FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

Similar documents
FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FG-L Technical Data Sheet

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

P/N _F NSF Certified June 2010

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

PWEE Technical Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

RLNIE with INNOVATOR II

RL with INNOVATOR II No Heat Doors

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

RM with INNOVATOR Doors

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

RLT with INNOVATOR Doors

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Nosing Heater. Return Grill Heater

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

RMN with INNOVATOR Doors Technical Data Sheet

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Engineering Plan Views

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

LifeLine Premier RLNIE

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Service Manual

Installation & Service Manual

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

BCH Medium Temperature Merchandisers

MD Medium Temperature Self Contained Open Vertical Merchandisers

Installation & Service Manual

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

MD Medium Temperature Self Contained Open Vertical Merchandisers

Medium Temperature Bulk Produce and Bakery Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

F-6 Multi-deck Frozen Food Wall Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

EcoVision Door Manual

Service Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Self-Contained MERCHANDISERS. February

Reach-in Merchandisers

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

RFLNS, RFMNS & RFLTM Freedom Line

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

Self-Contained MERCHANDISERS. October

Service Merchandisers

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

Installation & Service Manual

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

RFLN & RFMN Freedom Line

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Ultra Low Front Rear Load Medium Temperature

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

SM / SN Medium and Low Temperature Spot Merchandisers

SERIES NAV S Display Merchandisers

Installation & Service Manual

Cabinet & Merchandiser Price List

Transcription:

FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. D E Item Part # Description Wiring Item # Fan Assemblies, and Thermostats A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0252116 Fan Blade (FB.4780611) B. Optional Adj. Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Electric Defrost only) (CT.4440611) D. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) Heaters E. 208V Evaporator Defrost Heaters (5) 0465916 8 ft case (HE.4850630) 0465915 12 ft case (HE.4850631) F. 208V Drip Pan Defrost Heaters, Electric (6) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) 120V Drip Pan Defrost Heaters, Koolgas (7) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) Item Part # Description Wiring Item # Heaters (continued) G. Nosing Anti-sweat Heaters (8) 0524419 8 ft case (HE.4851257) 0524421 12 ft case (HE.4851259) H. Return Grille Anti-sweat Heaters (9) 0524427 8 ft case (HE.4851251) 0524429 12 ft case (HE.4851253) I. Return Glass Anti-sweat Heaters (10) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839) J. Discharge Glass Anti-sweat Heaters (11) 0504300 8 ft case (GL.4969359) 0504342 12 ft case (GL.4990684) Glass Lid Parts are listed on page 5. Optional LED Fixtures and Power Supply K. 0501213 Power Supply (EP.4481861) (12) L. LED Fixture (13) Data sheet-excel FIG-L Note: Revision F: removed 6 foot data. Other changes marked by bar, underline or circle. 2018 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0538939

Engineering Plan Views Intermediate Island Frozen Food FI / FIG 39 ⅞ (1013) Electrical Field Connection 41 ½ (1054) 8 ¼ (217) Electrical Stub Up Area 6 x 6 (152 x 152) Waste Outlet Wireway NOTE: Case-to-Case Electrical Connections are made IN FRONT OF SPLASHGUARD. A 26 ½ (673) Dimensions shown as inches & (mm). B D 43 ⅞ (1114) 4 ¼ (108) 4 ¾ (120) Splashguard C FRONT 41 ½ (1054) Splashguard Refrigeration Outlet Waste Outlet PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 4 ½ (115) 8 (203) 42 ⅛ (1071) 11 ¾ (299) 46 ¼ (1175) 12 ⅛ (307) 47 ⅝ (1209) 49 ⅜ (1254) 58 (1471) 8 ft 12 ft General (A) Case Length (without ends or partitions) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 58 (1471) 58 (1471) Back of case to front of splashguard 49 3 /8 (1254) 49 3 /8 (1254) Back of case to O/S edge of front leg 46 1 /4 (1175) 46 1 /4 (1175) Distance between edges of external legs and center legs 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA 43 7 /8 (1114) Distance between front legs and splashguard 3 1 /8 (82) 3 1 /8 (82) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 84 1 /4 (2141) 132 3 /8 (3363) Back of case to center of stub up area 39 7 /8 (1013) 39 7 /8 (1013) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 90 1 /8 (2289) 138 1 /4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 84 1 /4 (2141) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 47 5 /8 (1209) 47 5 /8 (1209) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 42 1 /8 (1071) 42 1 /8 (1071) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 2 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM FIG-L Technical Data Sheet

Intermediate Island Display with Glass Walls and Lids Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Excel FIG-L Low / Medium Temperature FIG-L 40 (1016) 24 ⅜ (618) Case-to-Case Connection Refrigeration Outlet 3 ⅛ (79) Open Close 15 ⅞ (404) Dimensions shown as inches & (mm). 58 (1471) 47 ⅞ (1218) Fan 34 ⅜ (873) Load Limit 42 ⅛ (1071) 46 ¼ (1175) 47 ⅝ (1209) 49 ⅜ (1254) Open Close 15 ¼ (388) Coil 5 ½ (140) REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. Med FF IC Discharge Air ( F) +32-10 -14 Evaporator ( F) +25-18 -20 Unit Sizing ( F) +23-21 -23 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Btu/hr/ft* Med FF IC Parallel 212 290 300 Conventional 216 303 315 * Add 1.5 Btu/hr/ft for LED lighting. DEFROST DATA Med FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 0.2 0.2 0.15 (± 15% based on case configuration and product loading). Electric Med FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 30 50 60 Gas Duration (minutes) NA 15 18 Estimated Charge *** 8 ft 2.5 lb 40 oz 1.1 kg 12 ft 3.7 lb 59 oz 1.7 kg ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg). NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Offtime Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO ** Med +28 F / +16 F FF -15 F / -27 F IC -21 F / -33 F Indoor Unit Only, Pressure Defrost Termination* Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. P/N 0523825_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 8

Excel FIG-L Low / Medium Temperature Electrical Data 8 ft 12 ft Number of Fans 4W Evaporator 2 2 Amperes Watts 8 ft 12 ft 8 ft 12 ft Evaporator Fans 120V 50/60Hz Standard Energy Efficient 0.24 0.24 16 16 230V 50/60Hz Standard Energy Efficient 0.12 0.12 16 16 230V 60Hz Export 0.30 0.30 48 48 230V 50Hz Export 0.36 0.36 54 54 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.34 0.52 41 62 230V 50/60Hz Export 0.18 0.27 41 62 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 0.78 1.08 230V 50/60Hz Standard Energy Efficient 0.50 0.65 230V 60Hz Export 0.68 0.92 230V 50Hz Export 0.74 1.01 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Return Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.08 0.11 9 13 230V 50/60Hz Export 0.04 0.06 9 13 Discharge Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.46 0.66 55 79 230V 50/60Hz Export 0.24 0.34 55 79 208V Electric Defrost (Coil & Drain Heater) 9.13 13.94 1900 2900 230V Export Electric Defrost (Coil & Drain Heater) 8.26 12.61 1900 2900 120V Koolgas Defrost 1.67 3.33 200 400 Only lighting configurations that are compliant with the U.S. Dept. of Energy (DOE) 2017 regulation are available for sale for use in the U.S.A. Standard Lighting None Optional Lighting LED 120V 50/60Hz 0.50 0.70 60 84 LED 230V 50/60Hz 0.26 0.37 60 84 Please note: some combinations of fluorescent lights on this case model may not be compliant with DOE 2017 and may not be available to order in the US and Canada. More lighting options are available with LED lights. The Hussmann Product Configurator will not allow lighting options that do not comply with the DOE 2017 standards. 4 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM FIG-L Technical Data Sheet

Excel FIG-L Low / Medium Temperature Product Data Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft) 5.30 ft 3 /ft (0.49 m 3 /m) 4.63 ft 2 /ft (1.41 m 2 /m) 4.00 ft 2 /ft (1.22 m 2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is none. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 8 ft 12 ft (each) lb (kg) 1150 (522) 1420 (695) 50 (23) 4 Actual weights will vary according to optional kits included. Glass Lid Replacement Parts FI4GL, FI8GL, FI12GL Glass Assemblies S. 0524241 Top Glass - Fixed B00150 (GL.4998363) T. 0524242 Middle Glass with Handle B00151 (GL.4998364) U. 0524243 Bottom Glass with Handle B00152 (GL.4998365) FI6GL Glass Assemblies S. 0524259 Top Glass - Fixed B00168 (GL.4998366) T. 0524260 Middle Glass with Handle B00169 (GL.4998367) U. 0524261 Bottom Glass with Handle B00170 (GL.4998368) S T U P/N 0523825_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 8

Electric Defrost Standard 120V Neutral 120V Power 1 8 9 Brown Band Brown Band Fans Nosing Anti-Sweat Heater Return Grille Anti-Sweat Heater Refrigeration Thermostat (Optional) Defrost Termination Thermostat 2 3 Light Blue To Condensing Unit Dark Blue To Condensing Unit L1 208V Power From Defrost Contactors L2 Red 6 Drip Pan Heater 5 Red Electric Defrost Heaters Return Glass Anti-Sweat Heater Discharge Glass Anti-Sweat Heater Purple White Purple White 10 10 120V Power 120V Neutral 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers Grayed components in 12 foot models only. 6 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM FIG-L Technical Data Sheet

Gas Defrost Optional 120V Drip Pan Heater Koolgas Only Yellow Yellow Dark Blue 7 4 Heater Switch Dark Blue 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers P/N 0523825_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 8

Excel FIG-L Low / Medium Temperature Optional LED Lighting Wiring Diagrams Light Switch Black Input Output Power Supply 24VDC Red Blue LED Cable Tray 120 VAC from Wireway White 12 LEDs 13 FI8GL LED Wiring Diagram Light Switch Black Input Output Power Supply 24VDC Red Blue LED Cable Tray 120 VAC from Wireway White 12 LEDs 13 FI12GL LED Wiring Diagram 8 of 8 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM FIG-L Technical Data Sheet