Induction Billet Heaters with Enthalpy Controlled Zone Heating

Similar documents
Gas-Induction Inline Oven Uwe Günter 1,a

Development of Induction Heating Device for Corner of Bloom in Continuous Casting machine

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Heat pump supplemental heating system for motor vehicles

Music Sculptures of Glass and Gold

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Temperature dependent Components within the Pyroelectric Detector

Non-destructive testing of green sanitary ceramics by microwaves and an active thermographic technique

Technical White Paper

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

OPTIMISATION OF NOZZLE ARRANGEMENTS ON DESCALING HEADERS. Jürgen W. Frick Lechler GmbH D Metzingen / Germany

MECHANICAL SERVICES 101. Ian White

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Designing evaporators and condensers for refrigerant mixtures with high temperature

Novel process for the drying of sugar cubes applying microwave technology

Development of Large Size Hybrid Fan

Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration

Chapter 4 Compressors Overview & System Annual Power Consumption

CATALYTIC EMITTER - An old idea in new clothes

Purdue e-pubs. Purdue University

Technical description. Atec.

PCM-module to improve hot water heat stores with stratification: first tests in a complete solar system

Heated tools. Semiconductor equipment

Low-noise fans are not a product of chance

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Best Freeze Drying Solutions

FURNACE EQUIPMENT. Press Ceramic Oven

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

Modern vacuum and overpressure generation for pneumatic conveying

How Computer Simulation Helps to Design Induction Heating Systems

Technical Information

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

PRODUCT DATA SHEETS HEAT PUMPS

SICK AG WHITEPAPER 3 TECHNOLOGIES FOR PCB DETECTION

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

CHILLED ROOM AIR CURTAIN. IsolAir

EVAPORATION NEEDS ENERGY

Thermo Scientific ULT Freezers: Superior Thermal Performance

Jülich Solar Power Tower System Behavior During Downtime

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Development of Motor Fan Noise Prediction Method in Consideration of Operating Temperature during Engine Idling

ENSC 388: Engineering Thermodynamics and Heat Transfer

FURNACE EQUIPMENT. Press Ceramic Oven

New Bitzer factory: Higher precision with air conditioning

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

XRAY SHARK XBD50/XBD51 X-Ray Inspection System for Glass-in-Glass Detection

Improving Boiler Stability Through Advanced Regulatory Control

How to improve air cooler vacuum steam condensers performance in the field

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Vacuum furnaces with gas cooling/ gas quenching

Drive Power and Torque in Paper Machine Dryers

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Epsilon 1-4 LSCplus Epsilon 2-4 LSCplus

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners

An Assessment of Radiator Performance

Cold Weather Operation Of Cooling Towers

Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

Technical Note. EHPA Quality Label Model Range Definition Version

Couscous Instant pasta. Trend to perfection.

DEFECTOVISION IR. Non-Destructive Testing of Steel Billets and Tubes

Single Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Variable Refrigerant Flow (VRF) Systems

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

As we survey audio systems

Optimal Control of Induction Heating Processes

Experiment Instructions. Basic Heat Pump Demonstrator

HVAC Water chiller selection and optimisation of operation

SUCCESS in 11cm (4.25 ) pots: Quality AND Profitability

termo plus High Efficiency Radiator Novelty in Heating Systems Designed by Engineering Germany

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

Thermal Oil Heating System. Heat Recovery System. Member of the

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

Stock Vessels for Improved Quality and Energy Savings

HOME THEATER ACOUSTICS -Volume 4-

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

Heat Exchanger Earny Type

Guidelines for Optimizing Drying and Blow-Off Operations

R07. Answer any FIVE Questions All Questions carry equal marks *****

Sub-Critical Operation of the CO2 Expander/ Compressor

Connections, displays and operating elements C D E G H. Installing the control unit

subwoofer instructions

(Refer Slide Time: 00:00:40 min)

Ceiling air diffuser INDULTHERM INDULTHERM-e

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Transcription:

International Scientific Colloquium Modelling for Electromagnetic Processing Hannover, October 27-29, 28 Induction Billet Heaters with Enthalpy Controlled Zone Heating A. Walther Abstract This paper describes the advantages of induction billet heaters with enthalpy controlled zone heating where each coil is fed by one separately controlled power supply, in contrast to conventional induction billet heaters where all coils are powered by a single power supply. In order to apply these advantages in practice, a control method is required which enables a target-oriented override of the temperature profile. The temperature distribution in the billets at the outlet of the heater line can then be adapted to different requirements with regard to temperature uniformity, scaling rate and energy consumption. Introduction In the forging industry is advantageous to achieve a homogeneous billet temperature at the outlet of the heater with the shortest possible coil line installation length while at the same time minimizing the scaling rate and energy consumption. These objectives should be obtained not only for the nominal billet diameter and throughput but also for smaller billets and throughputs. Since these requirements are partly in conflict the solution generally involves reaching a compromise. 1. Comparison of the different basic designs In principle there are three basic designs for billet heaters: - linear heater - non-linear heater - enthalpy controlled zone heater. The advantages and disadvantages of these approaches will be explained by an typical installation consisting of four coils each, all 15mm long, designed for 1mm nominal billet diameter and nominal throughput of 5kg/h. 1.1. Linear Heating Linear heating is the oldest and simplest method. It is characterized by coils with an equal number of windings which are connected to a single power supply. Therefore the frequencies and the voltages of the coils are equal so that only due to the ferromagnetic properties of the billets the power of the first coil is higher than that of the others. The energy consumption is comparatively small due to the low surface temperature during the heating process, but the temperature uniformity in radial as well as in axial direction is not completely satisfactory for this installation length, as can be seen in Fig. 1. 235

Temperature in C 135 13 125 12 115 11 15 1 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 15 1 5 64kW - 1Hz - 38kW - 1Hz - 168kW - 336kWh/t 5 1 15 2 25 3 35 4 45 5 55 6 33kW - 1Hz - 33kW - 1Hz - Fig. 1. Typical temperature profile of linear heating at 1% throughput 1.2. Non-Linear Heating The temperature uniformity within the billets at the outlet of the heater can be improved by increasing the temperatures at the outlet of each coil by increasing the power of the first and decreasing the power of the last coils in an appropriate manner as shown in Fig. 2. Temperature in C 135 13 125 12 115 11 15 1 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 15 1 5 96kW - 1Hz - 62V - 32 Wdg. 44kW - 1Hz - 62V - 38 Wdg. 245kW - 1Hz - 62V - 53 Wdg. 145kW - 1Hz - 62V - 7 Wdg. 179kW - 358kWh/t 5 1 15 2 25 3 35 4 45 5 55 6 Fig. 2. Typical temperature profile of non-linear heating at 1% throughput 236

Since all coils are connected to the same power supply this power adaptation can usually be realized only by changing the number of windings in each coil, so that the coils become different to each other. Because of higher surface temperature in comparison to the linear heating more scaling is generated and the energy consumption is also slightly higher as a result. Usually it is not possible to operate this heater system with throughputs lower than 5%, because the billets would be superheated at the outlet of the 3 rd coil, as shown in Fig. 3. Temperature in C 135 13 125 12 115 11 15 1 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 15 1 5 375kW - 1Hz - 45V - 32 Wdg. 195kW - 1Hz - 45V - 38 Wdg. 15kW - 1Hz - 45V - 53 Wdg. Fig. 3. Temperature profile of non-linear heating at 2% throughput 65kW - 1Hz - 45V - 7 Wdg. 74kW - 493kWh/t 5 1 15 2 25 3 35 4 45 5 55 6 1.3. Enthalpy controlled zone heating At the first view the temperature profile of the enthalpy controlled zone heating (Fig..4) looks equal to the non-linear temperature profile. But in this case the different power rates of the coils are not achieved by different coil winding numbers but by powering the coils with separate power supplies, so that the power for each coil can be adapted individually. Ideally the power supplies should be identical for all zones and the required coil voltage should be nearly the same for all coils under nominal operating conditions, when using parallel resonant circuits. To vary the power absorption and temperature pick-up in each coil, different frequencies can be used to obtain the required differences in power absorption in each coil zone. Because the power decreases with increasing frequency the required frequencies usually must increase from the first to the last coil of the heater. This leads to another positive effect, since comparatively low frequencies are desirable at the beginning of the heating process where the temperatures are below Curie-Temperature in order to obtain larger electromagnetic penetration depths and to avoid superheating of the billet surface or excessive temperature differences between core and surface, which can lead to cracks in the billets. In the last zones where the temperatures are higher than Curie-Temperature, higher frequencies are necessary for lower energy absorption and to concentrate the applied power near the surface, in order to avoid a surface temperature drop by directly compensating the radiation losses on the surface of the billet. 237

Temperature in C 135 13 125 12 115 11 15 1 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 15 1 5 955kW - 63Hz - 177kW - 354kWh/t 43kW - 815Hz - 5 1 15 2 25 3 35 4 45 5 55 6 235kW - 137Hz - 15kW - 2Hz - Fig. 4. Typical temperature profile of enthalpy controlled zone heating at 1% throughput By controlling the power supplies in an appropriate way, the nominal temperature profile is always kept independent of billet diameter and throughput. 2. Advantages of enthalpy controlled zone heating Due to the independently powered coil and the separately controlled power supplies the following advantages result. 2.1. Prevention of superheating at low throughputs The reason that the billets can superheat at low throughputs as shown in Fig. 3 for nonlinear heating is demonstrated in Fig. 5. The red bars in the back series show the required induced power ratings for each coil at nominal throughput (1%) which are necessary to obtain the non-linear temperature profile that was shown in Fig. 2. In this graph all bars for the single coils are normalized to the induced power of the first coil at 1% throughput. The sum bars are normalized to the sum of the effective power at 1% throughput. The blue bars show the thermal losses which rise with the billet surface temperature. If these are subtracted from the corresponding induced power ratings the effective power ratings remain which cause the temperature rises in the billets as they pass through the respective coils. If a throughput of only 3% is desired, the sum of the effective power of all coils must be reduced down to 3% of the sum of the effective power for 1% throughput. In order to keep the temperature rise in each coil equal to that of 1% throughput the induced power of each coil has to be reduced individually in order to get an effective power of 3% for each coil. This is possible only by separately fed coils and separately controlled power supplies. In case of a single power supply for all coils, the total induced power of all coils can only be reduced proportionally. Due to that the induced power of the last coil drops under the amount of the thermal losses of the billet in that coil, so that the effective power becomes negative. This 238

means that the cross-section averaged temperature of the billets drops while they pass through this coil. So a superheating of the billets occurs at the outlet of that zone where the effective power of the following zone becomes negative. Rel. Power in % 12 11 1 9 8 7 6 5 4 3 2 1-1 1 2 3 4 48 117 3 18 17 Sum - Induced Power - Thermal Losses - Effective Power Power 1 3% Throughput 1% Throughput Fig. 5. power distribution for non-linear heating Because the common power supply for all coils is the reason of superheating at low throughputs, this problem applies not only for non-linear heating but also for linear heating. But for linear heating this effect is not so obvious because the induced power of the coils are not so different. As a result the effective power of the last coil becomes negative only at a very low throughput. 2.2. Improvement of transition behaviour at throughput changes In case of a short-term failure or break of the forging process the heater throughput is usually reduced as much as possible in order to minimize the number of heated but not needed billets. When the production shall be restarted the throughput must be increased back to its production rate as fast as possible. But depending on the time that elapsed with low throughput, some billets may be superheated after resuming normal operation. Like it was already explained in the last paragraph, the cross-section averaged temperatures rise with decreasing throughput. This means that these temperatures are higher than needed when the throughput is increased back to normal levels. If the coils are fed from the beginning with the power levels that are required for the higher throughput, it leads to a corresponding superheating of these billets which are located in the heater at the moment of throughput change, once they reach the heater outlet. By a switch on delay or power ramp the superheating at throughput changes can be lessen a little but it can t be sufficiently compensated in total for all possible combinations of throughputs and billet dimensions. The amounts of the temperature deviations for the stationary states are shown in Fig. 6 for the three types of heater systems. As can be expected from the explanation in the last paragraph, the deviation of the non-linear heating is the highest. Enthalpy controlled zone heating shows the lowest deviation due to its operating principle of constant cross-section averaged temperatures at the outlet of each coil. Linear heating lies somewhere in-between. 239

1 9 8 Linear heating Non-linear heating Enthalpy controlled zone heating Temperature deviation in K 7 6 5 4 3 2 1-1 5 1 15 2 25 3 35 4 45 5 55 6 Fig. 6. Temperature deviation between 5% and 1% throughput Of course this method of estimating the transition behaviour is coarse because it compares only the stationary temperature distribution for both throughputs, but it shows very clearly the reason for the superheating when a throughput change occurs. 2.3. Override of the temperature profile Enthalpy controlled zone heaters ensure that the cross-section averaged temperatures are independent of billet diameter and throughput at the outlet of each coil zone. With the aid of a suitable control interface this heater system provides the potential to change these temperatures and therefore the temperature profile within technical limitations as shown in Fig. 7. The shape of the temperature profile influences the - axial and radial temperature distribution in the billets - energy consumption - scaling rate - billet sticking. The strongly converging curve provides low axial and radial billet temperature differences at the outlet of the heater. But because of the high cross-section averaged temperatures within a long part of the heater the billets can tend to stick. Furthermore the billets can crack due to the high temperature differences between core and surface caused by the high temperature rise in the first coil. Since the surface temperatures are also high for this profile, the scaling rate is higher and the radiation losses are stronger which makes the energy consumption worse. Since the slightly converging temperature profile provides just the opposite an individual compromise can be found for the different requirements. 24

Cross section averaged temperature in C 135 13 125 12 115 11 15 1 95 9 85 8 75 7 65 6 55 5 45 4 35 3 25 2 15 1 5 5 1 15 2 25 3 35 4 45 5 55 6 Typical Strongly converging Slightly converging Fig. 7. Range of possible temperature profile override of an enthalpy controlled zone heater Conclusions In contrast to conventional billet heaters, enthalpy controlled zone heaters keep the workpiece cross sectional average temperature equal and independent of the actual throughput and billet dimensions. Due to that evenness this technique avoids superheating at low throughputs and reduces the number of rejected billets after a short-term failure or break of the forging process. With the aid of a suitable control program the temperature profile can be modified in order to find the best compromise between low billet sticking and scaling rate, uniform temperature distribution within the billets and low energy consumption. Authors Dr.-Ing. Walther, Axel-Michael ABP Induction Systems GmbH Kanalstraße 25 D-44147 Dortmund, Germany E-mail: axel.walther@abpinduction.com 241