PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

Similar documents
Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Operating Instructions Edition 02/2007

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Operating Instructions SIPLUS CMS4000 MCN11. Preface 1. Product Overview 2 SIPLUS CMS4000. Installation 3. Media Converter Node (MCN11) Wiring 4

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

COMPACT FLAME CONTROLLER CFC 2000

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

T3/E3 Fiber Optic Line Drivers

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

COMPACT FLAME CONTROLLER CFC 1000

4120 Fire Alarm Network Reference

EOTec 2C32 Installation Guide

G4 Pulsed Fiber Laser

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OPTIBAR DP 7060 Supplementary Instructions

Product Information to the manual

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Cabinet design and EMC SINAMICS. SINAMICS G130 Cabinet design and EMC. Safety information 1. General. Basic information about EMC 3

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Isolated Thermocouple Module

G4 Pulsed Fiber Laser

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

INSTRUCTION & SERVICE MANUAL

Laser Distance Sensor Type M Analog-Output

Important Safety Notice

Model 144H. Product Data Sheet , Rev DB February Content

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Model 144H. Product Data Sheet , Rev DB February Content

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Engineering Guideline. pac- Carriers Type Universal

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions

DESCRIPTION. 42 mm. 125 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

C-Bus Four Channel General Input Unit Installation Instructions

Operating Instructions

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

VERSAFLOW VORTEX Supplementary instructions

Technical Data. Dimensions

AO Annunciator Module

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Functional Safety Manual June pointek CLS500/LC500

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

4-Channel Contact Closure Fiber Link Card System

Technical Data. Dimensions

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

OPTIBAR P 1010/2010 C Supplementary instructions

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Control and Indicating Equipment

Four channel video link For low cost video transmission

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

Inductive slot sensor

OOH740, OOHC740 Automatic fire detectors

REA 105 Arc Protection Module. Operator s Manual

Technical Data. Dimensions

AUGUST 2016 CONTENTS:

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Explosion Protection Enclosure with integrated measuring system

Audible warning devices for external alarm

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Operating Manual MS220DA

4 Channel Contact Closure SFP DIN Fiber Link System

Technical Data. Dimensions

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Gas cylinder scale Model GCS-1

Call stations and extensions

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

C-Bus Four Channel Analogue Output Unit Installation Instructions

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Original operating instructions Safety switch with guard locking AC901S AC902S

Transcription:

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Operating Instructions Introduction 1 Components of the product 2 Functional description 3 Network topology 4 Commissioning 5 Help with problems during operation 6 Technical data 7 Approvals and certificates 8 04/2016 C79000-G8976-C122-07

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY Document order number: C79000-G8976-C122 P 04/2016 Subject to change Copyright Siemens AG 2009-2016. All rights reserved

Table of contents 1 Introduction... 5 2 Components of the product... 7 3 Functional description... 9 3.1 Interfaces... 9 3.2 Opto-electrical signal conversion and signal regeneration... 9 3.3 Supported FO fiber types... 10 3.4 Displays... 10 3.5 Operator controls... 12 4 Network topology... 13 4.1 Optical bus... 13 4.2 Integration of long FO cable runs... 14 4.3 Integrating RS-485 segments... 15 5 Commissioning... 17 5.1 Procedure for commissioning... 20 5.2 Installation... 20 6 Help with problems during operation... 27 6.1 Help with problems during operation... 27 7 Technical data... 29 8 Approvals and certificates... 33 8.1 Notes on the CE mark... 33 Operating Instructions, 04/2016, C79000-G8976-C122-07 3

Table of contents 4 Operating Instructions, 04/2016, C79000-G8976-C122-07

Introduction 1 The PROFIBUS OBT (Optical Bus Terminal) it is a network component used in optical PROFIBUS DP fieldbus networks. It allows the connection of either a single device without an integrated optical interface or an RS-485 segment to the optical PROFIBUS DP. The following figure shows an example of a configuration. Image 1-1 Example of an optical PROFIBUS DP configuration Operating Instructions, 04/2016, C79000-G8976-C122-07 5

Introduction Connections The connection between the individual bus nodes takes the form of an optical bus with twofiber plastic fiber-optic cables (plastic fiber-optic cables are also known as POF, Polymer Optical Fiber) or PCF fiber-optic cables (PCF = Polymer Cladded Fiber, synonymous with HCS1 fiber-optic cable). Since fiber-optic cables (FO cable) are completely insensitive to EMC interference, complex grounding concepts and protection measures are unnecessary. This also applies to the laying of a equipotential bonding cables. Due to be opto-electronic conversion, there is automatically electrical isolation so that potential differences as can occur in extensive plants are no longer noticed. 1) HCS is a registered trademark of Spectran Speciality Optics and stands for "Hard Polymer Cladded Silica Fiber". Sensitivity Just as the FO cable is insensitive to EMC interference, an FO cable also emits no electromagnetic waves into its environment. Sensitive electronic devices located in the vicinity of the fiber-optic cable therefore need no additional protection or suppression measures. Power supply The OBT requires an operating power supply of 24 VDC that is connected via two screw terminals. Operating state LEDs signal the current operating state and any problems affecting operation. Mechanical construction The mechanical construction consists of a compact plastic housing that can be mounted either on a DIN rail or any flat surface. 6 Operating Instructions, 04/2016, C79000-G8976-C122-07

Components of the product 2 Supplied 1 x PROFIBUS OBT 1 x Operating instructions (Compact) A5E03345735-01 Not supplied Plastic fiber-optic cables, sold in meters Assembly tool for fiber-optic cable connectors Operating Instructions for the PROFIBUS OBT Fiber-optic cable connectors Operating Instructions, 04/2016, C79000-G8976-C122-07 7

Components of the product 8 Operating Instructions, 04/2016, C79000-G8976-C122-07

Functional description 3 The OBT is a repeater with 3 channels. 3.1 Interfaces The OBT has the following interfaces for connection of PROFIBUS DP segments: Channel 1 (CH1) is an electrical RS-485 interface. It is designed as a 9-pin D-sub female connector. A PROFIBUS DP node or a PC, PG, OP or an RS-485 segment can be connected to the OBT via this channel. The copper segment should be kept as short as possible since this can couple in disturbances into the optical PROFIBUS DP. Channel 2 (CH2) and channel 3 (CH3) are optical interfaces. These are designed as duplex female connectors. The end a two-fiber plastic or PCF fiber-optic cable fitted with two simplex male connectors is connected to each of these duplex female connectors. The OBT also has a 3-pin terminal for connection of the 24 V power supply and, if necessary, a ground cable. 3.2 Opto-electrical signal conversion and signal regeneration The OBT converts the RS-485 level received at channel 1 into an optical signal level that is output via channels 2 and channel 3. Signals received at channel 2 or 3 are converted to electrical signals and output on channel 1 as an electrical signal they are then converted into an optical signal again and output on the other optical channel. There is no echo on the receive channel; in other words, received signals are not sent back on the same channel. The OBT regenerates the signals in amplitude and time. This makes it possible to cascade up to 126 modules in an optical bus. The cascading depth is simply limited by the monitoring times of the connected devices. The latency per OBT is 6 bit times. Operating Instructions, 04/2016, C79000-G8976-C122-07 9

Functional description 3.3 Supported FO fiber types 3.3 Supported FO fiber types The OBT supports the fiber types listed in the following table: Table 3-1 Achievable FO cable distance between the two devices on optical PROFIBUS DP Fiber type Plastic FO cable 980/1000 μm with 2 fibers and max. max. 200 db/km cable attenuation PCF FO cable 200/230 μm with 2 fibers and max. max. 10 db/km cable attenuation Link length between 2 devices 0.1 to 50 meters 0 to 300 meters The specified link length between the devices assumes that the partner devices use the same optical components as the OBT. This is, for example, the case with the IM 153 2 FO and IM 467 FO. The transmission speed is not dependent on the fiber type used or the cable length. This can be up to 12 Mbps. The following accessories are available: Plastic fiber-optic cable (sold in meters), connectors/polishing set and the assembly tool for plastic fiber-optic cable The plastic fiber-optic cables do not have connectors fitted. The plastic simplex connectors can be fitted easily on site with the available tools. PCF FO cable (preassembled) PCF cables with 4 PCF simplex connectors fitted are available in fixed lengths. 3.4 Displays The OBT has 4 LEDs to display the operating state. L+ 24 V (green) not lit: flashes: lit green: Power supply missing or internal power supply is defective or shortcircuited Power supply present, transmission speed not yet set Transmission speed set, power supply functioning correctly 10 Operating Instructions, 04/2016, C79000-G8976-C122-07

Functional description 3.4 Displays CH1, CH2, CH3 (channel 1 to 3, yellow) not lit: lit yellow: Data is not being received Data is being received Image 3-1 LEDs on the front panel Operating Instructions, 04/2016, C79000-G8976-C122-07 11

Functional description 3.5 Operator controls 3.5 Operator controls The OBT itself does not have any controls. The only point to remember is that the PROFIBUS connecting cable connected to channel 1 (does not ship with product) needs to be terminated at both ends. 12 Operating Instructions, 04/2016, C79000-G8976-C122-07

Network topology 4 4.1 Optical bus Along with other SIMATIC devices such as the IM 153 2 FO or IM 467 FO, OBTs are connected to optical PROFIBUS DP to form an optical bus. PROFIBUS DP bus nodes with an RS-485 interface are connected to channel 1 of the OBT via bus connectors and a PROFIBUS bus cable. The bus segment must be terminated at both ends. The OBT can be used at any point on the optical bus. If it is used at the start or end, the unused optical channel must remain closed with the rubber plug. This prevents contamination of the optical elements and disturbances caused by incident light. The connection on an optical bus is made using two-fiber plastic FO cable (max length 50 m) or PCF FO cable (max. length 300 m). The FO cables have two simplex connectors fitted at both ends. The FO connection between two devices is established by the optical transmitter of one device being connected to the optical receiver of the other device via a fiber, while the optical receiver of the first device is connected to the optical transmitter of the other (crossover cable). If an OBT or a fiber-optic cable fails, the network is split into two separate networks. Depending on the location of the problem, devices are no longer accessible. Note If problems are detected on the electrical interface, there is a segmentation, in other words, the frames are not forwarded. The segmentation is canceled when the problem has been eliminated. In this case, it is assumed that a minimum number of error-free frames were received on the electrical channel. The segmentation is also canceled when no frames are received for at least 1 second. In this case, it is assumed that unplugging the PROFIBUS connector caused problems and that there are no more nodes on the electrical channel. The OBT does not support the establishment of single-fiber rings or redundant ring structures. Operating Instructions, 04/2016, C79000-G8976-C122-07 13

Network topology 4.2 Integration of long FO cable runs 4.2 Integration of long FO cable runs The maximum permitted length of PCF FO cable with the OBT is 300 m. If longer FO links or other FO cable types, for example glass graded index fibers or monomode fibers are necessary, they can be used by combining OBTs with OLMs (Optical Link Module). In this situation, the OBT is connected electrically with the OLM (OBT/CH 1 to OLM/CH 1) and the OLM is connected to the long FO cable link. At the end of the FO cable link, the combination is reversed with a second OLM/OBT pair. Image 4-1 Example of covering longer FO links with OBTs and OLMs The maximum permitted transmission speed and the type and maximum length of the FO cable link is decided by the OLM type. 14 Operating Instructions, 04/2016, C79000-G8976-C122-07

Network topology 4.3 Integrating RS-485 segments 4.3 Integrating RS-485 segments The OBT allows the attachment of a PROFIBUS RS-485 segment. Image 4-2 Example of the integration of RS-485 segments Operating Instructions, 04/2016, C79000-G8976-C122-07 15

Network topology 4.3 Integrating RS-485 segments 16 Operating Instructions, 04/2016, C79000-G8976-C122-07

Commissioning 5 Note Use the PROFIBUS OBT only as intended in these Operating Instructions. Note Pay particular attention to all warnings and notices relevant to safety. WARNING Operate the PROFIBUS OBT only with safety extra-low voltage complying with IEC 950 / EN 60 950/VDE 0805 of maximum +28.8 V (typically +24 V). The power source must meet the requirements of the UL/CSA approval for NEC Class 2 according to the National Electrical Code (r) (ANSI / NFPA 70). Note Never look directly into the opening of the optical transmission diode. The emitted light beam could endanger your eyes. Note Never connect the PROFIBUS OBT to a 100 V - 240 V power supply. Note Install the device so that the climatic limit values in the technical specifications are adhered to. Note The RS-485 channel CH1 of the PROFIBUS OBT is isolated from the 24 V input. This isolation relates to functionality and is not a safety measure. Operating Instructions, 04/2016, C79000-G8976-C122-07 17

Commissioning Note Make sure that the PROFIBUS OBT is adequately grounded by connecting the DIN rail or mounting plate to local ground with low resistance and inductance. When securing the module to a mounting plate, run a cable from the grounding terminal of the OBT to the nearest possible ground, keeping the cable as short as possible. The shield of the PROFIBUS cable must be contacted. To do this, strip the insulation from the end of the PROFIBUS cable and connect the shield to functional earth. Note Only use bus cables approved for PROFIBUS as the RS-485 bus cable. Note The OBT housing must not be opened. General notices on use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. WARNING WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. WARNING WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. 18 Operating Instructions, 04/2016, C79000-G8976-C122-07

Commissioning WARNING This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or nonhazardous locations only. WARNING This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. General notice on use in hazardous areas according to ATEX WARNING Requirements for the cabinet/enclosure When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. WARNING Requirements for the cabinet/enclosure The modules must be installed in a suitable enclosure with at least degree of protection IP54 according to EN 60529. The environmental conditions under which the equipment will be used must be taken into account. WARNING Protection against transient voltage surges Take measures to prevent transient voltage surges of more than 40 % of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage). WARNING Suitable cables for high temperatures If the temperature exceeds 70 C at the entry point of the cable or the cable channel under conditions specified by the approval, or 80 C where the conductors branch, the temperature specification of the selected cable must correspond to the actual measured temperature. Operating Instructions, 04/2016, C79000-G8976-C122-07 19

Commissioning 5.1 Procedure for commissioning 5.1 Procedure for commissioning Commissioning the PROFIBUS OBT involves the following steps: Mounting the PROFIBUS OBT; Connecting the power supply; Connecting the optical bus cables; Connecting the electrical RS-485 bus cable. 5.2 Installation Mounting the PROFIBUS OBT The PROFIBUS OBTs can be mounted either on a 35 mm DIN rail with a height of 15 mm according to DIN 50 022-35 x 15 or directly on a flat surface. 1. Install the device so that the climatic limit values in the technical specifications are adhered to. 2. Make sure that there is adequate space to connect the bus and power supply cables. 3. Mount the modules only on a rail or mounting plate that is grounded with low resistance and inductance. When securing the module to a mounting plate, run a cable from the grounding terminal of the OBT to the nearest possible ground, keeping the cable as short as possible. Mounting on a DIN rail Fit the upper catch of the module over the DIN rail and push in the lower part of the module as shown in Figure 5-1 until it clicks in place. To remove the module, pull down the locking lever. 20 Operating Instructions, 04/2016, C79000-G8976-C122-07

Commissioning 5.2 Installation Image 5-1 Mounting a module on a DIN rail Mounting on a mounting plate The PROFIBUS OBTs have two holes. These allow mounting on any flat surface, for example on the mounting plate of a cabinet. Drill two holes in the mounting plate as shown in the drilling template in Figure 5-2. Secure the module with two machine screws (for example M3 x 75 and M3 x 55). Make sure that there is a reliable electrical connection between the terminal of the module housing and the grounded mounting plate using a grounding cable of at least 2.5 mm 2. Operating Instructions, 04/2016, C79000-G8976-C122-07 21

Commissioning 5.2 Installation Image 5-2 Mounting a module on a mounting plate Instructions for assembling plastic fiber-optic cable (with photos) You will find detailed instructions (with photos) on fitting connectors to plastic fiber-optic cables on the Internet (https://support.industry.siemens.com/cs/de/en/view/35222591) 22 Operating Instructions, 04/2016, C79000-G8976-C122-07

Commissioning 5.2 Installation Connecting the operating power supply Image 5-3 Pin assignment of the 3-pin terminal block grounding terminal and power supply M, L+ 1. Supply the PROFIBUS OBT only with a stabilized safety extra-low voltage complying with IEC 950 / EN 60 950/VDE 0805 of nominally 24 V (minimum 19.2 V and maximum 28.8 V). The power source must meet the requirements of NEC Class 2 according to the UL/CSA approval. 2. If the PROFIBUS OBT is not mounted on a grounded DIN rail, run a grounding cable with a cross-section of 2.5 mm 2 from the terminal to the nearest ground keeping the cable as short as possible. Operating Instructions, 04/2016, C79000-G8976-C122-07 23

Commissioning 5.2 Installation Connecting the optical bus cables Image 5-4 View of the module from the side with the optical channels CH2 and CH3 A = CH2, optical receiver B = CH2, optical transmitter C = CH3, optical receiver D = CH3, optical transmitter Connect the individual PROFIBUS OBTs using a duplex fiber-optic cable fitted with two pairs of simplex connectors. Make sure that an optical input is connected to an optical output (crossover connection). Provide adequate strain relief for the fiber-optic cable and remember the minimum bend radii of the FO cable. Close unused FO cable sockets with the supplied plastic plugs. Incident light from the surroundings can cause disturbances on the PROFIBUS network particularly, if the surroundings are very bright. Remember the minimum and maximum length of the FO cable and the permitted fiber types listed in Table 1 and in the technical specifications. Make sure that no dust gets into the optical components. Dust in the optical components can make them unusable. 24 Operating Instructions, 04/2016, C79000-G8976-C122-07

Commissioning 5.2 Installation The fiber of the FO cable must be flush with the surface of the connector. Note If the fiber juts out beyond the surface of the connector, the connector must not be inserted in the socket. Otherwise there is a risk of destroying the optical components. Connecting the electrical RS-485 cable Channel CH1 is used to connect a single PROFIBUS DP end device or an RS-485 segment. CH1 is designed as an electrical RS-485 interface with a 9-pin D-sub female connector. 1. As the RS-485 bus cable, use only shielded and twisted SIMATIC NET two-wire cables for PROFIBUS. 2. Do not connect any RS-485 bus cables that are laid entirely or partly outdoors. Otherwise, lightning strikes in the surroundings could destroy the PROFIBUS OBTs. If you have bus connections that leave the building, use fiber-optic cables whenever possible. 3. Disconnect the RS-485 bus cable from the OBT if you have not connected a node to the other end of the cable. Coupling in interference can cause disturbances on PROFIBUS. Operating Instructions, 04/2016, C79000-G8976-C122-07 25

Commissioning 5.2 Installation 26 Operating Instructions, 04/2016, C79000-G8976-C122-07

Help with problems during operation 6 6.1 Help with problems during operation LED display Possible cause of problems L+ 24 V LED not lit Power supply failed OBT defective L+ 24 V LED flashes The transmission speed could not be set CH1 LED not lit One or more wires of the RS-485 bus cable is interrupted Wires A and B of the RS-485 bus cable had been swapped over Connected PROFIBUS node is defective or is not transmitting PROFIBUS node or RS-485 segment is not connected or connected or PROFIBUS node is not turned on CH1 LED lit PROFIBUS nodes are, however, signaling problems on the bus Wires A and B of the RS-485 bus cable had been swapped over Short circuit on the RS-485 bus cable Interruption of one of the two wires of the RS-485 bus cable and A or B connected to wrong terminal Missing or incorrect termination CH2, CH3 LED not lit Send and receive FO cable connected to wrong socket Interruption of the receive FO cable to the partner module No partner module connected or connected partner module is not turned on Connected partner module is defective (not transmitting) CH2, CH3 LED lit PROFIBUS nodes are, however, signaling problems on the bus FO cable connector is loose (bad contact) FO cable link to the neighboring module is too long Interruption of the receive FO cable with extraneous light entering If no LED indicates an error and you are still experiencing problems in communication (for example an acknowledgement is not received, unexpected frames), you should check the monitoring times set on the PROFIBUS nodes (for example the slot time). You will find details in the description of your PROFIBUS end devices and your configuration software. Operating Instructions, 04/2016, C79000-G8976-C122-07 27

Help with problems during operation 6.1 Help with problems during operation 28 Operating Instructions, 04/2016, C79000-G8976-C122-07

Technical data 7 Table 7-1 Technical specifications General Operating voltage (safety extra-low voltage, SELV or to NEC Class 2) Current consumption at 24 V input Bleed resistance between terminal M and terminal Transmission speed Setting the transmission speed Operating mode 24 V= (19.2 V to 28.8 V) max. 180 ma 11 Mohms 12 Mbps, 6 Mbps, 3 Mbps, 1.5 Mbps, 500 Kbps, 187.5 Kbps, 93.75 Kbps, 45.45 Kbps, 19.2 Kbps, 9.6 Kbps performed automatically optical bus Bit error rate <10-9 Input channel 1 to 3 Bit length jitter Output channel 1 to 3 Bit length jitter Signal latency (any input/output) Cascading depth optical bus 0.7 to 1.3 tbit -0.03 to +0.03 tbit 0.99 to 1.01 tbit -0.003 to +0.003 tbit 6 tbit limited only by latency Electrical channel Input/output signal Input dielectric strength Minimum current at 5 V (for terminators) Electrical isolation to 24 V input RS-485 level -7 V to +12 V 10 ma Isolation due to functionality, not safety! Optical channel Optical source Injectable optical power with plastic fiber 980/1000 with PCF fiber 200/230 Sensitivity of receiver with plastic fiber 980/1000 with PCF fiber 200/230 Wavelength LED PT(min) PT(max) 5.9 dbm +0.5 dbm 16 dbm -1.5 dbm PR(min) PR(max) -20 dbm 0 dbm -22 dbm -2 dbm 640 nm to 660 nm Operating Instructions, 04/2016, C79000-G8976-C122-07 29

Technical data Optical channel Permitted FO cable attenuation (with link power margin) with plastic fiber 980/1000 with PCF fiber 200/230 Link distance with 3 db link power margin with plastic fiber 980/1000 with max. 200 db/km cable attenuation with PCF fiber 200/230 with max. 10 db/km cable attenuation Fiberoptic connectors 13 db 3 db 0.1 m to 50 m 0 m to 300 m Simplex / duplex Electromagnetic compatibility (EMC) Emission Limit class A (EN 55022) Immunity against static discharge On shield connector and housing parts: ±6 kv contact discharge (IEC 61000-4-2) Immunity against RF radiation 10 V/m at 80% amplitude modulation with 1 khz, 80 MHz 1 GHz (ENV 50140; IEC 61000 4 3) 10 V/m with 50% load factor at 900 MHz (to ENV 50 204) 10 V/m at 80% amplitude modulation with 1 khz, 10kHz 80 MHz (ENV 50141) Immunity to conducted disturbances (burst) On power supply cables and shielded RS-485 bus cables: ±2 kv (IEC 61000 4 4) Immunity to conducted disturbances (surge) On power supply cables: ±1 kv symmetrical and +-2 KV asymmetrical On shielded RS485 bus cables: ±2 kv asymmetrical (IEC 61000 4-5) Safety VDE regulation VDE 0806 = EN60950 and IEC 60950-1 UL/CSA approval complying with UL 60950-1, CSA C22.2 No. 60950-00 Climatic environmental conditions Ambient temperature 0 C to +60 C (IEC 60068-2-1, IEC 60068-2-2) Storage temperature -40 C to +70 C (IEC 60068-2-1, IEC 60068-2-2) 30 Operating Instructions, 04/2016, C79000-G8976-C122-07

Technical data Climatic environmental conditions Relative humidity < 95% (no condensation) (IEC 60068-2-30) Fast change of temperature during operation 0 C to +60 C; exposure time 3 h; temperature change 3 K/min.; 5 cycles (IEC 60068-2-14) Mechanical environmental conditions Oscillation in operation Oscillation during transportation Degree of protection (with external fuse 8 A) Weight Dimensions Housing material 10 to 58 Hz, 0.075 mm excursion 58 to 150 Hz, 10 m/s2 (1g) acceleration (IEC 60068-2-6) 5 to 9 Hz, 3.5 mm excursion 9 to 500 Hz, 10 m/s2 (1g) acceleration (IEC 60068-2-6) IP30 400 g 50.5 x 138 x 78 mm Noryl anthracite Operating Instructions, 04/2016, C79000-G8976-C122-07 31

Technical data 32 Operating Instructions, 04/2016, C79000-G8976-C122-07

Approvals and certificates 8 8.1 Notes on the CE mark Product name Optical Bus Terminal PROFIBUS OBT, article number: 6GK1500-3AA10 EC directive EMC 2014/30/EEC The above product meets the requirements of the EC Directive:2014/30/EEC "Electromagnetic Compatibility" in an industrial environment. Area of application Requirements Emissions Immunity Industry EN 61000-6-4: 2007 + A1: 2011 EN 61000-6-2: 2005 RoHS RoHS directive (restriction of the use of certain hazardous substances) The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 - Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances Declaration of conformity The EC Declaration of Conformity is available for the responsible authorities according to the above-mentioned EC directive at the following address: Siemens Aktiengesellschaft Process Industries and Drives Division Process Automation Industrial Communication and Identification PD PA CI R&D Postfach 4848 D-90026 Nürnberg Operating Instructions, 04/2016, C79000-G8976-C122-07 33

Approvals and certificates 8.1 Notes on the CE mark Installation guidelines The product meets the requirements if you adhere to the installation guidelines included in Optical Bus Terminal PROFIBUS OBT documentation during installation and operation. The accessible radiation power of the transmit LEDs used complies with Class 1 according to 60950-1: 2006 + A11 + A1 + A12 + A2, EN 60825-1: 2014 and EN 60825-2: 2004 + A1: 2007 + A2: 2010 The accessible radiation powers after opening the FO cable deliberately or accidentally correspond to degree of danger 1 according to EN 60825 2: 2004 + A1: 2007 + A2: 2010 or IEC 60825-2: E3.2 (2010) Notes for the manufacturers of machines Communications processors are not machines in the sense of the EC Machinery Directive 2006/42/EEC. There is therefore no declaration of conformity relating to the current version of the EC Machinery Directive 2006/42/EEC for these products. If the products are part of the equipment of a machine, they must be included in the declaration of conformity procedure by the manufacturer of the machine. Explosion protection directive (ATEX) The SIMATIC NET product meets the requirements of the EC directive:2014/34/ec "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres". WARNING When using (installing) SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions are adhered to. You will find information on this on the Manual Collection DVD. ATEX code: KEMA 07ATEX0145 X II 3 G Ex na IIC T4 Gc The product meets the requirements of the standards EN 60079-15 (Electrical apparatus for potentially explosive atmospheres; Type of protection "n") and EN 60079-0 + A11 You will find the current versions of the standards in the currently valid ATEX certificates. 34 Operating Instructions, 04/2016, C79000-G8976-C122-07

Approvals and certificates 8.1 Notes on the CE mark IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. FM approval The product meets the requirements of the standards Factory Mutual Approval Standard Class Number 3611 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus Approval for Information Technology Equipment culus Listed I. T. E. Underwriters Laboratories Inc. complying with UL 60950-1 (Information Technology Equipment) CSA C22.2 No. 60950-1-07 culus Approval Hazardous Location culus Listed I. T. E. FOR HAZ. LOC. Underwriters Laboratories Inc. complying with UL 60950-1 (Information Technology Equipment) CSA C22.2 No. 213-M1987 UL 1604 and 2279-15 (Hazardous Location) Approved for use in Cl. 1, Div. 2, GP. A, B, C, D, T4 Cl. 1, Zone 2, GP. IIC T4 Operating Instructions, 04/2016, C79000-G8976-C122-07 35

Approvals and certificates 8.1 Notes on the CE mark 36 Operating Instructions, 04/2016, C79000-G8976-C122-07