RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Similar documents
Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Owner s Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Installation and Operation Manual MG-304. Please read this manual carefully before use.

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

CONGRATULATIONS! You are now the owner of the world s best walk-in bathtub from the inventor and manufacturer of acrylic walk-in bathtubs.

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

Installation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012

SYSTEM BASIC WHIRLPOOLS

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Installation Guide BUBBLEMASSAGE. English page T01-A

Destination Collection Whirlpool Bath Installation Instructions

K-870-JA-AA K-872-JA-AA

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

COPPER FREESTANDING TUB

Installation & operating instructions

Important Installation Guide & Operating Instruction

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

RESIN FREESTANDING TUB

ODEON OVE. A. Ordering Information. B. Required Electrical Service T01-C INSTALLATION INSTRUCTIONS

Meditub. Installation & operating instructions. Operating instructions

Access Tubs 3060WCA AIR INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS

Infinity Whirlpool Bath: K-1477-V-AB K-1487-V-AB K-1482-V1-AB K-1484-V1-AB

WALK-IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Access Tubs. Installation & operating instructions COSTCO MODEL # / RIGHT COSTCO MODEL # / LEFT

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

Access Tubs 3238 DUAL ( AIR/HYDRO ) INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS. Costco Item # /394831

Access Tubs. Installation & operating instructions. Costco Item # /394831

IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS

Important Installation Guide & Operating Instruction

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

sanctuary walk-in bathtubs PROUDLY BROUGHT TO YOU BY

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

Model K 520 M Part No

Precedence Bath Whirlpools: K-1355-H1 K-1356-H1

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Whirlpool Bathtub Model Number: MT618

Avenue (HY) Series Installation & Operation Manual

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Advantage Series Bathing System Specifications

Installation Manual for the Manual Control Aquassure Bathtub For Models:

Installation Manual for M-G014 & M-G015

Hourglass Whirlpool Bath: K-1506-H-AB Hourglass Optional Apron: K-1507-AA

K 3.97 M. Specifications or visit our website: In USA call: Part No

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

RA2 Tahoe PRODUCT MANUAL

Assembly instructions. Alexandria Pedicare System ALEXANDRIA. Perfect design. Personal service.

SCHWAN INSTALLATION GUIDE

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Technical Specifications Section 1

Access Tubs 3053 HYDRO INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS


Bubble Massage Bath (Include Electronic Drain)

INSTANT HOT WATER DISPENSER

COLONY COLLECTION OWNER S MANUAL. For your installation, operation, and maintenance needs. Whirlpools Air Baths Combo Baths Soakers

walk-in bathtubs Thank you for choosing an AmeriGlide Sanctuary Walk In Tub, the world s highest quality walk-in bathtub.

BACK WASH INSIDE THE SPA

breeze easytm model # F100-1W

TOEPIA LX ARMREST ASSEMBLY INSTRUCTION

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Model K 240 plus Part No

USER S MANUAL. MODEL NO. CLTL100 (White) CLTL120 (Black) Top-Load Water Cooler

Model K205 M Plus Part No

BURWELL BIDET TOILET SEAT INSTALLATION

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

85 Series USER MANUAL

USER S MANUAL. Bottom-Load Water Cooler MODEL NO. CLBL420

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

INSTALLATION & OPERATIONAL INSTRUCTIONS. Manufactured by ATLANTIS WHIRLPOOLS A Division of Spa World Corp NW 35th Avenue ANSI-Z124.

Model K 330 M Part No

GULFSTREAM PLASTICS LTD.

Triple Gel Coat Walk in Tubs A1A Ultimate Edition

Installation & Operating Guide

BATHBAY COLLECTION INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & OWNER S MANUAL (Refer to individual model sheets for specifications)

WALK IN BATH TUB OWNER S MANUAL

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Luxury Spas Inc. Instruction Manual E-35 Steam Shower. Instruction Manual 1

Installation & Instructions. America s Walk-In Tub. Item # Manufactured by Access Tubs A Division of Spa World Corp NW 35th Avenue

Ella Acrylic Outward Swing Walk In Tub OWNER'S MANUAL

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

English. Your Model Number is: HD1500 IMPORTANT

RECEIVING & INSTALLATION INFORMATION

Food Waste Disposer Instruction Manual

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

APW PSI PRESSURE WASHER

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Model K 280 M Part No

Whirlpool Baths INSTALLATION, OPERATION, AND MAINTENANCE

Welcome! Today s topic: Small Home Repairs. November 14, 2015

SolidFlo G2 Solid Handling Pumps Product Manual

KREEPY KRAULY PROWLER 910 ROBOTIC ABOVEGROUND POOL CLEANER

Transcription:

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual For Model Numbers 2848, 2853, 3153 and 3255 English

RELAX. REVITALIZE. RESTORE. Thank you for choosing a Secure Spa Luxury Spa Unit. Secure Spa Luxury Spa Units offer a safe and secure bathing experience. Our units are thouroughly tested for quality to ensure they will last for years to come. RESPONSIBILITIES OF THE INSTALLER The installer must inspect and water test the product prior to installation to ensure the unit is free of defects or damage. In the event of a problem, the unit should not be installed. If the packaging or product has been damaged, please call your local representative. The spa unit is designed to be installed by a licensed trade person. Licensed electricians and licensed plumbers should be employed to ensure proper installation. The installer assumes all liabilities for installation procedures. Safety warning All instructions listed in this manual should be read and followed carefully. All precautions pertaining to risk of fire, electrical shock, or injury to person(s) must be understood and explained to owner. Use only licensed plumbers and electricians for installation. Be sure you and your contractor are aware of and follow all local plumbing and electrical codes. Install the tub in accordance with the instructions in the manual. Use ONLY the parts and accessories provided or as recomended by the manufacturer. DANGER: RISK OF ELECTRIC SHOCK. The unit MUST be installed and grounded by a qualified service representative using a grounded receptacle and GFCI (Ground-Fault Circuit Interrupter). You must have at least one 20 amp, 120 volt circuit available. A qualified service technician must perform all electrical wiring, service and repair in accordance with all applicable local and national codes. Failure to do so may pose an electrical hazard. Before making any electrical connections, make certain that the electrical power is turned OFF at the breaker, and take measures to ensure that it CANNOT accidentally be turned on again. Building materials and wiring should be routed away from the blower or heat producing components of the system to prevent the risk of heat damage or fire. Make certain you have a flat surface that can support the combined weight of the tub, the water and the user on the levelers. The plumbing connections, hot, cold and the drain should be installed to local codes. 2

Contents 1. 2. 3. Preparing For Installation Luxury Spa Unit Diagram... 4 Testing Procedures (Before Installation)... 5 Installation Preparation... 6 Installation Procedures Installing the Luxury Spa Unit... 6-7 Electrical Installation... 7 Anti-Scald Valve Installation... 8 Installation/Replacement of LED Lights... 8 Door Seal Leaking... 8 Troubleshooting General Troubleshooting... 9 Whirlpool System Troubleshooting... 10 Chromotherapy LED Light Troubleshooting... 10 Anti-Scald Valve Troubleshooting... 10 In-line Heater Troubleshooting... 10 4. Model Specifications & Diagrams 2848 Specs & Diagrams... 11 2853 Specs & Diagrams... 12 3153 Specs & Diagrams... 13 3255 Specs & Diagrams... 14 Hole Placement & Sizes - All Models... 15 3

LUXURY Spa UNIT DIAGRAM 17 18 21 19 20 1 2 3 22 24 23 6 4 5 7 8 25 9 10 26 11 27 12 13 14 28 16 15 LEFT HAND DOOR MODEL Note: Right hand door controls are opposite. 1. Aromatherapy 2. Ten (10) Hydro-Jets 3. Water Flow Diverter 4. Air Control Button 5. Chromotherapy Lights Control Button 6. Easy Access Panels 7. Molded Slip-Resistant 17 Seat 8. Personal Hygiene Therapy/Bidet 9. Low Effort Locking Handle 10. In-line Heater to Maintain Constant Temps 11. Water Pump 12. Ozone Sanitizing Cleaner 13. Left or Right Handed Door 14. Slip Resistant Floor 15. Limited Warranty on Tub, Door Seal & Faucet 16. Wide Door with Less than 4 Step Up 17. Heated Seat and Back 18. 16 Warm Air Jets 19. Water Pump Control Button 20. Air/Hydro Control Button 21. Heated Seat and Back Control 22. Bacteria and Mold Resistant Gel-Coat Finish 23. Built-in Interior Grab Bar 24. Hand-held Shower Wand 25. Easy To Reach Faucet Handle 26. Chromotherapy Lights 27. Massaging Foot Jets 28. Quick Release Drain 4

Testing SPA UNIT Prior to Installation All spa units are 100% water tested at the factory and have passed all inspections. Transportation may loosen fittings and result in leaks. All units must be tested while there is access to all sides of the bathing unit. Fill with Water & Inspect Spa Unit The spa unit should be filled with water and inspected for leaks with the whirlpool and air system on and off. The unit should be thoroughly inspected while filled with water along the door for leaks. It is recommended to test the unit outside by filling the unit with a garden hose. a) Only lift tub by aluminum frame. b) Place unit on a completely level surface in an area where the unit can be drained after thorough testing. c) Using a clean cloth and warm water, wipe down door seal to insure it is free of debris. d) Seal the drain using tape and proceed filling the bathing unit above the highest jet. e) Allow water to stand in unit a minimum of 20 minutes. After the water has been in unit for 20 minutes, inspect all plumbing and seals for leaks. f) Using appropriately rated three prong GFCI extension cord, operate all electrical components (air blower, heater, water pump) for an additional 20 minutes and inspect for leaks. Inspect all unions around pump and heater. g) Ensure all jets are open and working properly. Troubleshooting If the pump/heater/blower/lights do not operate properly. a) Check the breaker. Verify correct electrical circuit and amps of electrical cord. b) Do not run any pumps unless unit is filled with water to proper level. 5 Please Note: Damage due to dry operation of pumps is not covered under warranty.

InstALLATION PREPARATION Check floor, drain is roughed-in and electrical 1. Check Floor 2. a) Clean area of any debris or trash. b) Use 5 level and determine if the floor is level. If the floor is not level, adjust all leveling feet to perfectly level bathing unit (all leveling feet are completely touching the floor and level. This will ensure the door seal works properly). Drain is Roughed-In Check to ensure that drain has been properly roughed-in at the proper location. 3. Electrical Service is Ready Ensure that proper electrical service has been installed at pump location. InstALLATION PRocedures 1. 2. Installing the Spa Unit Install Tub Waste & Overflow Install tub waste & overflow according to instructions included with drain kit. Faucet Installation a) Review installation instruction package furnished with faucet set. b) It is recommended that the hand held shower be installed on the corner closest to the wall to prevent water from leaking off the deck and onto floor creating a safety hazard. Installation Procedures continued on next page 6

InstALLATION PRocedures Continued 3. 4. 5. Install Spa Unit After framing is complete, install spa unit in place to check fit and make certain the unit can be properly leveled. Warning: If unit is not resting on all leveling feet, water will not drain properly and this may cause door to leak. Secure tub frame to the studs using metal straps (not furnished by manufacturer). Check Levelness Check to make sure the unit is completely level by checking tub deck surface and ensure all leveling feet are touching the ground. Plug-in to Electrical Outlet Electrical connection is made by plugging each cord into the GFI protected outlet. 6. 7. Clean Spa Unit After electrical and plumbing connections have been completed, clean the bathing unit and door seal of dirt and debris. Use warm water and a non- abrasive cleaner for cleanup. Check for Leaks Turn pump and blower on and let it run at least 15 minutes. Inspect for leaks while the pumps are running and again after the pumps are turned off. Use hands to check where visual verification is not possible. Installation is not complete until spa unit has been water tested in place and does not leak. The filler panel may be needed for installations greater than 53 up to 60. ELECTRICAL Installation All electrical wiring must be installed in accordance with all local and national codes and instructions. All wiring shall be performed by a licensed electrician. Install one to two, dedicated 20 amp, 120 volt service GFCI circuit(s) depending upon individual tub configuration. 7

Anti-Scald Valve Installation Instructions Refer to manufacturer instructions. Installation Instructions/Replacement ChromOtherapy LED Light Instructions 1) During installation, ensure that the air tube from the air switch on top of the bathing unit is correctly connected to air switch outlet on the LED transformer box. 2) Check to ensure plug from LED is connected to transformer box. 3) The 120 volt plug for the LED transformer box must be connected to a GFI protected outlet. The underwater light may be plugged into the same socket as either the pump or heater. REPLACING LED LIGHTS 1) Disconnect power to bathing unit. 2) Drain bathing unit. 3) Open lens of the fixture. 4) Replace LED light. 5) Verify O ring is not damaged and is properly positioned in groove when replacing the lens. If there is damage or lens does not seal properly, DO NOT refill bathing unit. Note: Do not twist LED light into socket. Use gentle pressure and push LED light into place. Door Seal Leaking If a small leak has been detected around the door, look closely for any build-up of dirt and/or debris. Small collections of water either on the door seal or where the seal meets the door jamb could end up being a minor leak through door seal. 1) Wipe down door seal with a damp soft cloth as well as the surface on the door jamb that comes in contact with the seal prior to filling bathing unit. 2) Once surfaces have been wiped clean, make sure that latch is completely locked forward when door is closed. Note: When draining spa unit, be sure that the door latch is in the locked position (forward). If it is not secure when draining, as water level lowers, pressure on the door will be lessened increasing risk of leak around door. 8

TROUBLESHOOTING Please use the following table to help troubleshoot any problems that may incur after or during the installation process. For futher assistance or to order replacement parts, please contact our Installation Support Team at 1-931-796-6603, extension 302 or 330. TROUBLESHOOTING : GENERAL Symptom Problem Solution Air jets do not start Blower motor starts, but few or no bubbles Bath stops before running 20 minutes Bath does not stop running after 20 minutes. Motor does not start Breaker trips repeatedly Leakage around pump Back jets have no pressure a) No power to blower motor b) Vacuum air switch loose c) Blower motor does not work d) Blue box is bad a) Blower motor is disconnected. b) Blower motor air flow is restricted a) GFCI breaker tripped b) Motor overheated Bath does not stop running after 20 minutes. a) Breaker/GFCI in off position b) Not enough water in tub c) Defective/disconnected wiring a) Shortage between breaker and tub b) Breaker/GFCI defective c) Pump or blower bad a) Unions loose b) Missing O-ring No pressure from back jets a) Set or reset GFCI or breaker b) Check vacuum hose c) Replace blower motor d) Check blue box a) Connect blower motor to air harness b) Clean area around blower motor to ensure adequate ventilation a) Identify source of fault and correct. b) Check for blockage at motor vents. Remove blockage and allow to cool. Replace blue box a) Reset breaker or GFCI b) Add water to cover all jets c) Check/reconnect wiring if needed a) Look for short in wiring b) Replace breaker or GFCI a) Hand tighten unions b) Replace O-ring Check diverter valve 9

TROUBLESHOOTING : WHIRLPOOL SYSTEM Symptom Problem Solution Whirlpool does not start Motor starts all jets are not functioning Whirlpool stops running within 20 minutes a) No power to pump motor b) Faulty air switch in pump motor c) Faulty air actuator d) Air activator tubing disconnected, loose, kinked, plugged or damaged e) Faulty pump motor a) Diverter valve is closed b) Jets are blocked a) GFCi tripped b) Suction is blocked c) Jets are blocked d) Motor overheated a) Reset/set GFCi breaker, check wiring b) Replace air switch c) Replace air actuator d) Connect, tighten, straighten, clean or replace air actuator tubing e) Repair or replace pump motor a) Rotate jet counter clockwise to open b) Remove blockage a) Identify source of fault b) Remove obstruction c) Remove blockage d) Check for blockage at motor vents. Remove blockage and allow motor to cool. Check for suction blockage, remove blockage allow motor to cool. Check for jet blockage, remove blockage allow jet to cool. TROUBLESHOOTING : CHROMOTHERAPY LED LIGHTS Refer to manual provided with bathing unit. TROUBLESHOOTING : ANTI-SCALD VALVE Check manufacturer s instructions provided with valve. TROUBLESHOOTING : IN-LINE HEATER Refer to manual provided with bathing unit. 10

MODEL 2848 Specifications & DIAGRAMS Rough-In Dimensions Width: 54.00, Depth: 28.00 & Height: 36.50 2848 - ToP VIEW 2848 - SIDE VIEW Maximum Water Level 11

MODEL 2853 Specifications & DIAGRAMS Rough-In Dimensions Width: 60.00, Depth: 28.00 & Height: 36.50 2853 - ToP VIEW 2853 - SIDE VIEW Maximum Water Level 12

MODEL 3153 Specifications & DIAGRAMS Rough-In Dimensions Width: 59.00, Depth: 30.375 & Height: 36.50 SS3153 - ToP VIEW 3153 - SIDE VIEW Maximum Water Level 13

MODEL 3255 Specifications & DIAGRAMS Rough-In Dimensions Width: 60.75, Depth: 31.50 & Height: 36.50 3255 - ToP VIEW 3255 - SIDE VIEW Maximum Water Level 14

Hole Sizes & Placement Hole Sizes - ALL Models 2848 & 2853 HOLE PLACEMENT 3153 HOLE PLACEMENT 3255 HOLE PLACEMENT 15

NOTES

NOTES

Still have questions? Contact our Installation Support Team! 1-931-796-6603, Extension 302 or 330 RELAX.REVITALIZE.RES TORE. PO Box 10, Hohenwald, TN 38462 1-855-SPA-N-TUB (1-855-772-6882) marketing@securespa.com www.securespa.com