CONTROLLED CHILLED BEAM PUMP MODULE

Similar documents
CONTROLLED CHILLED BEAM PUMP MODULE

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Benefits Offered by Passive Dehumidification Wheel Speed Control

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

ASCENDANT CONVENTIONAL COOLING, ACTIVE DESICCANT DEHUMIDIFICATION SYSTEM ASCENDANT LOW DEW POINT EFFICIENT & EFFECTIVE

HEALTHCARE SURGERY VENTILATION HUMIDITY CONTROL

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

b.) Technical Information:

Variable Refrigerant Flow (VRF) Systems

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

HVAC 101. H V A C S y s t e m s

Technical Assignment 3 11/15/04. Executive Summary

HVAC Controls Upgrades: Requirement Details ( )

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

APPLICATION GUIDE BEAMS

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

The ultimate fresh air solution.

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

Job Name Control Systems Description Date

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Increase your flexibility.

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

COMcheck Software Version Review Mechanical Compliance Certificate

THE ULTIMATE ROOFTOP SOLUTION

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

THE RIGHT SPEC. RIGHT NOW.

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Variable Refrigeration Flow Systems Overview 10/11/2016

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

The electrical wattage needed by the circulator is:

COMcheck Software Version Mechanical Compliance Certificate

Trane Family of Terminal Products

Summary Comparison of Simulation Program Features

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

ENGINEERING. Edition No. 13 October 2002

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

HVAC Controls Upgrades: Requirement Details ( )

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Hydronic Mechanical Panels

CHILLED WATER SYSTEM 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

The Book of AERMEC NRL Sequence of Operation

Best Practices for Condensing Boilers

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

1 - This title will copy onto other forms Date

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

DISTRIBUTION SYSTEMS. Water Piping and Pumps

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Dream Big, Think Small: Innovative System Has All

Engineered for flexibility and performance

DADANCO Technical Paper

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

June Copyright Climatec

Chilled Water DOAS Fan Powered Terminal Units

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

ApacheHVAC in VE 2012

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

EZ Plate Instantaneous

Smardt vs. McQuay Comparison of Standard Options and Other Benefits < 400 tons

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

FDCLP2 Low Profile, Series Flow Fan Powered Terminal Unit

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

CONTENTS. B. System Design and Performance Requirements

Chilled Beams. Getting a Warmer Reception

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

7. MECHANICAL SYSTEM DESIGN

DIGI-VAV APPLICATIONS

Electric Coils. Blower Coils. Product Information

Modular Active. Chilled. Beams

BOOK 2 SPECIFICATIONS

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

Dehumidifying with Dedicated Outdoor Air

LG VRF Systems. Air Conditioning Technologies

New and Emerging HVAC Technologies. Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering

Variable refrigerant flow (VRF) systems

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Mechanical Technical Report 3. Mechanical Systems Existing Conditions Evaluation

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Transcription:

FIRST COST SAVINGS PROACTIVE CONTROL CONTROLLED CHILLED BEAM PUMP MODULE

Active condensation control system effectively eliminates chilled beam condensation High efficiency, variable speed pump uses a fraction of the energy used by traditional pump loops Plug and Play Control System optimizes water temperature for each zone NEUTON is the HVAC industry s first smart, plug-and-play controlled chilled beam pump module (CCBPM) for reducing chilled beam system installation and operational costs. NEUTON is a factory-built and pre-tested package complete with its own powered integrated direct digital controller, chilled and hot water connections, valves, variable-speed electronically commutated motor (ECM) pump, smart sensors, and other unique features. The device provides active condensation control effectively addressing one of the key design concerns regarding active chilled beams. Partnered with the Pinnacle dedicated outdoor air system (DOAS) and active chilled beams, NEUTON is the key to the 3fficiency system. An efficient hydronic system, 3fficiency provides a safe and effective alternative to Variable Refrigerant Flow (VRF). Any concerns regarding refrigerant regulations or the dangerous possibility of a refrigerant leak are eliminated with 3fficiency. NEUTON manages the water system for 3fficiency to allow for a building level occupant control superior to all other systems.

NEUTON OPTIMIZING CHILLED BEAMS. Active condensation control system effectively eliminates chilled beam condensation Reduces cost of a chilled beam installation by 30% or more by allowing for smaller pipe diameters, fittings and feet of pipe Cuts the amount of zone piping and fittings in half by removing the need for building-level secondary loops for the chilled beams Simplifies installation, controls, and beam system commissioning NEUTON is available in two configurations: NEUTON 2 has a single actuator for summer/winter switchover and NEUTON 4 uses dual actuators allowing for simultaneous heating and cooling. Additionally, configurations are available in two different pump capacities. NEUTON CCBPM-8-12, delivers 8 gallons per minute (gpm) of water flow and an external head pressure of 12 feet produced by the pump. NEUTON CCBPM-11-12 has the capacity of 11 gpm at 12 feet of external head. Both use the same pump, but the Cv of the valves are different, allowing you to select the best NEUTON for the application. NEUTON-Multiple Zone is a variation on the original NEUTON allowing individual comfort control in multiple zones for individual comfort management. This variation has been provided because of the increase in building designs that allow for individual temperature controls for offices (or similarly small zones). NEUTON-Multiple Zone allows more personalized temperature, humidity, and, ultimately, comfort control across multiple zones. FROM BEAMS Increases beam cooling and heating output allowing all coil passes to be used for cooling and heating Eliminates the confusion and cost of customized zone control development and installation Improved response to occupied/unoccupied and low load conditions - novel control sequences vary water flow and/or temperature, as needed, to accommodate changes in zone load conditions TO BEAMS NEUTON 4 DUAL ACTUATOR FROM BEAMS CLOSED TO BEAMS CLOSED NEUTON 2 SINGLE ACTUATOR Each configuration is available in low flow CCBPM-8-12 or high flow CCBPM-11-12. 3

DESIGN ADVANTAGES MAXIMUM EFFICIENCY The intuitiveness of NEUTON eliminates the expense of a separate chiller, boiler and secondary water distribution system associated with conventional chilled beam HVAC designs. Instead of expensive secondary piping loops, each NEUTON blends and re-circulates return water within its zone to convert typical 42 F and 140 F primary loop water temperatures to optimal 58 F or 100 F chilled beam discharge temperatures, which prevents cooling mode condensation and heating season heat stratification. Each NEUTON can control up to 10 chilled beams, depending upon the water flow rate required. The 3fficiency system combines NEUTON with the Pinnacle DOAS and active chilled beams for a hydronic system that is safer and more efficient than the refrigerant-based VRF. Important design advantages include: Very high energy efficiency Very low primary airflow requirements Low noise levels Reduced filter maintenance central location not room by room Ideal air distribution Improved indoor air quality excellent outdoor air delivery Excellent humidity control Eliminates condensate management problems PINNACLE VENTILATION SYSTEM 68 F 44 gr Primary air supplies 100 CFM, 44 grain dry air to each beam 87 F 132 gr Building plenum space ACTIVE CHILLED BEAMS Chilled beam 4x PA CFM Ductwork 50% Smaller Reduced plenum height NEUTON PUMP MODULE Active condensation control system effectively eliminates condensation concerns, reduces chilled beam install costs, and saves energy. 62 F 58 F Serve the beams with conventional chilled/hot water temperatures no more need for centralized secondary loops for chilled beams. 4

NEUTON Energy Use Comparison for Three Energy Efficient Systems: The chart to the right shows energy modeling completed for a 250,000 sq.ft. school. NEUTON pump modules combined with chilled beams result in the most energy Annual Energy Cost $80,000 $70,000 $60,000 $50,000 $40,000 $30,000 $20,000 $10,000 Pumps Heating Cooling Air System Fans efficient system available. $0 Baseline precool DX/ recovery and WS Heat Pumps Pinnacle serving Water Source Heat Pumps Pinnacle serving Chilled Beams with NEUTON Design Approach Substantial Pump Energy Savings Example Pump Energy Used (Watts) 400 350 300 250 200 150 100 50 0 24,000 19,200 14,400 Chilled Beam Cooling Power (BTU) On/Off Approach NEUTON Standard efficiency pump (on/off) vs. high efficiency ECM variable speed pump served by NEUTON control logic To the left is a graphic representation of energy use comparison between the baseline cycled constant speed zone pump and the high efficiency variable speed zone pump used in NEUTON. A high-efficiency ECM motor combined with substantial power reduction offered by the NEUTON variable flow pump results in significant energy savings over a traditional, constant flow on/off design approach. Three cooling conditions are analyzed above: peak coil cooling power (24,000 BTUs), 80% of peak (19,200 BTUs) and 60% of peak (14,400 BTUs). The constant speed pump operates to deliver a constant flow of 6 gpm at a 13 foot pressure head cycled on and off during part load. The NEUTON ECM variable flow pump runs continuously, but varies the flow from 6 gpm down to 3 gpm, greatly reducing the pump energy used. NEUTON USES AN AVERAGE OF 80% LESS PUMP ENERGY TO ACHIEVE THE SAME BEAM COOLING OUTPUT 5

SIMPLIFIED DESIGN. STREAMLINED INSTALLATION. Optional BacNet Communications Link (field wiring by contractor) 14 7 3 9 10 12 13 1 2 11 4 5 8 6 Component Parts 1) Integrated electrical, DDC controls panel 2) Electronically Commutated Motor (ECM) high efficiency, variable speed pump 3) Hot water control valve 4) Chilled water control valve 5) Chilled water return 6) Hot water supply 7) Zone loop return connection 8) Chilled water supply 9) Hot water return 10) Zone supply water connection 11) Pete s plugs for pressure and flow measurement 12) Zone supply water thermistor 13) Pump Isolation Valves 14) ZS Pro Sensor Zone Controller The zone pump, beam water temperature sensor, control valves, associated electrical and controls are all factory wired and tested Only field connections are smart sensor, BAS (if used) and main power (208/230/1Ph) On-board controls specifically developed and optimized for chilled beam zone control (plug and play) All pipe connections use swivel half-union adapters with face gasket designed to easily connect to standard 1 male fittings

NEUTON COOLING MODE (4 pipe primary loop shown) The chilled water control valve slowly injects chilled water from the primary loop as recirculated secondary beam loop water is discharged through the check-valve into the primary chilled water return loop. The hot water control valve is in the full bypass position and the corresponding check valve is closed. Conventional 42ºF chilled water can be utilized within a single primary loop to serve both the chilled beam zones and the dedicated outdoor air system. HEATING MODE (4 pipe primary loop shown) The hot water control valve slowly ejects a metered amount of recirculated secondary beam loop water while the corresponding check-valve allows for injection of water from the hot water supply loop. The chilled water control valve is in the full bypass position and the corresponding check valve is closed. Conventional 120ºF hot water can be utilized within a single primary loop to serve both the chilled beam zones and the dedicated outdoor air system Note: Only one of multiple beams in zone shown. Note: Only one of multiple beams in zone shown. Note: Only one of multiple beams in zone shown. Note: Only one of multiple beams in zone shown. 58 F 90 F 100 F Knob in Partial Open (modulating) Knob In Mode Closed CWR CWS HWS (Closed) Mode HWR (Closed) Chilled Water Supply Chilled Water Return Knob in Partial Open (modulating) Mode HWR 90 F CWR CWS (Closed) (Closed) HWS 120 F Hot Water Return Knob in Closed Mode Hot Water Supply 7

DESIGN REQUIREMENTS TRADITIONAL VS. NEUTON Traditional Beam Designs Require: Two primary loops are required for both cooling and heating to accommodate the DOAS and beams, requiring second chiller and boiler, plate frame heat exchangers or other modifications. Increased pipe size (substantial cost) required for beam loop due to moderate chilled and hot water temperatures required by the beams Four pipe beam coils, with some coil passes allocated for cooling and others for heating Piping at each zone needs to accommodate four piping runs heating and cooling supply and return lines, valves and couplings. In each zone, contractor needs to install two control valves, condensation sensors, run power to all devices then communicate with space thermostat or BAS signals. Design engineer needs to develop a custom control algorithm then communicate this to the BAS subcontractor then debug Traditional Chilled Beam Piping Layout: Cooling Only FAN COIL UNIT 58 F 50 F 58 F 58 F PLATE FRAME HEAT EXCHANGER PINNACLE DOAS 49 F 58 F PRIMARY PUMP SECONDARY PUMP 51 F CHILLER 8

NEUTON NEUTON Beam Designs Require: A single primary loop with all devices is served by the same traditional chilled and hot water temperatures (beam water temperature set by NEUTON). Primary pipe size (cost) remains small since no change to the chilled or hot water temperatures is required (same temperature to beam zones as DOAS). Two pipe beam coils, with all passes allocated for cooling and heating Only a single supply and return piping run in each zone since two pipe coils are used (half that required by conventional approach) Contractor only needs to install the NEUTON and connect the smart sensor and power to the unit. All valves, DDC controller, electrical and software are factory installed and tested. No controls programming is needed. The optimized algorithms complete with BACnet 6 communications capabilities are standard with each NEUTON. NEUTON installation is approximately 75% of the installed cost associated with traditional chilled beam systems while providing advanced controls and substantial energy savings. NEUTON Chilled Beam Piping Layout: Heating and Cooling - 4 pipe system FAN COIL UNIT 58 F 58 F 58 F 50 F SEMCO NEUTON (one of three) PINNACLE DOAS PRIMARY PUMP 55 F BOILER CHILLER 9

HOW IT WORKS TWO PIPE SYSTEM Installation advantages with a 2 pipe system: Primary water loops only When integrating NEUTON into a novel 2 pipe system layout, additional installation and cost advantages can be recognized. This approach not only reduces the pipe size during cooling and heating as before, but also cuts the length of pipe in half since NEUTON pulls water from and delivers it back to the same pipe loop. This 2 pipe system approach still allows for the use of two pipe beams (same passes for heating and cooling), and provides the complete benefits of the 4 pipe approach. NEUTON Chilled Beam Piping Layout: Heating and Cooling - 2 pipe system FAN COIL UNIT 58 F 58 F 58 F SEMCO NEUTON (one of three) 50 F 56 F PINNACLE DOAS 53 F PRIMARY PUMP CHILLER BOILER 10

NEUTON Impact on pipe diameter, pump size and loop installation cost We can now compare the traditional 4 pipe approach with the novel 2 pipe layout combined with NEUTON. This approach pulls cold water from the single cooling loop (for example) and discharges some quantity of return water back into the same loop. As a result, there is a consistent change in the supply chilled water temperature as it passes through the building. The change is a function of the load on the building. To ensure that there is adequate cooling power left in this loop for the chilled beams serving the last zones served by the loop, the water temperature at the end of the loop is controlled by varying the inlet water temperature and/or flow. The same approach is used for the single heating water loop employed. Due to the need to control these end of the loop temperatures, the delta temperature between the beginning of the loop water and the end of the loop water is not as great as possible with the previous 4 pipe example utilizing NEUTON, but the benefit here is a significant reduction in linear feet of pipe, fittings and installation required. Summary table showing the installation advantage offered by NEUTON compared to the Traditional system using 4 pipe arrangements. Traditional (4 Pipe System) NEUTON (4 pipe system) NEUTON (2 pipe system) Flow Required Pump Power Pipe Diameter Cooling Loop 112 GPM 35 GPM 67 GPM Heating Loop 31 GPM 6.5 GPM 14 GPM Cooling Loop 1.1 HP.2 HP.6 HP Heating Loop.2 HP.04 HP.06 HP Cooling Loop 3" 2" 2" Heating Loop 2" 1" 1.25" Cooling Loop $30,400 $16,600 $8,300 Estimated Installation Cost Heating Loop $16,600 $7,240 $2,150 Secondary Loop (1) Hot and Cold $18,000 $0 $0 Total Installation Cost $65,000 $23,840 $10,450 Note 1: Estimated cost associated with creating a separate secondary water loop to serve the chilled beams (cooling and heating). This would include plate frame heat exchanger, piping, valves and installation. 11

NEUTON CCBPM Sales Brochure - FlaktGroup Semco 2018-02 WWW.SEMCOHVAC.COM NEUTON / 20180926 FläktGroup SEMCO delivers smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than fifty years of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. FläktGroup SEMCO Corporate Headquarters 1800 East Pointe Drive Columbia, Missouri 65201 USA 573.443.1481 sales.semco@flaktgroup.com To learn more about FläktGroup SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com Copyright 2018 SEMCO LLC. All Rights Reserved. SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied upon request on receipt of order. SEMCO is a registered Trademark of SEMCO LLC. Other trademarks and logos in this publication may be property of SEMCO, LLC, its subsidiaries or any of its related companies and/or other organizations or individuals. U.S. patented technology: 5,401,706; 5,496,397; 6,199,388; 6,751,964; 9,625,222.