GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Similar documents
Unilift KP, AP, SU/SV, SE & EF

LiqTec, V GRUNDFOS INSTRUCTIONS

Comfort Series Instant Hot Water System

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

Barnes Oil Sensor Switch

SIMPLEX WEATHERPROOF CONTROL PANELS

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

GRUNDFOS PLUMBING & HVAC PRODUCTS

We ve Got Panels Under Control.

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

TYPE LF/LC/LCV END SUCTION PUMPS

grundfos commercial building Grundfos Plumbing Solutions

Condensate Boiler Feed Water Make-Up

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

TYPE POS Oil Shield Sump Pump

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

Liquid Level Alarms & Controls

SECTION SANITARY SEWAGE PUMP STATIONS

TECHNICAL SPECIFICATION RESIDENTIAL GRINDER PUMP & BASIN.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

SECTION STEAM CONDENSATE PUMPS

Applications and Features

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

MORE DEMAND. than a pump. grundfos MAGNA3

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

CADDY CORPORATION. Utility Distribution Systems

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

product brochure Sump, Effluent and Sewage Controls

FEATURES. Other Fed-Flush Arrangements

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Power Supply Display Module PSDM. Installation and Operation Manual

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

1. VCOM Panel Installation Instructions EIN-CP-GEN Panel Wiring Diagram EDW-WD-DAX-137

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

Elevator Sump Kits and Components

D-Series Wetwell/Drywell Grinder Pump Station with Wired Level Sensor. Typical Specifications. Semi-Positive Displacement Type Grinder Pump Stations

Remote Alarm Panels Features

Steel Casework Acid Storage

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

GAS MONITOR Model Model

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

PANTHER. Condensate removal pump Installation and operating guide

CHAPTER 20 SERVICE EQUIPMENT

Submersible Pumps. Series BERS

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

PO Box 827 Hawley, MN (218) Fax (218)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Introduction to Flow Switch

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Arrow Hart hospital grade self-test GFCI receptacles

Mission Critical. Fuel Supply Systems

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

Elevator Sump Kits and Components

BC14G SERIES SERIAL NUMBERS WITH IW/IX/IZ/JG/JO REPLACEMENT PARTS LIST. EFFECTIVE March 20, 2006

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Electric Submersible Pumps

INTRODUCTION 09/'16 SUPSD 06/'15

SECTION LOW VOLTAGE LIGHTING CONTROLS

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

1. Read all instructions before proceeding with the installation. Improper installation may void warranties.

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Tubular Industrial Process

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

DIVISION- S. A. WATER. 2. American Flow Control Series Mueller #A-2360

ELP21LU3-LF-HLOL THREE CHANNEL

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Transcription:

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp, 16 A, Single Phase, 60 Hz. Model S2 rated at 230 VAC, 1 1 / 2 Hp, 16 A, Single Phase, 60 Hz. MOTOR-START CONTRACTOR: Rated for 24 FLA, Single Phase, 60 Hz. CURRENT LIMITING CIRCUIT BREAKER: 20 amp, OFF/ON switch, DIN rail mounting with thermal magnetic tripping characteristics. (Single Pole/120 V; Double Pole/240V) TOGGLE SWITCH: A SPDT HOA switch with a 10 A 115V/20A 230V motor rating. FUSE DISCONNECT: 5 amp (10,000 AIC) fuse with DIN rail mount. AUDIBLE ALARM: Panel mount with a minimum of 80 db sound pressure at 24 inches, warble tone sound. VISUAL ALARM: NEMA 4-rated, 7 / 8 -inch diameter, red lens, oil-tight with push-to-silence feature. AUDIO-ALARM SILENCE RELAY: 120 VAC, automatic reset, with DIN rail mount socket base. ALARM CIRCUIT: 120 VAC, wired separately from pump circuit, so that if the pump's internal overload switch or current-limiting circuit breaker is tripped the alarm system remains functional. ENCLOSURE: NEMA 4X-rated, fiberglass with hinged cover. Noncorroding. External mounting ears. PADLOCKABLE LATCH: Constructed of noncorroding stainless steel. Dimensional Drawing Standard Features LISTING: Underwriters Laboratories, UL 508 Listed. RATINGS: Model D1 rated up to 120 VAC, 1 Hp, 16 A, Single Phase, 60 Hz. Model D2 rated at 240 VAC, 1 1 / 2 Hp, 16 A, Single Phase, 60 Hz. MOTOR-START CONTRACTOR: Rated for 24 FLA, Single Phase, 60 Hz. CURRENT LIMITING CIRCUIT BREAKER: 20 amp, OFF/ON switch, DIN rail mounting with thermal magnetic tripping characteristics. (Single Pole/120 V; Double Pole/240V) TOGGLE SWITCH: A SPDT HOA switch with a 20 amp motor rating. FUSE DISCONNECT: 5 amp (10,000 AIC) fuse with DIN rail mount. DUPLEX ALTERNATOR: Cross wired style for independent lag pump function. AUDIBLE ALARM: Panel mount with a minimum of 80 db sound pressure at 24 inches, warble tone sound. VISUAL ALARM: NEMA 4-rated, 7 / 8 -inch diameter, red lens, oil-tight with push-to-silence feature. AUDIO-ALARM SILENCE RELAY: 120 VAC, automatic reset, with DIN rail mount socket base. ALARM CIRCUIT: Wired separately from pump circuit, so that if the pump's internal overload switch or current-limiting circuit breaker is tripped the alarm system remains functional. ENCLOSURE: NEMA 4X-rated, fiberglass with hinged cover. Noncorroding. External mounting ears. PADLOCKABLE LATCH: Constructed of noncorroding stainless steel. Sensor Floats Part Number Length 96001030 10' 96001031 20' Part Number Panel Type Model Phase Voltage Horsepower A B C D E 96001032 Simplex S1 1 115 1/ 3-1 9 5 / 16 11 5 / 16 11 1 / 2 10 3 / 4 5 1 / 2 96001040 Simplex S2 1 230 1/ 3-1 1 / 2 9 5 / 16 11 5 / 16 11 1 / 2 10 3 / 4 5 1 / 2 96001033 Duplex D1 1 115 1/ 3-1 13 5 / 16 15 5 / 16 15 1 / 2 14 3 / 4 8 1 / 4 96001041 Duplex D2 1 230 1/ 3-1 1 / 2 13 5 / 16 15 5 / 16 15 1 / 2 14 3 / 4 8 1 / 4

GRUNDFOS HIGH LEVEL TANK ALARMS Tank Alert I Tank Alert II Side View Specifications MODEL: Tank Alert I ALARM PANEL: The NEMA 1 metal panel features a red warning light, a green "power on" light, push-to-test alarm button, and a horn silence switch. ALARM FLOAT SWITCH: SJE's Pump Master Pump/Control Switch. SPLICE KIT: This UL Listed splice kit provides a safe means to make a strong, waterproof splice connection if additional cable length is required. VOLTAGE: Primary 120 V. 60 Hz. Secondary 12 V. 60 Hz. WATTS: 6.5 Watt Alarm Condition. ALARM SWITCH CONNECTION TERMINAL: 1 Amp, 24 V.A.C. FLOAT HOUSING: 3.38 in. diameter x 4.55 in. long, high impact resistant, non-corrosive PVC plastic with internal stabilizing weight. For use in liquids up to 140 F (60 C). MECHANICAL TILT SWITCH: Mechanically-activated, features heavyduty contacts. CABLE: 15 ft. long, 16 gauge, 2 conductor, SJOW-A water resistant, Neoprene. Specifications MODEL: Tank Alert II ALARM PANEL: The NEMA 4X non-corrosive, indoor-outdoor alarm panel features a large, red light, specially designed non-corrosive horn, silence switch (with automatic reset feature) and alarm test switch. Thermoplastic enclosure. ALARM FLOAT: SJE's Pump Master Pump/Control Switch. VOLTAGE: 120 V.A.C. NOTE: Power to the alarm must be 120 V.A.C. only. WATTS: 40 watts max. (alarm condition). AUXILIARY ALARM CONTACTS: 5 Amps, 120 V.A.C. FLOAT HOUSING: 3.38 in. diameter x 4.55 in. long, high impact resistant, non-corrosive PVC plastic for use in liquids up to 140 F (60 C). MECHANICAL TILT SWITCH: Mechanically-activated, features heavyduty contacts. CABLE: 20 ft. long, 16 gauge, 2 conductor, SJOW-A water resistant, Neoprene. Part Number Type A B C D E 96001042 Tank Alert I 6" 4" 2 1 /2" 96001043 Tank Alert II 4" 7 1 /4" 6 3 /4" 10" 5 1 /4"

GRUNDFOS BASINS Ejector Basin/Polyethylene Ejector Basin/Fiberglass * see note 1. Polyethylene Basin Fiberglass Basin *1. 18" and 24" Basin provided with 4" Adapt-A-Flex Fitting. 2. Fiberglass Basins require that a hole be cut for inlet fitting. See Hubs and Fittings (page 4) for proper hole sizing. Part Size Wall Materials of Number Type Diameter x Depth Capacity Weight Thickness A B C D E Construction 96001004 Ejector Basin 18" x 30" 30 gallons 10 1 /2 lbs. 3 /16" 30" 22" 18 3 /8" 18" 10 1 /2" Polyethylene 96001005 Ejector Basin 24" x 36" 71 gallons 26 lbs. 1 /4" 36" 29 1 /2" 24 1 /2" 24" 10 1 /2" Polyethylene 96001006 Ejector Basin 30" x 36" 110 gallons 35 lbs. 5 /16" 36" 36 1 /2" 30 1 /2" 30" Fiberglass 96001007 Ejector Basin 36" x 36" 159 gallons 45 lbs. 5 /16" 36" 40" 36 3 /4" 36" Fiberglass

GRUNDFOS HUBS AND FITTINGS Caulking Hubs Adapt-A-Flex Fittings Four 5 /16" mounting holes Size: 3", 4" & 6" (for Fiberglass Basins) Four 5 / 16 " mounting holes Size: 4" only (for Polyethylene Basins) Size: 3", 4" & 6" Sizes Hole Part Number Type Available A B C D E F Saw Size 96001507 Hub 3" 4 3 /4" 2 5 /8" 4 5 /8" 4" 2 1 /8" 3" 96001508 Hub 4" 6" 3 3 /8" 5 7 /8" 5 1 /8" 2 1 /4" 4 1 /8" 96001509 Hub 6" 8" 4 5 /8" 7 3 /4" 7 1 /8" 2 1 /4" 6 1 /8" 96001510 Hub 4" 5 3 /4" 3 3 /8" 5 7 /8" 5 2 1 /4" 3 3 /4" 96001504 Fitting 3" 3 15 /32" 1 /4" 3 1 /8" 4 1 /32" 4" 96001505 Fitting 4" 4 15 /32" 1 /4" 4 1 /8" 5 1 /16" 5" 96001506 Fitting 6" 6 23 /32" 9 /32" 6 13 /32" 7 1 /8" 7"

GRUNDFOS BASIN COVERS s Simplex Simplex with Pump Access Simplex with Inspection and Pump Access Duplex with Inspection and Pump Access Part Number Cover Type Basin Standard A B C D E Cover Approx. Materials Gasket Size Bolt Circle Cover Pump Discharge Vent Inspection Thick- Wt. of & Bolt I.D. -Holes O.D. Access I.D. Size Size I.D. ness (lbs.) Const. Pack 96001008 simplex 18" 19 1 /4-4 20 1 /2" none 2" 2" none 7 ga. 17 steel 96001010 96001009 18" 2" 3" 96001011 96001012 simplex 24" 26 1 /2-6 28" 16" 2" 2" none 1 /4" 48 steel 96001014 96001013 24" 2" 3" 96001014 96001016 simplex 30" 32 1 /2-6 34" 16" 2" 2" 8" 1 /4" 64 steel 96001014 96001017 30" 2" 3" 96001014 96001020 duplex 30" 32 1 /2-6 34" 14" 2" 2" 8" 1 /4" 66 steel 96001015 96001021 30" 2" 3" 96001015 96001024 simplex 36" 38 1 /2-6 40" 16" 2" 2" 8" 1 /4" 93 steel 96001014 96001025 36" 2" 3" 96001014 96001028 duplex 36" 38 1 /2-6 40" 16" 2" 2" 8" 1 /4" 95 steel 96001015 96001029 36" 2" 3" 96001015 GRUNDFOS CHECK VALVES Compression Solvent Weld Materials of Part Number Type A B Box Qty. Construction 96001644 Compression 1 1 /2" 1 PVC, Buna-N 96001645 Compression 2" 1 PVC, Buna-N 96001048 Compression 1 1 /2" 7 1 /2" 5 PVC, Buna-N 96001049 Compression 2" 9 3 /4" 8 PVC, Buna-N 96001050 Compression 3" 14" 2 PVC, Buna-N 96001046 Solvent Weld 1 1 /2" 5 3 /4" 12 PVC, Buna-N 96001047 Solvent Weld 2" 6" 12 PVC, Buna-N

GRUNDFOS JUCTION BOX Specifications MATERIALS: Lid and box are made from a flame retardant, ultra-violet resistant, reinforced PVC. GASKET: Polyethylene foam. SCREWS: 304 stainless steel. ENCLOSURE: NEMA 4X Front View Side View Volume Part Number A B C (cubic inches) 96001051 6" 6" 4 3 /8" 157 GRUNDFOS ACCESSORY & REPLACEMENT FLOAT SWITCHES Approx. Switch Cord Ship. Wt. Product List Model Description Length (lbs./oz.) Number Price ($) TF-10 Tether Float Switch (for Models SU & EF 25) 10' 2 96001643 34.00 VF-10 Vertical Float Switch (for Model EF25) 10' 2 96001642 41.00 FS-10 Wide Angle Mechanical Float Switch, 10' 2 ID3799 43.00 Piggyback Design, Boxed (for Models KP & AP) FS-25 Wide Angle Mechanical Float Switch 25' 3 ID3800 47.00 Piggyback Design, Boxed (for Models KP & AP) GRUNDFOS VERTICAL SWITCH Approx. Switch Max. Cord Ship. Wt. Product List Model Description Run Amps Length (lbs./oz.) Number Price ($) VFS Vertical Float Switch 13 10' 1 96030395 50.00 GRUNDFOS CORD GRIPS Part Number HoleWire Gauge Requirement AWG 96001052 1 /2" NPT 18-3 96001053 1 /2" NPT 16-3 18-3 AWG Wire

BEING RESPONSIBLE IS OUR FOUNDATION THINKING AHEAD MAKES IT POSSIBLE INNOVATION IS THE ESSENCE Contact: L-SE-SL-010 Rev. 05/02 PRINTED IN USA U.S.A. Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66061 Telephone: (913) 227-3400 Fax: (913) 227-3500 www.grundfos.com Canada Grundfos Canada, Inc. 2941 Brighton Rd. Oakville, Ontario L6H 6C9 Telephone: (905) 829-9533 Fax: (905) 829-9512 Mexico Bombas Grundfos de Mexico, S.A. de C.V. Boulevard TLC #15, Parque Industrial Stiva Aeropuerto C.P. 66600 Apodaca, N.L. Mexico Telephone: 011-52-81-8144-4000 Fax: 011-52-81-8144-4010