Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Similar documents
Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Protec. Protec Algo-Tec TM 6400 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Fire Detection - Addressable

Protec Algo-Tec Protec Algo-Tec 6400 ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE FIRE CONTROL SYSTEM. Protec Fire Detection plc

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

System 800 Addressable Fire Detection & Alarm System

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

PROPOINTPLUS ASPIRATING SMOKE DETECTION SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Installation, Operating and Maintenance Manual

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

The supplier and installer of the system should be approved by the local civil defence authority.

Excel-EN Conventional Fire Control Panel

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

MINERVA MZX125 Digital Addressable Fire Detection System

Xenex Conventional Fire Detection & Alarm System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Intelligent Security & Fire Ltd

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

The EN54 Part 2, 4 and 13 Fire System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

The EN54 Part 2 & 4 Fire System

Solution F2. Fire Alarm Control Panels one step ahead.

MINERVA MZX125. Digital Addressable Fire Detection System

Saxon Range 1-8 Zone Convertional Control Panels

Conventional Fire Detection

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

user manual Document No , Revision 03 November 2015

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

ZXSe Range Data Sheet

HERCULES 6 GRAPHICS SYSTEM

Addressable and Conventional Fire Protection

intelligent fire alarm ID60series panels

The new detector from Rafiki

ID50series. intelligent fire alarm panels

DS7400Xi Addressable Control/ Communicator

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

The EN54 Part 2 and 4 Fire System

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Sita200plus. 200detectors. Single loop analogue addressable System

Intelligent Security & Fire Ltd

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Product Data Sheet. Remote Terminals. Features:

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Wireless Fire & Security Solutions. Fire Product Showcase

Document No Issue 4 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

ID3000 intelligent. fire alarm panel

Intelligent Security & Fire Ltd

XP95 Sounder VAD Base

Conventional Fire Alarm System 2014 V1.2

HART XL High Sensitivity Smoke Detection

Control Panel Engineering and Commissioning Instructions

Analogue addressable devices

Touch Screen 1 loop Addressable Fire Alarm Panel

ID3000 intelligent. fire alarm panel

An introduction to... Sigma

Conventional Leaflets

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

CODESEC FIRE ALARM SYSTEMS. security technologies

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

EFBW series - BiWire Ultra control panel

Intelligent addressable fire alarm control panel

Security Alarm Systems

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

4 wire conventional alarm system

Intelligent Security & Fire Ltd

Intelligent Addressable Fire Alarm System

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Vigilant MX4428 Fire Alarm System

MINERVA MX. 800 Series Ancillary Equipment

Advanced FireAlarm Panel 1-4Loop

ACP10 & ACP50 Security Systems

Fire control panels FC726 FC726-XA

Application, Installation, Operation & Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Fire Signalling. Signalling Solutions

HART XL High Sensitivity Smoke Detection

Transcription:

Protec Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

Fire Detection - Addressable Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM Cost Effective Single Panel High Capacity - 192 Addresses Algo-Tec TM 6000PLUS Protocol Surface and Recessed Mounting Easy to Install Reduced False Alarms Enhanced Performance On Site Flexibility Designed to EN 54-2 & 4 Open Protocol System Features The Protec Algo-Tec TM 6100 is an interactive digital addressable fire detection and alarm system ideally suited for small and medium sized buildings such as shops, hotels and offices. The control panel is designed and manufactured by Protec to comply with EN 54-2 & 4. The control panel is suitable for surface or recessed mounting with a moulded polycarbonate enclosure finished in storm grey. The 6100 control panel is equipped with a high capacity Algo-Tec TM digital addressable data loop, with up to 192 addresses. In addition to the Algo-Tec TM 6000PLUS sensors, interfaces and manual call points the loop can also support loop powered SOUNDERS, VISUAL DEVICES and OPTICAL BEAM DETECTORS. Additionally a 6300 Powered Repeat Display can be connected directly to this loop, resulting in reduced cabling requirements, simplified installation and associated cost savings. Alarms In addition to loop powered sounders and Visual Alarm Devices (VAD s), 2 fully monitored alarm outputs are provided at the panel for alternative wiring arrangements. Auxiliary Contacts One set of global fire, and one set of fault changeover contacts. Controls and Display All the functions of the modern styled Control Panel are accessed by entering the user access code. The controls are SILENCE, SOUND S, RESET and ACCEPT plus navigation push buttons to enable access to the user menu facilities. The control panel display consists of a 4x20 character liquid crystal display, twin common fire LED indicators, 16 separate zonal fire LED s, power on, pre-alarm, system fault, common fault, test and disablement LEDs. Liquid Crystal Display The 80 character liquid crystal display will under normal quiescent conditions display the current date and time with the option to also display a 40-character user s message such as site name. In an alarm or fault condition the LCD will display the device, address and zone number and up to 20 characters of user definable location text, programmable on site using Protec 6100 windows based software. Device Location Text Windows based text software is supplied free of charge to our clients to enable you to enter the location text on to the disk supplied and hand to our commissioning engineer for loading into the panel during commissioning. This simple process allows you more flexibility enabling you to make any last minute changes and speed up the entire process. Power Supply The 6100 control panel is supplied with an integral 1A dc switch mode charger and accommodates two 12V 3.3 Ah sealed lead acid battery. On Site Programming The Protec Algo-Tec 6100 system is on site programmable. All of the commissioning configuration data can be entered and/or backed up using the Protec 6100 windows based programming software via a PC. This feature enables the system to be re-configured and checked prior to attending site simplifying commissioning works on site, enabling text amendments to be carried out whilst on site and providing an invaluable remote backup should the need arise.

Devices The Protec Algo-Tec 6000PLUS protocol utilises FAST addressing (Firmware Addressed Secure Technology). Every FAST device is manufactured with a unique serial number. FAST addressing ELIMINATES troublesome and time consuming address cards and DIL switching whilst being far more secure than soft addressing. The Protec Algo-Tec 6000PLUS sensor range has been developed to incorporate advanced fire sensing technology, electronic sounders, high intensity visual alarm and speech enhanced talking sounder capability, all integrated within the sensor head and powered from the loop. Plant shutdown interface 6000/MICCO Heavy duty plant shutdown signal (Rated at 240V 5A) 6300 repeater LOOP 1 Sprinkler delay interface 6000/MICCO Plant shutdown output (Rated at 240V 5A) Typical Sensor Variants 6000PLUS/OPHT/S = c/w Sounder 6000PLUS/OPHT/VAD = c/w Visual Alarm Device 6000PLUS/OPHT/S VAD = c/w Sounder and Visual Alarm Device 6000PLUS/OPHT/TS = c/w Talking Sounder 6000PLUS/OPHT/TS VAD = c/w Talking Sounder and Visual Alarm Device Zone circuit Alarm circuit Zone circuit Alarm circuit 6000PLUS/HT FAST TM Interactive Heat Sensor - Interactive addressable heat sensor with low thermal mass thermistor, giving fast response to temperature increases. Other Heat Sensor variants include: 6000PLUS/HT/S, 6000PLUS/HT/SVAD 6000PLUS/HT/TSVAD 6000/LPZA powered zone alarm interface 6000/LCM Local Control Module 6000PLUS/OP FAST TM Interactive Optical Smoke Sensor - Interactive addressable high performance optical smoke sensor provide efficient reliable detection using the light scatter sensing principle with rapid response to a fire signal. Other Optical Sensor variants include: 6000PLUS/OP/S Single 2 wire loop cable 6000PLUS/OPHT FAST TM Interactive Optical Heat Sensor - Interactive addressable high performance optical smoke and heat multi-sensor. Other Optical Heat Sensor variants include: 6000PLUS/OPHT/S, 6000PLUS/OPHT/VAD, 6000PLUS/OPHT/SVAD, 6000PLUS/OPHT/TS, 6000PLUS/OPHT/TSVAD } 2 monitored alarm outputs 6000PLUS/OPHTCO FAST TM Interactive Optical Heat CO Sensor - Interactive addressable high performance optical smoke heat and carbon monoxide multi-sensor. Other Optical Heat CO Sensor variants include: 6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/VAD, 6000PLUS/OPHTCO/SVAD, 6000PLUS/OPHTCO/ TSVAD 6000PLUS/BASE Low Profile Common Mounting Base - Compatible with the above range of Algo-Tec TM 6000PLUS Sensors. Monitored fire station output 1 Auxiliary fire c/o contact 1 Auxiliary fault c/o contact 24V Aux. output Bomb alert/class change input Remote alarm input Mains ac supply 6000PLUS/FFBASE Fast Fixed Base - Fast fixed recessed base is designed to recess the sensor into a false ceiling to give a lower profile view of the sensor. KEY: Heat Sensor Local Control Module 6300/LOOP/LCD Repeater - Connected directly to the local data loop and takes up just one address. The 1 x 40 character LCD Display provides clear text location of fire and fault events. Optical Smoke and Heat Sensor Optical Smoke, Heat and CO Sensor Duct Probe Unit c/w Smoke Sensor Monitored Input CC Output Interface Electronic Sounder Electronic Sounder VAD 6000/MCP FAST TM Addressable Manual Call Point - Key operated test facility, a loop short circuit isolator is incorporated. Manual Call Point Beam Detector Visual Alarm Device (VAD) 6300 LCD Display Powered Zone Alarm Interface

Total Load in Alarm (ma) Total Load in Alarm (ma) Guide to loop cable conductor sizing for the Protec 6100 system. 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Length (Metres) 500 550 600 650 700 750 800 850 900 950 1000 Length (Metres) 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 The conductor size required as follows: 1.0mm 2 1.5mm 2 2.5mm 2 MAXIMUM LOOP RESISTANCE 16 OHMS PER CONDUCTOR 6000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Single pipe air sampling unit for air speeds from 0.5 to 20m per sec. supplied with 6000PLUS/BASE suitable for use with 6000PLUS/OP FAST TM interactive optical smoke sensor. 6000/FIREBEAM 6000/SSR FAST TM Addressable Powered Beam Detector - Combined transmitter/receiver unit and separate low level controller. With a beam range of 5-100 metres. 6000/VAD/W/RED FAST TM Addressable Powered High Intensity VAD - Approved to EN54-23 the wall mounted VAD has a unique lens that distributes the white light in a cuboid pattern to achieve 7.5m x 7.5m coverage @ 2.4m high. 6000/VAD/C/RED 6000/SSR/VAD 6000PLUS/TSR2 6000/FIU FAST TM Addressable Powered High Output Electronic Sounder - utilises a Piezo driver unit to enable high sound output and very low current consumption. FAST TM Addressable Powered High Intensity VAD - Approved to EN54-23 the ceiling mounted VAD has a unique lens that distributes the white light in a cylindrical pattern to achieve 7.5m dia coverage @ 3m high. FAST TM Addressable Powered High Output Electronic Sounder with VAD - Approved to EN54-3, 17 & 23 the wall mounted combined sounder/ VAD has a sound output of 100dB(A) @ 1m plus VAD light output of 7m x 7m coverage @ 2.4m high. FAST TM Addressable Powered Talking Sounder - The 6000PLUS/TSR2 voice enhanced talking sounder is available with seven voice messages plus bell sound in addition to the three fire alarm tones compatible with the Protec range of electronic sounders. Flush Mounted Short Circuit Isolator Unit - To isolate a short circuit fault on either the incoming or outgoing loop cables. Suitable for a 30mm deep electrical mounting box. Fire Detection - Addressable Table detailing the loop standby and alarm load for typical Algo-tec 6000 devices. Product Description No of Addresses Standby Load ma Alarm Load ma 6000/MCP Manual Call Point 1 0.45 0.85 6000/FIREBEAM Beam 1 3.65 7 6000PLUS/HT Heat Sensor 1 0.2 0.2 6000PLUS/HT/S Heat Sensor c/w Sounder 1 0.4 5.4 6000PLUS/OPHT Optical Smoke and Heat Sensor 1 0.2 0.2 6000PLUS/OPHT/S 6000PLUS/OPHT/SVAD 6000PLUS/OPHT/TSVAD Optical Smoke and Heat Sensor c/w Sounder Optical Smoke and Heat Sensor c/w Sounder and Visual Alarm Device Optical Smoke and Heat Sensor c/w Talking Sounder and Visual Alarm Device 1 0.4 5.4 1 0.55 24 1 0.55 25 6000PLUS/OPHTCO Optical Smoke, Heat, and CO Sensor 1 0.45 0.45 6000PLUS/OPHTCO/S Optical Smoke, Heat, and CO Sensor c/w Sounder 1 0.45 5.45 6000/VAD/W Visual Alarm Device 1 0.8 19 6000/SSR Sounder 1 0.7 5 6000/SSR/VAD Sounder Visual Alarm Device 1 0.7 24 6000/LCM Local Control Module 1 0.7 5 6000/MICCO Monitored Input CC Output 1 0.55 5 6000/LPZA FAST TM Addressable Flush Mounted Powered Zone Alarm Interface Unit - With a monitored detection circuit suitable for use with Protec 3000 series detection devices. Line continuity maintained. Monitored alarm output circuit rated at 24Vdc 50mA max. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is included. 6000/LCM FAST TM Addressable Flush Mounted Local Control Module - Allows easy integration of Protec addressable fire detection systems into houses of multiple occupany and offers novel features to reduce false alarms. The interface drives a zone of 3000 series detection devices and provides a supply to a local alarm circuit. 6000/MICCO FAST TM Addressable Flush Mounted Powered Monitored Input, Clean Contact Output Interface Unit - With a monitored input circuit suitable for use with simple switch devices and the output is a clean changeover contact 5amp rated at 240V ac. A link can be cut to provide a 7-second delay to the input. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is incorporated. Multi-way Input/Output Interfaces - A range of 16 way input/output interfaces are available with monitored alarm outputs or clean changeover contacts. All interfaces are FAST TM addressable. Note: The following Parameters should be observed 1) The total number of addressable devices should not exceed 192 per loop. 2) Add 20mA to total loop alarm load to allow for fire indicator LED s on devices 3) The total loop alarm load should not exceed 600mA per loop.

CAUTION Algo-Tec 6000PLUS Interactive Decision Making Algorithms - Typical Applications Office Mode (High Performance) Computer Fire Day/Night Mode Offices DISCRIMINATING ALGORITHM Cigarette Smoke Bin Fire Factory Loading Bay Clean Mode (Extra High Performance) Printer Paper Fire Bedroom Mode Computer Room Fire Chemical Fire DISCRIMINATING ALGORITHM Steam From Bathroom The Protec Algo-Tec 6100 Interactive Digital Addressable System unwrapped: The Protec Algo-Tec TM 6000PLUS protocol developed by Protec s in-house Research and Development team is utilised by the Protec Algo-Tec TM 6100 interactive digital addressable fire control systems. Immunity to false alarms, more responsive fire detection, and ease of use has all been achieved to develop one of the most reliable systems available. Protec Algo-Tec 6000PLUS The name Algo-Tec TM is a derivative of Protec algorithms. Algorithms are logical mathematical procedures for solving problems. Protec have developed fire detection algorithms coupled with fuzzy logic specifically designed to reduce unwanted fire alarms and to enhance the sensitivity of the system to true fire phenomenon. The Algo-Tec TM algorithms are exclusively utilised by the Protec Algo-Tec TM 6400, 6300 and 6100 Interactive Digital Addressable Fire Control Systems. Fire Detection - Addressable Day Mode: Office mode (high performance) Offices Night Mode: Clean mode (Extra high performance) Day Mode: Heat detection only (6000PLUS/OPHT) Factory Loading Bay Night Mode: Smoke & Heat detection DISCRIMINATING ALGORITHM Aerosols in Bedroom Smoldering Fire NOTE: The above examples give an indication of system reaction to intermittent contaminants and typical fire sources in a correctly designed BS5839 system. They by no means detail the full complexity of the systems decision making algorithms. Examples are for 6000PLUS/OPHT. Interactive Algo-Tec TM evaluates the data of each fire sensor and is able to learn from the information received. This may simply be to recognise that a sensor is becoming contaminated or in a dirty environment and to automatically increase the alarm threshold to compensate for the background levels (Threshold Compensation). More complex Algo-Tec TM functions include the ability to discriminate between certain fire and non-fire conditions, filtering out certain environmental stimuli, and increasing the sensitivity of a sensor when an increase in temperature is detected. The net effect of the interaction between the sensors and the Algo-Tec TM decision making is enhanced performance, through immunity to false alarms and more responsive fire detection. 6300 LCD Display The 6300/LOOP/LCD can be connected directly to the local Algo-Tec TM digital addressable data loop and takes up just one address. The facia displays power, fire, fault, disablement and more alarms. Fire and fault events are displayed on the 2 x 40 character LCD display and automatically scroll. A backlight ensures that the events can be read in all lighting situations. Fire events have highest priority and inhibit the display of fault events. A new event initiates the internal buzzer and a mute button allows the internal buzzer to be muted. standby/alarm load 60mA. Dimensions (mm): 360(W) x 215(H) x 47(D) Digital Addressable The data communication between the sensors and the control equipment is Digital. The Algo-Tec TM protocol utilised by the 6000PLUS system enables high levels of data to be transferred, providing far more detailed information than was previously achievable with analogue addressable systems. It should however be noted that many analogue addressable systems use digital communication but do not transfer the high levels of data associated with the Algo-Tec TM protocol. Speed, stability, excellent EMC and security all serve to enhance the Algo-Tec TM Digital signalling. Why go analogue addressable when you can now choose Algo-Tec TM Digital Addressable.

Fire Detection - Addressable Technical Specification 6100 Control Panel Complies with EN54-2 & 4 Model:- Specification:-. Rated Voltage Rated Frequency Rated Current Working Voltage Temperature Range Maximum Humidity IP Rating Battery Type Standby Load (Mains Fail Condition) Maximum Alarm Load (Mains Fail Condition) 6100 - Single. Mains 100 to 240V ac rms. KM575025 0086-CPD-575026 50 to 60Hz. BS EN54-2:1997 600mA rms. BS EN54-4:1998 21.5-29V dc. 0-40 C. 85% Non-condensing. IP30. 2 x 12V 3.3Ah sealed lead acid. 22mA. 56mA panel, 600mA loop, 200mA conventional alarms (100mA per alarm output), 150mA auxillary 24V output, 20mA fire-link. Display Backlit liquid crystal display 4 lines of 20 characters. Digital Addressable s 1 loop, with 192 address capacity. Algo-Tec 6000PLUS Protocol. Total Load 600mA including all loop connected devices. Zones 32 Zones, 16 with LED indication, plus general fire indicator. Integral Charger 1A dc switch mode, temperature compensated. Integral Battery 2 x 12V 3.3Ah sealed lead acid. Alarm Outputs 2 monitored conventional sounder circuits (100mA per output maximum). Up to 192 alarm outputs using loop output devices. Global Fire Outputs 1 set of non-monitored changeover contacts (1A @ 24V dc) operating on any fire. Alarm Load 600mA loop, 100mA per conventional alarm output. Fault Monitoring Fully fault monitored to EN 54-2 & 4. Fault Output Single pole changeover contacts (1A rated @ 24V dc). Auxiliary Output Supply 24V dc fused at 150mA. Common Fire Output (fire station) 24V dc fully monitored output (requires end of line module SF4165759). Communications Interface USB 2.0 (Type A male to Type B male connection lead required, 2 metres maximum length). Dimensions (mm) 228(W) x 345(H) x 111(D). Weight 1.5kg (excluding batteries). Applicable Standards EN 54-2 : 1997 + A1 : 2006. EN 54-4 : 1998 + A1 + A2. Programmability 32 Input Groups First 31 groups are available for detection zones, group 32 is reserved for Sound Alarms push button. 32 Output Groups Each output group can have a delay programmed (5 seconds to 10 minutes). Each output group can be set as Alarm or Control type. Non-Latching addresses may be programmed to be non-latching. Coincidence To EN 54-2 Type C dependency. Detection Sensitivities Each detector may have one of two sensitivities programmed. Sounder Volume Each loop sounder may be programmed to be low, medium or high volume. Day/Night Time The panel may be programmed into two time zones to run different sensitivities for each detector. Sounder Pulsing Time The sounder on and off times may be programmed from 0.5 sec to 128 sec in 0.5 second increments. Talking Sounder Synchronisation Time 1 sec to 120 sec in 1 second increments. Fire Link Delay Time 5 seconds to 10 minutes in 5 second increments. Walk Test Time 1 sec to 255 sec in 1 second increments. Windows Software Suite Proprietary software suite designed specifically for the 6100. Allows text editing, matrix configuration, setup of all panel parameters. Text Panel Text Device Address Text Zone Text Language Support 2 lines of 20 character panel text. Displayed when the system is normal. 20 characters of device address text. 20 characters of zone text. The 6100 supports multiple languages. Protec Protec: Scotland Tel: 0845 456 5390 Fax: 0845 456 5391 Protec: North East Tel: 0845 456 5396 Fax: 0845 456 5397 Protec: Yorkshire Tel: 0845 456 5388 Fax: 0845 456 5389 Protec: Midlands Tel: 0845 456 5398 Fax: 0845 456 5399 Protec: South East Tel: 0845 456 5394 Fax: 0845 456 5395 Protec: South West Tel: 0845 456 5392 Fax: 0845 456 5393 Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice Protec Fire Detection Plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT Tel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.uk MED1573 Issue 3 N 92-168-76