FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

Similar documents
Sensors and Timers P&S. designed to be better. A COMPLETE LINE FOR ENERGY SAVINGS AND CONVENIENCE.

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Versatile wall switch sensors maximize payback and simplify code compliance

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Decorator Slide Dimmers & Fan Speed Controls

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Mini Product Guide.

The most complete line of proven safety solutions.

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Never forget to turn the lights off again. Motion Sensors

ENERGY EFFICIENCY EXPERTS

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

ASHRAE October 18, 2013

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Wireless Plug Load Control

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Ever evolving energy code requirements and the large demand for energy

Sensors and Detectors

Maestro 0 10 V Dimmer Sensor

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

0ACDT2000MV Ultasonic/Infared Occ Sensor

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

LIGHTING CONTROLS

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

WSA120: New Energy Codes and Lighting Controls

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Residential Occupancy & Vacancy Sensors

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

VESICA LINEAR SUSPENDED VES L

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

H-MOSS Occupancy Sensors Control Units and Add-A-Relay

Wiremold. Evolution Series Boxes now available for ceilings. Evolution Series Ceiling Boxes

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Installation Instructions

Lighting Application Guide for K-12 Classrooms

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Office Title Solutions

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Interior Control Solutions

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

The Power To Supply... All Your Electrical Products

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Installation Instructions

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

High Performance Lighting. Terry Egnor Senior Consultant NBI

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Lighting Management Solutions

ANSI/ASHRAE/IES

Code Review TITLE PRESENTED BY POURIA NIKNAM

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Low-Voltage Occupancy Sensors

Automatic swing door solutions. We make access in life smart and secure.

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS

California Title Design Guide for Smart Lighting Control and Energy Solutions

Code Compliance Commercial Application Guide

Infrared Ceiling Mount Sensor

Infrared Wall Mount Occupancy Sensor

Infrared Ceiling Mount Sensor

National Grid Small Business Program Rebate Manual

Wireless Wall-Mount Sensor

Supporting the Requirements of EPAct 2005 Tax Deductions

Reduce lighting energy costs with controls

Wireless Indoor Lighting Control System

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Lighting Control Solutions for Parking Facilities

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Energy Management Products

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

ANSI/ASHRAE/IES

180 Degree Ceiling Mounted Occupancy Sensors

LIGHTING CONTROL DEVICES

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Here we see the list of auto shutoff controls we will cover in the next few slides

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

SECTION LIGHTING CONTROLS

Education Title Solutions

Indoor Controls. SpaceWise SWZG2. Wireless technology

TITLE 24 ICONOGRAPHY. Iconography System

CONTENTS SENSOR SWITCH

Transcription:

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR INNOVATION AND RELIABILITY THAT SPANS OVER 120 YEARS. TODAY, PASS & SEYMOUR PRODUCTS ARE SYNONYMOUS WITH QUALITY, AND RECOGNIZED AS THE NAME TO TURN TO FOR RELIABLE ELECTRICAL WIRING DEVICE SOLUTIONS THAT WORK. IT S A REPUTATION WE RE PROUD TO CONTINUE AS WE EXPAND OUR LINE OF ENERGY CODE-COMPLIANT LIGHTING CONTROL SENSORS FOR VIRTUALLY EVERY COMMERCIAL INSTALLATION.

SENSING OPPORTUNITIES for you and your customers. New energy code requirements and a growing demand for energy savings are making sensors a must-have for many of your commercial customers. With additional updates for all major codes on the horizon, building owners are scrambling to ensure compliance on all of their projects from renovations to new construction. Fortunately, the full line of Pass & Seymour Sensor solutions are reliable and code-compliant creating a perfect opportunity for you to build your business, and for your customers to save money through tax incentives and reduced energy use. SENSING CHANGE: NEW COMMERCIAL ENERGY CODE REQUIREMENTS. Virtually all jurisdictions at the state, regional and local levels have or will be adopting mandatory energy codes requiring automatic lighting controls. These code provisions will include: ASHRAE 90.1 2010 Auto-on 50% or less or Manual-on Automated shutoff Space control Exterior lighting control Daylighting Receptacle control Commissioning IECC 2012 ASHRAE compliance OR: - Automated shutoff - Space control - Exterior lighting control - Light level reduction - Daylighting - Commissioning California Title 24 2013 Automated shutoff Space control Exterior lighting control Daylighting Receptacle control Commissioning OFFICES CONFERENCE ROOMS RESTROOMS LUNCH/BREAK ROOMS UTILITY/STORAGE ROOMS CLASSROOMS

OFFICES COME IN ALL SHAPES AND SIZES. WHILE THEY CAN VARY GREATLY FROM BUILDING TO BUILDING, THERE ARE A FEW GUIDELINES TO FOLLOW WHEN BRINGING THEM UP TO CODE. SOLUTIONS THAT MAKE PERFECT SENSE PTWSP250 When wall switch sensors are specified, consider our easy-toinstall PLUGTAIL PASSIVE INFRARED (PIR) WALL SWITCH SENSOR. 180 degree PIR coverage Built-in light level indicator Adjustable sensitivity and time delays WDT200 CSD1000 For small offices (up to 12 x 12 ) with a single occupant performing primarily stationary duties such as computer work, we recommend our BI-LEVEL DUAL TECHNOLOGY WALL SWITCH SENSORS. Designed to work even with obstructions, they easily replace standard toggle switches. Bi-level control of two loads from same box 1,050 sq ft coverage Sensitivity adjustment For large, spacious executive offices (18 x 15 ), we recommend our DUAL TECHNOLOGY CEILING SENSORS. These unobtrusive devices blend into any décor and are not impacted by furniture layout. Adjustable sensitivity and time delay Motion coverage from 300 to 2,200 sq ft No false offs Multiple logic options For offices with suspended lighting fixtures or other potential obstructions, we recommend our WIDE ANGLE PIR OCCUPANCY SENSOR. Wall or ceiling mounting options Adjustable PIR sensitivity and time delays Motion coverage of 40 x 30 WA1001 ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: PIR Occupancy/Vacancy Sensor (OS300S) PIR Occupancy/Vacancy Sensor with Neutral (WSP101) Bi-Level PIR Occupancy/Vacancy Sensor (OSR300S) Bi-Level PIR Occupancy/Vacancy Sensor with Neutral (WSP201) PIR Occupancy Sensor (WSP250) PIR Ceiling Sensor (CS500) 2 www.legrand.us/passandseymour

OFFICES Pass & Seymour Sensors 3

4 www.legrand.us/passandseymour CONFERENCE ROOMS

CONFERENCE ROOMS ARE DESIGNED IN A RANGE OF SIZES AND SERVE A VARIETY OF PURPOSES FROM MEETINGS TO TRAINING TO INFORMAL GATHERINGS. THESE ROOMS TYPICALLY HAVE TWO LIGHTING ZONES ONE FOR GENERAL LIGHTING AND ONE FOR FRONT-END LIGHTING AND MAY HAVE MULTIPLE ENTRANCES. SOLUTIONS THAT MAKE PERFECT SENSE CSD1000 WA1001 In general, ceiling sensors are the most effective option for conference rooms since they have a bird s eye view of the room and are not impacted by layout or occupant location. The DUAL TECHNOLOGY CEILING SENSOR fits that bill with its clean, low-profile look that blends into the décor. Adjustable sensitivity and time delay Motion coverage from 300 to 2,200 sq ft No false offs Multiple logic options For conference rooms with suspended lighting fixtures, or where a wide area of coverage is required, we recommend our WIDE ANGLE PIR OCCUPANCY SENSOR. Wall or ceiling mounting options 180 degree coverage Integrated light level sensor Adjustable time delay Motion coverage of 40 x 30 When ceiling sensors are not a viable option, we recommend our BI-LEVEL PIR OCCUPANCY/VACANCY SENSORS Provides high immunity to RFI and EMI Compact design replaces traditional wall switch Integrated light level sensor works from 10 to 150 footcandles OSR300S ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: PIR Ceiling Sensor (CS500) Dual Technology Sensor (WDT100) Bi-Level Dual Technology Sensor (WDT200) PIR Occupancy/Vacancy Sensor (OS300S) PIR Occupancy/Vacancy Sensor with Neutral (WSP101) Bi-Level PIR Occupancy/Vacancy Sensor with Neutral (WSP201) Pass & Seymour Sensors 5

IN VIRTUALLY EVERY COMMERCIAL INSTALL, FROM HOTELS TO SCHOOLS, OFFICE BUILDINGS TO HEALTHCARE FACILITIES, YOU WILL GENERALLY SEE TWO TYPES OF RESTROOM CONFIGURATIONS: MULTI-USER RESTROOMS WITH PARTITIONS AND SINGLE-USER RESTROOMS WITHOUT PARTITIONS. PERFECT SENSE FOR RESTROOMS CSU600 /1100/2200 For restrooms with one to two stalls (intermittent usage), you must choose a sensor designed with ultrasonic sensing technology. That s because the detection function extends beyond most obstacles. In nearly every instance we recommend our ULTRA- SONIC OCCUPANCY CEILING SENSORS for their clean design and unobtrusive appearance. For two enclosed stalls, an alternative installation would be to enable control of one lighting load and an exhaust fan with a DUAL TECHNOLOGY WALL SWITCH SENSOR instead of a standard toggle switch. If both fan and lights are on the same circuit, use a single relay model. WDT100 WSP250 For traditional energy-efficient on/off occupancy sensing, we highly recommend our PASSIVE INFRARED WALL SWITCH SENSORS. These dependable devices not only sense movement, but detect natural light levels so they only turn on when needed. 180 degree coverage Adjustable time delay and sensitivity Saves up to 60% on energy use ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: PIR Occupancy/Vacancy Sensor (OS300S) PIR Occupancy/Vacancy Sensor with Neutral (WSP101) Bi-Level PIR Occupancy/Vacancy Sensor with Neutral (WSP201) Dual Technology Sensor (WDT200) PlugTail PIR Occupancy Sensor (PTWSP250) Dual Technology Ceiling Sensor (CSD1000/1000LV) 6 www.legrand.us/passandseymour

RESTROOMS Pass & Seymour Sensors 7

8 www.legrand.us/passandseymour LUNCH/ BREAK ROOMS

WITH LARGER CONTROLLABLE LOADS AND INTERMITTENT OCCUPANCY PATTERNS, LUNCH AND BREAK ROOMS ARE A GREAT PLACE FOR YOUR CUSTOMERS TO ELIMINATE UNNECESSARY LIGHTING AND SEE MEASUREABLE ENERGY SAVINGS. PERFECT SENSE FOR LUNCH/BREAK ROOMS WDT200 CS500 OSR300S DUAL TECHNOLOGY SENSORS at each doorway permit multilocation lighting control for one or two loads. Eliminates false triggers and provides immunity to RFI and EMI Zero crossing for long relay life Auto adjustable time delays CEILING SENSORS are also a good option for lunch and break rooms since they re unobtrusive, have a bird s eye view and are not impacted by layout or occupant location. Adjustable sensitivity and time delay Motion coverage from 300 to 2,200 sq ft No false offs Multiple logic options In instances where ceiling sensors can t be installed, we recommend one of our WALL SWITCH OCCUPANCY SENSORS: Easily detect small and large movements 180 degree sensing Built-in feature that keeps device off when there s enough natural light Multi-way sensor for rooms with more than one entrance ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: Wide Angle PIR Occupancy Sensor (WA1001) PIR Occupancy/Vacancy Sensor (OS300S) PIR Occupancy/Vacancy Sensor with Neutral (WSP101) Bi-Level PIR Occupancy/Vacancy Sensor with Neutral (WSP201) Bi-Level Dual Technology Sensor (WDT200) Dual Technology Sensor (WDT100) Pass & Seymour Sensors 9

SINCE UTILITY AND STORAGE ROOMS ARE TYPICALLY USED ONLY FOR BRIEF PERIODS THROUGHOUT THE DAY, WE RECOMMEND CHOOSING ONE OF THESE TWO SIMPLE SENSOR INSTALLATION OPTIONS. PERFECT SENSE FOR UTILITY/STORAGE ROOMS RT12 Instead of installing a traditional toggle switch, go with a DIGITAL TIMER WALL SWITCH. It provides convenient pushbutton control to turn lights on for the brief intervals when lighting is required. RT1 If your customer prefers turning lights on and off automatically, install a DUAL TECHNOLOGY WALL SWITCH SENSOR. Its high sensitivity to small and large movements, aesthetically pleasing design, and variety of control features make it a convenient, reliable option. WDT100 ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: Ultrasonic Occupancy Sensor (CSU600) Bi-Level Dual Technology Sensor (WDT200) 10 www.legrand.us/passandseymour

UTILITY/ STORAGE ROOM Pass & Seymour Sensors 11

12 www.legrand.us/passandseymour CLASSROOMS

LIKE LIBRARIES AND READING ROOMS, CLASSROOMS ARE DEFINED AS ROOMS WITH LITTLE OR INTERMITTENT MOTION FOR EXTENDED PERIODS OF TIME. TYPICALLY, SENSORS SHOULD BE INSTALLED NEAR THE TEACHER S DESK IN ORDER TO DETECT MOTION WHEN CLASS IS NOT IN SESSION AND THE TEACHER IS WORKING. PERFECT SENSE FOR CLASSROOMS For classrooms of every size, we recommend installing an OCCUPANCY/VACANCY WALL SWITCH SENSOR near the teacher s desk in order to detect motion when class is not in session and the teacher is working. Provides high immunity to RFI and EMI Compact design replaces traditional wall switch Integrated light level sensor works from 10 to 150 foot candles OSR300S CSD1000 For large classrooms with minimal obstructions, we recommend our DUAL TECHNOLOGY CEILING SENSOR. Adjustable sensitivity and time delay Motion coverage from 300 to 2,200 sq ft No false offs Multiple logic options For classrooms with hanging light fixtures or other objects, we suggest installing our WIDE ANGLE PIR OCCUPANCY CEILING SENSOR. Adjustable PIR sensitivity Adjustable time delay of 15 sec 30 minutes Motion coverage from 300 to 1,200 sq ft WA1001 ADDITIONAL SENSORS FOR THIS APPLICATION INCLUDE: PIR Ceiling Sensor (CS1200) PIR Occupancy/Vacancy Sensor (OS300S) PIR Occupancy/Vacancy Sensor with Neutral (WSP101) Bi-Level PIR Occupancy/Vacancy Sensor with Neutral (WSP201) Dual Technology Sensor (WDT100) Bi-Level Dual Technology Sensor (WDT200) Pass & Seymour Sensors 13

USE THIS HANDY CHART TO IDENTIFY THE P&S SENSORS THAT MAKE PERFECT SENSE FOR YOUR COMMERCIAL INSTALLATIONS. OFFICES CONFERENCE ROOMS RESTROOMS LUNCH/ BREAK ROOM UTILITY/ STORAGE ROOM CLASSROOMS UNIQUE AREAS CEILING MOUNT Product Coverage PIR Ceiling Sensor* 360, up to 500 sq ft CS500 CS500 CS500 CS500 PIR Ceiling Sensor* 360, up to 1,200 sq ft CS1200 CS1200 PIR Ceiling Sensor 360, up to 1,200 sq ft CS1200LV CS1200LV Ultrasonic Occupancy Sensor* Ultrasonic Occupancy Sensor* Ultrasonic Occupancy Sensor* 360, 500 sq ft one sided CSU600 CSU600 360, 1,100 sq ft two sided CSU1100 CSU1100 360, 2,200 sq ft two sided CSU2200 CSU2200 Dual Technology Sensor* 360, up to 1,000 sq ft CSD1000 CSD1000 CSD1000 CSD1000 Dual Technology Sensor 360, up to 1,000 sq ft CSD1000LV CSD1000LV CSD1000LV CSD1000LV CEILING OR WALL MOUNT WALL MOUNT Long Range PIR Occupancy Sensor* Wide Angle PIR Occupancy Sensor* PIR Occupancy/Vacancy Sensor with Neutral Up to 90 linear ft Up to 1,200 sq ft WA1001 WA1001 WA1001 WA1001 WA1001 Major Coverage: 35 x 30 ; Minor Coverage: 20 x 15 WSP101 WSP101 WSP101 WSP101 WSP101 WSP101 HS1001 Bi-Level PIR Occupancy/ Vacancy Sensor with Neutral PIR Occupancy Sensor PlugTail PIR Occupancy Sensor PIR Occupancy/ Vacancy Sensor Bi-Level PIR Occupancy/ Vacancy Sensor Major Coverage: 35 x 30 ; Minor Coverage: 20 x 15 Major Coverage: 900 sq ft; Minor Coverage: 300 sq ft Major Coverage: 900 sq ft; Minor Coverage: 300 sq ft Major Coverage: 1,050 sq ft; Minor Coverage: 300 sq ft Major Coverage: 1,050 sq ft; Minor Coverage: 300 sq ft WSP201 WSP201 WSP201 WSP201 WSP201 WSP201 WSP250 WSP250 PTWSP250 PTWSP250 OS300S OS300S OS300S OS300S OS300S OS300S OSR300S OSR300S OSR300S OSR300S OSR300S OSR300S Dual Technology Sensor 1,050 sq ft WDT100 WDT100 WDT100 WDT100 WDT100 WDT100 WDT100 FIXTURE MOUNT Bi-Level Dual Technology Sensor PIR Sensor with Interchangeable Face PIR Sensor Dimmer with Neutral 3-Way PIR Occupancy/ Vacancy Sensor 3-Way PIR Occupancy/ Vacancy Sensor** High Bay Dry Location Sensor High Bay Wet Location Sensor 1,050 sq ft WDT200 WDT200 WDT200 WDT200 WDT200 WDT200 WDT200 600 sq ft RW600BTC 600 sq ft RWDU500 RWDU500 600 sq ft RW3U600 RW3U600 600 sq ft RW3U603 RW3U603 60 ft. x 20 ft. @ 40 ft. mounting height PSHB120277L1 40 ft. diameter @ 20 ft. mounting height PSHB120277L2 60 ft. diameter @ 60 ft. mounting height PSHB120277L3 40 ft. diameter @ 20 ft. mounting height PSHB120277WL2 60 ft. diameter @ 60 ft. mounting height PSHB120277WL3 *Requires Power Pack **California Title 24 compliant For additional information, go to www.legrand.us/passandseymour.

Legrand/Pass & Seymour P.O. Box 4822 Syracuse, NY 13221-4822 800-776-4035 www.legrand.us/passandseymour 2012, Legrand All Rights Reserved BR1807 9/12 EMA/CGXTP For additional technical or application-specific information, call 800-223-4185 or visit our website at www.legrand.us/passandseymour. We re eager to put our expertise to work for you. Distributed by: Legrand, North America 60 Woodlawn Street West Hartford, CT 06110 1.877.BY.LEGRAND (295.3472) www.legrand.us 570 Applewood Crescent Vaughan, Ontario L4K 4B4 905.738.9195 www.legrand.ca