CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES

Similar documents
Sprinklers Modeling for Tunnel Road Fire Fighting

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Tunnel Fire Dynamics and Evacuation Simulations

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

and Sprinkler System in Resalat Tunnel of Tehran

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Considerations in the Design of Smoke Management Systems for Atriums

Impact of Tunnel Ventilation on Tunnel Fixed Fire Suppression System

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Aspirating Gas Detection CFD Modelling Predicts Application Performance

EMERGENCY VENTILATION FOR SMOKE CONTROL IN ROADWAY TUNNELS (NCHRP PROJECT TASK 363)

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

An experimental study of the impact of tunnel suppression on tunnel ventilation

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Fire and Smoke Management in a Uni-Directional Road Tunnel for a Congested Traffic Condition

Case Study 1 Underground Car Park

Hot Issues in Fire Engineering 12 March 2013

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

SOLIT PROJECT: WATER MIST FIRE SUPPRESSION SYSTEMS AS PART OF THE TUNNEL SAFETY SYSTEM

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Case Study of Underground Car Park. Team Japan

Computational simulation of road tunnel fire protection by sprinklers

TUNPROTEC. Active Tunnel Fire Protection

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Impact of quick incident detection on safety in terms of ventilation response

Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

The first tunnel fire. Benefits of fire

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

International Seminar on Long Tunnels - October 17-19, 2012 CHILE Santiago World Road Association (PIARC )

Tunnel Axial Flow Fan

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

NOVENCO CAR PARK THRUST VENTILATION SYSTEM DESCRIPTION. Pure competence in air.

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

CFD Model of a Specific Fire Scenario

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Fire Scenario Influence of Material of Boundary Condition on Results

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

RETOS Y TENDENCIAS DESARROLLO DE INFRAESTRUCTURA EN AUSTRIA. Leonardo Rosas Sánchez Bogotá Agosto 9 de 2018

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

Fire Research and Education at the University of Maryland

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Modeling a real backdraft incident fire

Mobile ventilation units in tunnels

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Developing a fire model for offshore QRA

Ventilation for Smoke Control, Fire Control & Life Safety in Tunnels. Dr. Ricky Carvel BRE Centre for Fire Safety Engineering University of Edinburgh

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Case Study 2 (Production and Storage Buildings) - Spain

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

A study for a fire spread mechanism of residential buildings with numerical modeling

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

FIRE RESISTANCE OF ROLLING STOCK ELEMENTS STANDARD AND SPECIAL CASE OF TUNNELS

Compression of Fins pipe and simple Heat pipe Using CFD

PHASED CONSTRUCTION AND SAFETY IN MALA KAPELA TUNNEL

CFD Simulation of the Water Mist Effect on Fire

Max Fire Box Users Guide

Tunnel Fire Dynamics

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

A comparison between emergency ventilation systems semi-transvers ventilation and natural ventilation in Road Tunnel A

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Comparative Simulation ResultsforEN-54, НПБ 88 and NFPA 72 Standards-the Hallway Case

Chapter 17, Initiating Devices

Simulation of Full-scale Smoke Control in Atrium

( )

Advantages and Disadvantages of Fire Modelling

Recent BRANZFIRE enhancements and validation

Simulation of Engine Room Fire and Water Mist. Einar Kolstad and Bjarne P. Husted Stord/Haugesund University college

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

LOW-NOX BURNER RETROFIT CHALLENGE

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Computer Models For Fire and Smoke

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

CFD Analysis of Fire Characteristics on Subway Junction Station

Underground fires in metro systems failures, accidents and terrorism

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Heat transfer and heating rate of food stuffs in commercial shop ovens

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Transcription:

UDC 614.84 : 628.854 : 52-17 DOI: 10.7562/SE2011.1.01.03 Original article www.safety.ni.ac.rs DARKO ZIGAR 1 DESIMIR JOVANOVIĆ 2 MARTINA ZDRAVKOVIĆ 3 1-4 University of Niš, Faculty of Occupational Safety in Niš 1 darko.zigar@ znrfak.ni.ac.rs 2 desimir.jovanovic@ znrfak.ni.ac.rs 3 martina.zdravkovic@ znrfak.ni.ac.rs CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES Abstract: Field modelling based on the Computational Fluid Dynamics methodology plays an important role in fire research, and in the fire safety design and risk assessment of buildings: CFD codes can potentially be used to evaluate the effects of different designs and of emergency systems, and to assess the performance of safety measures over a wide range of fire scenarios. In this study the NIST Fire Dynamics Simulator version 5 (FDS5), a computational fluid dynamic (CFD) model, was used to simulate a series of full-scale fire tests of ventilation and sprinkler systems conducted in a test tunnel. Key words: tunnel, fire, ventilation, sprinkler, simulation. INTRODUCTION Fires in road and railway tunnels are particularly dangerous because the amount of firing material can be huge and the length of the way to escape outside the enclosure can be in some cases several kilometres. Fire accidents in road tunnels have proven to be extremely costly in terms of human lives, increased congestion, pollution and reparation. Development of fire and smoke spread are affected by the fire set-up and ventilation conditions in the tunnel. To prevent fires in road and railway tunnels existing tunnels should be upgraded and new tunnels should be equipped with efficient fire protection systems. One of a the adequate methods that may be used to prove the characteristics of a fire safety measures is fire simulations. PROBLEM DESCRIPTION The ventilation system is used for controlling smoke, hot and toxic combustion gases during a fire emergency, in order to allow safe evacuation and rescue. Ventilation may be provided by natural means (Fig. 1), or by mechanical equipment (longitudinal, semi-transverse or full transverse ventilation systems, (Fig. 3 ). created by atmospheric conditions and differences in elevation (Fig. 2). Figure 2. Smoke behaviour in a sloping tunnel The longitudinal ventilation system (Fig. 3) creates a longitudinal flow along the roadway tunnel by introducing or removing air from the tunnel at a number of points. Longitudinal flow is provided by jet fans. Figure 1. Natural ventilation With no air current in the fire zone, the smoke progresses in a symmetrical way on both sides of the fire. The smoke remains stratified until it cools down due to the combined effects of the convective heat exchange with the walls and the mixing between the smoke and the fresh air layer, [1]. A natural ventilation system depends on the pressure differential that is Paper is presented at the "International Conference Safety of Technical Systems in Living and Working Environment", Faculty of Occupational Safety in Niš, October 2011, Niš. 11 Safety Engineering Figure 3. Longitudinal ventilation system

SAFETY ENGINEERING - INŽENJERSTVO ZAŠTITE The ventilation system would be operated to force the smoke and hot gases in the direction of the empty tunnel to provide a clear and safe environment behind the fire for evacuees and fire fighters. If the ventilation capacity is sufficient (Fig. 4b and Fig. 4c), all of the heated air and smoke will flow in the downstream direction. If the ventilation is weak (Fig. 4a), the upper layer of heated air and smoke may flow in the opposite direction causing backlayering, [1]. The simultaneous solution of Eqn. (1) and Eqn. (2), by iteration, determines the critical velocity. The critical velocity, Vc, is the minimum steady-state velocity of the ventilation air moving toward a fire that is necessary to prevent backlayering, [5]. 1/3 ghq VC = K1Kg (1) ρcpat f Q Tf = + T (2) ρcpav C Where: A - Area perpendicular to the flow [(m 2 )] C p - Specific heat of air [(kj/kg K)] g - Acceleration caused by gravity [(m/sec 2 )] H - Height of duct or tunnel at the fire site [(m)] K 1-0.606 K g - Grade factor (see Fig. 6) Q - Heat fire is adding directly to air at the fire site [(MW)] T - Temperature of the approach air [(K)] T f - Average temperature of the fire site gases [(K)] V c - Critical velocity [(m/sec)] ρ - Average density of the upstream air [(kg/m 3 )] Figure 4. Influence of longitudinal air velocity (Vvent) on smoke progress in the fire zone (Vc= critical velocity) The occurrence of backlayering depends on many factors including the intensity of fire, the grade and geometry of the tunnel, and the velocity of the ventilating air approaching the fire. The ability of the longitudinal ventilation system to prevent backlayering is the current industry standard to measure the adequacy of the system for smoke control (Fig. 5). Figure 6. Grade factor for determining critical velocity For large tunnel fires critical velocity can be taken as dependent of the HRR (Fig. 7). Figure 5. Backlayering distance vs. longitudinal air velocity for two heptane pool surfaces Figure 7. Critical velocities as function of total HRR according to four different relations 12 Safety Engineering

D. Zigar, D. Jovanović, M. Zdravković, Vol 1, N o 1 (2011) 11-16 Fire Data for Typical Vehicles, according NFPA 502 Standard for Road Tunnels, Bridges and Other Limited- Access Highways are shown in the Table 1, [5]. Table 1. Fire Data for Typical Vehicles Type of vehicle HRR (MW) Car 5-10 Multiple passenger cars (2-4 vehicles) 10-20 Bus 20-30 Heavy goods truck 70-200 Tanker 200-300 In Figure 8 the five fire temperature curves are presented graphically (the first two hours), [2]. (e) Even a light spray from sprinklers can catch motorists unaware and can exceed that which windshield wipers could clear. Sprinkler discharge can also cause the roadway to become dangerously slippery. (f)water that sprays from the ceiling of a subaqueous tunnel suggests tunnel failure and can induce panic in motorists. (g) The use of sprinklers can cause the delamination of the smoke layer and induce turbulence and mixing of the air and smoke, thus threatening the safety of motorists in the tunnel. (h) Periodic testing of a fire sprinkler system to determine its state of readiness is impractical and costly. NUMERICAL MODEL Figure 8. Specific temperature curves of hydrocarbon fires in tunnels In Japan and Australia water extinguishment systems are widely used in tunnels. In Europe, however, there has been a reluctance to use sprinkler in tunnels. According NFPA 502 Standard the major concerns expressed by tunnel authorities regarding fire sprinkler use and effectiveness include the following, [5]: (a) Typical fires usually occur under vehicles or inside passenger or engine compartments that are designed to be waterproof from above; therefore, overhead sprinklers have no extinguishing effect. (b) With any delay between ignition and sprinkler activation, a thin water spray on a very hot fire produces large quantities of superheated steam without suppressing the fire. Such steam has the potential to be more damaging than smoke. (c) Tunnels are long and narrow, often sloped laterally and longitudinally, usually ventilated, and never subdivided, so heat normally is not localized over a fire. (d) Because of stratification of the hot gases plume along the tunnel ceiling, a number of activated sprinklers are unlikely to be located over the fire. A large number ofactivated sprinklers are likely to be located at a distance from the fire scene, producing a cooling effect that tends to draw the stratified layer of smoke down toward the roadway level. For the calculation of temperature fields and smoke concentration fields formed in case of fire within the tunnel space, the CFD software package NIST Fire Dynamics Simulator version 5 (FDS5) was used. For the calculation of flow and temperature fields of the air formed within the tunnel, k-ε turbulent model was used. Because of certain identical segments of the tunnel and the high length of the entire tunnel (Fig 9), in simulation used segment he was dimension: 600m(segment 60m) x 11.7m x 7.1m (lenght, wide, high, respectivelly). The FDS5 domain was divided into cells of dimension 0.15 m 0.15 m 0.15 m. The tunnel is built at grade in concrete. The fire source in the simulation was represented by burning of a flammable liquid in a pool with dimensions 5 x 5 m. The maximum heat release rate per unit area (HRRPUA) of the fire was 4000 kw and the total heat release rate (HRR) was 100 MW. The initial air temperature in the whole tunnel was set to 20 C. This calculation determined that the ventilation of each tunnel segment is to be carried out by 2 2 pairs of regularly arranged jet fans and three parallel lines of sprinklers K-11 type. Distance between sprinklers is 3.05 m, according NFPA 13 Standard, [6]. The maximum volumetric flow of fresh air through these jet fans should be 17.1 m 3 /s and 34.2 m 3 /s. Figure 9. The computational domain for the tunnel fire simulations 13 Safety Engineering

SAFETY ENGINEERING - INŽENJERSTVO ZAŠTITE RESULTS OF CALCULATIONS Spread of smoke in a tunnel a) Natural ventilation b) Forced ventilation (jet fan 17.1 m 3 /s)- backlayering c) Forced ventilation (jet fan 34.2 m 3 /s) Figure 10. Spread of smoke in a tunnel a) Without sprinklers activation b) Sprinklers activated Figure 11. Spread of smoke in a tunnel without and with activated sprinklers Temperature schedule a) Natural ventilation b) Forced ventilation (jet fan 17.1 m 3 /s)- backlayering 14 Safety Engineering

D. Zigar, D. Jovanović, M. Zdravković, Vol 1, N o 1 (2011) 11-16 c) Forced ventilation (jet fan 34.2 m 3 /s) Figure 12. Temperature schedule along the centreline vertical plane Figure 13. Temperature schedule along the centreline vertical plane with activated sprinklers Sprinklers activation Sprinklers position a) Sprinklers activation: 20 sec. since ignition b) Sprinklers activation: 30 sec. since ignition c) Sprinklers activation: 40 sec. since ignition Figure 14. Splinklers position and activation 15 Safety Engineering

SAFETY ENGINEERING - INŽENJERSTVO ZAŠTITE CONCLUSION In the event of a fire in an tunnel with natural ventilation (Fig. 10a), due to difference in densities, hot combustion products rise above the fire and entrain the surrounding cold air forming a plume. The rising plume reaches the ceiling and forms two smoke streams flowing in opposite directions along the ceiling. In tunnels with longitudinal ventilation systems (Fig. 10b and Fig. 10c), the symmetry of the rising plume and the ceiling smoke streams is broken. The rising plume bends and the length of the ceiling layer flowing against the ventilation current is reduced. The reversal of the flow of the plume is referred to as backlayering (Fig. 10b). If ventilation system operates only half at the maximum flow rate designed for the ventilation of the tunnel (17.1 m 3 /s) come to a backlayering effect. If ventilation system operates only at the maximum flow rate designed for the ventilation of the tunnel (Fig.10c), no wil be backlayering effect. In fire simulation with sprinklers, sprinklers activation come to destroying the smoke stratification (Fig. 11b) and there by decreasing the visibility, spreading liquid fuel over a larger area and there by spreading the fire, the risk for explosion, the production of steam affecting the people inside the tunnel. The maximum predicted gas temperature near the ceiling was just below 1000 C (Fig. 12), in simulations with activated sprinklers 925 C (Fig. 13). Also, the sprinkler system was not able to reduce temperature directly above the fire in the unshielded simulation. Apparently, sprinkler droplets are too light to penetrate the fire plume and are simply swept away. Simulation results suggested that the longitudinal ventilation system was very effective for blowing all smoke and hot gases in the downstream direction, which could be generally deemed empty, so immediately creating upstream the fire a safe route for evacuation and rescue. REFERENCES [1] A. Kashef, N. Bénichou, G. Lougheed: Numerical modelling and behaviour of smoke produced from fires in the Ville-Marie and L.-H.-La ontaine Tunnels, literature review, NRCC Report IRC-RR-141, 2003. [2] D. Lacroix, A. Haack: PIARC Design Criteria for Resistance to Fire for Road Tunnel Structures, In Joint Issue ITA/PIARC of Route-Roads on Fire Safety in Tunnels, 2004. [3] K. McGrattan, S.Hostikka, J. Floyd, H. Baum, R. Rhem: Fire Dynamics Simulator (Version 5) Technical reference guide, National Institute of Standards and Technology, 2007, Washington. [4] M. Banjac, B.Nikolić: Simulation of a tunnel fire and optimization of the ventilation system with the use of numerical fluid dynamics, 11 th International conference on fire and explosion protection, Novi Sad, 2008, pp. 44-50. [5] NFPA 502: Standard for Road Tunnels, Bridges, and other Limited Access Highways, 2004 ed., National Fire Protection Association, 2004. [6] NFPA 13: Standard for The Installation of Sprinkler Systems, 1999 ed., National Fire Protection Association, 1999. BIOGRAPHY Darko Zigar was born on April 16, 1973. in Pancevo, Serbia. He received B.Sc. degree in Environmental Protection and M.Sc. degree in Occupational Safety in 2002 and 2007 respectively, from University of Niš, Serbia. He has been with the Faculty of Occupational Safety, University of Niš, since 2008., where he is working as a researcher / assistant lecturer. His areas of expertise include numerical fire simulations, as well as investigations of possible adverse effects of electromagnetic field irradiation from mobile phones and wireless systems. 16 Safety Engineering