PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Similar documents
PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Multi Tone Alarm Sounders A

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

INSTRUCTION & SERVICE MANUAL

Explosion Proof Combination Signal db (A) / 5 Joule

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

X10 Mini, Midi & Maxi

AP200 SERIES INTELLIGENT ALARM DEVICES

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

INSTRUCTION & SERVICE MANUAL

AP200 SERIES INTELLIGENT ALARM DEVICES

INSTRUCTION MANUAL (ATEX / IECEx)

Product Manual Standard Asserta Sounder Range

E2S Datasheet v10a

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Xenex Conventional Fire Detection & Alarm System

4) Intrinsic Safety Certification

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Conventional Fire Detection

Optical-Audible Signal Devices

OPERATING AND INSTALLATION

Segnalatori acustici AW-ETH12MD AW-ETH12MD audible warning

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

ATEX. IECEx. culs GOST-R. VdS

Sonos-SB Siren/Beacon

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

INSTRUCTION MANUAL (ATEX / IECEx)

Installation Instructions for W2H Series Signals

Segnalatori acustici AW-ETH20MD Audible warning devices

ELECTRONIC SOUNDER STROBE Model : AVD-C407

YO3 - YO4 / YL4 - YO5 / YL5

XP95 Sounder VAD Base

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

LC1 Modular Ceiling Loudspeaker Range. en Installation note

Interface and EOL Modules 8

Auer - Signal tower ECO Ø70 mm modular

Engineering Guideline. pac- Carriers Type Universal

AUDIBLE SIGNALIZATION

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

SELECT-A-HORN/STROBE SERIES

DB5 Intrinsically Safe Sounder Type DB-5

LB3-PCx50 Premium Cabinet Loudspeakers

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Intellia Sounder Bases and Sounder Beacon Bases

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Technical Manual for the Horn DB1P UL DB1HP UL

The Use of Public Address System to Improve Tunnel Safety - Current Practices. Lim Hock Tay

Part Number Structure ZA 016 L D CT

Audible warning devices for external alarm

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

SOUNDER BASES AND SOUNDER BEACON BASES

PolyGard 2-channel Gas Controller MGC-03

Conventional Audible Visual Range

DB1 Range - HORNS - Up to 103 db(a)

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Half-Dome. the Design-Tower. Compact

DICTATOR Hold-Open Systems for Hazardous Areas

Multi-Gas-Controller MGC2

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Fire Signalling. Signalling Solutions

Installation and user manual for the BiWire / Conventional Repeater Panel

Technical Manual for the Horn - DB1PUL DB1HP UL

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Addressable Detectors & Bases

Universal fault annunciator for panel mounting

The EN54 Part 2 and 4 Fire System

Smoke and Fire Curtains

Part Number Structure ZT 028 L D CT R 15

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

L-Series, Indoor Strobes and Horn Strobes

SERIES 65 ENGINEERING PRODUCT GUIDE

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

LF-4000 Series Conventional Fire Alarm Control Unit

ELECTRONIC PARTS - CATALOGUE

Danfoss gas detection units

Quick Selection Guide Fire Systems LSN Periphery

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

INSTRUCTION MANUAL A131 High Level Audible Warning System

Technical Data. General specifications. Rated operating distance s n 5 mm

DSE ELECTRONIC SIRENS Advantages & Functions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

More Precision. indusensor // Linear inductive displacement sensors

Industrial Signalling

INSTRUCTION MANUAL TABLE OF CONTENTS

Remote alarm indicator and test combination MK2430

BL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab

L-Series, Indoor Strobes and Horn Strobes

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Transcription:

PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible. Easy; significantly shorter assembly and installation times. Economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders. IP 66 IK08 +55 C 40 C EN 54-3 VdS UL 10 Years Schutzart impact-proof housing operating temperature acoustic penetration external tone selection 24 48 V DC 24 48 V DC warranty PRODUCT PA 10 PA 20 DATA Operating range 95 265 V 20 30 V 10 60 V 95 265 V 20 30 V 10 60 V AC 50 60 Hz DC AC 50 60 Hz DC Nominal current consumption 1 20 115 ma 250 900 ma 60 485 ma 75 330 ma 500 1800 ma 120 880 ma Sound pressure level 110 db(a) 120 db(a) Sound level reduction max. 12 db via potentiometer Alarm tones 80 / 4 tones are externally selectable Duty cycle 100 % Operating temperature 40 C... +55 C Storage temperature 40 C... +70 C Relative humidity 90 % Protection system according to EN 6052 IP 66 Protection class II Material PC / ABS blend similar to RAL 3000 (flame red) RAL 7035 (light grey) RAL 9003 (signal white) Cable entry 5x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fine wire with cable end sleeve, AWG 16 Weight 1,060 g 1,050 g 1,200 g 1,090 g 1 Power consumption dependent on operating voltage. OPTIONS/ACCESSORIES I lim t Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit

DIMENSIONS PA 10 PA 20 156 214 190 181 170 Ø 9 190 214 26 170 Ø 9 M20 prepared 21 30 M20 prepared AUDIBLE SIGNALING DEVICES ARTICLE PA 10 PA 20 VERSION RATED VOLTAGE 95 265 V AC 24 V AC 10 60 V DC 95 265 V AC 24 V AC 10 60 V DC Standard housing red 23360640000 23360300000 23360630000 230640000 230300000 230630000 GL/MED housing red 23360640001 23360300001 23360630001 230640001 230300001 230630001 Standard housing grey 23360640055 23360300055 23360630055 230640055 230300055 230630055 GL/MED housing grey 23360640056 23360300056 23360630056 230640056 230300056 230630056 Article numbers for other voltages and versions on request. ARTICLE PA 10 PA 20 Enclosure fitting For connection (daisy-chaining) of several sounders of the PATROL series. 28300000003 Surface gasket Tamper-proof sealing (pack of 4) Panel mount installation kit PATROL Sealing of the sounder installation surface when, e. g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PATROL devices after installation in order to prevent manipulation of the devices. The PATROL devices are also suitable for panel mounting. This kit consists of a plug connector for the electrical contact, as well as all installation materials. 28300000006 28300000002 28300000009

PRODUCTS AUDIBLE SIGNALING DEVICES TONE TABLE 15 evacuation alarm Netherlands NEN 2575 16 evacuation alarm Australia AS2220 18 NFPA 775 Hz Pulsating tone, Australien alert AS1670, ISO8201 23 24 25 26 27 29 30 31 33 34 35 36 43 44 45, (fast), IMO 3d, Germany KTA3901 evacuation alarm 63 725 Hz 65, Sweden SS031711 (all-clear signal) 66 67, Germany KTA3901 (all-clear signal) 68 470 Hz 69 71 82 PFEER (general alarm), UK BS5839-1 (back-up alarm) PFEER (general alarm) 88 300 Hz 10 s 40 s 10 s 90 150 Hz 52 53 2000 Hz 54, Finland (all-clear signal) 1 55, PFEER gas alarm 56 101 102 Sweden SS031711 (local warning) 103 Sweden SS031711 (air raid warning) Sweden SS031711 (emergency signal) 107 Germany KTA3901 (evacuation alarm) 420 Hz 109 Australia AS2220, AS1610, AS1670 110 (fast variable), bell 111 ISO8201 (emergency evacuation signal), USA (evacuation alarm) 470 Hz 112 ISO8201 (emergency evacuation signal) 113 ISO8201 (emergency evacuation signal), sweeping 7s 7s 4 ms 0,7 s Sweden SS031711 (important message (pre-mess)) 4 ms 100 104 725 Hz 680 Hz Sweden SS031711 (emergency signal) 98 1 93 (fast), Horn 97 92 91 340 Hz 83 2200 Hz 77 300 Hz 1 P FA N N E N B E R G. C O M 61, general alarm Finland 46 0,85 s 422 Hz 3,75 s (medium), UK BS5839-1 3,5 s 1600 Hz (fast), UK BS5839-1 0,6 s, France NFC48-265 (fast) 0,3 s 60 0,3 s 0,875 s 0,875 s 13 s 6,5 s 1,8 s 1,8 s 150 ms 150 ms 900 Hz 13 22 880 Hz 0,75 s 0,625 s 0,625 s 1450 Hz 0,69 ms 2850 Hz 970 Hz 59 (fast), UK BS5839-1 11 970 Hz 57 fire alarm, UK BS5839-1 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP no tone 2 1

0, TONE TABLE 115 116 117 IMO (telephone call) IMO (leave ship) IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) 122 Alternating tone 123 Alternating tone 124 Singapore 125 Alternating tone 128 Alternating tone 130 UK BS5839-1 (fire alarm) CONTROL OF THE TONES 20.25 s s 0.25 s 2000 Hz 0.5 s 3 s 0.5 s 2,5 s 7 s 1025 Hz 2,5 s 0.25 s 0.25 s 2400 Hz 0.5 s 0.25 s EN54-3 0.5 s 0.25 s 0.125 s 0.125 s 1025 Hz DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C2 1 2 3 4 5 6 BASIC TONE TONE 1 2 88 57 ON 2 * 128 112 57 ON 2 26 100 93 ON ON 2 61 131 112 ON 9 57 11 82 ON ON 15 131 52 112 ON ON 16 109 52 56 ON ON ON 18 111 57 68 ON 22 16 109 68 ON ON 23 131 52 112 ON ON 24 131 52 131 ON ON ON 25 131 52 92 ON ON 26 2 100 93 ON ON ON 27 123 52 92 ON ON 29 35 52 61 ON ON ON 30 27 52 77 ON 31 131 52 57 ON ON 33 30 52 35 ON ON 34 35 52 93 ON ON ON 35 27 52 110 ON ON 36 146 67 57 ON ON ON 43 131 52 91 ON ON ON 45 2 57 93 ON ON ON ON 52 15 65 82 ON ON 54 46 54 131 ON ON ON 55 131 52 128 ON ON ON 56 82 35 33 ON ON ON ON 59 143 59 101 ON ON 60 131 52 125 ON ON ON ON 65 131 52 93 ON ON ON ON 66 110 52 107 ON ON ON ON ON 69 131 52 110 * factory setting 131 135 UK BS5839-1 (fire alarm, railway crossing) UK BS5839-1 (fire alarm, increased urgency railway crossing) 142 Alternating tone 143 144 Alternating tone 146 147 148 152 France NFS 32-001 (fire alarm) Sweden SS031711 Sweden SS031711 Alternating tone (two tone chime) 900 Hz 650 Hz 0,4 s 650 Hz 2 s DIP-SWITCH EXTERNAL TONE SELECTION (SETTING OF BASIC TONE) C1 C2 C1+C2 1 2 3 4 5 6 BASIC TONE TONE ON 71 131 52 93 ON ON 77 61 52 122 ON ON 82 131 52 83 ON ON ON 83 56 2 82 ON ON 88 2 57 128 ON ON ON 90 131 52 125 ON ON ON 91 30 52 110 ON ON ON ON 92 33 52 57 ON ON 93 2 128 57 ON ON ON 97 2 63 93 ON ON ON 100 131 52 125 ON ON ON ON 101 98 102 65 ON ON ON 103 131 65 147 ON ON ON ON 104 103 65 101 ON ON ON ON 109 16 52 22 ON ON ON ON ON 110 131 61 91 ON ON 112 2 57 128 ON ON ON 113 52 123 104 ON ON ON 115 117 116 44 ON ON ON ON 116 117 93 125 ON ON ON 117 93 116 125 ON ON ON ON 123 27 52 77 ON ON ON ON 124 53 83 2 ON ON ON ON ON 130 2 107 67 ON ON ON 131 2 112 57 ON ON ON ON 135 16 56 109 ON ON ON ON 142 2 54 88 ON ON ON ON ON 143 59 93 33 ON ON ON ON 144 110 61 2 ON ON ON ON ON 146 31 67 57 ON ON ON ON ON 148 131 52 92 ON ON ON ON ON ON 152 110 61 13 AUDIBLE SIGNALING DEVICES

PRODUCTS AUDIBLE SIGNALING DEVICES CONNECTION DIAGRAM X2 -L -L +N +N C1 C2 C1 C2 electrical connection and tone selection through external control of C1 and C2 operating voltage connection N - L + AC: DC: DC + - S2 S2 (by-passing the reverse polarity protection diode) with reverse polarity protection (factory setting) without reverse polarity protection + - AC S3 S1 volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S3 tone selection switch S1 (selection of the polarity of the control voltage for C1 and C2) factory setting + CONFORMITY TO STANDARDS The acoustic parameters conform to the European standard DIN EN ISO 7731: Ergonomic alarms for public areas and workplaces acoustic alarms. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 08