Agent Tanks PCL PCL PCL PCL - 600

Similar documents
ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

Data/ Specification Sheet

PriceList Category PartNbr Part Description Weight (l MSRP

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Types of Detection. Fusible Link Detection - Most Common

Industrial Dry Chemical Fire Suppression System

Badger Universal Control Head

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

CORE Protection Fire System Specification

FM-200 In-Cabinet Series

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

R-102 RESTAURANT FIRE SUPPRESSION SYSTEM

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

THE GUARDIAN III OWNER S MANUAL. Stops Rangetop Fires Instantly. For Installation, Operation and Maintenance

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

TotalPac X Firecycle III Preaction Double interlock system

Refrigerant Recovery Machine. Model No Operating Manual

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Control Panel For Water Wash Hoods AM2

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

TotalPac X Single interlock SUREFIRE system

Specification/ Data Sheet

NOTE: THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT AN OFFICIAL BID DOCUMENT.

Kiddie After Discharge Clean-Up

Twin-Agent Fire Fighting/Securing Systems Specifications

Kitchen Knight Suppression System Installation Manual READ ONLINE

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

FIRE EQUIPMENT & SAFETY SUPPLIES

The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Kitchen Fire Suppression Systems Post-Event Analysis

MANUAL RESET ALARM RELEASE

POWER SOURCES MODEL NO. DESCRIPTION PRICE

Ventless Operation Supplement GBF-D-VH

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

PRODUCT MANAGEMENT BULLETIN# 171b

Electric Automatic Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Frontier. Self Contained Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (09-99)

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Basic Vehicle Fire Protection Manual

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

INSTALLATION INSTRUCTIONS PT-A HEAT/AC STANDARD KIT FORD E-SERIES VANS

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Badger Heat Detector Links and Housing Kits

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Used Fluid Handling Portable Used Oil Gravity Drains

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Powers Controls Low Temperature Detection Thermostat

MANUAL RESET ALARM RELEASE

The D1000. Installation and Service Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Extinguishers. Commercial Industrial High rise buildings

Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea

Advanced Fire Training Props Boulder, CO

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Ventless Donut Center. Insider SUPPORT SUPPLÉMENT TECHNIQUE. The #1 Source for Donut and Bakery Equipment

CHECKFIRE 210 Detection and Actuation System

GEMINI TM DYNACONTROL TM HOSES Automatic & Manual Versions FOR DYNAMELT & DYNAMINI TM ADHESIVE APPLICATION SYSTEMS

IMAGE V. Parts and Service Manual

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

D14 & D18 Upright Vacuum

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

This unit is superb for commercial applications where soft water is required 100% of the time.

Installation Manual CARBONATOR With Plain-Water Booster

CUTMASTER Strip Cutting Machine

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Service Bulletin No. 2930

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

FILTRATION SYSTEM MODEL: FILTER - 5 MULTI-SHIFTER, INC. P.O. BOX CHARLOTTE, N.C TEL#: FAX#:

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

SHIP TO ADDRESS: CUSTOM IMPRINTED GREEN 1 3/8" LPI-CIVC1 $ LB DRY CHEMICAL GAUGE LPI-195 $1.59

ORDER GUIDE Authorised Reseller

Chapter 26 FIRE PROTECTION

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Replacement Parts List For Models COS-20G

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

WORMALD INTERNATIONAL ELECTRIC VALVE ACTUATOR

MANUAL RESET ALARM RELEASE BOX

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Smoke Vent with Manual Winch. Installation, Operation and Maintenance

Hospitals and Major Medical Centers

Transcription:

Components Pg 2-1 Agent Tanks PCL - 160 PCL - 300 PCL - 460 PCL - 600 Model No. Diameter Height to top of valve Height with control head Height to valve outlet Weight PCL - 160 8.00 in. 17.65 in. 23.50 in. 15.44 in. 34 lbs. PCL - 300 8.00 in. 25.06 in. 30.81 in. 22.75 in. 53 lbs. PCL - 460 10.00 in. 25.06 in. 30.81 in. 22.75 in. 83 lbs. PCL - 600 10.00 in. 35.81 in. 41.56 in. 33.50 in. 108 lbs.

Components Agent Tanks The tanks are manufactured, tested, and marked in accordance with DOT 4BW225 Tested at 3X working pressure (675psi) Meets DOT Requirements No Burst Test Required

Components Agent Tanks The manufacture date is stamped on the neck. 12 year hydro-test

Agent Tanks Agent Tanks The tanks are delivered filled with the wet chemical extinguishing agent and charged to 225 psi at 70 o F (1551 kpa @ 21 o C).

Agent Tanks PCL - 160 The PCL-160 tank has a maximum flow point capacity of 5.

Agent Tanks PCL - 300 The PCL-300 tank has a maximum flow point capacity of 10.

Agent Tanks PCL - 460 The PCL-460 tank has a maximum flow point capacity of 14 or 15.

Agent Tanks PCL - 600 The PCL-600 tank has a maximum flow point capacity of 19 or 20.

Agent Tank Valve Valve assembly has internal regulator to reduce discharge pressure to 100 psi (689.5 kpa). PISTON TYPE VALVE ASSEMBLY INTERNAL REGULATOR

Agent Tank Valve The valve is a pressure sealed poppet type valve.

Agent Tank Valve: Non-Actuated In the non-actuated state, the piston and valve stem are sealed shut by both the internal pressure and the conical spring seated against the piston. CONICAL SPRING PISTON VALVE STEM

Agent Tank Valve: Actuated When actuated, cartridge pressure from the Control Head, forces the piston and valve stem down Regulator outlet ½ in. NPTF. PISTON VALVE STEM

Agent Tank Valve: Actuated The tank contents are then discharged at regulated pressure of 100 psi. WET AGENT

System Recharge Materials There are various components available for system recharge. Wet valve rebuild kit Regulator rebuild kit VT-1 wet valve tool Extinguishing agent

Wet Valve Seal Rebuild Kit The wet valve seal rebuild kit is used to refurbish the tank valve after each system discharge.

VT-1 Wet Valve Tool The VT-1 wet valve tool is designed to facilitate the valve rebuilding. It should be used to hold the wet valve piston while unscrewing the cap and stem assembly.

Extinguishing Agent Potassium Carbonate based solution Extremely effective for all types of kitchen fires. Recharge Pails Available in 1.6 gallon, (RL-160) 3.0 gallon, (RL-300) 12 year in-service life No low temperature storage limitation Agent MSDS available. Cautions when handling liquid agent solution eye protection, flush procedures for skin contact, rubber gloves, electrically conductive, etc.

Tank Mounting Brackets PCL - 160 PCL - 300 PCL - 460 Mounted with the MB-15 mounting bracket.

Tank Mounting Brackets PCL - 600 Mounted with the MB-1 mounting bracket.

Control Heads The heart of the system is the Control Head, whether mechanical or electrical.

Control Heads In all cases the control head will be the system interface between - Actuation of the agent tanks The detection system The remote mechanical pull stations Gas shut off valves Contractor-supplied devices, and alarms.

System Review

Control Heads In operation, a pilot cartridge is installed in the cartridge receiver. A cam arm, captured by the slide plate, holds a cam next to the puncture pin. CAM ARM PILOT CARTRIDGE (16 gram only)

Control Heads The slide plate is released by: Pulling a pull station or separation of a fuse link detector. The spring pulls the slide plate back operating the cam arm to puncture the cartridge and actuating the system. SLIDE PLATE

Control Heads There are two basic types of Control Heads: Mechanical or Electrical ELECTRICAL MECHANICAL

Control Heads Each type is available with: Local Actuation or No Local Actuation Attaches directly to PCL tank valve or Remotely mounted. NO LOCAL ACTUATION NOTE: Old flag style cover plates MUST NOT be used on newer style control boxes. LOCAL ACTUATION

Control Heads The electrical models are available: 120VAC 24VDC 24 VDC 120 VAC

Mechanical Control Heads The MCH3/NMCH3 Mechanical Control Head supports: Fusible link detection Remote mechanical pull stations Mechanical or electrical gas shutoff valves

ECH3 Electrical Control Heads The ECH3 Electrical Control Head supports: Thermal detection Remote mechanical pull stations Electrical gas shutoff valves

ECH3 Electrical Control Heads It s important to note that the ECH3 Control Head does not support fusible link detection systems.

ECH3 Electrical Control Heads A miniature doublepole, double-throw switch is included with the ECH3 Control Head. DOUBLE-POLE, DOUBLE-THROW MINIATURE ELECTRIC SWITCH

ECH3 Electrical Control Heads The EHC3 Control Head is available in either 120VAC or 24VDC 120 VAC All options offer the same release within the Control Head

Control Head Mechanics

EN-S Enclosure PCL-160, 300 and 460 tanks can also be mounted in an EN-S Enclosure. (No Control Head)

EN-MCU3 Enclosure The PCL-160,300 and 460 tanks can also be mounted inside an EN-MCU3 SS Enclosure. No bracket required.

EN-MCU3 Enclosure

EN-MCU3 Enclosure This stainless steel enclosure can be used when the owner wishes that the fire suppression system match the kitchen decor.

EN-S Enclosure This enclosure is used when additional tanks are required when matching to the kitchen decor.

Control Heads Each of the Control Heads can actuate up to five tanks by mounting the control head remotely and connecting to the tanks with ¼ inch actuation line.

MB-P2 Mounting Bracket Control Head mounted remotely requires the Control Head Mounting Bracket MB-P2. Caution: A control head screwed to the wall could warp the control head, not allowing the mechanism to actuate.

Pneumatic Actuating Cylinder PAC-10 If more than five tanks require actuation, a PAC-10 would be required.

Pneumatic Actuating Cylinder PAC-10 A PAC-10 is nitrogen pressurized to 350 psi at 70 o F (2413 kpa @ 21 o C). and comes packaged with its own wallmounting bracket.

Pneumatic Actuating Cylinder PAC-10 A PAC-10 assembly is a pneumatic actuation cylinder that can actuate up to a maximum of 10 agent tanks simultaneously using one of the four control head models.

Detection System The detection system can be either mechanical or electrical by use of the fuse link method for mechanical systems or thermal for electrical systems

Mechanical Fusible Link ML Style Link The fuse links are designed to separate at specific temperatures which releases the tension in the fuse link line thus actuating the suppression system.

Mechanical Fusible Link ML Style Link The fuse link temperature ratings are available in 165, 212, 280, 360, 450, and 500 o F. (73.8, 100, 137.8, 182.2, 232.2, & 260 o C)

Mechanical Fusible Link The temperature rating is stamped on the links along with the date of manufacturing. Pyro-Chem recommends fusible links be replaced every six months. TEMPERATURE RATING MANUFACTURED DATE

Mechanical Detection System The mechanical detection system line is connected to the Control Head at the fusible link line ratchet wheel. FUSIBLE LINE RATCHET WHEEL

Mechanical Detection System Detector Brackets Two detection brackets are available. FLK-1 FLK-1A

Mechanical Detection System FLK-1A Bracket Is an 8-inch (203 mm) steel bracket. It also comes packaged with two ½-inch EMT connectors, two cable crimps, and two S-hooks.

Mechanical Detection System FLK-1 Bracket Is a 10-inch (254 mm) steel bracket. It comes packaged with two ½-inch EMT connectors, two cable crimps, and two S-hooks.

Fusible Link Hangar FLH-1 Hanger Both brackets can use the FLH-1 fusible link hangar accessory to simplify link installation. FLH-1 FUSIBLE LINK HANGAR

Fusible Link Hangar FLH-1 Hanger The FLH-1 allows the installer to attach fusible links without the need to cut wire or make crimping loops.

Electrical Detection System Solenoid Monitor The electrical detection line is interconnected to the Solenoid Monitor and ECH3 Control Head. Also used as a reset relay for the electric gas valve. MINIATURE ELECTRICAL SWITCH

Wire Rope The 1/16 stainless steel wire rope is used with: Mechanical detection system Remote pull stations Mechanical gas valve shutoff line The Wire Rope is available in 50 and 500 foot rolls.

1/2-Inch EMT Conduit & Fittings Pyro-Chem does not supply the ½ inch EMT conduit required for the detection, remote pull station, gas valve shutoff, or contractor-supplied devices. Nor any electrical type boxes that may be required to complete an installation.

Restaurant Systems Projects Flexible Conduit Flexible Conduit 500 ft. (152m) rolls Part No. 434525 Sold with 500 ft. (152m) wire rope PN 435959

Mechanical Pull Station RPS-M Pull Station The RPS-M remote mechanical pull station attaches to a standard 4 inch square electrical box.

Mechanical Pull Station RPS-M Pull Station Works with all the Control Heads.

Mechanical Pull Station RPS-M Pull Station Pull Station attaches to latching arm at the control head. RING PIN HOLE LATCHING ARM MANUAL PULL CABLE HOLE

Gas Shutoff Line Gas Valves Both mechanical and electrical gas shutoff valves are available to shutdown the flow of fuel to the appliances during system actuation

Mechanical Gas Shutoff Line Gas Valves The mechanical gas shutoff valves is rated for both natural and LP gas and is available in ¾, 1, 1 ¼, 1 ½, 2, 2 ½ and 3 inch sizes.

Mechanical Gas Shutoff Line Gas Valves The mechanical gas shutoff line is connected to the Control Head at the gas valve ratchet wheel. GAS VALVE LINE RATCHET WHEEL

Electrical Gas Shutoff Line Gas Valves The electrical gas shutoff valves is rated for both natural and LP gas also and is available in ¾, 1, 1 ¼, 1 ½, 2, 2 ½ and 3 inch sizes.

Electrical Gas Shutoff Line Gas Valves The electrical gas shutoff valve line is wired through either a Solenoid Monitor (SM-120) or a UL listed manual reset relay.

Solenoid Monitor Two models are available. The SM-120 or SM-24. They are used with the ECH3 120VAC and 24VDC Electrical Control Heads respectively.

Solenoid Monitor The solenoid monitors have two sets of normally open and normally closed dry contacts. It mounts directly to a three-gang wall outlet box.

Mechanical Directional Changes Corner Pulleys All directional changes for the fusible link detection line, manual pull station lines, and the mechanical gas valve shutoff lines must be made with corner pulleys, either the SBP-1 or the CBP-1.

TP-1 Pulley Tee Pulley Tee Model TP-1 is available to connect two remote mechanical pull stations or two mechanical gas shutoff valve when needed.

Electrical Switches Electrical switches are available in one, two, three, and four switch kits. They are rated at: 21 amps each, 1 horsepower @ 125, 250, 277 VAC 2 horsepower @ 250, 277 VAC.

Agent Distribution Piping The agent distribution piping required must be Schedule 40 Stainless steel Chrome plated or Black pipe and fittings The installer must furnish the pipe and fittings.

Agent Distribution Piping Galvanized pipe and fittings are not allowed.

Bulkhead Penetration Quick-seal adapters are available for bulkhead penetration, usually in the hood area. They are available in 3/8 and 1/2 sizes.

Restaurant Systems Projects New - Flexible Hose for Kitchen Knight II Placed anywhere behind the appliances, below hazard surface area Can be used for any type of castered UL appliance within system as long as it is located behind the appliance

Kitchen Knight II Nozzles 1H 1L 2H 2L 2D Nozzles

Kitchen Knight II Nozzles The nozzle type is stamped on the nozzle body. 1H 2D 2H 2L 1L NOZZLE STAMPING

Kitchen Knight II Nozzles All nozzles have a specific flow point value and are supplied with blow-off caps to prevent clogging. BLOW-OFF CAP

Nozzle Swivel Adaptor A swivel adaptor for all of the nozzles is available. It rotates the nozzle approximately 30 degrees in all direction.

Questions On the Components Section of