Technical Note Index

Similar documents
REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Personal & Portable Gas Monitors

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Fixed Gas Detection Equipment

Xgard. Fixed detectors For flammable, toxic or oxygen gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

IGD.CO.UK

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Toxic Gas Detection. Model F12. Toxic Gas Detection

APPLICATION DATA SHEET

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

G-TECTA TM. Portable Gas Detection Instruments

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OLC(T) 100 FIXED GAS DETECTOR

P R O D U C T D ATA S H E E T

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

3M Oldham OLCT 100. Description. Fixed Gas Detector

Monitores Personales. Personal Monitor

Dräger Pac 7000 Single-Gas Detection Device

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GAS ANALYSIS / DETECTION Gas Detector

ALTAIR 5X Multigas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Frequently Asked Questions

portable gas analyser

Sieger Apex. Flexibility that meets your requirements

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

GAS DETECTION International Gas Detectors CH4 NO

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Model D12. Digital Gas Transmitter

ALTAIR 5X Multigas Detector Product Specification

Micro III (Models G203, G203S, and G213) Operation Manual

IRmax & IREX accessories

GAS DETECTOR ST400EC PART.NO

PROTÉGÉ ZM SINGLE GAS MONITOR

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Gasmonitor+ Installation, Operation and Maintenance Manual

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

SUPREMATouch. Modular Fire & Gas Detection System

Micro IV Operation Manual

SP-220. Features. Combustible handheld gas leakage detector

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

MICRO III (G202 / G202s / G212) Single Gas Detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Hygrometer / Air Quality Meter

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Crowcon Gasmaster. 1 to 4 channel gas detection control panel. Installation, Operation and Maintenance Manual

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

BST-MG01 Single Gas Detecting Alarm Manual Instruction

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MICRO IV. Operation Manual. Single Gas Detector

SUPREMATouch Modular Fire & Gas Detection System

Dräger X-am 5000 Multi-Gas Detection

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

Understanding the practicalities of using gas detectors in confined spaces

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

SUPREMATouch. Modular Fire & Gas Detection System

Clip SGD. Portable single Gas Detector. User manual

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

APPLICATION DATA SHEET

UniSens 2-Wire Gas Transmitter

Tetra. User Manual. Personal Multigas Monitor M May 2010 Issue 10

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

GAS DETECTION SYSTEMS

P R O D U C T D ATA S H E E T

Stand Alone DYNAGARD SP Operation Manual

ALTAIR 5X Multigas Detector

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Gasman. User Manual. Personal Single Gas Monitor. M07630 Sep 2015 Issue 11

Fixed Gas & Flame Detection International Product Range Overview

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Gasman. User Manual. Personal Single Gas Monitor. M07630 Oct 2010 Issue 10

Dräger X-am 2500 Multi-Gas Detector

MSA Portable Gas Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

Tetra 3. Personal Multigas Monitor. User Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

Transcription:

Technical Note Index CELLARSAFE FCS001 - CELLARSAFE TERMINAL PCB CONNECTIONS 13/02/07 FCS002 - NON RESPONDING CARBON DIOXIDE CELLARSAFE 23/08/07 FCS003 - OXYGEN SENSOR REPLACEMENT INSTRUCTIONS 25/03/09 FCS004 - OXYGEN SENSOR REPLACEMENT INSTRUCTIONS FOR 3-YR SENSOR 02/07/2010 FCS005 CELLARSAFE WITHOUT REPEATER UNIT 26/04/2012 FSC006 Cellarsafe O2 sensor calibration 29/04/14 CIRRUS (Obsolete Product) CROWCON CLIP / Clip SGD CC0001 - Firmware Upgrade instructions via the IR Link 01/03/13 CC0002 - Firmware Upgrade instructions via the C Test 01/03/13 CC0003 - (Limited distribution) CC0006 - (Issue 2) SGD Firmware Upgrade instructions - activated clips CC0007 - (Issue 2) SGD Firmware Upgrade instructions un-activated clips DITECH FDIT001 - DI800UN VERSION COMPATIBILITY 03/10/07 DETECTIVE + FGAS FGAS0001-Cross Sensitivity 31/7/14 FGAS0002-Product Code Changes 16/11/16 GASFLAG FLAG-001 - Change of Power Supply Unit 30/9/11 GASMAN PG3001 - INSTRUMENT DIS-ASSEMBLY AND SOUNDER REMOVAL - 21/12/07 PG3002 - EXTERNAL FILTER - 07/02/08 PG3004 - ADVISORY NOTICE FOR GASMAN UNITS WITH NON-RECHARGEABLE BATTERIES 19/03/2010 PG3005 - Sound output test for Gasman 02/08/2010 PG3006 - Gasman replacement battery instructions 5/12/11 PG3007 - Gasman Red LED and Battery Charging Restart 21/07/2017 PG3008 - Gasman battery pad fitting PG3009 - Gasman Non-Rechargeable Battery Replacement 08/03/16 PG3010 - Gasman Error Codes PG3012 - Gasman CO2 two point calibration 13/06/2018 GASMASTER FGM2-001 - SOFTWARE UPGRADE - 10/03/08 FGM2-002 - GASMASTER BATTERIES - 27/04/08 FGM2-003 - Gasmaster Display Under-Range Fault (Issue 2) 4/7/12 FGM2-004 - Gasmaster (old style) Mains Fuse FGM2-005 - Gasmaster Power Supply Adjustment and Battery Charging (Issue 2) 07/02/13 FGM2-006 - Change of Display Moulding & Chassis design (04/10/13) FGM3-001 - Gasmaster III Service & Technical Notes (23/10/13) GAS-TEC (Obsolete Product) GAS5-001 - GAS-TEC USB LOCK UP - 14/05/10 GAS5-002 - GAS-TEC PROBE FILTER UPGRADE - 17/05/10 GAS5-003 - GAS-TEC V COIN CELL REPLACEMENT (Issue 2) - 24/10/12 GAS5-004 - Gas-Tec V Serial Number Programming Instructions 28/07/11 Page 1 of 6

GASEEKER (Obsolete Product) GASE001 - Calibration Safety Notice - 07/05/10 GASMONITOR FGMO001 - MODULE REVISION HISTORY - 14/02/07 FGMO001 (Issue 2) - MODULE REVISION HISTORY - 24/09/08 FGMO002 - POWER CARD IMPROVEMENT - 15/08/07 FGMO003 - INPUT CARD SOFTWARE UPGRADE - 24/09/08 FGMO004 - Gasmonitor Inhibit Module - 18/12/09 FGMO005 Gasmonitor AV Alarm fuse requirement 27/06/13 GAS-PRO Gas-Pro003 Gas-Pro Chargers & Communications Interfaces - 03/04/2014 Gas-Pro004 Gas-Pro firmware version compatibility - 03/06/2016 Gas-Pro005 Gas-Pro Dust Filter flow plate (Issue 2) - 29/06/2017 Gas-Pro008 Gas-Pro Battery Charging -27/06/2018 Gas-Pro009 Gas-Pro Ethanol Cross Calibration 9/7/2018 Gas-Pro010 - Tank-Pro Name Change 22/10/2018 GENERAL GEN001 - Chlorine alarm levels - 28/09/2007 GEN002 - Phosphine alarm levels - 28/09/2007 GEN003-87ESU new fan assembly - 07/11/07 GEN004 - Checkbox Cable Connections - 27/11/07 GEN005 - Gasman and Tetra 3 elastomer s - 29/11/07 GEN006 - Custodian rechargeable battery packs & Gasman II batteries 04/12/07 GEN007 - Autocalibrator Obsolescence 11/12/2007 GEN008 - Use of Quad Gas mixture - 14/12/07 GEN009 - Pellistor Mimic Module Obsolescence 10/03/2008 GEN010 - IEC61508 and SIL - 07/07/09 issue 2 GEN011 - Monitoring Gasses in ducts - 14/05/08 GEN012 - Use of Quad Gas mixture 1-14/12/07 GEN013 - Use of Quad Gas mixture 2-14/12/07 GEN014 - Silicone wrist bands10/09/08 GEN015 - Marine Approved Fixed Product Status Issue 2 20/09/10 GEN016 - Calibration of ETO & VO sensors 13/01/09 GEN017 - Ozone Detector Calibration Issue 2 22/6/2018 GEN018 - New date codes August 2014 01/08/14 Issue 2 GEN019 - Settings on ma output on 40/40 Flame detectors GEN020 - Oxygen Bump testing advisory GEN021 - Oxygen depletion in Helium Applications 04/11/10 GEN022 - Portable in-field functional testing 22/12/10 GEN023 - Portable zero stability 25/03/11 GEN024-20L cylinders capacity reduced to 12L 25/03/11 GEN025 - Custodian Status Change Notification 13/07/11 GEN026 - Checkbox windows 7 64_32 bit compatibility GEN027 - TPP Red Comms Cable 16/02/12 GEN028 - HCl sensor Tetra, Tetra 3 and Gasman February 2012 GEN029 - Notice of Obsolescence Eikon H2S UL approved version 02/03/12 GEN030 - SO2 (4S) and NH3 (NH3 3E 100 SE) Sensor cross sensitivity and inhibition guidance and warnings Tetra, T3 and Gasman 27/03/12 GEN031 - Checkbox USB Drivers (Windows XP) 26/03/2012 GEN032 - Checkbox USB Drivers (Windows 7) 26/03/2012 GEN033 - CO H2 Filtered sensor for Gasman and Tetra 3 27/03/2012 GEN034 - Eikon Obsolescence 26/11/2012 GEN035 - Portables Charger Update - 8/1/2013 GEN036 - Notice of Obsolescence (Nimbus) 18/02/2013 GEN037 - Alarm level change for Chlorine and Phosphine - 19/10/2007 - Was SEN006 GEN038 - HF Sensors Operating Temperature Limit - 31/10/2007 - Was SEN007 Page 2 of 6

GEN039 - Sensor Operation - 31/10/2007 - Was SEN008 GEN040 - Sensor Poisoning - 10/03/2008 - Was SEN09 GEN041 - Change from 300p to VQ21 Pellistor s - 11/07/2008 - Was SEN010 GEN042 - Max 250 Oxygen Sensor & Amplifier Modifications - 12/08/2008 - Was SEN011 GEN043 - VQ25 Pellistor Notice - 10/08/2010 - Was SEN014 GEN044 - Testing O2 sensors Issue 2 04/12/2013 - Was SEN015 GEN045 - Hydrogen Cyanide sensor front caps colour change - 23/11/2011 - Was SEN016 GEN046 - Sprint FGA Availability 21/06/2013 GEN047 - Notice of Obsolescence (DI-8 H2S) 01/07/2013 GEN048 - Launch of New Tango Gas Detection System 10/07/2013 GEN049 - Checkbox S-7 Error Resolution 13/09/2013 GEN050 - Notice of Obsolescence (Cellarsafe) 09/12/2013 GEN051 - Notice of Obsolescence (Gastec IV) 18/12/2013 GEN052 - Notice of Obsolescence (Gasmaster (Old)) 04/02/2014 GEN053 - MED Approval on Fixed Products - 14/04/14 GEN054 - Pellistor Correction factors - Fixed Detectors VQ21 Series Sensors VQ25 and VQ41 - issue 5 9/7//2018 GEN055 - Gas cylinder datasheet GEN056 - Notice of Pellistor Obsolescence GEN058 - Charging requirements for Crowcon portable products 14/03/2016 GEN059 - Notice regarding shipment of lithium batteries GEN061 - Control System Software GEN062 - Notice of Obsolescence (Checkbox IMH) GEN063 - Notice of Obsolescence (Tetra) GEN065 - PC Software for Portables Issue 2 12/6/2018 GEN066 - PC Communications Accessories for Portables Issue 2 12/6/2018 GEN067 - Product warranty periods GEN070 - IRmax and XgardIQ DTM and DD HART Files GEN071 - P90E Correction Factors for Triple Plus + and Detective + GEN072 - Bump Testing Equipment for Portables Issue 2 12/6/2018 GEN073 - Notice of Obsolescence (Crowcon Clip) GEN074 - Notice of Obsolescence (Ditech Modules) GEN075 - Notice of Obsolescence Txgard and Flamgard 29/1/18 GEN076 - Notice of Obsolescence - C2 29/1/18 GEN077 - Notice of Obsolescence - In-Line Power Supplies Gasman, T3 & Triple Plus+ 26/2/18 GEN078 - Bump Testing Requirements 12/6/2018 GEN079 - WEL Changes August 2018 GEN080 - Infra Red (IR) sensors calibration 9/7/2018 GEN082b - Generic Oxygen sensor testing in fresh air 30/07/2018 GEN083 - WEL Changes - Replacing Sensor Modules 17/09/2018 GEN084 - Notice of Obsolescence (TCgard) 01/10/2018 GEN085 - Notice of Obsolescence (IREX) 02/10/2018 GEN086 - Notice of Obsolescence (Hydra) 16/10/2018 GEN087 - Oxygen Sensor (7OX-V) Storage Shorting Link (19/11/18) IREX/IRMAX FSIR001 - IREX IR GAS DETECTOR TESTING - 06/11/09 FSIR002 - M20 - M20 CABLE GLAND FOR IREX GAS DETECTORS - 06/11/09 FSIR003 - IRMAX WATER INGRESS FSIR004 - IRMAX and IREX Cross calibration data (Issue 10) 10/03/16 FSIR005 - IRMAX Installation Notes FSIR006 - IRMAX HART communication information FSIR007 - IRMAX MODBUS communication information FSIR008 - IRMAX & IREX Certification FSIR009 - IRMAX Fault Diagnosis FSIR010 - IRMAX O-ring Seal FSIR011 - IRMAX Cleaning Precaution FSIR012 - IRMAX display ma feedback 26/11/12 FSIR013 - IRmax Pipe Mounting Kit & Sunshade Instructions 12/07/13 FSIR014 - IRmax to Vortex Connection 18/12/13 FSIR015 - IRmax Styrene - 15/04/14 Page 3 of 6

FSIR016 - IRmax PC Software 29/04/14 FSIR017 - IRmax Connected to PLC or DCS FSIR018 - IRMAX Dust Filter Accessory NIMBUS (Obsolete Product) FMIR001 - NIMBUS SUPPLY VOLTAGE - 05/07/07 FMIR002 - NIMBUS SOFTWARE - 29/11/07 FMIR003 - Nimbus PC Failing to write gas data. - 21/12/10 FMIR004 - Nimbus USB Adapter - 18/10/11 NOTICES OF OBSOLESCENCE GEN006 - Custodian rechargeable battery packs & Gasman II batteries 04/12/07 FMIRC001 - CIRRUS OBSOLESCENCE - 17/08/07 GEN009 - PELLISTOR MIMIC MODULE OBSOLESCENCE 10/03/08 SOLD001 - RED LINE OBSOLESCENCE 10/03/08 SEN012 - TXGARD-IS FIXED POINT GAS DETECTOR - 06/01/09 PT003 - TRIPLE PLUS OBSOLESCENCE - 12/01/10 PG2001 - GASMAN II OBSOLESCENCE - 12/01/10 SEN013 - DI 5/6 OBSOLESCENCE 23/07/10 TEL006 - LMD Notice of Obsolescence 20/04/11 GEN034 Eikon Obsolescence 26/11/2012 GEN047 - Notice of Obsolescence (DI-8 H2S) 01/07/2013 GEN050 - Notice of Obsolescence (Cellarsafe) 09/12/2013 GEN051 - Notice of Obsolescence (Gastec IV) 18/12/2013 GEN052 - Notice of Obsolescence (Gasmaster (Old)) 04/02/2014 GEN062 - Notice of Obsolescence (Checkbox IMH) GEN063 - Notice of Obsolescence (Tetra) GEN073 - Notice of Obsolescence (Crowcon Clip) GEN074 - Notice of Obsolescence (Ditech Modules) GEN075 - Notice of Obsolescence Txgard and Flamgard 29/1/18 GEN076 - Notice of Obsolescence - C2 29/1/18 GEN077 - Notice of Obsolescence - In-Line Power Supplies Gasman, T3 & Triple Plus+ 26/2/18 PANELSPRO PAN001 Panels Pro Configurations and Vortex Voting PORTABLESPRO PPRO_001 - Creating.csi images for PortablesPro and Gas-Pro Logo s 30/10/12 SENSORS (See General Technical Notes for sensor related Tech Notes) SEN012 - TXGARD-IS FIXED-POINT GAS DETECTOR - 06/01/09 SEN013 - DI 5/6 OBSOLESCENCE 23/07/10 T4 T4-001 - New T4 Display Screen T4-002 - T4 Functional Check T4-003 (Issue 2) - T4 firmware & Portables Pro Software versions TELEGAN TEL001 - COMPATIBILITY OF SPRINT TO SPRINTER - 23/10/07 TEL002 - SPRINT 2000 SERVICING - 07/04/09 TEL003 - SERVICE CENTRE UPGRADE V1.8 TEL004-5FO SEN20076 sensor life improvement 25/03/11 TEL005 - Spygas CO Calibration 12/04/11 TEL006 - LMD Notice of Obsolescence 20/04/11 TEL007 - UK to EU Hydrogen Cylinder Upgrade Procedure 01/06/11 TEL008 - Italian Sprint Efficiency Calculation Correction 28/06/11 TEL010 - Sprint 1000-2000XT - 3000 Charging 29/07/11 TEL011 - Sprint Service Centre (Italian Fuels Update) 20/02/2012 TEL012 - Sprint PC Lite (Italian Fuels Update) 21/02/2012 Page 4 of 6

TEL013 - BG evo3 Guidance Notes - Not for general release 10/12/13 TEL014 - BG EVO3 Technical Note for British Gas Only Not for general release 27/03/14 TEL015 Sprint EVO Sprint EVO Pump Tool Instructions Not for general release 27/03/14 TEL016 Sprint EVO Leak Detector 13/04/15 TEL019 - Sprint NetHE High Efficient Measurement 02/03/17 TETRA (Obsolete Product) PTETRA001 - ACTISYS IRDA DEVICE 23/08/07 PTETRA002 - GASKET AND FILTER 28/09/07 PTETRA003 - PUMP REPLACEMENTS 07/02/08 PTETRA004 - ALARM OPERATION 15/08/08 PTETRA005 - New LCD 16/02/11 PTETRA006 - New Charger Bung 06/05/11 PTETRA007 - Tetra embedded code upgrade instructions Issue 2 - April 2012 PTETRA008 - Tetra configuration instructions 06/07/11 PTETRA009 - Battery change, T rating drops from T4 to T3 10/10/12 PTETRA010 - Tetra Filter Plate, units fitted with HF or HCL sensors 07/07/2017 PTETRA011 Tetra Change to CO2 Spare Sensor Module 28/06/2018 TETRA 3 PMINTET001 - CHARGER UPGRADE - 28/09/07 PMINTET002 - BATTERY CHARGE REMAINING INDICATOR 31/10/07 PMINTET003 - LCD REPLACEMENT 31/10/07 PMINTET004 - ASPIRATOR PLATE FOR 2-3 YEAR OXYGEN UNITS 17/01/08 PMINTET005 - UNLOCKING THE HYBRID 10/09/08 PMINTET007 - NEW HYBRID DESIGN START UP SEQUENCE 26/03/10 PMINTET008 - New LCD 16/02/11 PMINTET009 - Tetra 3 configure instructions 23/06/11 PMINTET010 - Tetra 3 flasher software installation instructions 23/06/11 PMINTET011 - Tetra 3 Startup missing I module resolution 30/11/12 PMINTET013 - Tetra 3 Toxic sensor bay position 10/11/2015 PMINTET015 - Tetra 3 missing i-module failures 11/10/16 TXGARD IS / IS + FMH001 - TXGARD IS + PERSONALITY MODULES 23/08/07 FMH002 - TXGARD IS+ UL 29/03/10 FMH004 - TXGARD IS CO and H2S sensor change 06/11/2015 TRIPLE PLUS + PT001 - PUMP REPLACEMENT - 17/07/08 PT002 - BATTERY LIFE - 15/07/09 PT003 - TRIPLE PLUS OBSOLESCENCE - 12/01/10 PT004 - New LCD - 16/02/11 PT005 - Triple Plus + and Detective + Volume IR sensors Calibration requirement - 14/12/11 PT006 Triple Plus + LIBRA Characteristic s July 2012 PT011 - TriplePlus+ & Detective+ - Infrared (IR) Acetylene sensor obsolete 12/05/17 PT012 - TriplePlus+ Leather Carry Case for Hazardous Areas 04/06/18 VORTEX FVOR001 - EMBEDDED SOFTWARE-24/09/08 FVOR002 Relay logic programming error V3.0.0 VortexPC 01/02/2014 FVOR003 - Vortex with the new I.S. smoke detector Hochiki SLR-E-IS 15/6/15 FVOR004 - New Power Supply (Wall Mount Panel) - Fitting Instructions 21/05/18 XGARD FXG001 - XGARD WEATHERPROOF COVER - 03/10/07 FXG002 - XGARD TYPE 1 JUNCTION BOX - 4/12/07 FXG003 - XGARD TYPE 1 PHOSGENE CALIBRATION - 07/01/08 FXG004 - XGARD IR TECHNICAL SPECIFICATION CO2 2% -14/02/08 FXG005 - XGARD IR TECHNICAL SPECIFICATION CO2 5% - 14/02/08 Page 5 of 6

FXG006 - XGARD TYPE 5 VINYL CHLORIDE MONOMER - 17/12/08 FXG007 - XGARD TYPE 1 HYDROGEN FLOURIDE TECHNICAL Issue 2 01/12/2010 FXG008 - XGARD TYPE 1 & TYPE 2 OXYGEN SENSOR LABEL 12/02/09 FXG009 - XGARD IR ETHANOL TECHNICAL SPECIFICATION 04/03/09 FXG010 - XGARD IR LPG TECHNICAL SPECIFICATION 19/10/09 FXG011 - XGARD IR HAXANE TECHNICAL SPECIFICATION 19/10/09 FXG012 - XGARD TYPE 1&2 CO TECHNICAL SPECIFICATION 26/01/10 FXG013 - XGARD TYPE 5 DRIFTING -BALANCING Issue 2-08/08/11 FXG014 - XGARD TYPE 1 CHLORINE TECHNICAL ISSUE 1-01/12/10 FXG015 - XGARD HYGROGEN CHLORIDE TECHNICAL ISSUE 1-01/12/10 FXG016 - XGARD FLUORINE TECHNICAL ISSUE 1-01/12/10 FXG017 - XGARD HYDROGEN SULPHIDE (ALL RANGES UP TO 50PPM) - 01/12/10 FXG018 - XGARD HYDROGEN SULPHIDE (ALL RANGES 0-100PPM AND ABOVE) - 01/12/10 FXG019 - XGARD OZONE TECHNICAL ISSUE 1-01/12/10 FXG020 - XGARD OXYGEN TECHNICAL ISSUE 1-01/12/10 FXG021 - XGARD NITROGEN DIOXIDE TECHNICAL ISSUE 1-01/12/10 FXG022 - XGARD NITRIC OXIDE TECHNICAL ISSUE 1-01/12/10 FXG023 - XGARD GEMANE TECHNICAL ISSUE 1-01/12/10 FXG024 - XGARD HYDROGEN TECHNICAL ISSUE 1-01/12/10 FXG025 - XGARD VOLATILE ORGANICS TECHNICAL ISSUE 1-01/12/10 FXG026 - XGARD CHLORINE (0-100PPM) TECHNICAL ISSUE 1-01/12/10 FXG027 - XGARD HYDROGEN CYANIDE TECHNICAL ISSUE 1-01/12/10 FXG028 - XGARD AMMONIA 0-100PPM TECHNICAL ISSUE 1-01/12/10 FXG029 - XGARD AMMONIA 250-1000PPM TECHNICAL ISSUE 1-01/12/10 FXG030 - XGARD ARSINE TECHNICAL ISSUE 1-01/12/10 FXG031 - XGARD TYPE 1 CHLORINE DIOXIDE TECHNICAL ISSUE 1-01/12/10 FXG032 - XGARD TYPE 1 SILANE TECHNICAL ISSUE 1-01/12/10 FXG033 - XGARD TYPE 1 SULPHUR DIOXIDE TECHNICAL ISSUE 1-01/12/10 FXG034 - XGARD TYPE 1 PHOSPHINE TECHNICAL ISSUE 1-01/12/10 FXG035 - XGARD TYPE 1 & 2 TEMPERATURE SPECIFICATIONS ISSUE 1-22/08/11 FXG036 - XGARD TYPE 5 for Ethylene Dichloride (EDC) 08/06/12 FXG037 - XGARD Type 4 wiring details to a Flamgard Plus (Issue 2) 12/02/13 FXG038 Not released FXG039 - XGARD Sensor, Resistor Value and Calibration Data Sheet 03/12/14 XGARDIR FXIR013 - XGARDIR PRODUCT ADVISORY NOTICE: IR SENSOR MODULE FAILURE - 08/07/10 FXIR014 - FXIR-014 Xgard IR Amplifier Balancing and zeroing 02/01/18 XGARDIQ FXIQ001 - XgardIQ ATEX and IECEx Certification 14/09/2016 FXIQ002 - XgardIQ Wiring Tech Note 14/10/2016 Page 6 of 6