Vaisala HVAC. Product family presentation. Vaisala

Similar documents
Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Accuracy by Design Products for the HVAC Professional

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

SEQUENCE OF OPERATIONS

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

CD-Px Series Duct Mount CO 2 Transmitters

Toxic Gas Detection. Model F12. Toxic Gas Detection

Relative Humidity Transmitters

02/11/2015

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

Seamlessly integrated. The new sensor range from Belimo.

SIMRAD GD10PE IR GAS DETECTOR

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

02/11/2015

EC FX NH3. A new and improved approach to ammonia gas detection

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Appendix A Equipment Used to Monitor Hotels

Installation and Wiring 1.

Chillgard Refrigerant Monitor

Dräger X-am 7000 Multi-Gas Detection

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Carbon Monoxide Transmitter

SIMRAD GD10 IR GAS DETECTOR

Recalibrate the way you look at gas detection

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

WRF04 CO 2 RS485 Modbus

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Moisture and Hydrocarbon Dew Point Measurement

Temperature Controllers

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

Sensepoint XCL Fixed Gas Detector

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Temperature Solutions Line Card

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

S5000 Gas Monitor. GMS5000.com

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

SENSORS TRANSMITTERS. Process monitoring

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Multifunction IAQ Monitor

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Carbon Monoxide CO Transmitter ADT-X3-1110

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

CALIBRATION HOW IT WORKS

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

APPLICATION DATA SHEET

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Moisture and Hydrocarbon Dew-Point Measurement

Sensor Selection Guide. Sensing for Building Applications

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Open-area Smoke Imaging Detector. Engineering Specification

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Digital, not analog: One manifold for all refrigeration systems.

TER Active Room Temperature Sensor (Controller),

Dew-Point Transmitters and Instruments

RSMFM-2R MULTIFUNCTIONAL

CLEANROOM MONITOR CR3A Network - Installation Instructions

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

Complete packages with Software and Controller

HIH-4010/4020/4021 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Products and performance

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

CALIBRATION HOW IT WORKS

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

DMFPM-2R MULTIFUNCTIONAL

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

A New Standard of Excellence

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Analog Room Pressure Monitor RPC Series

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Hydrazine Analyzer Series 2171 Specifications

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

Transcription:

Vaisala HVAC Product family presentation Vaisala

Technological Leadership Technology used in Mars curiosity rover Inhouse manufacturing in our own cleanroom located in Finland Humidity and dew point sensors CO 2 sensors including light sources, detectors, and filters Barometric pressure sensors Temperature sensors Vaisala HVAC Product Presentation B211486EN-D Vaisala 2

Vaisala HVAC Product Families Features 80-series 90-series 110-series Vaisala inhouse sensing technology 2-year warranty Duct/outdoor models Calibration certificate Smart measurement modules Field adjustable Configurable options Splashproof *) Enhanced chemical tolerance *) in some models Vaisala HVAC Product Presentation B211486EN-D Vaisala 3

The 80-series HMW80 humidity and GMW80 CO 2 transmitters Cost-efficient for measuring indoor air quality (IAQ) Vaisala HUMICAP and CARBOCAP sensor technology long lifetime long-term stability minimal lifetime cost suitable for spaces occupied 24/7 (CARBOCAP ) thanks to true internal reference measurement GMW80 series transmitters. Vaisala HVAC Product Presentation B211486EN-D Vaisala 4

The 80-series Sensor location Low self-heating thanks to CARBOCAP sensor Accurate CO 2 and temperature measurements in a single device Easy installation: No warm-up time or calibration period Loop-powered versions available Wiring in the back plate snap-on cover Wide-range of cost-efficient options available at short delivery times Another brand Sensor location Vaisala GMW83D Abiove: Comparison of self-heating between Vaisala GMW83D and another brand. Wiring in the back plate. Vaisala HVAC Product Presentation B211486EN-D Vaisala 5

The 90-series HMW90 humidity and GMW90 CO 2 transmitters Designed for the most demanding HVAC applications Calibration certificate included Highest accuracy Digital ModBus RTU / BACnet MSTP outputs available Field serviceable Low life-cycle cost Vaisala HVAC Product Presentation B211486EN-D Vaisala 6

The 90-series Field serviceable Module replacement (calibration certificate included) Calibration against a Vaisala handheld meter or calibration gas Reduced life-cycle cost Calibrating the HMW90 using the Vaisala HUMICAP Handheld Humidity and Temperature Meter HM70 Available in different colors Decorative cover For best fit to architectural environment Decorative covers help to camouflage the 90-series transmitters. Vaisala HVAC Product Presentation B211486EN-D Vaisala 7

The 110-series HMDW110 series HUMICAP technology Designed for demanding applications also in washdown areas IP65 duct- and wall-mounted options and also for outdoors with a radiation shield ±2 %RH accuracy and long-term stability Traceable calibration certificate included 4 20 ma loop-powered outputs Wall- and duct-mounted options and for use outdoors together with a radiation shield. Vaisala HVAC Product Presentation B211486EN-D Vaisala 8

The 110-series Compatible with the RDP100 remote display Special sensors available for H 2 O 2 disinfection application Field serviceable Easy installation HMS110 in freezing conditions. Vaisala HVAC Product Presentation B211486EN-D Vaisala 9

The 80-series options HMW80 series models Features TMW82 TMW83 HMW82 HMW83 HMW88 HMW88D HMW89 HMW89D RH measurement Humidity parameters T measurement 4... 20 ma 0... 10 V Wall-mounted HMD80 series models Features TMD82 TMD83 HMD82 HMD82D HMD83 HMD83D HMS82 HMS83 RH measurement Humidity parameters T measurement 4... 20 ma 0... 10 V Duct-mounted Outdoor mounting Vaisala HVAC Product Presentation B211486EN-D Vaisala 10

The 80-series options GMW80 series models Features GMW84 GMW84S GMW83 GMW83A GMW83RP GMW83T GMW83D GMW83DRP GMW86P GMW88 CO2 measurement T measurement 2) 2) 1) 1) Humidity measurement 4... 20 ma 1) Passive Pt1000 2) Passive Pt1000 and active voltage output 0...10 V Traffic lights Relay Temperature setpoint Display IP64 Vaisala HVAC Product Presentation B211486EN-D Vaisala 11

The 90-series options HMW90 series models Features TMW92 TMW93 HMW92 HMW92D HMW93 HMW93D HMW95 HMW95D RH measurement T measurement Calculated parameters 4...20 ma 0...5/10 V Bacnet MS/TP ModBus RTU Display Relay GMW90 series models Configurable models are: - TMW90 - HMW90 - GMW90 - GMW90R Features GMW93 GMW93D GMW93R GMW93RD GMW93RA GMW94 GMW94D GMW94RD GMW95 GMW95D GMW95R GMW95RD CO 2 measurement RH measurement T measurement Calculated parameters 4..20 ma 0..5/10 V Bacnet MS/TP ModBus RTU Display LED indicator Vaisala HVAC Product Presentation B211486EN-D Vaisala 12

The 110-series options HMDW110 series models Features HMW110 HMD110 HMS110 HMW112 HMD112 HMS112 RH T Calculated parameters Wall-mounted Duct-mounted Outdoor mounting Catalytic sensor * * Configurable outputs Modbus *) Catalytic sensor for environments with hydrogen peroide desinfection. Vaisala HVAC Product Presentation B211486EN-D Vaisala 13

Additional Information Visit www.vaisala.com/hvac Contact your local sales representative at https://www.vaisala.com/en/contact-us Read about interesting stories on our site https://www.vaisala.com/en/about-vaisala/news-and-media/blogs-and-success-stories On-line store https://store.vaisala.com Visit our document download center Vaisala HVAC Product Presentation B211486EN-D Vaisala 14

Sensor Technology HUMICAP and CARBOCAP Vaisala

Vaisala HUMICAP Humidity Sensor HUMICAP sensor is used in Demanding industrial applications Power generation Auto industry Industrial drying Paper mills HVAC Benefits of HUMICAP sensor Unbeatable stability indoors and outdoors Accurate measurements not only today, but after years of use Robustness The sensor tolerates dust, dirt and high humidity Selectivity Fresh paint, cleaning fluids and new building materials do not cause false readings or drift Vaisala HVAC Product Presentation B211486EN-D Vaisala 16

Vaisala HUMICAP Humidity Sensor Humicap180R specified stability in typical HVAC applications: ± 0.5 %RH/year Vaisala HVAC Product Presentation B211486EN-D Vaisala 17

Vaisala CARBOCAP CO 2 Sensor CARBOCAP CO 2 sensor Brings analyzer-level reliability to HVAC measurements Dual wavelength single-beam technology guarantees the best possible stability. Benefits of CARBOCAP sensor Immediately correct measurements when plugged in, no waiting for the sensor to correct offset drift Works also in spaces occupied 24/7 as reference measurment is performed in every cycle Ecellent stability and long lifetime with proprietary microglow lightsource Vaisala HVAC Product Presentation B211486EN-D Vaisala 18

Vaisala CARBOCAP CO 2 Sensor Legend: Largest value 75% fractile Median 25% fractile smallest value The light output from the microglow chip is much more stable over time than traditional filament lamps. This means improved CO 2 measurement stability and longer sensor lifetime Emitter Reference and CO 2 measurement is performed on every measurement cycle using an inhouse tunable filter chip. This guarantees ecellent stability and low temperature dependence. 1000 ppm stability test results for 23 powered units in office conditions shown in picture with ±75 ppm 5-year total accuracy specification. Membrane for thermal insulation Frame Vaisala HVAC Product Presentation B211486EN-D Vaisala 19

Vaisala CARBOCAP CO 2 Sensor Animation of the Operating Principle www.vaisala.com/carbocap Vaisala HVAC Product Presentation B211486EN-D Vaisala 20