CabLite Luminous Auto Light Control Installation Manual

Similar documents
CabLite ECO Installation Manual

CabLite VR LED Lighting System Installation Manual

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Door Release Power Supply

FLT93 Installation, Operation and Troubleshooting Guide

Introduction... 1 System Overview... 1 System Diagram... 2

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Installation Guide for models:

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

Rack Mount Series Installation Guide

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Series. Access Power Controllers. Installation Guide

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

PM100/PM100E PLANTER MONITOR. Operator s Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Operation & Maintenance Manual

Installation Guide for models:

Dryer Controller M720

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Beacon 800 Gas Monitor Operator s Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ITEM # SAIL STREAM CEILING FAN MODEL #40048

Powerohm Resistors Digital HRG System

SAFETY INFORMATION AND WARNINGS

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

ADC150 Automatic Draft Control

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

User Manual. Dryer Controller M720

Public Safety DAS Annunciator Panel

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

EVO192 v3.0 Fire and Burglary What s New

SA SIREN AMPLIFIER

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Model 4001 Series Single Channel Controller

MaxLite LED High Bay Fixtures

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

ion Genesis Pump Controller

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

ITEM # SAIL STREAM CEILING FAN MODEL #41695

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

52 STRATHMERE CEILING FAN

Installation, Operation & Service Manual

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Electric Space Heater

60In. Ceiling Fan. Owner s Manual

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

NetworX NX-548E Receiver Installation Instructions

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DS160/161 Request To Exit PIR sensors Installation Instructions

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Introduction... 1 System Overview... 1 System Diagram... 2

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ENERVEX ADC100 DRAFT CONTROL

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Accessible Toilet Alarm

KM300 Carbon Monoxide Detection System Installation Manual

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

Operating Instructions

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

INSTANT HOT WATER DISPENSER

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

Remote Relay Module (RRM)

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

INSTRUCTION MANUAL PC255O

Transcription:

CabLite Luminous Auto Light Control Installation Manual REV: 1.1 DATE: 1/17/2018 MANUAL NUMBER: 29 Electronic Controls Inc 7073 North Atlantic Ave Cape Canaveral, FL 32920 WWW.ECIAMERICA.COM

REV DATE DESCRIPTION 1.0 3/8/2017 Original release 1.1 1/17/2018 Updated to new logo www.eciamerica.com P a g e 2

Table of Contents 1 Introduction... 4 2 Warning and Disclaimer... 4 3 Trademarks... 4 4 Conventions Used... 4 5 Safety Information... 5 6 System Overview... 6 6.1 Downlights... 6 6.2 Downlight Specifications... 6 6.3 CabLite Luminous... 7 6.3.1 Auto Light Control Operation... 7 6.3.2 Control Board... 7 6.4 CabLite Luminous w/ Emergency Lighting... 9 6.4.1 Emergency Board... 9 7 Installation... 10 7.1 Flat Bezel Downlight Dimensions... 10 7.2 Raised Bezel Downlight Dimensions... 10 7.3 Luminous Wiring Diagram... 11 7.4 Luminous w/ Emergency Lighting Wiring Diagram... 12 8 Lighting and Control Adjustments... 12 8.1 Brightness Adjustment... 12 8.2 Dimming Level Adjustment... 13 8.3 Auto Light Control Adjustment... 13 9 Trouble Shooting... 13 9.1 One Light Does Not Turn On... 13 9.2 Lights Do Not turn On (CabLite Luminous)... 13 9.3 Lights Do Not Turn On (CabLite Luminous & w/emergency)... 13 9.4 No Emergency Lights with AC loss (Emergency light option)... 13 9.5 Emergency Lights Do Not Light with AC Power (Emergency light option)... 14 9.6 Downlights Turning Off and not coming back on... 14 9.7 No Dimming with pins 7 & 8 connected... 14 www.eciamerica.com P a g e 3

1 Introduction This manual is intended for facilitate the installation of CabLite ECO lighting system manufactured by Electronic Controls Inc. The audience of the material included in this manual is for certified installation personnel. The CabLite ECO lighting system complies with modern performance specifications and meets or exceeds code requirements. Installation and adjustments must meet local, state and national codes. 2 Warning and Disclaimer Thank you for purchasing equipment from ECI America, INC. We want your new equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed, and to verify that the equipment, installation and operation is in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, ASMEA17.1 Safety code for Elevators and Escalators and the codes of the National Electrical Manufacturer s Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious injury to personnel can result from failure to follow all applicable codes and standards. We do not guarantee the products described in the publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for use or resale as online control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation of communication systems, air traffic control, direct life support machines or weapon systems in which the failure of the product could lead directly to death, personal injury, or severe physical or environmental damage ( High Risk Activities ). ECI America, Inc. specifically disclaims any expressed or implied warranty of fitness for High Risk Activities. This publication is based on information that was available at the time it was printed. WE reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. 3 Trademarks All trademarks or registered product names appearing in this document, as they pertain to Electronic Controls, Inc., are the exclusive property of 4 Conventions Used www.eciamerica.com P a g e 4

When you see the notepad icon in the left-hand margin, the paragraph to its immediate right will be a special note. Notes represent information that may make your work quicker and more efficient. The word NOTE: in boldface will mark the beginning of the text. When you see the exclamation point icon in the left hand margin the paragraph to its right will be a warning. The information could prevent injury, loss of property, or even death in extreme cases. Any waring in this document should be regarded as critical information that should be read in its entirety. The word WARNING: in boldface will mark the beginning of the text. 5 Safety Information Know the safety hazards related to any procedure you are about to perform. Know what equipment has been specified for each specific contact and know what tools and materials you should plan to have available. Before connecting electrical wiring, take precautions to prevent accidents from happening to yourself and others around you. ALWAYS CONSIDER SAFTY FIRST! Wear a hard hat when working in the hoist way. Wear safety glasses or goggles when using power tools Always wear protective gloves when installing or removing access covers, conduits, wire way or electrical devices. When working on car canopy, always be aware of where the sides of the car are located. Use properly grounded cords and power equipment (ground fault circuit interrupters). Make sure there are proper clearances in hoist way between the car and other devices. Before connecting wiring, cover sharp edges to keep hands and arms from being cut. Always know where other people are and how the elevator wiring can affect their safety. Safety lock and tag out procedures are always required before performing and kind of service, repair, adjustment, lubrication or inspection of power equipment. To reduce the danger of electrical shock, always make sure electrical connections are secure. Also make sure no bare wires are exposed after pulling cable. Use a circuit tester to be certain the circuit is not active before touching it. www.eciamerica.com P a g e 5

6 System Overview The CabLite Luminous is a microprocessor control lighting system for use passenger, residential and freight elevators cabs. Any combination between one and twelve downlights can be used. The CabLite Luminous system provides general lighting that meets or exceeds ASME A17.1, local, state and federal codes. There are 2 available options for the CabLite Luminous lighting system. The standard system is general lighting with the following: Brightness control Dimming control Standby mode for idle or sleeping cabs Motion sense for energy savings during low traffic times With the EMERGENCY LIGHTING option, you get everything in the standard Luminous system plus emergency lighting eliminating the need for separate emergency lights. 6.1 Downlights Each downlight is equipped with 2 connectors (located on the top of the can) for chaining up to 12 lights together. The 2 connectors are interchangeable so it does not matter which cable is connected to it. See Figure 1 - Downlight. Each downlight has 2 spring loaded clips that hold the light tight to the ceiling panel. Figure 1 - Downlight 6.2 Downlight Specifications Operating voltage 24VDC 5000K 4000K 3000K # of LEDs 1 1 1 Color Temp 5000K 4000K 3000K Power Consumption 8W 8W 8W CRI 80 +/-5 85 +/-5 85 +/-5 www.eciamerica.com P a g e 6

6.3 CabLite Luminous The CabLite Luminous Standard lighting system incorporates Brightness, Dimming and Auto Light control for up to 12 downlights. In addition, there is a standby mode which turns off all downlights for idle or shut down cabs. The CabLite Luminous lighting system includes the following 1 to 12 downlights One 8 cable for the first downlight One 4 cable for each additional downlight Gang box which includes: o 24VDC power supply o Control Board o cover 6.3.1 Auto Light Control Operation Auto Light Control is achieved through a motion sensor on the control board. This function is enable through a switch setting on the control board. The sensitivity and duration are set using potentiometers. There are 2 downlights that are specifically marked for this operation. These 2 downlights remain on when Auto Light Control (motion) has timed out. This is a code requirement and the placement of these 2 downlights should be decided before installation. 6.3.2 Control Board Figure 2- Control board 6.3.2.1 Control Board Connections 1 + 24VDc input from power supply 2-24VDc input from power supply 3 GND connection 4 FAN control relay COM 5 FAN control relay N.C. - Closed between pin 4 relay common when in STBY 6 FAN control relay N.O. - Open between pin 4 relay common when in STBY 7 and 8 Diming control. When shorted downlights go to dimming level set by DIM LEVEL potentiometer (P2). www.eciamerica.com P a g e 7

8 and 9 STBY When shorted system is put into STANDBY mode turning off all downlights and picking FAN Control relay. 11 EXT POT brightness adjustment 12 EXT POT Dimming Level adjustment 13 EXT POT Common Figure 3 - External POT connections LIGHTS connector 3 pin connector for connecting to the first downlight. 6.3.2.2 Control Board Indicators POWER LED lit when 24VDC present. Blinks at initial startup then stays on. MOTION LED Lit when motion is detected (when motion dip switch in ON position) OVERLOAD LED TEST LED Lit when TEST button is pressed for adjusting and testing motion sensitivity. STANDBY LED lit when pin 9 and 10 are shorted putting unit in standby mode DIMMING LED lit when pins 7 and 8 are shorted putting unit in dimming mode. FAN 6.3.2.3 Control Board Configuration and Adjustments BRIGHTNESS potentiometer for setting maximum light level during normal operation DIM LEVEL potentiometer for setting downlight dim level when DIM pins 7 and 8 are shorted. MOTION SENSOR potentiometer for setting the motion sensitivity level. Clockwise decreases sensitivity. SHUT OFF DELAY potentiometer for setting the time duration without any motion before system shuts down lighting. Adjustable from 5 to 15 minutes. Valid only when MOTION DIP switch is in ON position. MOTION DIP Switch When in the ON position (see Figure 4 - Motion DIP switch) the system will shut down all but 2 downlights with no motion detected for period set by SHUT OFF DELAY. www.eciamerica.com P a g e 8

Figure 4 - Motion DIP switch TEST push button Pressing TEST push button lights the TEST LED and sets the SHUT OFF delay from 5 to 15 seconds for adjusting motion sensitivity. When complete pressing TEST button again will turn off TEST LED and put unit in normal operating mode. 6.4 CabLite Luminous w/ Emergency Lighting 6.4.1 Emergency Board Figure 5 - Luminous Emergency Board 6.4.1.1 Emergency Board Connections 1 BELL neg output to 12VDC audible sounder 2 BELL + positive output to 12VDC audible sounder 3 & 4 BELL SW When shorted puts 12VDC between pins 1&2 for ringing bell or audible device. 5 +BAT positive input from battery. 6 -BAT negative input from battery 7 Fault relay Contact 8 Fault relay Contact 9 Fault relay Contact EMERGENCY LIGHTS 3 pin connector for first emergency light in string. 6.4.1.2 Emergency Board Indicators POWER LED - +24VDC power present CHARGE LED lit when battery is charging FAULT LED Lit when there is a battery charging problem. 6.4.1.3 Emergency Board Settings 6/12V DIP Switch set based on battery voltage. www.eciamerica.com P a g e 9

7 Installation Be sure all power is turned off before starting installation. Locate the positions where you want each downlight and drill the ceiling panels according to the specifications for your downlight listed in sections 7.1 and 7.2. Be sure there is a minimum 1 clearance between the top of the downlight can and the cab top to accommodate the connectors. See Figure 8 - Installation example 7.1 Flat Bezel Downlight Dimensions 7.2 Raised Bezel Downlight Dimensions Figure 6 - Flat Bezel Measurements Figure 7 - Raised Bezel Measurements www.eciamerica.com P a g e 10

Figure 8 - Installation example 7.3 Luminous Wiring Diagram Figure 9 - Luminous Wiring Diagram Wire AC power to power supply as shown in Figure 9 - Luminous Wiring Diagram. Be sure to secure AC power line through the case of the control box with appropriate hardware AC IN line Brown wire on power supply AC IN neutral Blue wire on power supply The DC output of the power supply is factory wired to the Control Board. Route the 8 cable through the control box punch out (securing properly) to the first downlight and connect remaining downlights with 4 cables. The two connectors on the downlights are interchangeable so cable connection does not matter. Once wiring is complete apply power to lighting system. Check that all downlights are lit. See section 8 Lighting and Control Adjustments for configuring and adjustments. www.eciamerica.com P a g e 11

7.4 Luminous w/ Emergency Lighting Wiring Diagram Figure 10 - Luminous w/ Emergency Wiring Diagram The power supply DC output is prewired from the factory to the control board. The BATTERY negative terminal is prewired to the control board and the positive terminal is left disconnected. Route AC power through one of the punch outs of the gang box and secure cable to box with appropriate hardware. Connect AC in as shown in Figure 10 - Luminous w/ Emergency Wiring Diagram AC IN line Brown wire on power supply AC IN neutral Blue wire on power supply Route the 8 cable through another punch out of the gang box and secure to box using proper hardware. Connect the 8 cable to the first downlight and the remaining downlights with the 4 cables. The two connectors on the downlights are interchangeable so cable connection does not matter. The EMERGENCY lights are connected through a second 8 cable as shown in Figure 10. The standard number of downlights in the emergency lighting string is two. Connecting more than two will shorten the emergency lighting time. With all downlights connected, remove the plastic cover from the POS terminal of the battery and connect RED wire from control board to battery POS terminal. The EMERGENCY downlights should light at this time. Apply AC power to CabLite system. All downlights should light. See Section 8 Lighting and Control Adjustments for configuring and adjustments. 8 Lighting and Control Adjustments 8.1 Brightness Adjustment Adjust the brightness of the downlights using the BRIGHTNESS pot located on the Control Board. www.eciamerica.com P a g e 12

8.2 Dimming Level Adjustment If the dimming function is to be used, place a jumper between pins 7 & 8 of control board. Using the DIM LEVEL pot, adjust light level to desired setting then remove jumper. 8.3 Auto Light Control Adjustment 1. Set the MOTION DIP switch to the ON position. See Figure 4 - Motion DIP switch. 2. Press TEST button once. The TEST LED should light. This changes the SHUT OFF DELAY from 5-15 minutes to 5 15 seconds. 3. Turn the SHUT OFF DELAY fully counterclockwise. This should set the delay to approx. 5 seconds with TEST LED lit. 4. Close the car doors and wait until all but 2 downlights turn off. 5. At that point open the doors. If downlights do not turn on with the opening of the door, adjust MOTION SENSOR pot and repeat steps 4 & 5 until sensitivity is acceptable. 6. You can adjust the SHUT OFF DELAY with the TEST LED lit. Timing is 5 to 15 seconds with TEST LED on. Should convert to 5 to 15 minutes once TEST LED is off i.e. 10 seconds should be 10 minutes. 7. When complete PRESS TEST button to disable test operation. 8. Replaced cover to control box. 9 Trouble Shooting 9.1 One Light Does Not Turn On 1) Swap downlight with another light in string. a) If light still does not operate replace downlight. b) If downlight lights, then check original connection to downlight. i) Replaced cable if necessary 9.2 Lights Do Not turn On (CabLite Luminous) 1) Check connection between power supply and first downlight. 2) Check for 24VDC at power supply output a) If no 24VDC check for 120VAc at power supply input i) If 120VAC present replace power supply. b) If 24VDC present replace 8 cable 9.3 Lights Do Not Turn On (CabLite Luminous & w/emergency) 1) Check connection between control board and first downlight. 2) Using DVM measure +OUT- for 24VDC. a) If no 24VDC check for 24VDC at +INi) If no 24VDC at +IN- then check for 120VAC at power supply input ii) If 120VAC present replace power supply. b) If 24VDC present at +IN- then replace Control board. 3) If 24VDC present at +OUT- then check continuity of 8 cable and replace if necessary. 9.4 No Emergency Lights with AC loss (Emergency light option) 1) Check connection between control board and first emergency downlight in string. a) Check continuity of 8 cable and replace if necessary. www.eciamerica.com P a g e 13

2) With no AC power applied and battery connected, check for 12VDC at +EM- output of control board a) If no 12VDC, check connections between battery and control board. b) Check Battery voltage for 12VDC and replace battery in necessary. 3) Check FAULT LED on control board (AC power required). a) If lit replace battery 9.5 Emergency Lights Do Not Light with AC Power (Emergency light option) 1) Check connection between control board and first downlight. 2) Check for 24VDC at +EM- output. a) If 24VDC present replace 8 cable b) If no 24VDC replace control board. 9.6 Downlights Turning Off and not coming back on 1) Check Motion Sensor Adjustment (section 8.3) if Motion Enabled (Figure 4 - Motion DIP switch) a) If Motion not desired turn switch OFF 9.7 No Dimming with pins 7 & 8 connected 1) Check DIMMING LEVEL adjustment by shorting pins 7 & 8 of control Board and turning DIMMING LEVEL pot fully clockwise and counter clockwise to see if lighting level changes. a) If no change, replace Control Board b) If level changes then check that the BRIGHTNESS level is different than the DIMMING level www.eciamerica.com P a g e 14