User s Guide OS210-C4. IR Temperature Sensors. Shop online at omega.com. For latest product manuals: omegamanual.

Similar documents
OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. Shop online at. Made in China. Two-wire Display and Control Unit

User s Guide. OSXL685 and OSXL689. High Performance Infrared Thermometer. Shop online at

User s Guide. Setpoint Option Card. Shop online at. omega.com For latest product manuals: omegamanual.

LVCN-302 Set-Up Manual for Sump Model

User s Guide OS-MINI22 SERIES. Shop online at omega.com SM. For latest product manuals: omegamanual.info

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

User s Guide. LVU-800, & LV U Ultrasonic Level System

User s Guide. FLSW Series ROTAMETER WITH ALARM. Shop online at omega.com. For latest product manuals:

OMEGA (MODEL:610LF) OS642F-LS Infrared Thermometer With Laser Marker

User s Guide OS137 SERIES. Miniature Non-Contact Infrared Temperature Sensor/Transmitter. Shop online at omega.com

User s Guide. DPF-520 Series XXXXXX. Shop online at. omega.com For latest product manuals: omegamanual.info

User s Guide TOTE SERIES. Wrap-Around Tote Tank Headers. TOTE SERIES Wrap-Around Tote Tank Heaters. Shop online at omega.com

OMEGA. OS643E-LS/OS643E Infrared Thermometer With Laser Sighting

LDP-124 AND LDP-144 SERIES FOR TEMPERATURE

RS Pro Infrared Temperature Sensor

User s Guide FST1000 SERIES. Air Flow Switch with Two SPST Relay Contact Closures. Shop online at omega.com

User s Guide. Shop online at. omega.com CN Chromalox Rev Set Point. Load. Alarm.

User s Guide. Shop online at omega.com. For latest product manuals: WITH REMOTE SENSOR PROBE FMA100XR

OMB-DAQ-TC-RACK-EXP32

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

User s Guide OS100E SERIES. Mini-Infrared Transmitters. Shop online at omega.com. For latest product manuals: omegamanual.

DPG300 SERIES M-5258/0213

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

User s Guide RH650. Shop online at omega.com SM. 9-In-1 Thermo-Hygrometer/ Moisture Meter

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Digital Pressure Gauges with Alarms and 4-20 ma Output

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

User s Guide OS100E SERIES. Mini-Infrared Transmitters. Shop online at omega.com SM

Environmental Monitoring SmartSlot Card

Infrared Temperature Sensor

PHH-60/PHH ph/conductivity Meter. Newport Electronics, Inc. Operator s Manual PHH-60 ON OFF. ph/conductivity METER

Duct Humidity/Temp Sensor

User s Guide DP606A/DP612A. Shop online at omega.com. Universal 6/12 Channel ¼ DIN Panel Meter

Duct Temperature Sensors

High Temperature InfraRed Thermometer with Laser Pointer

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Duct Mount. Installation Instructions

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Outside Air Humidity & Temperature Sensor

Series: MBC1-TC Mini Benchtop Temperature Controller

SS-100. Pyrometer. Temperature Range: 800~2400

Environmental Monitoring Card

User s Guide OSXL-101. Compact Thermal Image Sensor Application Software. Shop online at. omega.com

Hydrazine Analyzer Series 2171 Specifications

89BSD Digital Output

MT4 MAX/MT4 MAX + Infrared Thermometer

Document No

MDS8PT. Universal Temperature & Process Benchtop Meter with Alarms

Infrared Thermometer

Room Humidity/Temp Sensor

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Pump-Up Controller MODEL 4062

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

RS485 MODBUS Module 8AI

Mark 25 Ultrapure Water Conductivity Analyzer

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Warranty Registration

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Isolated Thermocouple Module

NT DUAL CHANNEL DISPLAY. User Guide

Precision Infrared Thermometer. Users Manual

Pump-Down Controller MODEL 4052

Owner s Manual. PIR-1 IR Learner

Infrared Thermometer. Getting Started

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Users Manual. Visit us at

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

OPERATION & INSTALLATION MANUAL

Inline Heater for Solvent or Gas. Installation and Operation Manual

Installation & Maintenance Instructions

62 MAX/62 MAX + Infrared Thermometer

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

READ AND SAVE THESE INSTRUCTIONS

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

DMFPM-2R MULTIFUNCTIONAL

VX SERIES Wireless Thermostat with Occupancy Sensor

SAFETY INFORMATION AND WARNINGS

User s Guide. PHE-2724/2726 SERIES ORE 2725 SERIES ph/orp Electrodes

Series Temperature Controller Instruction Sheet

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

62 MAX/62 MAX + Infrared Thermometer

Snifter ATEX22 VERSION. User Manual. Distributor

Microprocessor-Based Temperature/Relative Humidity Recorder

FIRERAY 5000 range USER GUIDE

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

OWNERS MANUAL MODEL 451 (-101 & -201)

Installation & Operation Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

430128A. B-Series Flow Meter SIL Safety Manual

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Transcription:

User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info MADE IN UNITED KINGDOM OS210-C4 IR Temperature Sensors

OMEGAnet Online Service omega.com Internet e-mail info@omega.com Servicing North America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN Mexico: En Español: (001) 203-359-7803 FAX: (001) 203-359-7807 e-mail: espanol@omega.com info@omega.com.mx Servicing Europe: Benelux: Managed by the United Kingdom Office Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl Czech Republic: Germany/Austria: United Kingdom: ISO 9002 Certified Frystatska 184, 733 01 Karvina, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de One Omega Drive, River Bend Technology Centre Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk It is the policy of OMEGA Engineering, Inc.to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.

OS210-C4 series non-contact infrared sensors measure temperatures from -20 C to 500 C and provide an RS485 Modbus RTU interface. OS210-C4 Specifications Temperature Range vs Field-of-View table Field of View Model Number Field of View Model Number 2:1 OS211-C4 30:1 OS301-C4 15:1 OS151-C4 ø5mm @ 100mm OS801-C4 Interface RS485 Modbus RTU Accuracy ±1% of reading or ±1ºC whichever is greater Repeatability ± 0.5% of reading or ± 0.5ºC whichever is greater Emissivity 0.2 to 1.0 Response Time, t 90 240 ms (90% response) Spectral Range 8 to 14 μm Supply Voltage 12 V DC nominal (6-13 V DC) Supply Current 50 ma max. Baud Rate 9600 baud * Format 8 data bits, no parity, 1 stop bit * Mechanical Construction Stainless Steel Dimensions 18 mm diameter x 103 mm long Thread Mounting M16 x 1 mm pitch Cable Length 1 m Weight with Cable 95 g Environmental Environmental Rating IP65 Ambient Temperature 0ºC to 70ºC Relative Humidity 95% max. non-condensing * Other configurations available upon request The DP240 is a 320x240 pixel touch-screen terminal with a 3.5 colour TFT display. It allows the user to display data from up to eight OS210-C4 sensors and configure each sensor individually. The configuration parameters include emissivity setting, signal averaging, peak or valley hold processing and reflected energy compensation. There are two versions available. Each one provides all of the features above, however, the enhanced DP240-AR also provides analogue transmission for up to four sensors, plus two adjustable alarm outputs per sensor for all eight sensors. DP240 TOUCHSCREEN TERMINAL Specifications Display Format LCD type TFT 320 x 240, 3.5 touch screen, Resistive Supply Voltage 12 to 24 V DC Power Consumption 8 W Serial port EXP1 RS485 Modbus RTU interface for OS210-C4 Series sensors Serial port COM2 RS485 / RS232 interface for second display (read only) Outputs (DP240-AR only) 4 analogue outputs, 0 to 10 V DC, 16 programmable alarm outputs,12/24 V DC, 700 ma, (3 A max. per block of 8 outputs). Mechanical Construction Polycarbonate with gasket, transparent lid (PC) and quick release screws Mounting Surface Dimensions 140mm wide x 100mm tall x 44mm deep (DP240) 140mm wide x 100mm tall x 65mm deep (DP240-AR) ENVIRONMENTAL Environmental Rating IP54 (front), IP30 (housing) Ambient Temperature Range 0 C to 45 C Relative Humidity 35% to 95%, non-condensing 3

M16 x 1mm 1000 12 103 18 Accessories A range of accessories to suit different applications and industrial environments is available. These may be ordered at any time and added on-site. The accessories consist of the following parts. Fixed mounting bracket Adjustable mounting bracket Air purge collar Laser sighting tool OPTIONS The following options are available. Options are factory installed and must be ordered with the sensor. Air/water cooled housing Certificate of calibration Longer cable OPTICAL CHART The optical chart below indicates the nominal target spot diameter at any given distance from the sensing head and assumes 90% energy. Distance: Sensor to object (inches) Distance: Sensor to object (inches) Distance: Sensor to object (inches) Distance: Sensor to object (inches) (inches) 0 4 8 4.4 2.4 0.5 (inches) 0 19.7 39.4 3.1 1.8 0.5 (inches) 0 19.7 39.4 1.8 1.1 0.5 (inches) 0 0.5 3.9 0.20 7.9 0.49 (mm) D:S 2:1 D:S 15:1 11.9 11.9 45.2 61.9 78.6 111.9 0 100 200 0 500 1000 (mm) Distance: Sensor to object (mm) Distance: Sensor to object (mm) (mm) D:S 30:1 11.9 28.6 45.2 0 500 1000 Distance: Sensor to object (mm) (mm) 11.9 5.0 12.5 0 100 200 Distance: Sensor to object (mm) OS211-C4 OS151-C4 OS301-C4 OS801-C4 Installation The installation process consists of the following stages: Preparation Mechanical installation Electrical installation Please read the following sections thoroughly before proceeding with the installation. preparation Ensure that the sensor is positioned so that it is focused on the target only. Sensor Target greater than spot size BEST Target equal to spot size GOOD Target smaller than spot size INCORRECT Background 4

Distance and Spot Size The size of the area (spot size) to be measured determines the distance between the sensor and the target. The spot size must not be larger than the target. The sensor should be mounted so that the measured spot size is smaller than the target. Ambient Temperature The sensor is designed to operate in ambient temperatures from 0 C to 70 C. For ambient temperatures above 70 C, an air/water-cooled housing will be required. Avoid thermal shock. Allow 20 minutes for the unit to adjust to large changes in ambient temperature. Atmospheric Quality Smoke, fumes or dust can contaminate the lens and cause errors in temperature measurement. In these types of environment the air purge collar should be used to help keep the lens clean. Electrical Interference To minimise electromagnetic interference or noise, the sensor should be mounted away from motors, generators and such like. Wiring Check the distance between the sensor and the Modbus Master. If necessary, the OS210-C4 sensor can be ordered with a longer cable attached. Power Supply Be sure to use a 12Vdc, (50mA max.) power supply. mechanical installation All sensors come with a 1m cable and a mounting nut. The sensor can be mounted on brackets or cut outs of your own design, or you can use the fixed and adjustable mounting bracket accessories which are shown below. Note: The sensor must be grounded at only one point, either the cable shield or the sensor housing. Fixed Bracket Adjustable Bracket Ø16.0 15.0 45.0 12.0 40.0 9.0 60 Rotation 50.0 25.0 50.0 25.0 48.0 2 x Mounting Holes M4 Clearance 2 x Mounting Holes M4 Clearance 24.0 9.0 24.0 9.0 60 Rotation 60 Rotation 5

air/water cooled housing The air/water cooled housing shown below allows the sensor to withstand high ambient temperatures. It is equipped with two 1/8 BSP fittings. Water temperature should be 10 C to 27 C for efficient cooling. Chilled water below 10 C is not recommended. To avoid condensation, the air purge collar should be used with the water-cooled housing. Water flow rate should not be more than 0.5 to 1.5 litres/min. 1/8 BSP water/air connections M16 x 1mm 19 63 103 21 40.0 Air Purge Collar The air purge collar below is used to keep dust, fumes, moisture, and other contaminants away from the lens. It must be screwed in fully. Air flows into the 1/8 BSP fitting and out of the front aperture. Air flow should be no more than 5 to 15 litres/min. Clean or instrument air is recommended. 1/8 BSP Air connection 25 OS210-APSW (for OS211-C4) 50 OS210-APSN (for OS151-C4, OS301-C4, OS801-C4) 20 29 40 6

DP240-AR DP240 Panel cut-out 132 x 89 mm -0/+1 mm 2-6 mm Electrical installation OS210-C4 sensors with Modbus Master Power Supply 12 VDC + - OS210-C4 Sensor #1 Modbus Master OS210-C4 Sensor #32 RS+ RS- PWR+ PWR- OS210-C4 sensors with DP240 touchscreen terminal OS210-C4 Sensor #1 Power Supply 12 VDC + - Analogue transmission & alarm outputs (DP240-AR only) OS210-C4 Sensor #8 - + RS485- EXP1 RS485+ RS+ RS- PWR+ - + COM2 RS485- EXP1 RS485+ PWR- DP240 Sensor Configuration & Display Optional DP240 or other Modbus Master (Display only) 7

DP240 Connections Power input on M1 (12 to 24 VDC): MODBUS master interface EXP1 on DB9: Description OS210-C4 DB9 pin no. cable ident. RS485 + RS+ 9 RS485 - RS- 4 RS485 GND PWR- 5 MODBUS slave interface COM2 on DB25 (only applicable when using second DP240-AR as display only repeater) Description DP240 (1) DB9 pin no. RS485 + 9 24 RS485-4 25 RS485 GND 5 14 DP240 (2) DB25 pin no. Alarm outputs Q1-16 on M2 (DP240-AR only): Alarm 1 Alarm 2 Sensor 1 Q1 Q2 Sensor 2 Q3 Q4 Sensor 3 Q5 Q6 Sensor 4 Q7 Q8 Sensor 5 Q9 Q10 Sensor 6 Q11 Q12 Sensor 7 Q13 Q14 Sensor 8 Q15 Q16 Analogue outputs (0-10V) AQ1-4 on M3 (DP240-AR only): AQ1 = Sensor 1, AQ2 = Sensor 2, AQ3 = Sensor 3, AQ4 = Sensor 4 DP240 DISPLAY FUNCTIONS Sensor list screen: Unlock display / Edit contrast Search for sensors Move selected sensor up in list Move selected sensor down in list View selected sensor View all sensors Single sensor and multiple sensor display screen: Lock/Unlock display / View sensor list 8

View/edit sensor emissivity setting View/edit sensor reflected energy View/edit sensor measurement filtering and peak/valley hold settings View/edit sensor alarm settings Acknowledge alarms Set units to ºC Set units to ºF Toggle between ºC and ºF Press to toggle between single sensor and multiple sensor displays Sensor status display: N/C:Sensor is not connected OK: Sensor is operating correctly ERR: A communications error has occurred AL1: Alarm 1 is active AL2: Alarm 2 is active AL*: Alarm 1 and Alarm 2 are active Emissivity settings: Press on emissivity value to manually edit, or select a material from the list. Apply settings to selected sensor only Apply settings to all connected sensors Exit without applying settings Reflected energy compensation: To enable: press on reflected temperature value and enter required temperature. Press on enable. To disable: press on disable. Apply settings to selected sensor only Apply settings to all connected sensors Exit without applying settings Filtering and peak/valley hold processing: Enter average period and hold period by pressing on their respective values. Select the required hold mode from the list. Apply settings to selected sensor only Apply settings to all connected sensors Exit without applying settings Alarms: To set alarms, press on alarm temperatures and enter required values. Select alarm mode from list. Apply settings to selected sensor only Apply settings to all connected sensors Exit without applying settings Reset alarms for selected sensor only Reset alarms for all connected sensors Display lock/unlock: When the display is locked, sensor settings can be viewed but not edited. To unlock the display, enter the passcode by pressing on **** (default 1234), then press the unlock button. To lock the display, press the lock button. To change the passcode, first unlock the display, then press the change passcode button. Unlock display Lock display Change passcode Change passcode screen: To change the passcode: enter the new passcode, confirm the new passcode, press the accept button. Accept new passcode Exit without changing passcode 9

Modbus over serial line Interface Baud rate 9600 Format 8 data bits, No parity, 1 stop bit Reply delay (ms) 20 Supported functions Read register 0x03, 0x04 Write single register 0x06 Write multiple register 0x10 Mask write register 0x16 The list below includes all available addresses: R = Read, W = Write, MW = Mask write Address Length Description R/W/MW (words) 0x00 1 MODBUS slave address (1 to 247) R/W * 0x02 2 Sensor identification register R Bits 0..19 - Serial number Bits 20..23 - Sensor type (8 = OS210-C4 sensor) Bits 24..26 - Sensor field-of-view (0 = 2:1, 1 = 15:1, 2 = 30:1) Bits 27..32 - Reserved 0x06 1 Un-filtered object temperature R 0x08 1 Sensor temperature R 0x0A 1 Maximum temperature over hold period R 0x0C 1 Minimum temperature over hold period R 0x0E 1 Average temperature over hold period R 0x10 1 Filtered object temperature R 0x12 1 Reflected temperature R/W 0x14 1 Sensor status register R/W/MW Bits 0..1 - Reserved Bit 2 - Hold processing on (1)/off (0) Bit 3 - Hold peaks (1)/valleys (0) Bits 4..6 - Reserved Bit 7 - Reflected energy compensation on (1)/off (0) Bits 8..15 - Reserved 0x16 1 Average period (1 LSB = 0.05 seconds) R/W Minimum 0.05 seconds, Maximum 60.00 seconds 0x18 1 Hold period (1 LSB = 0.05 seconds) R/W Minimum 0.05 seconds, Maximum 1200.00 seconds 0x1A 1 Emissivity (1 LSB = 0.0001) Minimum 0.2000, Maximum 1.0000 R/W * Single register writes only. New address will not take effect until next power on. Notes: 1. All temperatures are in tenths of degrees C 2. Writing to bits listed as reserved or unlisted registers could cause malfunction 3. All write and mask operations are saved to non-volatile memory 4. For further information please refer to http://www.modbus.org/specs.php 5. Use address 255 to communicate with any connected sensor. Use address 0 to broadcast to all connected sensors (no response expected) 10

operation Once the sensor is in position and the appropriate power, air, water, and cable connections are secure, the system is ready for continuous operation by completing the following simple steps: 1. Turn on the power supply 2. Turn on the Modbus Master 3. Read / monitor the temperature IMPORTANT Be aware of the following when using the sensor: If the sensor is exposed to significant changes in ambient temperature (hot to cold, or cold to hot), allow 20 minutes for the temperature to stabilise before taking or recording measurements. Do not operate the sensor near large electromagnetic fields (e.g. around arc welders or induction heaters). Electromagnetic interference can cause measurement errors. Wire must be connected only to the appropriate terminals. Maintenance Our customer service representatives are available for application assistance, calibration, repair, and solutions to specific problems. Contact our Service Department before returning any equipment. In many cases, problems can be solved over the telephone. If the sensor is not performing as it should, try to match the symptom below to the problem. If the table does not help, call Omega for further advice. Troubleshooting Symptom Probable Cause Solution No output No power to sensor Check power supply Erroneous temperature Incorrect wire connection Check wire colour codes Erroneous temperature Faulty sensor cable Verify cable continuity Erroneous temperature Field of view obstruction Remove obstruction Lens Cleaning Keep the lens clean at all times. Any foreign matter on the lens would affect measurement accuracy. Blow off loose particles (if not using the air purge accessory) with an air puffer. 11

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 37 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal three (3) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2011 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine/Paddlewheel Systems Totalizers & Batch Controllers ph/conductivity ph Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial ph & Conductivity Equipment DATA ACQUISITION Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Data Logging Systems Recorders, Printers & Plotters HEATERS Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment ph, Conductivity & Dissolved Oxygen Instruments M5070/1211