clim F497. Kelvin air conditioning

LZT High efficiency air to water heat pumps with E.V.I. compressors

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

kw COOLING kw HEATING

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

nemo a hp rcgroupairconditioning R410A

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

HYDRONIC RESIDENTIAL

Galletti Water chillers and heat pumps catalogue

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

pyxis u pyxis ua NEW rcgroupairconditioning

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Industrial cooling solutions

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

PRODUCT GUIDE

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

GENERAL INFORMATIONS

PYXIS U PYXIS U. rcgroupairconditioning

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

LZA High efficiency air to water heat pumps with HP compressor

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

PACKAGED AIR COOLED Product Data Catalog

unico pf unico pf rcgroupairconditioning

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

44,9 202,0 kw. technicalcatalogue

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

WZH Ground source heat pumps

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Aquaflair TRAC-TRAF-TRAH

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Call us today! (800)

kw. technicalcatalogue

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

H4T R410A. refrigerant

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors

Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons

RECORD SUBMITTAL COVER SHEET

GP SERIES Packaged Chillers

Call us today! (800)

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

OACS Outdoor Air-Cooled Central Chillers

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

NEXT DL NEXT DL. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Transcription:

PURESTREAM CHILL-CUBE TM BY FRIULAIR Air-cooled water chiller Cooling capacity from 0.5 to 6 tons R407C Refrigerant QPS Inspection label certified to CSA standards 2 Year parts warranty

The QBE Chill-Cube Series: verview The new Chill-Cube range of chillers are specifically designed to meet the stringent cžžůŝŷő requirements of today s advanced equipment and processes. TŚĞ Chill-Cube provides precise temperature control of chilled water while operating with varying loads in a variety of applications and industries. These chillers are fitted with a precision regulation system to manage outlet water temperature (±1C). The system utilizes Electronic/Mechanical hot gas bypass valves to keep running at low demand and match capacity to actual load. The range includes 11 models with cooling capacities ranging from.5 to 6 Ton. QBE models 002-007 have been designed to be installed indoors, while the QBE 009-025 models have been designed to be installed in or outdoors (QBE 003-007 models can be installed outdoors as an option). All units are equipped with: Rotary or scroll type hermetic compressors Environmentally friendly refrigerant R407C Microprocessor controller (electronic thermostat for QBE 002) Atmospheric inertial water tank Hydronic pump Non-ferrous materials for hydronic circuit l Mechanical Hot Gas Bypass Valves as standard (Exception: QBE 002) Compressors Purestream Chill-Cube chillers utilize rotary and scroll hermetic compressors. These compressors are the industry choice, known for reliability and efficiency through their widespread use in the air conditioning and refrigeration industries. The scroll compressor adds the additional benefits of quiet operation, no vibration and the ability to absorb liquid returns. The compressors are mounted on rubber anti-vibration blocks to reduce noise.the three phase compressors are also protected by an electronic device controlling phase sequences in order to prevent reverse rotation. Rotary compressor Scroll compressor Condenser Fans The four-pole axial fan motors are complete with external sickle shaped fan blade which is activated by condensing pressure which allows for low operation temperature installations located indoors or outdoors. All fans have a protection grill, thermally protected with automatic reset and class F insulation. (QBE 002 model excluded). Chill-Cube Evaporators The QBE 002 thru QBE 007 models is equipped with a copper co-axial evaporator. All other models are equipped with an energy efficient compact stainless steel brazed plate evaporator. The electronic controller s anti-freeze function keeps the evaporator s outlet water temperature controlled in order to prevent freeze ups. For models QBE 009-025 a differential pressure switch protects the evaporator against low water flow. Co-axial evaporator Brazed plates evaporator

Refrigerant circuit The refrigeration circuit is made of high quality materials and assembled by experienced factory professionals which follow rigorous brazing procedures which conform to directive 97/23. The refrigeration circuit includes: Rotary compressors for models QBE 002-012 or scroll compressors for models QBE 014-025. Copper coaxial evaporators for models QBE 002-007 and AISI 316 stainless steel brazed plates for models QBE 009-025. Microchannel condenser. Dehydrat o filter. Sightglass Flow indicator indicating presence of humidity for models QBE 009-025. Thermostatic equalization expansion valve for all models excluding model QBE 002. Manual reset high pressure switch. Automatic reset low pressure switch for models QBE 009-025. High and low pressure gauges for models QBE 009-025. Refrigerant gauge connections. Circulation pumps All models have a high efficiency multistage centrifugal pump with steel impeller. All parts coming into contact with fluid are made of AISI 304 stainless steel, mechanical seal in carbon/ceramic/ EPDM materials as standard. All models can utilize water and ethylene glycol mixtures of up to 30%. The pump motor is 2 pole, self - ventilated class F insulation and IP55 protection level. QBE 002 model is available with pressure level P2. QBE 003-007 models are available with pressure levels P3 and P5. QBE 009-025 models are available with 3 pressure levels P2, P3, P5. Frame and cabinet covering material is made from galvanized steel and painted in a powder coat paint finish making All frame and cabine it suited for outdoor installation and for protection in harsh environments. All fasteners are either stainless steel or electro-galvanized. The Chill-Cube was designed so that all parts, particularly those requiring maintenance and cleaning, are easy to access without interfering with the chiller operation and assuring a safe environment for the technician.

Control panel The control panel complies with the Canadian electrical code and includes a door lock disconnect (only models with three phase power input) which prevents access to the watertight control panel door when it is powered All control panel wires are numbered with identification, allowing for easier trouble shooting and maintenance. Microprocessor controller The electronic micro-processor controler optimizes all chiller functions, excluding model QBE 002. The controller regulates the water outlet temperature. Switches pump on and off. Manages compressor s on and off cycles based on water temperature required while guaranteeing minimum operating times to protect the compressor. Measurement and display of water temperature. Manages the following alarm messages: o High and low refrigerant pressure switch. o Water differential pressure switch (only QBE 009-014). o Thermal protection for electrical motors (only QBE 009-014). o Temperature probe failure. o Anti-freeze. User interface is easy and intuitive. The easy-to-follow set up menu allows for easy access to set main operating parameters. The integrated display with its clear icons provides a complete real time display of chiller operations and any alarm status. QBE 002 Electronic thermostat QBE 003-025 Microprocessor controller Safety and Protection devices Temperature probes that control and display evaporator inlet and outlet water temperature, to prevent the possibility of freezing (model QBE 002 excluded). High pressure switch: Signals the chiller to stop operation if the unit reaches irregular pressures on the refrigerant circuit's high pressure side. nce the problem has been corrected, the unit can be manually reset. Low pressure switch on models QBE 002-007: Designed to stop the chiller if refrigerant pressure is too low. Differential water pressure switch: Stops the chiller if water capacity is too low. (only models equipped with brazed plate evaporator) Phase sequence control: (just models with three phase power input) stops the machine starting if the electric power phase sequence is wrong, to avoid compressors from rotating in the opposite direction to the one set.

Hydraulic circuit Includes: Thermally insulated storage tank, in ABS for models QBE 002-007 and plastic for models QBE 009-025 Thermally insulated electric pump Water by-pass which prevents problems linked to shut-off valves being closed by mistake Water differential pressure switch (models QBE 009-025) Water gauge Water level switch Drain valve Water filler The storage tank is on the unit outlet to limit temperature variations due to the compressor being switched on and off. All QBE models are fitted with open hydraulic tank not pressurized. All models have as an option pressurized water circuit with the exception of model QBE 002. All QBE models have as standard the hydraulic circuit with non-ferrous materials. ptions for hydraulic circuit The Chill-Cube series is designed for several options, making it easily adaptable to various operating conditions: Pressurized tank in carbon steel Pressurized tank in stainless steel Pump with high head pressure Buffer tank at the machine input nly evaporator nly evaporator and pump nly evaporator and tank Additional hydraulic connection at the tank Flow stabilizing valve Plate heat exchanger Plate heat exchanger built entirely in stainless steel Not all combinations of the options mentioned here are possible, the availability of a combination of accessories must be verified by contacting us. Controls and testing Each chiller is tested at full load. The following quality control testing is performed: Accurate component assembly Double pressing of refrigerating circuit connections and search for leaks using helium leak-detector Testing hydraulic circuit seals Electrical tests to ensure compliance with electrical standards Test to ensure protection and safety components function properly Test the electronic controller to ensure proper functioning

Hydraulic circuit option table QBE 003-007 QBE 009-025 STANDARD STANDARD Hot gas bypass valve The hot gas bypass valve ensures precision control of outlet water temperature (+0.5 C). The valve by-passes part of - the refrigerant at a high temperature and a pressure to reduce the thermal load on the evaporator. The valve modulation is achieved due to the temperature probe on the evaporator outlet water by the electronic controller. Continuous regulation of cooling capacity also avoids stopping the compressor, ensuring continuity of service. Chillers equipped with hot gas bypass valve are ideal for use with tight tolerances of water temperature ideal for laser cutting machines, welding, profiling, optics, labratory and many other applications. 5

Handling All chillers are supplied packed on pallets so they can be handled using a pallet truck and also making it safe for transporting on transport trucks and sea freight containers. All models are equipped with lifting hooks. QBE 002-007 models are equipped with adjustable supports, and QBE 009-025 models include lifting holes on the base. n request, all models are available with feet and wheels making it easy to move the machine when it has been unpacked. Lifting hooks Lifting holes Wheels Applications Plastics (injection, blow moulding, extrusion, film extrusion, thermoforming) Printing and graphics (manufacture, printing, cardboard, labels, plastic film) Medical imaging Food (beverage, confectionery, chocolate, processing, storage) Lasers (welding, profiling, cutting, optics, medical, marking, aesthetics) Mechanical (welding, cutting, profiling, polishing, rolling, grinding) ther (wood, ceramics, gold, biogas pharmaceutical, compressed air, textile) Hydraulic circuit cooling machine tool Paint and finishing EDM

Technical data QBE (US Units) Model QBE 002-E (5) 003-E 004-E Cooling capacity (1) [Tons] 0 84 0 89 1 17 Compressors power input (1) [kw] 0 74 0 64 0 93 Total power input (1) (2) [kw] 1 57 1 47 1 76 Total absorbed current (1) (2) [A] 8 43 8 01 8 58 EER (pump excluded) (1) --- 10.4 12.2 12.0 Water flow (1) [gal/min] 2 23 2 38 3 11 Available pressure (1) [psig] 33 1 50 8 47 8 Maximum power input (total) (2) (3) [kw] 2 0 2 0 2 4 Maximum absorbed current (total) (2) (3) [A] 10 6 10 6 10 9 Starting current (2) (3) [A] 24 1 24 1 35 1 Fan power [kw] 0 23 0 23 0 23 Fan current [A] 1 00 1 00 1 00 Number of fans [#] 1 1 1 P3 Pump power input [kw] 0 60 0 60 0 60 P3 Pump absorbed current [A] 4 10 4 10 4 10 Power supply [V/Ph/Hz] 230/1/60 IP protection degree --- IP40 Refrigerant --- R407C Compressor type --- Rotary Evaporator type --- Coaxial Condenser type --- Microchannel N of compressors [#] 1 1 1 N of refrigerant circuits [#] 1 1 1 Air flow [cfm] 1.295 1.295 1.295 Sound pressure level (4) [dba] 46 46 46 Water connections diameter [inch] 1/2" 1/2" 1/2" Width [inch] 28 3 28 3 28 3 Depth [inch] 26 7 26 7 26 7 Height [inch] 26 3 26 3 26 3 Weight [lb] 181 187 194 Tank capacity - ption [gal] 6 6 6 6 6 6 P5 Pump power input - ption [kw] 0 60 0 60 P5 Pump absorbed current - ption [A] 4 10 4 10 (1) Data referred to following conditions: water temperature in/out: 68/59 F - ambient air temperature: 77 F (2) Data referred to unit with pump P3 (3) Data related to most heavy condition allowed by safety devices fitted on the unit (4) Referred at 10 m and at an height of 1 5 m in free field (5) Data referred to unit with pump P2

Model QBE 005-E 006-E 007-E Cooling capacity (1) [Tons] 1 39 1 67 2 05 Compressors power input (1) [kw] 1 12 1 55 2 52 Total power input (1) (2) [kw] 1 95 2 38 3 35 Total absorbed current (1) (2) [A] 10 39 12 52 16 74 EER (pump excluded) (1) --- 12.35 11.26 9.0 Water flow (1) [gal/min] 3 69 4 45 5 46 Available pressure (1) [psig] 50 2 48 0 44 6 Maximum power input (total) (2) (3) [kw] 2 7 3 2 4 1 Maximum absorbed current (total) (2) (3) [A] 13 9 16 3 20 0 Starting current (2) (3) [A] 40 1 55 1 77 1 Fan power [kw] 0 23 0 23 0 23 Fan current [A] 1 00 1 00 1 00 Number of fans [#] 1 1 1 P3 Pump power input [kw] 0 60 0 60 0 60 P3 Pump absorbed current [A] 4 10 4 10 4 10 Power supply [V/Ph/Hz] 230/1/60 IP protection degree --- IP40 Refrigerant --- R407C Compressor type --- Rotary Evaporator type --- Coaxial Condenser type --- Microchannel N of compressors [#] 1 1 1 N of refrigerant circuits [#] 1 1 1 Air flow [cfm] 1.471 1.471 1.471 Sound pressure level (4) [dba] 46 46 46 Water connections diameter [inch] 1/2" 1/2" 1/2" Width [inch] 28 3 28 3 28 3 Depth [inch] 26 7 26 7 26 7 Height [inch] 26 3 26 3 26 3 Weight [lb] 203 209 220 Tank capacity - ption [gal] 6 6 6 6 6 6 P5 Pump power input - ption [kw] 0 60 0 60 0 60 P5 Pump absorbed current - ption [A] 4 10 4 10 4 10 (1) Data referred to following conditions: water temperature in/out: 68/59 F - ambient air temperature: 77 F (2) Data referred to unit with pump P3 (3) Data related to most heavy condition allowed by safety devices fitted on the unit (4) Referred at 10 m and at an height of 1 5 m in free field

Model QBE 009-R 012-R 014-R 020-R 025-R Cooling capacity (1) [Tons] 2 64 3 56 4 55 5 44 6 97 Compressors power input (1) [kw] 1 87 2 68 2 62 3 12 4 98 Total power input (1) (2) [kw] 2 74 3 55 4 56 5 06 6 92 Total absorbed current (1) (2) [A] 9 28 10 33 7 91 8 48 11 41 EER (pump excluded) (1) --- 13.9 13.8 14.3 14.7 13.5 Water flow (1) [gal/min] 7 03 9 47 12 11 14 49 18 56 Available pressure (1) [psig] 37 6 32 8 39 1 36 0 26 6 Maximum power input (total) (2) (3) [kw] 3 9 5 2 7 2 7 8 9 9 Maximum absorbed current (total) (2) (3) [A] 10 9 12 8 11 5 12 4 15 7 Starting current (2) (3) [A] 38 3 45 3 46 8 55 8 74 8 Fan power [kw] 0 41 0 41 1 20 1 20 1 20 Fan current [A] 0 74 0 74 2 00 2 00 2 00 Number of fans [#] 1 1 1 1 1 P3 Pump power input [kw] 0 46 0 46 0 74 0 74 0 74 P3 Pump absorbed current [A] 5 60 5 60 1 80 1 80 1 80 Power supply [V/Ph/Hz] 460/3/60 IP protection degree --- IP44 Refrigerant --- R407C Compressor type --- Rotary Scroll Evaporator type --- Brazed plates Condenser type --- Microchannel N of compressors [#] 1 1 1 1 1 N of refrigerant circuits [#] 1 1 1 1 1 Air flow [cfm] 2.825 2.943 3.237 3.237 3.237 Sound pressure level (4) [dba] 48 48 49 49 49 Water connections diameter [inch] 1" 1" 1" 1" 1" Width [inch] 39 5 39 5 39 5 39 5 39 5 Depth [inch] 29 6 29 6 29 6 29 6 29 6 Height [inch] 49 5 49 5 49 5 49 5 49 5 Weight [lb] 529 540 562 562 562 Tank capacity - ption [gal] 23 8 23 8 23 8 23 8 23 8 P2 Pump power input - ption [kw] 0 43 0 43 0 43 0 43 0 43 P2 Pump absorbed current - ption [A] 0 80 0 80 0 80 0 80 0 80 P5 Pump power input - ption [kw] 0 74 0 74 0 74 0 74 0 74 P5 Pump absorbed current - ption [A] 1 80 1 80 1 80 1 80 1 80 (1) Data referred to following conditions: water temperature in/out: 68/59 F - ambient air temperature: 77 F (2) Data referred to unit with pump P3 (3) Data related to most heavy condition allowed by safety devices fitted on the unit (4) Referred at 10 m and at an height of 1 5 m in free field

Model QBE 005-R 006-R 007-R Cooling capacity (1) [Tons] 1 78 2 01 2 31 Compressors power input (1) [kw] 1 58 2 17 2 86 Total power input (1) (2) [kw] 2 27 2 86 3 55 Total absorbed current (1) (2) [A] 9 26 9 94 11 05 EER (pump excluded) (1) --- 11 8 10.0 9.0 Water flow (1) [gal/min] 4 75 5 34 6 15 Available pressure (1) [psig] 47 0 45 0 42 1 Maximum power input (total) (2) (3) [kw] 2 9 3 7 4 4 Maximum absorbed current (total) (2) (3) [A] 10 0 11 0 12 2 Starting current (2) (3) [A] 26 6 22 6 29 6 Fan power [kw] 0 23 0 23 0 23 Fan current [A] 1 00 1 00 1 00 Number of fans [#] 1 1 1 P3 Pump power input [kw] 0 46 0 46 0 46 P3 Pump absorbed current [A] 5 60 5 60 5 60 Power supply [V/Ph/Hz] 460/3/60 IP protection degree --- IP44 Refrigerant --- R407C Compressor type --- Reciprocating Evaporator type --- Coaxial Condenser type --- Microchannel N of compressors [#] 1 1 1 N of refrigerant circuits [#] 1 1 1 Air flow [cfm] 1.471 1.471 1.471 Sound pressure level (4) [dba] 46 46 46 Water connections diameter [inch] 1/2" 1/2" 1/2" Width [inch] 28 3 28 3 28 3 Depth [inch] 26 7 26 7 26 7 Altezza - Height [inch] 26 3 26 3 26 3 Weight [lb] 203 209 220 Tank capacity - ption [gal] 6 6 6 6 6 6 P5 Pump power input - ption [kw] 0 74 0 74 0 74 P5 Pump absorbed current - ption [A] 1 80 1 80 1 80 (1) Data referred to following conditions: water temperature in/out: 68/59 F - ambient air temperature: 77 F (2) Data referred to unit with pump P3 (3) Data related to most heavy condition allowed by safety devices fitted on the unit (4) Referred at 10 m and at a height of 1 5 m in free field

Standard equipment and optional components QBE model 002 003-007 009-025 Atmospheric hydraulic circuit with non-ferrous materials Hydraulic pressurized circuit with non-ferrous materials (1) Water bypass Pump P2 Head pressure pump P3 Head pressure pump P5 Head pressure pump No pump Cold atmospheric tank (at the exit of the machine) Warm atmospheric tank (at the inlet of the machine) Cold atmospheric tank (at the exit of the machine) No pump Cold pressurized tank (at the exit of the machine) (1) Warm pressurized tank (at the inlet of the machine) (1) Cold pressurized tank (at the exit of the machine) No pump (1) Warm pressurized tank (at the entrance of the machine) No pump (1) Cold pressurized tank with disconnector and double pump Storage tank with additional connections (3) No tank (1) Electronic hot gas by-pass valve Mechanical hot gas by-pass valve Water differential pressure switch (4) High pressure switch Low pressure switch Refrigerant gauges Water gauge (2) Water level switch Thermostatic valve Thermostat unit control Parametric microprocessor controller Phase sequence control relay switch Compressor crank case heater Condensing control (fan on-off) Fan continuous speed control (Low air temperature kit) utdoor installation setting Stainless steel air filters Wheels Adjustable supports Legend: not available; standard; optional; * contact our company (1) ption available only for units with plate heat exchanger (2) Water gauge included in all units with pump (3) Additional connection included in all units with pressurized tank (4) Water differential pressure switch included in all the units with plate heat exchanger Made In Italy