Essentials Series 4.0

Similar documents
Essentials Series 4.0

Project Name. Date. Cat. Number. Type

Project Name. Date. Cat. Number. Type

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) (111mm) 3 (76mm)

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

FPLHB - Fidelux Premier Linear Highbay

Alliance 4 - ALI4 LED 4 Linear High Bay

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

DIMMING 0-10V Continuous

LHBXD LED Linear High Bay

DHL-LP-LED Low Profile LED Linear High/Low Bay

Lighting Solutions from a Leader in Light Source Technology

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

Lighting Solutions. from a Leader in Light Source Technology

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

Vaya Linear LP, White & Mono

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Catalog Number. Notes. Type

3.75 Gyro Shift Multiples Single Head

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Parking Garage. Lighting & Control Solutions SLGUS.COM

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

LED Linear Design Highlights

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

New Linear Series DISCONTINUED

Catalog Number. Notes

DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

LED RETROFIT CONVERSION KITS

WARRANTY LED ECO PANEL.

LED HIGH BAY LINEAR ECO SERIES

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

VESICA LINEAR SUSPENDED VES L

Highbay Linear LED Series Flat Profile Design

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

Catalog Number. Notes. Type. IBL Series Lumens Distribution Lens Voltage Color temperature

BAS SFP22 Edge-lit LED Panel

E10 & L9 Low Wattage Light Cone Data

CoreLine Waterproof the clear choice for LED

Evolve LED Garage Light

Venture Lighting s Line of LED Solutions. Professional Grade LED from The Leader in HID

Max 4 Flush Lens RECESSED

PRODUCT DATA SHEET LIGHTING PRODUCTS

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Grüv Flare Regressed. Recessed Linear LED

Claude Indirect Wall WALL

LED ECO PANEL.

Metalux 4WSL / 8WSL LED

Product Specifications

LUXCOMFO TM LED Flood Light Datasheet

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Lumination LED Luminaires

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Truss Surface SURFACE

BayMAX HL Series LED Linear High Bays Presented by: Nick Latwis. November 30, 2016

JEDI COMPACT IP67 INTEGRAL

SURFACE Spec Guide. up to 105 lm/w performance

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

LED FLAT PANEL EDGE LIT MLFP SERIES G2

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

Affordable and reliable energy saving LED Lighting Luminaires

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

HBL. The LED High Bay Series

RECESSED Spec Guide. up to 111 lm/w performance

Metalux 4WSL / 8WSL LED

SPECIALTY LIGHTING NOTES: A Canadian Manufacturer

LED RETROFIT CONVERSION KITS

INDEX. New HBX HBL-G2 HBL-CG PV PV-XT SCL-191 HSLL HLL-AMBER GST SLED-830-XT WPL-F WPL-G WPL-H SDL-321 SDL-370. Smart Illumination System.

RECESSED - WITH StepLens OPTION

TERRALUX RETROFIT LED LIGHTING

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

ArcLine Recessed LED luminaire

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

TROFFER RETROFIT KIT (TRK)

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

FEATURES & SPECIFICATIONS INTENDED USE

S R 8 Circular LED Engine Product Specification

CoreLine Wall-mounted the clear choice for LED

Transcription:

Essentials Series 4.0 LED High Bay Essentials Series 4.0 provides the highest quality, reliability and performance with extraordinary lumen maintenance and efficacy, delivering superior ROI for your application. Project Name Date Cat. Number Type Designed with best-in-class thermal management to perform at ambient temperatures up to 55 C. Applications: Industrial and Commercial Facilities, Warehouses, Manufacturing, Parking Garages, Distribution Centers, Hangars and Indoor Sports. Features & Specifications Environment: Dry/Damp, for interior applications (IP40). DUST option available (IP50). 15 - MULTIPLE PATENTS PENDING - up to 10 YEAR WARRANTY Ambient Range Operation: -4C to 55 C. 1 Heat Sinks: Extruded aluminum heat sinks provide optimal thermal management, decreasing LED junction temperature and ensuring long life and high efficacy. Power Supply Access: Wire way cover is hinged, opening over 12 for hands free easy access and quick wiring. Center hole accepting 20mm stem and also 20mm KO near top end of wire way. Mounting: Fixture is cable ready and has a center opening to accept a 20mm (27mm hole) rod mount, cable, hook or surface mount options (with optional MBR). Lenses: UV stable polycarbonate clear and aisle or acrylic (PMMA) frosted available. LED: Wide angle distribution, extremely long life, non-replaceable light source. CCT: 3000K, 4000K an 5000K standard, other CCT available (extended lead time). Wire Guards: Optional factory-installed wire guards for the fixture and OCC sensor are available. Warranty: 5-year standard. Up to 10-year optional warranty. Rotatable LED Modules: Field adjustable rotating modules. Easily adjusted outer modules with stops at, 9 and. Factory set at. Allows for customizing light pattern to suit individual situations. 12 Power & Control Power Input: 220-240V (50/60Hz), Typical, depending on model. Dimming: 0-10V dimming standard. Capable of dimming down to 10%. DALI dimming available. Emergency Battery Backup: Minimum 2000Lm output for 90 minutes. 12K-4MS (and 2M) which will have an 1, 3, 4, 8, 15 output of 1400 Lm for 90 minutes. Power Factor: Greater than 0.9 (0.96 0.99 typical) Total Harmonic Distortion: Less than 20%, 10% typical Occupancy Sensors: Optional factory installed occupancy sensors with photocell are available. Listings & Certifications TUV CE CSA 22.2 ETL listed (UL 1598) - RoHS Compliant IK08 (clear and aisle lens) and all fixtures including Wire Guard Option IEC 60598-1:2015, IEC 60598-2-1:1989, IEC TR 62778:2014 RoHS Compliant EMC: Title 47 CFR 15 Class A and B, ICES-005, EN55015, CISPR 15, EN 61547 LM-79, LM 80 and TM-21 tests and reports are performed in accordance to IESNA standards, per TM-21

Technical Specifications Lumen Output 2 Efficacy Watts Frame Part Number 6.453 172 37 2MS ES40S-B2-06K-2MS 10 9.822 165 60 2MS ES40S-B2-09K-2MS Projected Lumen Maintenance (24/7) TM-21 @ 25 C TM-21 @ 55 C 12 309.000 hours 214.000 hours 9, 10 12.805 157 82 4MS ES40S-B2-12K-4MS 9, 10 15.544 169 92 4MS ES40S-B2-15K-4MS 9, 10 17.818 167 107 4MS ES40S-B2-17K-4MS Ambient Year 1 Year 5 Year 10 25 C 99,64% 95,42% 90,38% 55 C1 99,26% 93,49% 86,76% 21.743 170 128 6MS ES40S-B2-21K-6MS 10 24.874 168 148 6MS ES40S-B2-24K-6MS 10 Over Time Performance (IEC Compliant) Driver failure rate at 5.000h 0,5% 31.088 169 184 4M ES40S-B2-31K-4M 10 36.044 167 216 4M ES40S-B2-36K-4M 43.277 163 266 4M ES40S-B2-43K-4M Median useful life L70B50 Median useful life L80B50 Median useful life L90B50 309.000 h 196.000 h 95.000 h 49.748 168 296 6M ES40S-B2-49K-6M 58.933 165 357 6M ES40S-B2-58K-6M 14 10, 14 67.866 161 421 6M ES40S-B2-68K-6M 2Typical at 220V (EV) and (25 C), 5000K CCT, Clear Lens, +/-10%. Typical CRI 80+. Frosted Lens Multiplier is 0,98. Aisle Lens Multiplier is 0,96. 3000K CCT multiplier is 0,93.

Ordering Example Base Fixture: ES40S-B2-09K-2MS-50-80-CL-EV-CRM-10V or Base Fixture with Options: ES40S-B2-09K-2MS-50-80-CL-EV-CRM-OCCDIM6-2CW-10V SELECT ONE SELECT ONE SELECT ONE SELECT ONE SELECT ONE EV Series-Compliance-Lumens-Frame Color Temp4 CRI Lens Voltage ES40S-B2-06K-2MS 10 ES40S-B2-09K-2MS ES40S-B2-12K-4MS 9,10 ES40S-B2-15K-4MS 9,10 ES40S-B2-17K-4MS 9,10 ES40S-B2-21K-6MS 10 ES40S-B2-24K-6MS 10 ES40S-B2-31K-4M 10 ES40S-B2-36K-4M ES40S-B2-43K-4M ES40S-B2-49K-6M ES40S-B2-58K-6M ES40S-B2-68K-6M 10 30 3000K 40 4000K 50 5000K Other CCT available upon request 80+ (Standard) Other CRI available upon request CL Clear Lens, Wide Distribution FR Frosted Lens, Wide Distribution AL 12 Aisle Distribution EV 220-240V SELECT ONE SELECT ONE IF APPLICABLE, IF NONE, LEAVE BLANK AND MOVE TO CORD & PLUG SELECT ONE IF APPLICABLE, IF NONE, LEAVE BLANK, MOVE TO OPTION SELECT AS MANY AS APPLICABLE, SEPARATE EACH WITH -. IF NONE, LEAVE BLANK, MOVE TO DIMMING Mounting Occupancy Sensors No OCC sensor (Standard) Cord & Plug No cord/plug (Standard) 10,14 Option 14 Dimming 10V CRM5 Cable-ready standard, with a center opening to accept a 20 mm (27mm hole) rod HOOK4 Field installed mounting kit, includes hook and one pair of leveling cables for hook/loop applications Hanger mount also available, sold and packaged separately (see accessories), order as CRM Other mounting options available, contact factory 4, 6, 14 OCCDIM2 Legrand occupancy sensor dimmable with photocell, 2,5 m 4, 6, 14 OCCDIM6 Legrand occupancy sensor dimmable with photocell, 6 m 4, 6, 14 OCCDIM12 Legrand occupancy sensor dimmable with photocell, 12 m 4, 13, 16 TOCC6 IR-TEC occupancy sensor On/Off with photocell, 6 m 4, 13, 16 TOCC12 IR-TEC occupancy sensor On/Off with photocell, 12 m Other occupancy sensors available 1MM2 CORD BLACK WITH THE FOLLOWING 2CW 2m Cord, 15A, no plug 2DW 2m Dimming cord, 15A, 5 Wire, No Plug 5CW 5m Cord, 15A, no plug 5DW 5m Dimming cord, 15A, 5 Wire, No Plug Other cord options available, contact factory 1, 3, 4, 8, 15 BB Battery Back-Up for emergency lighting 4, 15 SRG Fixture installed Surge Protector BOX4 Individual box packaging available 4, 10 CTRWT Counter balance weight for MBR and stem mounting (certain fixtures only) 4, 8, 15, 16 CTRL Control Module Installed 4, 8, 11 CTRLR Control ready harness 4, 15 WG Fixture Wire Guard 4, 13, 16 CTOPEND 10V 0 10V Interface (Standard) DALI DALI interface Cord mounted on top edge of wireway 4, 15 DUST Dust resistant INDR 1, 4 LED modules inverted for indirect lighting When submitting for utility incentives and rebates, please use catalog numbers. When ordering OPTIONS, separate each option with a "-". Catalog number always ends with dimming selection "10V" or "DALI".

Accessories Must be ordered separately. Packaged separately. Type Part Number Description Safety Kit SAFETYCABLE Kit includes (one) 1,5 m aircraft cable with single snap hook, L-bracket, screw and nut. For use with HOOK or stem mounting options. Cable Kit CABLEKIT Kit includes 3 m aircraft Y cables and snap hooks (one pair). Hanger HANGER Kit includes two wire V hangers. Order fixture with CRM mounting option. Occupancy Sensor Wire Guard OWG Wire guard for occupancy sensors, field install. Shipped in separate box. Wireless Programmer for Dimmable Occupancy Sensor(s) Replacement Power Supply OCCDIMPROG Handheld wireless programmer for setup OCCDIMXX dimmable occupancy sensors. Required with OCCDIM8, OCCDIM20 and OCCDIM40 selection. Available upon request. Contact factory for details. End Notes 1. MBR, module setting and INDR fixtures Max Temp 5 C less, typical. BB fixtures (1C to C). Temperatures below -2 have limited switch cycles, consult factory. 2. Typical at 220V (EV) and (25 C), 4000/5000CCT, Clear Lens, +/-10%. Typical CRI 80+. Frosted Lens Multiplier is.98. Aisle Lens Multiplier is.96. 3000K multiplier is.93. 3. Dimensions listed are for the fixture only. See dimensional drawings for measurements with mounting hardware. Weights are approximate and vary by model, if weight is a concern, please contact factory. Weight changes when battery backup is added. 4. Optional add-on. See price list for pricing. 5. Optional CABLEKIT ordered separately. See ACCESSORIES. 6. Wireless programmer required for final field setup. See ACCESSORIES. 7. All cords are 1mm 2 AWG, 600V, and white. 8. Consult factory for orders requiring CTRLR, CTRL and BB. 9. All 4MS units can be configured in the 2M (longer) size for additional cost, please contact factory. 10. Counterweight is available for fixtures with odd number of power supplies which may not hang level from a single point mount. Models affected are ES40S-B2-06K-2MS, ES40S-A1-09K-2MS, ES40S-A1-12K-4MS, ES40S-B2-13K-4MS, ES40S-B2-15K-4MS, ES40S-B2-17K-4MS, ES40S-A1-20K-4MS, ES40S-B2-21K-6MS, ES40S-A1-23K-4MS, ES40S-B2-24K-6MS, ES40S-B2-31K-4M and ES40S-B2-68K-6M. 11. CTRLR includes 5 wires, capped off inside of fixture for use with field installed controls. 12. Rotatable Modules will not rotate when wire guards are installed Wire guards not available with Aisle Lighter Lens. 13. Fixtures ordered with any cord option and an IR-TEC OCC Sensor will have the cord exit from the fixture from the center of the fixture only. CTOPEND not available. 14. Wattstopper OCC Sensor not available on ES40S-B2-58K-6M or ES40S-B2-68K-6M10 15. These options are CE only. 16. CTRL Additional accessories required for full functionality. See ACCESSORIES for available add-on options.

Dimensions & Drawings See End Note #3. Model Length (cm) Width (cm) Height (cm) Weight (kg) 2MS 58,7 22,4 5,4 ~ 3,6 4MS 58,7 28,6 5,4 ~ 4,5 6MS 58,7 35,8 5,4 ~ 6,4 Bottom View 2M 111 22,4 5,4 ~ 7,2 4M 111 28,6 5,4 ~ 8,1 6M 111 35,8 5,4 ~ 9,3 MBR and EMB mounting options adds 2,86 cm to fixture height. MBR on MS (short) fixtures with EMB adds 3,18 cm to fixture height to fixture height. Weights are approximate and vary by model, if weight is a concern, please contact factory. Cable Ready Mount (CRM) Fixture Mounting Box (MBR) Fixture Mounting Box (EMB) TOP VIEW TOP VIEW TOP VIEW Surface Mount Option (when ordering EMB with MBR)

Flex Lighting Solutions Light Distribution at Different Module Angles with Clear Lens 2M and 2MS 9 9 9 4M and 4MS 9 6M and 6MS 9 Block 4008, Ang Mo Kio Avenue 10, #04-06, Techplace 1 9 Australia New Zealand Singapore 61 03 9800 5600 64 07 579 0163 65 6844 2338 www.adlt.com.au www.adlt.co.nz www.adlt.com.sg

North America 7320 W 162nd St. Overland Park KS 66085, USA EMEA ul. Malinowska 28 83-100 Tczew Poland Australia 359-361 City Rd Southbank, VIC 3006 Australia www.flexlightingsolutions.com emeatechsupport.flexlighting@flex.com Phone: +48 735 908 323 All specifications subject to change without notice. Please see www.flexlightingsolutions.com for latest information. All values are typical or design values and series averages. Actual performance may differ as a result of end-user environments and applications. Consult Flex Lighting Solutions with specific inquiries. Copyright 2017, Flex. All rights reserved. No part of this document may be reproduced in any form without the prior written permission of Flex. ES40 Rev: 4.23.18 EU 2018 Flex Lighting Solutions - 7 - ES40 EU www.flexlightingsolutions.com 2017 Flex Lighting Solutions