Technical Support Bulletin Nr. 3 Heating

Similar documents
Technical Support Bulletin No. 23 Try ColdFace!

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Bottle cooler controllers Solutions for static, ventilated and open coolers

CRIMSON & CRIMSON MAX

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

User Manual Ichill 200 L/D (Firmware version 1.7)

CT EN rel. 10/09 Copyright Eliwell Controls s.r.l All rights reserved

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

ECH 985. Electronic controller for heat pumps used in residential hot water application

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Air to water Heat Pump System

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

ST 53.1 User s manual

PRODUCT RANGE HEAT PUMPS 2012

GAS ABSORPTION HEAT PUMP

PARAGON Commercial Refrigeration Controls

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Technical description. Atec.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

REMOTE CONTROL FOR CHILLER MYCHILLER

Temperature - Humidity - Pressure

INSTALLATION AND USER MANUAL

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Outdoor Reset Control Theory FULL versus PARTIAL reset

AWR MTD2 XE. Versions

EWCM 900/S rel. 5/2000 ing

IC200L Series User manual

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

SERVICE MANUAL REFRIGERATION

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

ER52 - Evaporator Controller

SERVICE MANUAL REFRIGERATION

Regulation EASY CLIMA VERSION 1.6 TECHNICAL MANUAL

ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Operating Functions Temperature Parameters

Refrigerated air dryers

Dixell Installing and Operating Instructions release 7.0

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

IPC108D - IPC108E (V.2.0)

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

EasyTech.One Temperature Controller for Pellet Burner

XC1008D -XC1011D- XC1015D and VGC810

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

EWDR 984. SIGNAL LED The status of the external devices, functions and controllers is described by the device LEDs.

HT V2 HT Split

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

INSTRUCTION FOR THE USER THC V E OIL BLU

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

solar thermic systems

Natural geothermal energy

OPERATING INSTRUCTIONS

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

High efficiency air to water Heat pumps LZT series

LZT High efficiency air to water heat pumps with E.V.I. compressors

Geothermal Heat Pump Systems

Installer Manual KNX Touchscreen Thermostat

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Agent - Manufacturer of Boreal geothermal heat pumps

N M AirControl AHU. Control manual

REA22 Room Temperature Controller

Air-cooled heat pump USER MANUAL HBI IHBIFY _01

TIREE FAN COIL CONTROLLER - T6580

T6580 FAN COIL CONTROLLER

INSTALLATION AND USER MANUAL

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

EWHT800LX. Controllers for cold rooms and curing rooms for on-board installation

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

ACCUMULATION OF EUROPEAN CLASS

FREQUENTLY ASKED QUESTIONS

Sweden s leading air source heat pump

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

> > > Heat pump systems. Water Chillers. Dehumidifiers

Heat Pumps. ground-to-water models air-to-water models. Energy-saving solutions

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

GEOTHERMAL DESIGN GUIDE

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

USERS MANUAL FOR GAS BOILERS

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Air to water Heat Pump System

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

INSTALLATION AND USER MANUAL

LZA High efficiency air to water heat pumps with HP compressor

Water and ground source heat pumps 61WG kw. Heating

Transcription:

Technical Support Bulletin Nr. 3 Heating Contents! Introduction 1! Heating Traditional applications for Eliwell products 1! Space heating: 2! Heat pumps 2! Types of heat pump machine 3! Water to water machines 4! Geothermal heat pump 4! Applications for heat pumps 4! ECH985 5! ECH985 applications 6! IC974 7! IC974 applications 7! IC915D 7! IC915D applications 9! Appendix: solar panel heating 9! Introduction The aim of this bulletin is to discuss new products for space heating (ECH 985, IC915D) and specific industrial applications (including food storage: IC974, ID915D). Heating Traditional applications for Eliwell products In the same way as refrigeration and air conditioning processes, heating also requires temperature control. This leads to specific requirements for inputs, outputs and control methods:! probes that are suitable, with regard to material and type of sensor, for high temperatures (e.g. thermocouples and Pt100s).! outputs for different uses: switching on of electric heaters, enabling of combustion systems, valve control (water, oil), also with modulating signal, and control of the compressor (heat pump).! control based on one or more steps with on-off control but also of the proportional-integral- (derivative) type with different types of actuation (modulating signal, on-off output with duty cycle...). Some Eliwell controllers have been used and valued for some time because of their more straightforward control with one or two steps (for example: IC912 and 915, with their EWPC predecessors). These controls cover several different applications:! ovens (for cooking food and other uses);! moulding or material processing machinery;! treatment of fluids in industrial processes;! thermostatic control of laboratory equipment and incubators;! control of cooking of food;! heating of rooms for seasoning, drying, ripening... The range of controllers in question can be defined as universal since, in addition to what has already been stated, they can be used for the control of very low temperatures (with Pt100 input), humidity, (V-I instruments with EWHS probes), pressure, etc. Technical Support- Bulletin No. 3 Heating ENG - 1/11

Another line of development concerns the control of ambient air that is usually (but not always) linked to air conditioning systems; this is achieved using more complex controllers (e.g.: ECHs, ERTs) that are capable of integrating different controls with a high number of inputs and outputs. Space heating: this is obtained using:! gas or other fuel burners: with intuitive operating, widely used and easy to control; they use fossil fuels with obvious environmental implications (renewability, emissions...).! heat pumps (hereon referred to as HP): consisting of refrigerators that usually operate with a compression cycle; in this case ( reverse cycle) the cool exchange occurs towards the outside and heat exchange towards the ambient under special conditions; the cycle may or may not allow reversal: the first case is more frequent and also allows summer cooling (reversible HP with 4-way valve, for example, on refrigerant); the second case is however relevant to climates that do not require cooling. In the compression cycle, electrical energy is usually used (1 electrical kw can be used to exchange 2.5-5 thermal kw) and is affected by the quality of the external exchange; the different options for the type of external exchange and carrier fluids will be examined below.! electric heaters: with intuitive operating; not widely used except when integrated with other methods (unlike the previous case, 1 electrical kw produces 1 thermal kw). the above methods can direct the heat in the ambient air:! directly (air)! indirectly (water as carrier fluid: hydronic systems). there is also another source of energy used for heating:! solar energy exploited using water circuits (photovoltaic technology is not dealt with here); the increasing spread of solar energy systems is encouraged with financial incentives in several countries due to their low running costs and environmental compatibility. Hydronic systems can easily integrate several modes among those listed in a single system; the control must therefore be able to handle the most convenient mode in terms of efficiency, comfort, etc. For the above cases, accessory loads are also used (fan or water pump) with relative protections (on air filter, on motor thermal as well as flow switch, anti-freeze...) If heat has to be distributed to several areas, each one with its own specific temperature and operating characteristics (e.g. valve, fan or damper...), several controllers are installed: one per area with simple control and one for the central heating unit (essential in hydronic systems). A typical example in hydronic systems (with fan coils) consists of several FanCoilBasic controllers or similar and an ECH (200 or 400) controller. Heat pumps Let s take a detailed look at some concepts:! energy efficiency: the relationship between the electrical and thermal power is explained by the fact that the HP simply moves the heat from one spot to another.! The subtracted heat can be compensated for in different ways by solar (air, soil...) radiation or industrial processes (low temperature energy).! the HP usually uses electricity, the cost of which varies considerably from country to country; we must also consider the efficiency and environmental impact of the electrical energy that depends on the sources used. Moreover, the energy efficiency of the HP may be affected in a number of ways by the climate since heat exchange with outside is necessary. HP consumption/performance are affected by:! heating requirements and seasonal variations,! exchange temperature, in particular: Technical Support- Bulletin Nr. 3 Heating ENG - 2/11

o the exchange of heat inside depends on the relative carrier fluid (air or water) and the method of distribution (e.g. fan-coil, floor system...) o the exchange of heat outside is also linked to the medium that the heat is extracted from as will be explained below; this medium may undergo considerable temperature swings,! consumption of auxiliary equipment (pumps, fans...) Types of heat pump machine! Compression cycle (mechanical energy is used that acts on the refrigerant fluid and latent heat of evaporation/condensation) fig. 1 1 kw compressor condenser evaporator 4 kw 3 kw Water (air) to ambient TEV External fluid - water (air) o (other less common methods: gas absorption cycle similar to above but without phase transition in which thermal energy and liquid solution are used...)! the mechanical energy supplied to the compressor comes from the electric motor (energy efficiency is therefore based on the electrical absorption of the machine) o (other less common methods: gas-powered combustion engine...) the most common cases concerning the possibility of changing operating mode (summer, winter), exchange fluids and relative controllers are listed below:! change of mode allowed (reversible HP) o temperature control: air, outside: air --> ERT; reversal with 4-way valve (on refrigerant), o temperature control: water, outside: air --> ECH; reversal as above # recovery in summer mode is sometimes used (partial use of machine as water to water) o temperature control: water, outside: water --> ECH; reversal with: # 4-way valve (on refrigerant circuit), # 3-way valve (on water circuit),! change of mode not allowed (non-reversible HP) o temperature control: air, outside: air --> ERT, o temperature control: water, outside: air --> ECH, o temperature control: water, outside: water --> ECH (also 985).! Defrosting, typical of the winter mode and with the exchange of external air, enables the HP to operate in harsh conditions (cold and humid external air); however, frequent defrosting Technical Support- Bulletin Nr. 3 Heating ENG - 3/11

reduces the HP s energy performance and makes it uneconomical; this can be overcome with alternative forms of heating (boiler) handled by the controller. Water to water machines Another heat exchange medium can be used as well as external air such as water to water machines (closed or open circuit). Obviously, these do not require fan control; in summer mode, heat recovery is possible (useful in hotel installations...) and in winter mode, they do not require defrost control (restrictions for antifreeze diagnostics remain however). the external water circuit can then exchange with:! industrial flows,! the earth (geothermal machines),! groundwater and basin water (allowed in some countries) The use of water in an open circuit is typical of the summer mode with evaporative condensers. Geothermal heat pump Geothermal machines are interesting especially in winter mode; the earth, with which low temperature heat is exchanged, is not subject to temperature changes and this is evident the further underground you go; Exchange usually takes place through a pipe buried underground; the water in this absorbs heat from the earth thus balancing the evaporator load. Here is a brief summary of the advantages and disadvantages of this technology that is very common in residential applications in America/Northern Europe.! use of the HP in all conditions without the energy burden of defrosting; the COP (coefficient of performance) for the entire season is still advantageous (even if the heat exchange between the pipe and the earth is less beneficial than with other types)! higher system costs must be considered (e.g. excavation work) fig. 2 compressor -10 C condenser evaporator water to ambient TEV 0...+5 C Applications for heat pumps In addition to residential use (space heating and domestic water) there are other possibilities:! buildings for services / commercial sector (space heating and water),! thermostatic control of process fluids in industry,! other industrial processes (heat for drying, steam production, distillation...),! heating of greenhouses. Technical Support- Bulletin Nr. 3 Heating ENG - 4/11

ECH985 If we consider a non-reversible, water to water HP with auxiliary heating (fig. 3), this can be controlled using ECH200-400s and the new ECH985 that features a weekly clock and straightforward configuration and wiring. Main characteristics! 24Vac/dc power supply,! 3 NTC analogue inputs,! 2 digital inputs (clean contact),! 4 outputs on relay,! all connections on screw connector,! same casing, front keypad (IP65) as IC/ID family,! same keys and display with same operating as IC/ID family,! serial connector (5 pole TTL) for configuration tools and CopyCard,! buzzers and relays can be used for alarm signalling,! the compressor, pump and auxiliary heating operating times are calculated (with 100 hour resolution and a reset option),! the presence of an onboard clock is very important and permits daily or weekly programming of set point modification (the start-up time and duration of status are established). fig. 3 R compressor To users (Loads) HP R water condenser AI3 evaporator R heater AI2 tev / eev flow switch AI1! the instrument heats the water ( boiler probe temperature) with a heat pump cycle (compressor relay activated),! the compressor is controlled by the usual safety times and high pressure digital input diagnostics,! if alarms are present that inhibit the compressor, auxiliary heating is provided (e.g. electric heater or fuel system) that meets heating needs,! the auxiliary load is also controlled in specific time bands in order to observe a set point that is higher than the control set point; this set point is useful for removing microorganisms in the water (e.g. legionella), Technical Support- Bulletin Nr. 3 Heating ENG - 5/11

! there is also a relay for the water pump with relative diagnostic (flow switch) and timers for the control request,! in addition to the high pressure and flow switch alarms, the diagnostic controls errors in the three probes, anti-freeze protection (based on the evaporator temperature) and low temperature of the inlet water; depending on the type of alarm, the conditions for passing from automatic to manual reset or by-pass conditions or the enabling/disabling temperature threshold can be configured; it also controls the clock resetting alarm. ECH985 applications Other relevant applications include:! general two-step space heating one of which is preferential (more efficient); it can be linked to the economy set point (e.g. water temperature lower at nights and weekends),! integration between solar and traditional heating: solar energy can be established as a preferential source of energy and automatically excluded when the temperature of the solar panels is too low. (see fig. 4); the traditional source can consist of boilers, heaters... the considerations made concerning the economy set point set on a weekly basis remain valid, fig. 4 R on-off AI3 Solar panel Loads (AI2) flow switch R boiler AI1 R water pump! simultaneous control of cooling and heating (e.g. ambient air + swimming pool in summer...). Technical Support- Bulletin Nr. 3 Heating ENG - 6/11

IC974 This instrument combines the characteristics of the ID and IC ranges. The name of the product indicates that it includes ID974 (thermostat control, defrosting, fan...) and IC ( cool and warn control) functions. Let s take a detailed look at the IC974LX. Main characteristics! 24Vac/dc power supply! 2 analogue inputs configurable as NTC or PTC,! 1 digital input (clean contact),! 4 outputs on relay,! all connections on screw connector,! same IP65 front keypad, keys and display with same operating as IC/ID family,! serial connector (5 pole TTL) for CopyCard (Televis and Param Manager subject to availability),! the relays can be configured for: cooling, heating, defrosting, ventilation, auxiliary control and alarms (for typical applications, see below),! the digital input and three buttons can be configured for: defrosting, economy set point, auxiliary control, door switch, mode limitation (only heat or only cool is enabled); the single input can be configured as external alarm whereas the buttons can also be used for disabling control (stand-by),! two set points can be used that are separate or interlinked (e.g. for controlling two steps in the same mode) or only one set point (neutral zone); the economy set point is set separately for each set point,! the operating hours are counted ( heat or cool mode) and can be displayed and reset,! the diagnostic (controlled from a menu, relay, buzzer (if present), supervision system...) can be applied to the usual alarms (high/low temperature, door open...) as well as an external alarm that can be selected. IC974 applications! food storage in neutral zone (with heating, if necessary) at 0 C (with defrost request): useful in cold rooms (seasoning, ripening, storage; especially for food that is sensitive to temperature changes, unwanted freezing...); example of relay configuration: cool-heatdefrost-fan, or...-alarm,! thermostatic control plus alarm management (with particularly sensitive temperature alarms in cold rooms and industrial applications); examples: cool1-cool2-alarm, coolheat-alarm...! thermostat control (heat and/or cool) with consensus on the air outlet temperature (probe no. 2 / fan),! control of dual compressor machines (each one with its own set point and suitable protection delays); examples: cool1-cool2-defrost-fan,! flexible control of stored product (adjustment of set point with button or switch; temporary disabling of one of control modes...). IC915D This instrument is an advanced version of the IC915: in addition to the usual uses, specific controls can be enabled (parameter-enabled) so that two temperatures can be read, Probe no. 2 can therefore be used for the external air temperature or the outlet temperature. Let s take a detailed look at the IC915D LX. Main characteristics! power supply 230Vac (other voltages subject to availability),! 2 analogue inputs configurable as NTC or PTC,! 1 digital input (clean contact),! 2 outputs on relay, Technical Support- Bulletin Nr. 3 Heating ENG - 7/11

! all connections on screw connector,! same IP65 front key pad, keys, display as other ICs,! serial connector (5 pole TTL) for CopyCard (Televis and Param Manager subject to availability),! the relays can be configured for: cooling, heating, alarm, duty-cycle, auxiliary control, instrument status repetition (on-off) (for typical applications, see below),! the digital input and three buttons can be configured for: soft start (in heating mode), economy set point, auxiliary control, control disabled (stand-by), duty cycle activated; the single input can also be configured as an external alarm, Two set points can be used that are separate or interlinked (e.g. when controlling two steps in the same mode) or only one set point (neutral zone); the economy set point is set separately for each set point. The set point and start-up/shut-down temperatures of the load are linked to values set using the keyboard but also special conditions determined by the two probes; examples are illustrated below (for simplicity s sake, one-step heat control is considered). The three cases described are parameter-defined; the first is simple and applies to all IC models; with regard to the other two:! case 2 adopts a dynamically calculated value as control input with a keyboard-set set point fig. 5 (1-2-3) Probe 2 Probe 1 Probe 2 Probe 1 25 25 15 10K Set SP1= 30 df1= 2 ON at Pb1= 28 C or less OFF at 30 C or more Set SP1= 6 df1= 2 ON at Pb1-Pb2= 4K or less OFF at 6K or more Relay OFF Relay ON Case 1 Case 2 Probe 2 Probe 1 25 8 C SP1= 12, df1= 2 Set= 12+8=20 ON at Pb1= 18 C or less OFF at 20 C or more Technical Support- Bulletin Nr. 3 Heating ENG - 8/11 Relay OFF

! case 3 uses a dynamically calculated set point whereas the input value corresponds to probe no. 1; the actual set point (20 C in the example) may vary considerably because of variations on probe no. 2 (consider if it used as an external air probe): limits can therefore be imposed on the actual set point to obtain a fixed winter set point (when the external temperature is low), a fixed summer set point (external temperature is high) and a dynamic set point for intermediate external conditions.! The displayed value can be selected (usually probe no. 1 or probe no. 2 or the keyboard set point; the dynamic value in cases 2 and 3 is not displayed).! The diagnostic is the same as in other ICs and therefore has high/low temperature, digital input alarms... o the high/low temperature alarms can be detected on: probe 1 and/or probe 2 or the differential value ( probe 1 probe 2 ), irrespective of the selected control (refer to the three cases described above).! Cases 2 and 3 can also be controlled using the ECH products (200 and some 400s). IC915D applications! Case 2 differential thermostat control: o Assignment of a preset temperature rise to the fluid, in heating or cooling mode, with two steps or in neutral zone: useful in some industrial applications. o Enabling of circulation of a fluid (valve, pump control) if the difference between temperatures is sufficient: relevant to solar panel systems. o Control of destratifiers, agitators... especially in association with a duty-cycle configured relay. o By-pass valve control to optimize exchanger operating parameters (e.g. DTML).! Case 3 set point compensation: o ambient control with set point compensation (based on external temperature). Compensation is used for comfort (for forcing heating in winter and reaching full power more quickly, for example) or energy saving (reduce the demand in order to reduce the stress of a compressor system or reduce the external-internal thermal gradient, for example) o decalibration of set point in order to control the temperature gradient for the direction of flow (taking the cold room area or its contents, furthest from the air outlet point, as a reference point).! the above cases can be easily combined with the possibility of adjusting the set point ( economy set point) for example, at night or at the end of a season! use of alarm relay for abnormal inlet and/or outlet temperatures or poor performance of exchanger (due to fouling, insufficient flow...) Appendix: solar panel heating Financial incentives are currently being offered for this simple and relatively widely used technology. It is mainly used for heating domestic water. Technical Support- Bulletin Nr. 3 Heating ENG - 9/11

It consists of glass panels in which water circulates (mixed with antifreeze), a tank that usually has two exchange elements (one for the solar circuit and one for integration purposes), a circulation pump and other components (valves, expansion tank). Below reference is made to forced circulation systems (with circulation pump), that can also be used for space heating due to the increased capacity of the storage tank. The solar panels can be integrated with space heating, not exceeding 1/3 of requirements, and require the use of a radiant floor and a suitably sized tank with two separate temperatures. Another field of application concerns the heating of swimming pools. The control consists of comparing the temperature of the water in the tank with the solar liquid in the panels. If the temperature of the collectors is higher than the temperature of the tank, thermal energy is present and can be used; the circulation pump is switched on to force the solar liquid into a thermally insulated circuit until it reaches the cooling coil in the tank, If the energy supply from the solar circuit is not sufficient (bad weather) or consumption of hot water is high, the temperature in the upper part of the accumulator drops below a certain level. The auxiliary heating system must then be switched on. Technical Support- Bulletin Nr. 3 Heating ENG - 10/11

DISCLAIMER This document is the exclusive property of Eliwell and may not be reproduced or circulated unless expressly authorized by Eliwell. Although Eliwell has done everything possible to guarantee the accuracy of this document, it declines any responsibility for damage arising from its use. The same applies to any person or company involved in preparing and writing this document. Eliwell reserves the right to make changes or improvements at any time without notice. Eliwell & Controlli s.r.l. Via dell Industria, 15 Zona Industriale Paludi 32010 Pieve d Alpago (BL) ITALY Telephone +39 0437 986111 Facsimile +39 0437 989066 Internet http://www.eliwell.it Technical Customer Support: Telephone +39 0437 986300 Email: techsuppeliwell@invensys.com Invensys Controls Europe An Invensys Company Technical Support- Bulletin Nr. 3 Heating ENG - 11/11